Search NASA⌕ Search

SEARCH · Search NASA

Results for “tremor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Hand tremor and activity sensor

System detects hand tremor and activity and transmitting signals over distance of at least 3 meters to receiver system. Designed for use in studies of effect of fatigue on individual's judgement or reaction time, sensor is installed within mounting of finger-ring; no external wiring or power source is needed.

Konigsberg, E.↗

Study on the neuronal circuits implicated in postural tremor and hypokinesia

The effect of various tegmentary lesions at the level of the pontomesenchphalon in monkeys on motor function was observed. The importance of the monoaminergic mechanisms of the brainstem is discussed. The results also show the importance of the descending tegmentary rubral system and the rubroolivocerebellar circuit in controlling peripheral motor activity. The destruction of the sensory motor cortex proves to be a more effective way of eliminating spontaneous or harmaline induced tremor than the complete interruption of the pyramidal system on the level of the cerebral peduncle.

Poirier, L. J.↗

Dexterity enhancement in microsurgery using telemicro-robotics

The presentation will focus on finding the spectrum of dexterity performance while performing microsurgery in various specialties. It will be noted that individuals vary markedly in their performance in the position, velocity, stability, and force domains. There are surgeons who have a tremor who otherwise move very slowly and carefully while there are other surgeons who apply excessive force, but never have a tremor or move excessively fast. There are yet other surgeons who move excessively fast, yet they do not have a tremor. Dexterity enhancement includes position down scaling, tremor filtering, fatigue elimination, and other second-order issues such as confining the work space, velocities, accelerations, or forces. It will be described that the hand's position performance is degraded when it is asked to actuate the tools and that remote actuation alone increases the positioning capabilities. It will be noted that rotary and telescopic functions are far more difficult than writing or engraving-like motions. The safety issues concerning velocities and forces will be discussed and the need for impedance control pointed out. Simplistically, the devices should be made with variable compliance so that they can function rigidly as a robot would or compliantly as a human would, depending on the setting of this parameter. Tool interfaces will be discussed with an emphasis on the overall performance of the position, end effector, and tool as a unit. Space constraints, force, and velocity requirements will be discussed in this section as well. Referencing the coordinate system to pre- or inter-operative imaging systems will be discussed as well as an emphasis on the system architecture.

Charles, Steve↗

Modeling and measuring limb fine-motor unsteadiness

Fine-motor unsteadiness its properties, conceptual and analytical models, and experimental measurements is examined. Based on a data review, the tentative model derived includes: neuromuscular system, grip interface, and control system dynamic elements. The properties of this model change with muscle tension and match a wide group of extant data. A simple experiment was performed to investigate the amplitude/force relationships of the tremor mode. As the finger-pull force increased from 5 to 20 Newtons, the tremor mode frequency for a given individual stayed within roughly + or - 1 Hz over a range from 9-12 Hz, while the average magnitude of the rms tremor acceleration increased tenfold. A standardized test for making such measurements is given and applications in the fields of psychophysiological stress and strain measurements are mentioned.

Magdaleno, R. E.↗

Lunar regolith densification

Core tube samples of the lunar regolith obtained during the Apollo missions showed a rapid increase in the density of the regolith with depth. Various hypotheses have been proposed for the possible cause of this phenomenon, including the densification of the loose regolith material by repeated shaking from the seismic tremors which have been found to occur at regular monthly intervals when the moon and earth are closest to one another. A test bed was designed to study regolith densification. This test bed uses Minnesota Lunar Simulant (MLS) to conduct shaking experiments in the geotechnical centrifuge with an inflight shake table system. By reproducing realistic in-situ regolith properties, the experiment also serves to test penetrator concepts. The shake table system was designed and used for simulation experiments to study effects of earthquakes on terrestrial soil structures. It is mounted on a 15 g-ton geotechnical centrifuge in which the self-weight induced stresses are replicated by testing an n-th scale model in a gravity field which is n times larger than Earth's gravity. A similar concept applies when dealing with lunar prototypes, where the gravity ratio required for proper simulation of lunar gravity effects is that between the centrifugal acceleration and the lunar gravity. Records of lunar seismic tremors, or moonquakes, were obtained. While these records are being prepared for use as the input data to drive the shake table system, records from the El Centro earthquake of 1940 are being used to perform preliminary tests, using a soil container which was previously used for earthquake studies. This container has a laminar construction, with the layers free to slide on each other, so that the soil motion during the simulated earthquake will not be constrained by the otherwise rigid boundaries. The soil model is prepared by pluviating the MLS from a hopper into the laminar container to a depth of 6 in. The container is mounted on the shake table and the centrifuge is operated to generate an acceleration of 10 times Earth's gravity or 60 times the lunar gravity, thus simulating a lunar regolith thickness of 30 ft. The shake table is then operated using the scaled 'moonquake' as the input motion. One or more model moonquakes are used in each experiment, after which the soil is analyzed for its density profile with depth. This is accomplished by removing from the soil bed a column of soil contained within a thin rubber sleeve which has been previously embedded vertically in the soil during pluviation. This column of soil is transferred to a gamma ray device, in which the gamma ray transmission transversely through the soil is measured and compared with standard calibration samples. In this manner, the density profile can be determined. Preliminary results to date are encouraging, and the Center plans to study the effects of duration of shaking, intensity of the shaking motion, and the frequency of the motion.

Ko, Hon-Yim↗

The Stop-and-Go Mechanism: Towards an Integrated Approach to Model Seismicity, Outgassing, Deformation, and Thermal Unrest at Active Volcanoes

Connecting the geophysical and geochemical signals recorded at and above the surface of volcanoes with source mechanisms is fundamental to understand transitions from quiescence to eruption, and to integrate the behavior of volcanoes with their regional seismotectonic and hydrological context. Some of these signals include shallow volcanic tremor, a long-lasting (minutes-to-years) ground vibration detected in volcanic areas during unrest; volcanic outgassing, which shows intriguing periodicities over multiple scales, as revealed by space-borne instruments and by ground-based, high-frequency (~1 Hz), sampling methods; inflation and deflation of volcanic edifices, commonly associated with subsurface volume changes; and large-scale (from a few to tens of km2), low-temperature, thermal anomalies, a newly-discovered signal that has been observed to emerge on volcanic flanks from months-to-years prior to gas- and magma-driven eruptions. Traditionally, these geophysical and geochemical signals have been modelled independently, which limits our interpretation of subsurface processes and thus our assessment of unrest. In this work, we show through lumped-parameter models, numerical simulations, and preliminary laboratory experiments that many of the signals recorded around volcanoes can be integrated into a common “stop-and-go” mechanism. In particular, we found that they can arise spontaneously when taking into account the feedbacks between the temporary accumulation of gas and/or magma in the crust (“stop”), and the diffusive transfer of gas and heat towards the surface (“go”). For example, we find that the “stop-and-go” mechanism can explain: (i) the emergence of monochromatic, broadband, and harmonic tremor; (ii) the periodic components commonly observed in volcanic outgassing time series; (iii) the link between large-scale thermal anomalies and shallow hydrothermal systems; (iv) the reported time lags between large-scale thermal anomalies and deformation; and (v) the breathing of potentially destructive volcanic calderas. The “stop-and-go” mechanism provides a consistent and realistic framework to link multiple geophysical and geochemical signals with the processes leading to volcanic unrest and eruption.

volcanoes↗

A stochastic model for eye movements during fixation on a stationary target.

A stochastic model describing small eye movements occurring during steady fixation on a stationary target is presented. Based on eye movement data for steady gaze, the model has a hierarchical structure; the principal level represents the random motion of the image point within a local area of fixation, while the higher level mimics the jump processes involved in transitions from one local area to another. Target image motion within a local area is described by a Langevin-like stochastic differential equation taking into consideration the microsaccadic jumps pictured as being due to point processes and the high frequency muscle tremor, represented as a white noise. The transform of the probability density function for local area motion is obtained, leading to explicit expressions for their means and moments. Evaluation of these moments based on the model is comparable with experimental results.

Vasudevan, R.↗

Future ultra-speed tube-flight

Future long-link, ultra-speed, surface transport systems will require electromagnetically (EM) driven and restrained vehicles operating under reduced-atmosphere in very straight tubes. Such tube-flight trains will be safe, energy conservative, pollution-free, and in a protected environment. Hypersonic (and even hyperballistic) speeds are theoretically achievable. Ultimate system choices will represent tradeoffs between amoritized capital costs (ACC) and operating costs. For example, long coasting links might employ aerodynamic lift coupled with EM restraint and drag make-up. Optimized, combined EM lift, and thrust vectors could reduce energy costs but at increased ACC. (Repulsive levitation can produce lift-over-drag l/d ratios a decade greater than aerodynamic), Alternatively, vehicle-emanated, induced-mirror fields in a conducting (aluminum sheet) road bed could reduce ACC but at substantial energy costs. Ultra-speed tube flight will demand fast-acting, high-precision sensors and computerized magnetic shimming. This same control system can maintain a magnetic 'guide way' invariant in inertial space with inertial detectors imbedded in tube structures to sense and correct for earth tremors. Ultra-speed tube flight can complete with aircraft for transit time and can provide even greater passenger convenience by single-model connections with local subways and feeder lines. Although cargo transport generally will not need to be performed at ultra speeds, such speeds may well be desirable for high throughput to optimize channel costs. Thus, a large and expensive pipeline might be replaced with small EM-driven pallets at high speeds.

Salter, Robert M.↗

Evaluation of a telerobotic system to assist surgeons in microsurgery

A tool was developed that assists surgeons in manipulating surgical instruments more precisely than is possible manually. The tool is a telemanipulator that scales down the surgeon's hand motion and filters tremor in the motion. The signals measured from the surgeon's hand are transformed and used to drive a six-degrees-of-freedom robot to position the surgical instrument mounted on its tip. A pilot study comparing the performance of the telemanipulator system against manual instrument positioning was conducted at the University of Southern California School of Medicine. The results show that a telerobotic tool can improve the performance of a microsurgeon by increasing the precision with which he can position surgical instruments, but this is achieved at the cost of increased time in performing the task. We believe that this technology will extend the capabilities of microsurgeons and allow more surgeons to perform highly skilled procedures currently performed only by the best surgeons. It will also enable performance of new surgical procedures that are beyond the capabilities of even the most skilled surgeons. Copyright 1999 Wiley-Liss, Inc.

Microsurgery/instrumentation/methods↗

Got Mercury?

Many of the operational and payload lighting units used in various spacecraft contain elemental mercury. If these devices were damaged on-orbit, elemental mercury could be released into the cabin. Although there are plans to replace operational units with alternate light sources, such as LEDs, that do not contain mercury, mercury-containing lamps efficiently produce high quality illumination and may never be completely replaced on orbit. Therefore, exposure to elemental mercury during spaceflight will remain possible and represents a toxicological hazard. Elemental mercury is a liquid metal that vaporizes slowly at room temperature. However, it may be completely vaporized at the elevated operating temperatures of lamps. Although liquid mercury is not readily absorbed through the skin or digestive tract, mercury vapors are efficiently absorbed through the respiratory tract. Therefore, the amount of mercury in the vapor form must be estimated. For mercury releases from lamps that are not being operated, we utilized a study conducted by the New Jersey Department of Environmental Quality to calculate the amount of mercury vapor expected to form over a 2-week period. For longer missions and for mercury releases occurring when lamps are operating, we conservatively assumed complete volatilization of the available mercury. Because current spacecraft environmental control systems are unable to remove mercury vapors, both short-term and long-term exposures to mercury vapors are possible. Acute exposure to high concentrations of mercury vapors can cause irritation of the respiratory tract and behavioral symptoms, such as irritability and hyperactivity. Chronic exposure can result in damage to the nervous system (tremors, memory loss, insomnia, etc.) and kidneys (proteinurea). Therefore, the JSC Toxicology Group recommends that stringent safety controls and verifications (vibrational testing, etc.) be applied to any hardware that contains elemental mercury that could yield airborne mercury vapor concentrations greater than 0.1 mg/cu m in the total spacecraft atmosphere for exposures lasting 30 days or less or 0.01 mg/cu m mercury vapor for exposures lasting more than 30 days. We also encourage the use of alternative devices that do not contain mercury.

Meyers, Valerie E.↗

Modeling Pilot Pulse Control

In this study, behavioral models are developed that closely reproduced pulsive control response of two pilots from the experimental pool using markedly different control techniques (styles) while conducting a tracking task. An intriguing find was that the pilots appeared to: 1) produce a continuous, internally-generated stick signal that they integrated in time; 2) integrate the actual stick position; and 3) compare the two integrations to issue and cease pulse commands. This suggests that the pilots utilized kinesthetic feedback in order to perceive and integrate stick position, supporting the hypothesis that pilots can access and employ the proprioceptive inner feedback loop proposed by Hess' pilot Structural Model. The Pulse Models used in conjunction with the pilot Structural Model closely recreated the pilot data both in the frequency and time domains during closed-loop simulation. This indicates that for the range of tasks and control styles encountered, the models captured the fundamental mechanisms governing pulsive and control processes. The pilot Pulse Models give important insight for the amount of remnant (stick output uncorrelated with the forcing function) that arises from nonlinear pilot technique, and for the remaining remnant arising from different sources unrelated to tracking control (i.e. neuromuscular tremor, reallocation of cognitive resources, etc.).

workload↗

Development of Low-Cost Micromanipulation Systems for Small Extraterrestrial Samples

The analysis of microscale to mm-scale astromaterials often involves the transfer of samples from storage or collection substrates to analytical substrates. These transfers are accomplished by hand (via tweezers or fine-tipped needles) or by utilizing micromanipulation instruments. Freehand manipulation of small particles is extremely challenging due to involuntary hand tremors on the order of 100μm and due to the triboelectric charging induced by frequent contact between the manipulation tool and the support substrate. Months or years of practice may be required before an investigator develops the necessary experience to confidently transfer a 10-20μm particle in this manner. Handling even mm-sized particles with fine-tipped tweezers can be challenging, due to the inability to precisely control the force with which grains are being held. Mechanical, hydraulic, and motorized/electrical micromanipulators enable the precise handling of microscale samples and are often utilized in laboratories where frequent small sample preparation is required. However, the price of such instruments (~ $10,000 to $100,000) makes them cost-prohibitive for some institutions. Graduate students or early-career scientists interested in conducting research on interplanetary dust particles, Itokawa particles returned by Hayabusa, or future samples returned by OSIRIS-REx or Hayabusa2 may experience difficulty in justifying the expense of a micromanipulator to their advisors or principle investigators. Johnson Space Center’s Astromaterials Acquisition and Curation Office and the Lunar and Planetary Institute conduct annual training for early career scientists and for investigators that require experience with handling of small extraterrestrial samples. In support of this training, we have been developing low-cost mechanical alternatives to expensive micromanipulators that training participants can implement in their respective facilities.

Snead, Christopher J.↗