Acousto-optic tunable filter.
Electronically tunable lithium niobate optical filter utilizing collinear acousto-optic diffraction in anisotropic medium
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Electronically tunable lithium niobate optical filter utilizing collinear acousto-optic diffraction in anisotropic medium
Liquid crystal tunable filters are useful in building compact multi-spectral instruments. The system is portable and adaptable for use in a variety of fields of study in the visible and near-infrared regions of the spectrum.We will present data from calibration targets and some applications, results of the spectral calibration of a spectrometer system, and results of environmental (vibration, radiation, shock, and thermal) testing. Data acquisition and system design are also discussed.
An acousto-optic tunable filter (AOTF) is employed to generate a display by driving the AOTF with a RF electrical signal comprising modulated red, green, and blue video scan line signals and scanning the AOTF with a linearly polarized, pulsed light beam, resulting in encoding of color video columns (scan lines) of an input video image into vertical columns of the AOTF output beam. The AOTF is illuminated periodically as each acoustically-encoded scan line fills the cell aperture of the AOTF. A polarizing beam splitter removes the unused first order beam component of the AOTF output and, if desired, overlays a real world scene on the output plane. Resolutions as high as 30,000 lines are possible, providing holographic display capability.
An acousto-optic tunable filter (AOTF) is employed to generate a display by driving the AOTF with a RF electrical signal comprising modulated red, green, and blue video scan line signals and scanning the AOTF with a linearly polarized, pulsed light beam, resulting in encoding of color video columns (scan lines) of an input video image into vertical columns of the AOTF output beam. The AOTF is illuminated periodically as each acoustically-encoded scan line fills the cell aperture of the AOTF. A polarizing beam splitter removes the unused first order beam component of the AOTF output and, if desired, overlays a real world scene on the output plane. Resolutions as high as 30,000 lines are possible, providing holographic display capability.
In this presentation, we introduce phase-change tunable filters (PCTFs), which are capable of actively tunable spectral filtering as well as continuous tuning (hyperspectral) across multiple IR wavebands (1–10 μm); several orders-of-magnitude faster switching speeds (GHz–MHz) than the state-of-the-art, and narrowband filtering (~50 nm passband). This technology subsystem is based on the unique electro-optics of non-volatile, phase-change materials (PCMs) such as GeSbTe and SbS. PCMs exhibit a large, reversible refractive index shift through applied energetic pulses. By integrating PCMs with established optical filter designs—whose optical properties are strongly dependent on the constituent materials’ refractive indices—we can rapidly and reversibly tune the PCTFs center wavelength (passband).
.A spectral imager for astronomy and aeronomy has been fabricated using collinear or non-collinear acoustooptic tunable filters (AOTFs). The AOTF provides high transparency, rapid tunability over a wide wavelength range, a capability of varying the bandwidth by more than an order of magnitude, high etendue, and linearly polarized output. Some typical observational applications of acoustooptic tunable filters used in several configurations at astronomical telescopes are demonstrated.
Surface plasmon tunable filter (SPTF) is a new technology invented in Jet Propulsion Lab. When a white light is incident on a metal/air/metal structure, in certain condition, surface plasmon waves can be excited at one metal/air material interface; those photons in surface plasmon resonances wavelength range will be converted into the energy of free electrons in the metal than coupled into the other metal film, and re-radiate out the color light.
A demonstration imaging spectrometer using a liquid crystal tunable filter (LCTF) was built and tested on a hot air balloon platform. The LCTF is a tunable polarization interference or Lyot filter. The LCTF enables a small, light weight, low power, band sequential imaging spectrometer design.
Now a prototype of surface plasmon tunable filter has been fabricated at JPL, and the experiment measurement will be discussed in this paper.
A spectrometer design is introduced which combines an acoustooptic tunable filter (AOTF) and IR-transmitting flouride-glass fibers. The AOTF crystal is fabricated from TeO2 and permits random access to any wavelength in less than 50 microseconds, and the resulting spectrometer is tested for the remote analysis of gases and hydrocarbons. The AOTF spectrometer, when operated with a high-speed frequency synthesizer and optimized algorithms, permits accurate high-speed spectroscopy in the mid-IR spectral region.
We are developing a micro-machined electrostatically actuated Fabry-Perot tunable filter with a large clear aperture for application in high through-put wide-field imaging spectroscopy and lidar systems. In the first phase of this effort, we are developing key components based on coupled electro-mechanical simulations. In particular, the movable etalon plate design leverages high coating stresses to yield a flat surface in drum-head tension over a large diameter (12.5 mm). In this approach, the cylindrical silicon movable plate is back etched, resulting in an optically coated membrane that is suspended from a thick silicon support ring. Understanding the interaction between the support ring, suspended membrane, and coating is critical to developing surfaces that are flat to within stringent etalon requirements. In this work, we present the simulations used to develop the movable plate, spring suspension system, and electrostatic actuation mechanism. We also present results from tests of fabricated proof of concept components.
Imaging spectrometer constructed from charged-coupled-device video camera; liquid-crystal tunable filter (LCTF) placed in front of camera lens; and associated digital and analog control, signal-processing, and data-processing circuits. To enable operation of instrument in specific application for which designed (balloon flights in cold weather), camera and LCTF surrounded by electric heating pad. Total operating power, excluding that consumed by heating pad, 16 W. Instrument weighs 4.5 kg.
Phase change material (PCM)-based actively tunable mid-wave IR filters have broad imaging and sensing applications—from probing molecular vibrations in chemical species to detecting radiant thermal signatures. We introduce the Phase-change actively tunable filter (P-ACTIVE) project lead by NASA Langley Research Center with collaborators MIT and the University of Cambridge. It covers background science, experimental and theoretical device performance, as well as recent results obtained from a MISSE-14 mission for space qualification of active metasurface optics and constituent PCM. We conclude with a prospective view of the technology and discuss the potential for these filters to serve multiple NASA missions.
We demonstrate tunable optical filters fabricated from metalized lithium niobate disk resonators and discuss further applications of the resonator chains for tunable photonic delay lines.
A remote sensing multispectral imaging instrument is being developed that uses a high resolution, fast programmable acoustooptic tunable filter (AOTF) as the spectral bandpass filter. A compact and fully computer controllable AOTF-based imaging spectrometer that operates in the visible wavelength range (0.5-0.8 microns) has been built and tested with success. A second imaging spectrometer operating in the near-infrared wavelength range (1.2-2.4 microns) is also under experimental investigation. The design criteria meeting various system issues, such as imaging quality, spectral response, and field of view (FOV), are discussed. An experiment using this AOTF imaging spectrometer breadboard is described.
In this paper, recent progress made in the development of quartz and KDP crystal based acousto-optic tunable filters (AOTF) are presented. These AOTFs are developed for operation over deep-UV to near-UV wavelengths of 190 nm to 400 nm. Preliminary output performance measurements of quartz AOTF and design specifications of KDP AOTF are presented. At 355 nm, the quartz AOTF device offered approx.15% diffraction efficiency with a passband full-width-half-maximum (FWHM) of less than 0.0625 nm. Further characterization of quartz AOTF devices at deep-UV wavelengths is progressing. The hermetic packaging of KDP AOTF is nearing completion. The solid-state optical sources being used for excitation include nonlinear optics based high-energy tunable UV transmitters that operate around 320 nm and 308 nm wavelengths, and a tunable deep-UV laser operating over 193 nm to 210 nm. These AOTF devices have been developed as turn-key devices for primarily for space-based chemical and biological sensing applications using laser induced Fluorescence and resonance Raman techniques.
The James Webb Space Telescope (JWST) will carry four scientific instruments, one of which is the Tunable Filter Imager (TFI), which is an instrument within the Fine Guidance Sensor. The Dual Wheel (DW) mechanism is being designed, built and tested by COM DEV Ltd. under contract from the Canadian Space Agency. The DW mechanism includes a pupil wheel (PW) holding seven coronagraphic masks and two calibration elements and a filter wheel (FW) holding nine blocking filters. The DW mechanism must operate at both room temperature and at 35K. Successful operation at 35K comprises positioning each optical element with the required repeatability, for several thousand occasions over the five year mission. The paper discusses the results of testing geared motors and bearings at the cryogenic temperature. In particular bearing retainer design and PGM-HT material, the effects of temperature gradients across bearings and the problems associated with cooling mechanisms down to cryogenic temperatures. The results of additional bearing tests are described that were employed to investigate an abnormally high initial torque experienced at cryogenic temperatures. The findings of these tests, was that the bearing retainer and the ball/race system could be adversely affected by the large temperature change from room temperature to cryogenic temperature and also the temperature gradient across the bearing. The DW mechanism is now performing successfully at both room temperature and at cryogenic temperature. The life testing of the mechanism is expected to be completed in the first quarter of 2010.
This paper discusses recent activities of Jet Propulsion Laboratory (JPL) in the development of a new type of remote sensing multispectral imaging instruments using acousto-optic tunable filter (AOTF) as programmable bandpass filter. This remote sensor provides real-time operation; observational flexibility; measurements of spectral, spatial, and polarization information using a single insturment; and compact, solid state structure without moving parts.