At least 19 records

Beta Decay of Molecular Tritium

The beta decay of tritium in the form of molecular T 2 is the basis of sensitive experiments to measure neutrino mass. The final-state electronic, vibrational, and rotational excitations modify the beta spectrum significantly and are obtained from theory. We further determine measurements of the branching ratios to specific ionization states for the isotopolog HT. Two earlier, concordant measurements gave branching ratios of HT to the bound HHe + ion of 89.5% and 93.2%, in sharp disagreement with the theoretical prediction of 55%–57%, raising concerns about the theory’s reliability in neutrino mass experiments. Our finding, 56.5(6)%, is compatible with the theoretical expectation and disagrees strongly with the previous measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Project 8: Measuring the tritium beta-decay spectrum using Cyclotron Radiation Emission Spectroscopy

Abstract. The goal of the Project 8 experiment is to measure the absolute neutrino mass using tritium beta decays and a new spectroscopic technique, Cyclotron Radiation Emission Spectroscopy (CRES). The first phase of Project 8 demonstrated that CRES could be used to detect single-electron cyclotron radiation and perform precision electron spectroscopy. We are in Phase II of the experiment, performing a 100-day measurement of the endpoint of the tritium spectrum. We will demonstrate the ability to measure the last ~2 keV of the beta-decay spectrum and explore the background rate at energies just above the endpoint; CRES has the potential for extremely low backgrounds. In Phase III we will demonstrate the ability to scale up the volume of the experiment. In Phase IV we will switch the source from molecular tritium to atomic tritium, which will avoid systematic uncertainties from the final states of the molecule. I will present the current status of Project 8 Phase II and the plans for Phases III and IV.

Oblath, Noah↗

Project 8 apparatus for cyclotron radiation emission spectroscopy with 83m Kr and tritium

Cyclotron Radiation Emission Spectroscopy (CRES) is a novel technique for the precise measurement of relativistic electron energy. This technique is being employed by the Project 8 collaboration for measuring a high-precision tritium beta decay spectrum to perform a frequency-based measurement of the neutrino mass. In this work, we describe the Project 8 Phase II apparatus, used for the detection of the CRES signal from the conversion electrons of 83m Kr and the first CRES measurement of the beta-decay spectrum of molecular tritium.

Neutrino detectors↗

Josephson Traveling Wave Parametric Amplifiers to Enable Future Neutrino Mass Measurements

Technologies for “quantum sensing" have the promise of dramatically improved sensitivity in some experiments that explore nuclear physics at the boundaries of our current knowledge. In particular, the Josephson Traveling Wave Parametric Amplifier (JTWPA) could enable future experiments such as Project 8 that use Cyclotron Radiation Emission Spectroscopy (CRES) to measure the absolute neutrino mass scale in tritium beta decays. CRES consists of detecting a signal of approximately one femtowatt of power radiated by electrons trapped in a 1-T magnetic field. The frequency of that radiation, around 27 GHz for a tritium endpoint electron, is inversely proportional to the electron energy. One of the significant challenges of a CRES experiment is the detection of minimal signal power levels. State-of-the-art transistor-based technologies will not likely achieve sufficient signal-to-noise ratio (SNR) in a competitive neutrino mass experiment. However, emerging quantum technologies have been demonstrated to operate at the fundamental lower limits of noise permitted by the laws of quantum mechanics. Of those technologies, JTWPAs appear to satisfy future performance needs with speed gain, bandwidth, and very low noise. We propose to bring together a group of neutrino physicists, experts in the needs of future neutrino mass measurements, with leaders in the field of quantum information science and JTWPA technology to develop JTWPAs appropriate for neutrino mass measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microstructural Effects of High Dose Helium Implantation in ErD 2

Metal hydrides can store hydrogen isotopes with high volumetric density. In metal tritides, tritium beta decay can result in accumulation of helium within the solid, in some cases exceeding 10 at.% helium after only 4 years of aging. Helium is insoluble in most materials, but often does not readily escape, and instead coalesces to form nanoscale bubbles when helium concentrations are near 1 at.%. Blistering or spallation often occurs at higher concentrations. Radioactive particles shed during this process present a potential safety hazard. This study investigates the effects of high helium concentrations on erbium deuteride (ErD 2 ), a non-radioactive surrogate material for erbium tritide (ErT 2 ). To simulate tritium decay in the surrogate, high doses of 120 keV helium ions were implanted into ErD 2 films at room temperature. Scanning and transmission electron microscopy indicated spherical helium bubble formation at a critical concentration of 1.5 at.% and bubble linkage leading to nanoscale crack formation at a concentration of 7.5 at.%. Additionally, crack propagation occurred through the nanocrack region, resulting in spallation extending from the implantation peak to the surface. Electron energy loss spectroscopy was utilized to confirm the presence of high-pressure helium in the nanocracks, suggesting that helium gas plays a predominant role in deformation. This work improves the overall understanding of helium behavior in ErD 2 by using modern characterization techniques to determine: the critical helium concentration required for bubble formation, the material failure mechanism at high concentration, and the nanoscale mechanisms responsible for material failure in helium implanted ErD 2 .

36 MATERIALS SCIENCE↗

Coupled 2D MHD and runaway electron fluid simulations of SPARC disruptions

Runaway electrons (REs) generated during disruption events in tokamaks can carry mega-Ampère level currents, potentially causing damage to plasma-facing components. Understanding RE evolution during disruption events is important for evaluating strategies to mitigate RE damage. Using two-dimensional toroidally symmetric magnetohydrodynamic (MHD) simulations in M3D-C1, which incorporates a fluid RE model evolved self-consistently with the bulk MHD fluid, we examine the seeding and avalanching of REs during disruptions in the SPARC tokamak – a compact, high-field, high-current device designed to achieve a fusion gain Q > 2 in deuterium–tritium plasmas. The M3D-C1 simulations of unmitigated disruptions demonstrate RE plateau formation and peaking of the final current density, which agree well with the results of lower-fidelity reduced RE fluid models. This work provides the first systematic comparison and benchmarking of different primary sources, including activated tritium beta decay and Compton scattering, in SPARC disruption simulations with self-consistent MHD and RE coupling.

Compton scattering↗

Distributed Computing for the Project 8 Experiment

The Project 8 collaboration aims to measure the absolute neutrino mass or improve on the current limit by measuring the tritium beta decay electron spectrum. We present the current distributed computing model for the Project 8 experiment. Project 8 is in its second phase of data taking with a near continuous data rate of 1Gbps. The current computing model uses DIRAC (Distributed Infrastructure with Remote Agent Control) for its workflow and data management. A detailed meta-data assignment using the DIRAC File Catalog is used to automate raw data transfers and subsequent stages of data processing. The DIRAC system is deployed on containers managed using a Kubernetes cluster to provide a scalable infrastructure. A modified DIRAC Site Director provides the ability to submit jobs using Singularity on opportunistic High-Performance Computing (HPC) sites.

Distributed Computing, Kubernetes, DIRAC, Project ↗

Real-time signal detection for Cyclotron Radiation Emission Spectroscopy measurements using antenna arrays

Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for precision measurement of the energies of charged particles, which is being developed by the Project 8 Collaboration to measure the neutrino mass using tritium beta-decay spectroscopy. Project 8 seeks to use the CRES technique to measure the neutrino mass with a sensitivity of 40 meV, requiring a large supply of tritium atoms stored in a multi-cubic meter detector volume. Antenna arrays are one potential technology compatible with an experiment of this scale, but the capability of an antenna-based CRES experiment to measure the neutrino mass depends on the efficiency of the signal detection algorithms. Here, in this paper, we develop efficiency models for three signal detection algorithms and compare them using simulations from a prototype antenna-based CRES experiment as a case-study. The algorithms include a power threshold, a matched filter template bank, and a neural network based machine learning approach, which are analyzed in terms of their average detection efficiency and relative computational cost. It is found that significant improvements in detection efficiency and, therefore, neutrino mass sensitivity are achievable, with only a moderate increase in computation cost, by utilizing either the matched filter or machine learning approach in place of a power threshold, which is the baseline signal detection algorithm used in previous CRES experiments by Project 8.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Probing the Neutrino-Mass Scale with the KATRIN Experiment

The absolute mass scale of neutrinos is an intriguing open question in contemporary physics. The as-yet-unknown mass of the lightest and, at the same time, most abundant massive elementary particle species bears fundamental relevance to theoretical particle physics, astrophysics, and cosmology. The most model-independent experimental approach consists of precision measurements of the kinematics of weak decays, notably tritium β decay. With the KATRIN experiment, this direct neutrino-mass measurement has entered the sub-eV domain, recently pushing the upper limit on the electron-based neutrino mass down to 0.8 eV (90% CL) on the basis of first-year data out of ongoing, multiyear operations. Here, we review the experimental apparatus of KATRIN, the progress of data taking, and initial results. While KATRIN is heading toward the target sensitivity of 0.2 eV, other scientific goals are pursued. We discuss the search for light sterile neutrinos and an outlook on future keV-scale sterile-neutrino searches as well as further physics opportunities beyond the Standard Model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

KATRIN: status and prospects for the neutrino mass and beyond

Abstract The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to measure a high-precision integral spectrum of the endpoint region of T 2 β decay, with the primary goal of probing the absolute mass scale of the neutrino. After a first tritium commissioning campaign in 2018, the experiment has been regularly running since 2019, and in its first two measurement campaigns has already achieved a sub-eV sensitivity. After 1000 days of data-taking, KATRIN’s design sensitivity is 0.2 eV at the 90% confidence level. In this white paper we describe the current status of KATRIN; explore prospects for measuring the neutrino mass and other physics observables, including sterile neutrinos and other beyond-Standard-Model hypotheses; and discuss research-and-development projects that may further improve the KATRIN sensitivity.

beyond standard model↗

Zero-deadtime processing in beta spectroscopy for measurement of the non-zero neutrino mass

The Project 8 collaboration seeks to measure, or more tightly bound, the mass of the electron antineutrino by applying a novel spectroscopy technique to precisely measure the tritium beta-decay spectrum. The current system produces a single analog signal, which is digitized and processed in several stages before being saved to local disk storage. Online processing includes two stages, an FPGA connected to the analog to digital converter reduces the data down to the region of interest before shipping over the local network for further processing and storage. A normal CPU-based processing stage applies triggering logic to only save data at times when a signal is present, further reducing the total volume of data which needs to be written to disk or transferred for long-term storage. The next stage of the project will need to process many input channels and will integrate a necessary aggregation and combination step prior to applying the event search and triggering logic. We present the online processing system which has successfully been deployed for the current, singlechannel, phase. We also present the status and design for a many-channel platform.

Project 8 Collaboration↗

Suppression of Penning discharges between the KATRIN spectrometers

Abstract The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)-neutrino mass with a sensitivity of 0.2eV/c $$^2$$ 2 by precisely measuring the endpoint region of the tritium $$\beta $$ β -decay spectrum. It uses a tandem of electrostatic spectrometers working as magnetic adiabatic collimation combined with an electrostatic (MAC-E) filters. In the space between the pre-spectrometer and the main spectrometer, creating a Penning trap is unavoidable when the superconducting magnet between the two spectrometers, biased at their respective nominal potentials, is energized. The electrons accumulated in this trap can lead to discharges, which create additional background electrons and endanger the spectrometer and detector section downstream. To counteract this problem, “electron catchers” were installed in the beamline inside the magnet bore between the two spectrometers. These catchers can be moved across the magnetic-flux tube and intercept on a sub-ms time scale the stored electrons along their magnetron motion paths. In this paper, we report on the design and the successful commissioning of the electron catchers and present results on their efficiency in reducing the experimental background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Logical approach to tritium vacuum pump selection for fusion applications

Vacuum pumps have been used for tritium processing since the 1940s following the isolation of pure tritium. The largest problem facing tritium vacuum pumps is the tritium radioactive decay. The beta particles, recoil energy, and subsequent radical formations are detrimental to most carbon-based materials. Carbon materials, such as plastics, elastomers, carbon fiber, activated carbon, etc., react with tritium to form methane and in the process strip material from the carbonbased material. Other reactions can be self-catalyzing, as is the case with nitrogen and tritium forming tritiated ammonia at room temperature and pressure. Tritium also readily isotopically exchanges with surface -OH groups, increasing the amount of protium in the gas stream while creating a tritium holdup on the surface. Metals are the preferred material when working with tritium, but tritium will permeate into and through almost all metals at some point. The entrapped tritium can decay inside the metal, creating local helium distortions that can impact the structural properties above and beyond the hydrogen embrittlement issue tritium can cause.

Angelette, Lucas M. [Savannah River National Labor↗

Low Activity Tritium Detection in CCDs Using Deep Learning Techniques

Here, this study explores the use of charge-coupled devices (CCDs) for detecting low-energy beta particles from tritium decay - a critical signal for nuclear safety, nuclear nonproliferation, and environmental monitoring. We employ a dual approach utilizing both measured CCD data and detailed Geant4 simulations. Our analysis compares classical techniques with advanced deep learning methods, including convolutional neural networks (CNNs), autoencoders trained exclusively on tritium data, and preliminary studies on boosted decision trees (BDTs). The CNN, trained on mixed signal/background datasets, demonstrates superior classification performance, while the autoencoder shows the potential of unsupervised, background-agnostic strategies when background characteristics are poorly defined. These results highlight the excellent sensitivity achievable thanks to the background rejection made possible by information-rich CCD data, paving the way for improved portable tritium monitoring.

Autoencoder↗

Wideband precision stabilization of the -18.6kV retarding voltage for the KATRIN spectrometer

The Karlsruhe Tritium Neutrino Experiment (KATRIN) measures the effective electron anti-neutrino mass with an unprecedented design sensitivity of 0.2 eV (90 % C.L.). In this experiment, the energy spectrum of beta electrons near the tritium decay endpoint is analyzed with a highly accurate spectrometer. To reach the KATRIN sensitivity target, the retarding voltage of this spectrometer must be stable to the ppm (1 × 10 -6 ) level and well known on various time scales (μs up to months), for values around -18.6 kV. A custom-designed high-voltage regulation system mitigates the impact of interference sources in the absence of a closed electric shield around the large spectrometer vessel. In this article, we describe the regulation system and its integration into the KATRIN setup. Independent monitoring methods demonstrate a stability within 2 ppm, exceeding KATRIN's specifications.

47 OTHER INSTRUMENTATION↗

Tritiated Sulfur Hexafluoride Disposition Strategies

Tritium (T 2 ) is a radioactive isotope of hydrogen that is produced in nuclear fission reactions and is often used in nuclear fusion reactions and accelerator-based applications for medical isotope production. As a hydrogen isotope, tritium can readily bind to hydroxyl radicals (OH), forming tritiated water (HTO or T 2 0), and to carbon atoms. Tritium decays to helium-3 ( 3 He) via beta-decay with max decay energy of 18.6 keV. While it is not an external radiation hazard, it can be an internal radiation hazard if tritium is inhaled, ingested, or absorbed through the skin. In applications where tritium is handled, tritium confinement is performed using different barriers to minimize releases to the environment. For gaseous (elemental), liquid (oxide), and metal (hydride) tritium, process piping and components provide the primary confinement function. Secondary tritium confinement is typically provided by inert (i.e. non-flammable gases such as nitrogen, argon, or helium) gloveboxes which are connected to a tritium stripper system. Primary tritium confinement barriers typically produce low volumes of high tritium concentrations of tritiated methane from carbon in steels or organic materials along with tritiated water/tritium oxide (e.g. HTO) and tritiated ammonia from reactions with oxygen and nitrogen. Tritium escaping primary confinement into secondary confinement atmospheres (e.g. gloveboxes) produce higher volumes of lower activity contamination than found in process piping. Tritium contamination also occurs by leaks or tritium permeation/diffusion through confinement materials. Tritium from inside primary confinement barriers will diffuse or leak out of the primary confinement barrier and usually into the air, if the system is inside an air hood or ventilated hot cell, or into the secondary confinement (e.g. glovebox) atmosphere which is either exhausted or stripped based on the function of the secondary confinement (glovebox) system. Accelerator based processes for medical isotope production represent an atypical tritium contamination challenge. In medical isotope production, deuterium supply gas is ionized and accelerated to a tritium gas target to produce neutrons that are then used to produce the medical isotopes through additional nuclear fission reactions. To create large voltage differentials for accelerator operations, an electrical insulation medium is needed to prevent or rapidly quench electric discharges. A common electrical insulation medium utilized in accelerator applications is sulfur hexafluoride (SF 6 ) gas. SF 6 has a high dielectric strength and allows for the construction of smaller accelerator systems compared to other electrical insulation mediums such as air or dry nitrogen. Due to tritium permeation/diffusion through accelerator process and confinement materials, there is the possibility that tritium can contaminate the electrical insulation medium of the accelerator. Tritium contaminated SF 6 creates a material without any obvious processes for managing the contamination, reuse, or disposal of the used SF 6 . This document will discuss possible management strategies for tritium contaminated SF 6 for accelerator-based processes for Molybdenum-99 (Mo-99) production.

07 ISOTOPE AND RADIATION SOURCES↗

Cyclotron radiation emission spectroscopy of electrons from tritium $β$ decay and 83m Kr internal conversion

Project 8 has developed a novel technique, cyclotron radiation emission spectroscopy (CRES), for direct neutrino mass measurements. A CRES-based experiment on the beta spectrum of tritium has been carried out in a small-volume apparatus. Here, we provide a detailed account of the experiment, focusing on systematic effects and analysis techniques. In a Bayesian (frequentist) analysis, we measure the tritium endpoint as ${18}$ ${553}_{—19}^{+18}$ (${18}$ ${548}_{—19}^{+19}$) eV and set upper limits of 155 (152) eV (90% C.L.) on the neutrino mass. No background events are observed beyond the endpoint in 82 days of running. We also demonstrate an energy resolution of 1.66 ± 0.19 eV in a resolution-optimized magnetic trap configuration by measuring 83m Kr 17.8-keV internal-conversion electrons. These measurements establish CRES as a low-background, high-resolution technique with the potential to advance neutrino mass sensitivity

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tritium Betavoltaic Powered Sensor Platforms: Power Augmentation with Scintillating Particles

Betavoltaics (BV) are long-life power sources that typically convert beta particle radiation into electricity. Largely, the radioactive decays within the source go unharvested by the device. This work seeks to augment the power generation of BV devices by integration of scintillating particles within the radiative getter to convert beta emission which would otherwise not leave the getter into usable light for power generation. Silica-covered barium fluoride scintillating particles were integrated into a tritiated water getter. Power generation was increased from 100s of nW to µW levels with the addition of 0.2 wt. % particles into the getter. Nanowatt-scale sensor platforms were demonstrated with the µW BV devices and the maximum possible lifetime of such platforms was estimated. As this technique enables higher power density BV devices from conventional Si semiconductors (compared to wider bandgap BVs), the further implementation may lower the barrier-to-deployment of these long-life power/sensor platforms.