Search NASA⌕ Search

SEARCH · Search NASA

Results for “tunable transition temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Impact of Thermochromic Coatings on Thermal Management for Human Spacecraft Applications

Thermochromic variable emittance coatings (VECs) allow for passive, dynamic thermal management of space vehicles due to their temperature dependent optical properties. Ideally, a thermochromic material should exhibit low mid-IR emissivity for lower temperatures and switch to high mid-IR emissivity for higher temperatures; one promising material that demonstrates these characteristics is Lanthanum Strontium Manganite (LSM). The transition temperatures of LSM are dependent on the Lanthanum-to-Strontium ratio x, La1-xSrxMnO3. La0.8Sr0.2MnO3, which has an emittance of 0.5 for < 270 K, then a linear increase in emittance to 0.8 over an increase of 70 K where it will saturate at ~340K, is commonly utilized but this is tunable by changing the Sr concentration. The tunability of the transition temperature range of LSM motivates a need to understand the optimal thermal transition range for human spacecraft. Additionally, LSM has high solar absorptance and to combat this issue the VEC will be micropatterned on top of a highly solar reflective layer of Barium Sulfate (BaSO4). Consequently, this work will elucidate the tradeoffs between solar absorptance and variable emittance for this technology since the micropattern adversely couples the solar absorptance to the mid-IR emittance. This work develops a computational model using Thermal Desktop to study the utility of VECs on human spacecraft, such as Orion, subjected to mission phases such as lunar transit and Gateway docking. The model considers both external heat loads, from solar irradiation and planetary IR, as well as vehicle heat loads, from avionics and crew, as an input into the body mounted thermochromic radiators. There are several design targets for VECs, i.e. achieving the largest change in emittance, finding the optimal temperature range for the transition, and achieving the highest emittance in the high temperature phase. This work prioritizes these design targets for LSM to achieve the optimal heat rejection for a human spacecraft. The VECs are compared with static emittance coatings and the efficiency gains are quantified. Thermochromic VECs will ultimately lead to simplifications of active cooling systems which synergistically correlates to mass reduction and less energy consumption for space vehicles.

Joseph Peoples↗

Line-width temperature dependence of selected R-branch transitions in the nu-3 fundamental of (N-14)2O-16 between 135 and 295 K

Tunable diode laser spectroscopy has been used to measure the temperature dependence of N2 foreign gas broadening coefficients for eight R-branch transitions in the nu-3 fundamental of (N-14)2O-16 at 135, 176, 210, and 295 K. The exponent n of the relation for quadrupole-quadrupole collisional interactions is found to range from 0.66 to 0.71, in approximate agreement with the theoretically predicted value of 0.75.

Loewenstein, Max↗

Efficient CW diode-pumped Tm, Ho:YLF laser with tunability near 2.067 microns

A conversion efficiency of 42 percent and slope efficiency of approximately 60 percent relative to absorbed pump power are reported from a continuous wave diode-pumped Tm, Ho:YLF laser at 2 microns with output power of 84 mW at sub-ambient temperatures. The emission spectrum is etalon tunable over a range of 16/cm centered on 2.067 microns, with fine tuning capability of the transition frequency with crystal temperature at a measured rate of about -0.03/cm-K. The effective emission cross section is measured to be 5 x 10 exp -21 sq cm. These and other aspects of the laser performance are discussed in the context of calculated atmospheric absorption characteristics in this spectral region and potential use in remote sensing applications.

Mcguckin, B. T.↗

Tunable diode laser measurements of air-broadened linewidths in the nu6 band of H2O2

Air-broadened half-widths of 18 transitions in the nu6 band of H2O2 between 1252/cm and 1291/cm have been determined from spectra recorded at room temperature using a tunable diode laser spectrometer. The preparation of the H2O2 gas samples for the measurements is described, and the data analysis is discussed, including the derivation of Lorentz broadening coefficients and the contribution of molecular collisions to the measured Lorentz half-widths. For the 18 transitions, the half-widths varied from 0.0923/cm/atm to 0.1155/cm/atm at 296 K, with a mean value of 0.1020/cm/atm. An error of less than 10 percent is estimated for these results.

Malathy Devi, V.↗

Measurements of (C-12)H4 nu-4 band halfwidths using a tunable diode laser system and a Fourier transform spectrometer

Air-broadened and N2-broadened halfwidths at room temperature for twenty-five transitions in the nu-4 fundamental band of (C-12)H4 have been determined from IR absorption spectra recorded with a tunable diode laser spectrometer. Two tunable diode lasers operating in the 1250-1380-kayser region were used to obtain these data. Air-broadened halfwidths for twenty of these lines were also determined from additional spectra recorded at 0.01-kayser resolution with the Fourier transform spectrometer in the McMath solar telescope complex on Kitt Peak. The air-broadened halfwidths obtained from these two techniques are very consistent with agreement better than 3 percent in most cases.

Devi, V. M.↗

Tunable diode laser-pumped Tm,Ho:YLF laser operated in continuous-wave and Q-switched modes

Tunable continuous-wave and pulsed laser output was obtained from a Tm-sensitized Ho:YLiF4 crystal at subambient temperatures when longitudinally pumped with a diode laser array. A conversion efficiency of 42 percent and slope efficiency of approximately 60 percent relative to the absorbed pumped power have been achieved at a crystal temperature of 275 K. The emission spectrum was etalon tunable over a range of 16/cm centered at 2067 nm with fine tuning capability of the transition frequency with crystal temperature at measured rate of -0.03/cm/K. Output energies of 0.22 mJ per pulse and 22 ns pulse duration were recorded at Q-switch frequencies that correspond to an effective upper laser level lifetime of 6 ms, and a pulse energy extraction efficiency of 64 percent.

Mcguckin, B. T.↗

Tunable CW diode-pumped Tm,Ho:YLiF4 laser operating at or near room temperature

A conversion efficiency of 42% and slope efficiency of 60% relative to absorbed pump power are obtained from a continuous wave diode-pumped Tm,Ho:YLiF4 laser at 2 microns with output power of 84 mW at a crystal temperature of 275 K. The emission spectrum is etalon tunable over a range of7 nm (16.3/cm) centered on 2.067 microns with fine tuning capability of the transition frequency with crystal temperature at a measured rate of -0.03/(cm)K. The effective emission cross-section is measured to be 5 x 10(exp -21) cm squared. These and other aspects of the laser performance are disclosed in the context of calculated atmospheric absorption characteristics in this spectral region and potential use in remote sensing applications. Single frequency output and frequency stabilization are achieved using an intracavity etalon in conjunction with an external reference etalon.

Mcguckin, Brendan T.↗

Simultaneous determination of rotational and translational temperatures of OH/2 Pi/ in a gas discharge

A simultaneous determination of the rotational and translational temperatures of OH(2 Pi) in a water-vapor discharge is reported. These temperatures were determined by measuring the strength and line shape of the absorption lines in the 2 Pi (v = 0) - 2 Sigma(+) (v = 0) transitions of OH using a CW tunable laser. It was found that the rotational distribution was thermalized, but the corresponding rotational temperature was much lower than the translational temperature. Possible implications of these results are discussed.

Wang, C. C.↗

Tunable CW diode-pumped Tm,Ho:YLiF4 laser operating at or near room temperature

A conversion efficiency of 42 percent and slope efficiency of 60 percent relative to absorbed pump power are obtained from a continuous wave diode-pumped Tm,Ho:YLiF4 laser at 2 microns with output power of 84mW at a crystal temperature of 275K. The emission spectrum is etalon tunable over a range of 7nm (16.3 cm(sup -1) centered on 2.067 microns with fine tuning capability of the transition frequency with crystal temperature at a measured rate of -0.03/(cm)K. The effective emission cross-section is measured to be 5 x 10(sup -21) cm squared. These and other aspects of the laser performance are disclosed in the context of calculated atmospheric absorption characteristics in this spectral region and potential use in remote sensing applications. Single frequency output and frequency stabilization are achieved using an intracavity etalon in conjunction with an external reference etalon.

Mcguckin, Brendan T.↗

Photodissociation of Peroxynitric Acid in the Near-IR

Temperature-dependent near-IR photodissociation spectra were obtained for several vibrational overtone transitions of peroxynitric acid (HNO4) with a tunable OPO photolysis/OH laser-induced-fluorescence system. Band-integrated photodissociation cross-sections (definity integral of sigma(sub diss)), determined relative to that for the 3nu(sub 1), OH stretching overtone, were measured for three dissociative bands. Assuming unit quantum efficiency for photodissociation of 3nu(sub 1), we find 2nu(sub 1) + nu(sub 3)(8242/cm) = (1.21 x 10(exp -20) (independent of temperature), 2nu(sub 1) (6900/cm) = 4.09 x 10(exp 18) * e(sup (-826,5/T)) (295 K greater than T greater than 224 K), and nu(sub 1) + 2nu(sub 3) (6252/cm) = 1.87 x 10(exp -19) * e(sup (- 1410.7/T)) (278 K greater than T greater than 240 K) sq cm/molecule cm. The photodissociation cross-sections are independent of pressure over the range 2 to 40 Torr. Temperature-dependent quantum yields (phi) for these transitions were obtained using integrated absorption cross-sections (definity integral of sigma(sub abs)) of HNO4 overtone vibrations measured with a FTIR spectrometer. In the atmosphere, photodissociation in the infrared is dominated by excitation of the first overtone of the OH stretching vibration (2nu((sub 1)). Inclusion of all dissociative HNO4 overtone and combination transitions yields a daytime IR photolysis rate of approximately 1 x 10(esp -1)/s. This process significantly shortens the estimated lifetime of HNO4 in the upper troposphere and lower stratosphere.

Roehl, Coleen M.↗

Kinetic Temperature and Electron Density Measurement in an Inductively Coupled Plasma Torch using Degenerate Four-Wave Mixing

Laser wave mixing is presented as an effective technique for spatially resolved kinetic temperature measurements in an atmospheric-pressure radio-frequency inductively-coupled plasma. Measurements are performed in a 1 kW, 27 MHz RF plasma using a continuous-wave, tunable 811.5-nm diode laser to excite the 4s(sup 3)P2 approaches 4p(sup 3)D3 argon transition. Kinetic temperature measurements are made at five radial steps from the center of the torch and at four different torch heights. The kinetic temperature is determined by measuring simultaneously the line shape of the sub-Doppler backward phase-conjugate degenerate four-wave mixing and the Doppler-broadened forward-scattering degenerate four-wave mixing. The temperature measurements result in a range of 3,500 to 14,000 K+/-150 K. Electron densities measured range from 6.1 (+/-0.3) x 10(exp 15)/cu cm to 10.1 (+/-0.3) x 10(exp 15)/cu cm. The experimental spectra are analyzed using a perturbative treatment of the backward phase-conjugate and forward-geometry wave-mixing theory. Stark width is determined from the collisional broadening measured in the phase-conjugate geometry. Electron density measurements are made based on the Stark width. The kinetic temperature of the plasma was found to be more than halved by adding deionized water through the nebulizer.

Schafer, Julia↗

Calibration of a tunable excimer laser using the optogalvanic effect

A device for the calibration of a tunable excimer laser is currently under development. The laser provides UV radiation at three principal wavelengths, 193, 248, and 308 nm and is tunable over a range of 1 nm at each of these wavelengths. The laser is used as a non-intrusive optical probe to excite electronic transitions, and thereby induce fluorescence, of the principle molecules or atoms of interest in supersonic flowfields, both reacting and nonreacting. The fluorescence resulting from the excitation is observed with an intensified camera. Over the range of tunability at the three wavelengths are a number of transitions that can be observed. The intensity of the fluorescence depends in part on the local temperature and density. The nature of this thermodynamic dependence is variable among transitions; thus, identification of the transition under observation is required. The specific transition excited corresponds directly to the wavelength of the radiation. The present technique used for transition identification consists of scanning the laser across the range of tunability and observing the fluorescence resulting from various molecular transitions.

Abbitt, John D.↗

Absolute intensities for the Q-branch of the 3 nu(sub 2) (-) nu(sub 1) (465.161/cm) band of nitrous oxide

The absolute intensities of four lines, Q 15-Q 18 in the 03(sup 1)0-10(sup 0)0 band, of N2O have been measured using a tunable diode laser spectrometer at temperatures between 380 and 420 K and pressures between 4 and 15 torr. Even though these transitions are weak and produced only about 2% of absorption at the line center for a pathlength of 52 m, they were measured with a signal to noise ratio of about 20 due to the high sensitivity of the instrument. The band strength derived is 1.03 x 10(exp -24) cm/molec at 296 K.

Sirota, J. Marcos↗

Absolute intensities and foreign gas broadening coefficients of the 11(sub 1,10) from 11(sub 2,10) and 18(sub 0,18) from 18(sub 1,18) lines in the nu(sub 7) band of C2H4

Absolute intensities and foreign gas broadening coefficients of the 18(sub 0,18) from 18(sub 1,18) and 11(sub 1,10) from 11(sub 2,10) transitions in the nu(sub 7) band of C2H4 near 948/cm have been measured at a spectral resolution of approximately 5 x 10(exp -4)/cm using tunable diode laser spectrometry. Ar, He, N2, O2 were used as the broadening gases. In order to determine the temperature dependence of the broadening coefficient, data were obtained at temperatures ranging from 150 to 296 K. The absolute intensity of the 5(sub 0,5) from 5(sub 1,5) transition was also found at 296 K. A band strength of 330 +/- 10/sq cm/atm was obtained from weighted averages of the individual line intensities and a rigid asymmetric top calculation.

Reuter, Dennis C.↗

Optical Characterization and 2,525 micron Lasing of Cr(2+):Cd(0.85)Mn(0.15)Te

Transition metal doped solids are of significant current interest for the development of tunable solid-state lasers for the near and mid-infrared (1-4 pm) spectral region. Applications of these lasers include basic research in atomic, molecular, and solid-state physics, optical communication, medicine, and environmental studies of the atmosphere. In transition metal based laser materials, absorption and emission of light arises from electronic transitions between crystal field split energy levels of 3d transition metal ions. The optical spectra generally exhibit broad bands due to the strong interaction between dopant and host (electron-phonon coupling). Broad emission bands offer the prospect of tunable laser activity over a wide wavelength range, e.g. the tuning range of Ti:Sapphire extends from 700-1100 run. The only current transition metal laser operating in the mid-infrared wavelength region (1.8-2.4 micro-m) is CO(2+):MgF2, but its performance is severely limited due to strong nonradiative decay at room temperature. Based on lifetime data, the quantum efficiency is estimated to be less than 3 deg/0 11,21. In general, the probability for non-radiative decay via multi-phonon relaxation increases with decreasing energy gap between ground and excited state. Therefore, efficient transition metal lasers beyond -1.6 micro-m are rare. Recently, tunable laser activity around 2.3 micro-m was observed from Cr doped ZnS and ZnSe. The new lasing center in these materials was identified as Cr(2+) occupying the tetrahedral Zn site. Tetrahedrally coordinated optical centers are rather unusual among transition metal lasers. Their potential usefulness, however, has been demonstrated by the recent development of near infrared laser materials such as Cr:forsterite and Cr:YAG, which are based on tetrahedrally coordinated Cr(4+) ions. According to the Laporte selection rule, electric-dipole transition within the optically active 3d-electron shells are parity forbidden. However, a static acentric electric crystal field or the coupling of asymmetric phonons can force electric-dipole transitions by the admixture of wave functions with opposite parity. Tetrahedral sites lack inversion symmetry which provides the odd-parity field necessary to relax the parity selection rule. Therefore, high absorption and emission cross sections are observed. An enhanced radiative emission rate is also expected to reduce the detrimental effect of non-radiative decay. Motivated by the initial results on Cr doped ZnS and ZnSe, we have started a comprehensive effort to study Cr(2+) doped II-VI semiconductors for solid-state laser applications. In this paper we present the optical properties and the demonstration of mid-infrared lasing from Cr doped Cd(0.85)Mn(0.15)Te.

Davis, V. R.↗

Heterodyne detection of the 752.033-GHz H2O rotational absorption line

A tunable high resolution two stage heterodyne radiometer was developed for the purpose of investigating the intensity and lineshape of the 752.033 GHz rotational transition of water vapor. Single-sideband system noise temperatures of approximately 45,000 K were obtained using a sensitive GaAs Schottky diode as the first stage mixer. First local oscillator power was supplied by a CO2 laser pumped formic acid laser (761.61 GHz), generating an X-band IF signal with theoretical line center at 9.5744 GHz. Second local oscillator power was provided by means of a 3 GHz waveguide cavity filter with only 9 dB insertion loss. In absorption measurements of the H2O taken from a laboratory simulation of a high altitude rocket plume, the center frequency of the 752 GHz line was determined to within 1 MHz of the reported value. A rotational temperature 75 K, a linewidth 5 MHz and a Doppler shift 3 MHz were measured with the line-of-sight intersecting the simulated-plume axis at a distance downstream of 30 nozzle diameters. These absorption data were obtained against continuum background radiation sources at temperatures of 1175 and 300 K.

Dionne, G. F.↗

Space Launch System Base Heating Test: Tunable Diode Laser Absorption Spectroscopy

This paper describes the Tunable Diode Laser Absorption Spectroscopy (TDLAS) measurement of several water transitions that were interrogated during a hot-fire testing of the Space Launch Systems (SLS) sub-scale vehicle installed in LENS II. The temperature of the recirculating gas flow over the base plate was found to increase with altitude and is consistent with CFD results. It was also observed that the gas above the base plate has significant velocity along the optical path of the sensor at the higher altitudes. The line-by-line analysis of the H2O absorption features must include the effects of the Doppler shift phenomena particularly at high altitude. The TDLAS experimental measurements and the analysis procedure which incorporates the velocity dependent flow will be described.

Parker, Ron↗

Space Launch System Base Heating Test: Tunable Diode Laser Absorption Spectroscopy

This paper describes the Tunable Diode Laser Absorption Spectroscopy (TDLAS) measurement of several water transitions that were interrogated during a hot-fire testing of the Space Launch Systems (SLS) sub-scale vehicle installed in LENS II. The temperature of the recirculating gas flow over the base plate was found to increase with altitude and is consistent with CFD results. It was also observed that the gas above the base plate has significant velocity along the optical path of the sensor at the higher altitudes. The line-by-line analysis of the H2O absorption features must include the effects of the Doppler shift phenomena particularly at high altitude. The TDLAS experimental measurements and the analysis procedure which incorporates the velocity dependent flow will be described.

Parker, Ron↗