Enhanced Models for the Simulation of Two-Phase Boiling Flow and Critical Heat Flux with the STAR-CCM+ and NEK-2P CFD Codes: Executive Summary (Final Report)

The goal of the project was to develop, verify and validate an advanced two-phase boiling flow modeling capability that enhances the existing two-phase flow modeling of the STAR-CCM+ Computational Fluid Dynamics (CFD) code. The project focused on the simulation of two phase flow and heat transfer phenomena that occur in Boiling Water Reactor (BWR) and Pressurized Water Reactor (PWR) fuel bundles under various operating conditions. The extended STAR-CCM+ two-phase flow models implemented during the project follow the approach similar to the Extended Boiling Framework [1-6] previously developed at Argonne but include more fundamental physical models of boiling phenomena. The development and validation of the extended two-phase models is supported by the U.S. DOE GAIN program and performed in collaboration with Framatome U.S. Inc.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of CFD Methods for Simulation of Two-Phase Boiling Flow Phenomena in a Helical Coil Steam Generator

The U.S. Department of Energy, Office of Nuclear Energy charges participants in the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program with the development of advanced modeling and simulation capabilities that can be used to address design, performance and safety challenges in the development and deployment of advanced reactor technology. The NEAMS has established a high impact problem (HIP) team to demonstrate the applicability of these tools to identification and mitigation of sources of steam generator flow induced vibration (SGFIV). The SGFIV HIP team is working to evaluate vibration sources in an advanced helical coil steam generator using computational fluid dynamics (CFD) simulations of the turbulent primary coolant flow over the outside of the tubes and CFD simulations of the turbulent multiphase boiling secondary coolant flow inside the tubes integrated with high resolution finite element method assessments of the tubes and their associated structural supports. This report summarizes the demonstration of a methodology for the multiphase boiling flow analysis inside the helical coil steam generator tube. A helical coil steam generator configuration has been defined based on the experiments completed by Polytecnico di Milano in the SIET helical coil steam generator tube facility. Simulations of the defined problem have been completed using the Eulerian-Eulerian multi-fluid modeling capabilities of the commercial CFD code STAR-CCM+. Simulations suggest that the two phases will quickly stratify in the slightly inclined pipe of the helical coil steam generator. These results have been successfully benchmarked against both empirical correlations for pressure drop and simulations using an alternate CFD methodology, the dispersed phase mixture modeling capabilities of the open source CFD code Nek5000.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Impact of dissolved salts on two-phase flow and boiling heat transfer in a natural circulation loop

Two-phase natural circulation and boiling experiments are conducted in this study with artificial seawater as a heat transfer fluid or process coolant. This experimental work is focused on understanding the role of dissolved salts in water on the steady state two-phase natural circulation flow rates. Mass flow rates were measured at different heat flux levels with artificial seawater, deionized water and tap water in the experimental loop. It was found that the average quasi-steady state mass flow rates were the same at any particular heat flux level regardless of the fluid being used. Artificial seawater coolant exhibited more stable natural circulation at higher heat flux as compared to the other two coolants. Mass flow measurements recorded at 2 s intervals show that magnitude of flow oscillations are much higher in case of tap water and deionized water. Also, high speed camera images revealed that the bubble departure diameters are smaller in seawater compared to tap or deionized water. This can be attributed to the increased local wettability due to the presence of dissolved salts in the fluid. Visual observations of the riser section showed that bubble coalescence and formation of slugs is inhibited in the seawater. These observations also explain the reduced pressure drop across test section when seawater was used as a coolant.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray Imaging-Based Void Fraction Measurement in Saturated Flow Boiling Experiments with Seawater Coolant

Recent studies have shown that the presence of dissolved salts in water can exhibit peculiar flow boiling and two-phase flow regimes. Two-phase flow and convective flow boiling are typically characterized with the help of void fraction measurements. To quantitatively improve our understanding of two-phase flow and boiling phenomenon with seawater coolant, void fraction data are needed, which can not be obtained from optical imaging. In this paper, we present experimental void fraction measurements of saturated flow boiling of tap water and seawater using X-ray radiography. X-rays with a maximum energy level of 40 KeV were used for imaging the exit region of the heated test section. At lower heat flux levels, the two phase flow in seawater was bubbly and homogeneous in nature, resulting in higher void fractions as compared to tap water. With an increase in heat flux, the flow regime was similar to slug flow, and void fraction measurements approached similarity with tap water. The predicted pressure drop using the measured void faction shows good agreement with the measured total pressure drop across the test section, demonstrating the validity of the measurement process.

Eckels, Seth↗

Time-resolved measurement of subchannel void distribution for boiling two-phase flow in 5 x 5 rod bundle at high-pressure and high-temperature

A subchannel void sensor (SCVS) was improved to acquire time-resolve boiling two-phase flow in a 5-by-5 heated rod bundle at high-pressure and high-temperature. The SCVS consists of 6-by-6 wire electrodes and 5-by-5 rod electrodes. The SCVS can acquire a time series data of local void fraction at 32 points of central subchannel region in addition to 100 points of rod surface regions between rods. The devised sensors are installed in the heated rod bundle at eight height levels to acquire two-phase flow dynamics and its development. The axial and radial power profile of the heated rod bundle are uniform, and eight pairs of sheath thermocouples are embedded on the heated rod to monitor its surface temperature distribution. The paper addresses the axial and cross-sectional distributions of void fraction at various pressure and rod bundle power conditions, which simulates an accidental condition in reactor core and in a spent fuel pool of a boiling water reactor (BWR). The experimental data are suitable to validate the computational multi-fluid dynamics (CMFD) and subchannel codes. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development and Validation of a Two-Phase Thermal-Hydraulic CFD Code NEK-2P

A project is underway to develop, verify and validate an advanced two-phase flow modeling capability for the highly-scalable, high-performance Computational Fluid Dynamics (CFD) code NEK5000. The goal of this work is to verify and validate the two-phase version of the NEK5000 code, named NEK-2P, to simulate the two-phase flow and heat transfer phenomena that occur in a Boiling Water Reactor (BWR) fuel bundle under various operating conditions. The NEK-2P two-phase flow models follow the approach used for the Extended Boiling Framework (EBF) previously developed at Argonne but include more fundamental physical models of boiling phenomena and advanced numerical algorithms for improved computational accuracy, robustness, and computational speed. The development of the NEK-2P two-phase solver and the implementation of the Extended Boiling Framework two-phase models were initially supported by Argonne National Laboratory (Argonne) through a Laboratory Directed Research and Development (LDRD) project during FY2014-2016. The development and validation of the two-phase models through analyses of selected two-phase boiling flow experiments was supported by the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program in FY2017-2020. This report focuses on verification and validation of the water-steam boiling model NEK-2P Two-Phase, CFD code. The NEK-2P was validated with Nuclear Power Engineering Corporation (NUPEC) Pressurized Water Reactor (PWR) Sub-channel and Bundle Test (PSBT) void distribution benchmark. Three different simulations were performed and analyzed for various operating conditions such as wall-heat flux and sub-cooled inlet temperatures. Reasonably good agreement with measured data was obtained in predicting the measured void distributions. Simulations were performed for Virginia Tech. (VT) 3x3 rod bundle geometry with and without spacers. The preliminary results were presented for Simplified Spacer Grid (SSG). In addition, the implementation of interface reconstruction model was tested with one of the Becker benchmark Critical Heat Flux (CHF) experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development and Validation of a Conjugate Heat Transfer Model for the Two-Phase CFD Code NEK-2P

A project is underway to develop, verify and validate an advanced two-phase flow modeling capability for the highly-scalable, high-performance CFD code NEK5000. The goal of the project is to develop a new two-phase version of the NEK5000 code, named NEK-2P, to simulate the two-phase flow and heat transfer phenomena that occur in a Boiling Water Reactor (BWR) fuel bundle under various operating conditions. The NEK-2P two-phase flow models follow the approach used for the Extended Boiling Framework (EBF) [2-3] previously developed at Argonne, but include more fundamental physical models of boiling phenomena and advanced numerical algorithms for improved computational accuracy, robustness, and computational speed. The development of the NEK-2P two-phase solver and the implementation of the Extended Boiling Framework two-phase models were initially supported by Argonne National Laboratory (Argonne) through a Laboratory Directed Research and Development (LDRD) project during FY2014-2016. The development and validation of the two-phase models through analyses of selected two-phase boiling flow experiments was supported by the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program in FY2017-2019. This report focuses on the FY2019 development and validation of the Conjugate Heat Transfer (CHT) model for the NEK-2P Two-Phase, Computational Fluid Dynamics (CFD) code. The NEK-2P CHT model calculates the coupled behavior of the fluid and solid domains. In the fluid domain NEK-2P calculates the vapor and liquid phase temperatures, velocities and mass fractions. In the solid domain only the temperatures are calculated. The fluid and solid domains are coupled with a heat flux boundary condition at the fluid-solid interface. The heat flux and the wall temperatures at the fluid-solid interface are updated using the NEK-2P wall heat-flux partitioning model. A wall heat flux boundary condition is also applied to the exterior surface of the solid domain. The CHT model validation was illustrated through the analysis of three of the Becker Critical Heat Flux (CHF) tests. Reasonably good agreement with measured data was obtained in predicting the CHF location and post CHF wall temperature behavior illustrating the ability of the NEK-2P CHT model to simulate the CHF phenomena for a wide range of thermal-hydraulic conditions. Apart from the CHT model development and validation, initial simulations were performed for the Virginia Tech. (VT) 3x3 bare rod bundle experiments including both cold and boiling flow simulations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simulation of Boiling Two-Phase Flow in a Helical Coil Steam Generator Using the Spectral Element Code Nek-2P

To enable the design of a light water small modular reactor, the boiling flow inside a helical coil steam generator has been simulated with the two-fluid model in Nek-2P. Nek-2P is the multiphase branch of the spectral element code Nek5000. Details of the implementation of the two-fluid model and the included closure models are discussed. The presented closure models include interactions for momentum, heat, and mass transfer between phases. Models for the drag, lift, and turbulent dispersion forces are included. The complete model is fully consistent in the limits of both phasic volume fractions approaching zero and is able to simulate flows of dispersed vapor, continuous liquid, dispersed liquid, continuous vapor, or any combination thereof. The closure models and their implementation in Nek-2P have been validated by comparing to experimental data for a boiling flow, demonstrating excellent agreement. Results from the simulation of the helical coil indicate strong phasic separation driven by the effects of buoyancy and inertia. Finally, significant differences were observed in the results compared to simulations performed using Star-CCM+, although these differences were somewhat expected.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation on numerical method of one-dimensional drift flux model for boiling two-phase flow

A numerical method for the solution of one-dimension drift-flux model has been developed. Correlations for heat and mass transfer and kinematic constitutive equation were used to close the set of the partial differential equations. The finite volume method based on the staggered grid and fully implicit backward Euler method were applied to discretize the spatial and time differential items, respectively. The discretization equations were solved iteratively in a same manner as in SIMPLE method for a single-phase flow. The verification and validation of the numerical method and closure model for one-dimension drift-flux model have been performed by comparing the code solution with the experimental data. Furthermore, the axial distribution of void fraction and pressure also have been investigated under different heated case. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

On the prediction of critical heat flux using a physics-informed machine learning-aided framework

The critical heat flux (CHF) corresponding to the departure from nucleate boiling (DNB) crisis is essential to the design and safety of a two-phase flow boiling system. Despite the abundance of predictive tools available to the thermal engineering community, the path for an accurate, robust CHF model remains elusive due to lack of consensus on the DNB triggering mechanism. This work aims to apply a physics-informed machine learning (ML)-aided hybrid framework to achieve superior predictive capabilities. Such a hybrid approach takes advantage of existing understanding in the field of interest (i.e., domain knowledge) and uses ML to capture undiscovered information from the mismatch between the actual and domain knowledge-predicted target. A detailed case study is carried out with an extensive DNB-specific CHF database to demonstrate (1) the improved performance of the hybrid approach as compared to traditional domain knowledge-based models, and (2) the hybrid model’s superior generalization capabilities over standalone ML methods across a wide range of flow conditions. The hybrid framework could also readily extend its applicability domain and complexity on the fly, showing an elevated level of flexibility and robustness. Based on the case study conclusions, the window-type extrapolation mapping methodology is further proposed to better inform high-cost experimental work.

42 ENGINEERING↗

Evaluating the Practicability of Multiphase CFD for BWR Fuel Assembly Analysis

Multiphase computational fluid dynamics (M-CFD) models of a boiling water reactor (BWR) fuel assembly have been generated in the commercial CFD code, STAR-CCM+ Ver.11.04.010-R8. The Eulerian multiphase approach was employed, in combination with a baseline ‘Zero Closure model’ for two-phase flow boiling, applicable to high void fraction regimes. The capability and practicability of MCFD for BWR fuel assembly were evaluated against the international OECD/NRC BWR Full-size Finemesh Bundle Test (BFBT) benchmark data. The benchmark selected, BFBT-4101-61, is a steady-state full power case, with high void fraction conditions. Geometrical modeling and mesh construction of BWR assemblies introduce challenges in generating high quality computational meshes, while retaining a low cell count to allow acceptable runtimes. In order to evaluate the scalability of the CFD code, parallel CFD simulations were carried out with the High Performance Computing (HPC) system of the Idaho National Laboratory. M-CFD results display good agreement with the experimental data for both local void fraction distribution and exit quality. The parallel speedup factor is linearly proportional to the number of processors up to 500 cores, and retains over 92% efficiency with 1000 cores. The execution time of the simulation decreased exponentially with increasing number of processors while the cost of the simulation increased linearly. The proposed baseline closure, in combination with the parallel performance of the STAR-CCM+ code demonstrated promising capabilities for analyzing BWR fuel assemblies.

97 MATHEMATICS AND COMPUTING↗

Enabling BWR fuel rod analysis in the BISON fuel performance code

Nuclear fuel vendors around the world are pursuing approaches to sustain the existing nuclear reactor fleet consisting primarily of pressurized-water reactors (PWRs) and boiling-water reactors (BWRs). To support the industry's efforts, advanced modeling and simulation tools need to be capable of analyzing both legacy reactor concepts. BWR fuel rods are significantly different than those used in PWRs, which can affect fuel performance analysis. BWR fuel rods include: (1) an extensive use of gadolinia dopant as a burnable absorber, (2) an axial variation in fuel enrichment and gadolinia content, (3) the inclusion of a liner on the inner cladding surface to mitigate the impact of pellet-clad mechanical interaction (which impacts hydrogen and hydride distribution), (4) a lower initial fill gas pressure, (5) bottom-entry control rods, and (6) a lower coolant pressure that results in the two-phase flow boiling phenomenon. Although the primary focus of BISON has been in the area of PWR and advanced reactor fuel analyses, this paper presents the developments in BISON to support BWR fuel performance analysis. An overview of the models that account for the effects of gadolinia is highlighted. Internal mesh generation capabilities to include a liner is presented. Normal operating and transient (reactivity insertion accident) demonstration problems are presented to illustrate the impact of gadolinia, the hydrogen and hydride evolution due to the presence of the liner, and BISON's ability to simulate axially varying enrichments and dopant concentration. Bottom-entry control effects are captured by the axial power peaking factors present in the demonstration cases. Comparisons to integral experiments from the Halden IFA-681 experiments are discussed as initial validation. Reasonable comparisons are obtained for fuel centerline temperature and rod internal pressure as a function of time. In conclusion, simulations of additional experiments containing Gd 2 O 3 -bearing fuel are necessary to completely validate the code for BWR applications.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Flow instabilities in helical-coil steam generators for small modular reactors: A review

Here, this study covers the research and discoveries in two-phase flow-boiling instabilities available in the literature—specifically for a helical-coil steam generator (HCSG), including experimental findings, theoretical research, computational models, and system code analyses—supporting research and development of representative small modular reactors (SMRs). Like other new and advanced reactor systems, water-cooled SMRs require experimental data from both integral and separate thermal-hydraulics test facilities for the verification and validation (V&V) of the computational models and computer codes in order to design and obtain regulatory approval. The complex dynamics of two-phase flow-boiling instabilities includes flow regimes physics phenomena, flow-channel geometries, heat-transfer behavior, and interactions among the solid–liquid-gas within the system boundary, all of which are pivotal for understanding the design and operational challenges of SMRs. This study focuses on identifying the relevant knowledge gaps on boiling instabilities—specifically for a HCSG—and provides insights about future research direction optimizing the transport of thermal energy, mass-flow rates, and boundary conditions that ensure the adequate heat-transfer performance, operational stability, and safety associated with SMR systems.

20 FOSSIL-FUELED POWER PLANTS↗

A phase-field method for boiling heat transfer

Here we present a phase field method for heat transfer in two-phase flow with boiling. The vapor/liquid interface evolution is modeled by the Cahn-Hilliard equation. The phase change rate is determined by accounting for the heat conduction balance on either vapor or liquid side of the interfacial area, depending on which side the temperature is assumed to be maintained at the saturation temperature during boiling. The velocity correction scheme proposed by Dong & Shen [27] is extended to solve the Navier-Stokes equations for a non-solenoidal velocity field, and the entropy viscosity method is employed for stabilization. The phase change model is verified by two-dimensional simulations of a vapor bubble growing in super-heated liquid and in film boiling. In both cases, mesh independence of the results is systematically performed. Subsequently, the method is applied to predict the growth of three-dimensional vapor bubble in a rectangular microchannel with boiling flow, achieving good agreement with experimental measurements and available simulation results using the level-set method. The numerical experiments demonstrate that the required mesh resolution for the phase field method is comparable with that of volume of fluid (VoF) and level-set methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Newton-Krylov method in solving drift-flux two-phase flow problems for both pre-CHF and post-CHF conditions at steady state

Furthermore, this paper presents numerical simulations of two-phase flow heat transfer for both pre-CHF and post-CHF conditions typical in light water nuclear reactors. The conjugate heat transfer problem is modeled with one-dimensional drift-flux two-phase flow model for coolant flow and two-dimensional heat conduction equation in solid walls. Fully implicit time integration schemes were employed, and the resulted non-linear equations were solved with a Newton-Krylov method. For the drift-flux two-phase flow model, the EPRI drift-flux closure correlation is used to model the relative motion between the two phases. Additional closure correlations were adopted from REALP5-3D to determine two-phase flow regime, wall boiling heat and mass transfer, interfacial heat and mass transfer, and two-phase flow frictional pressure drop. Three sets of experiments were used for code validation, including Bartolomei subcooled flow boiling in vertical pipes, FRIGG boiling tests in vertical bundles, and Bennett heated tube tests. RELAP5-3D simulation results were also provided to perform code-to-code benchmark. Overall, numerical results of this work showed good agreements with both experimental data and RELAP5-3D simulation results. Discrepancy between them were also identified in post-CHF region, which suggests necessary further improvement.

42 ENGINEERING↗

Study of the film boiling heat transfer and two-phase flow interface behavior using image processing

Here, in this study, based on a small-scale quench test facility, the two-phase flow interface behavior during quench transients is visualized and analyzed utilizing an image processing framework. The high-fidelity experimental results obtained for two-phase flow in the current framework can support various studies both in the time domain and in the frequency domain. In particular, visualization of the data obtained from different heating surfaces under different test conditions are used to perform a full-scale transient 2-D vapor film reconstruction. The liquid-vapor interface variations in various heat transfer regimes as well as at the initial film breakup point can be directly obtained through the processed data. Moreover, the temporal variation of the interfacial wave frequency approaching quench is investigated in detail. Based on the high-resolution data obtained for the liquid-vapor interface, the detailed phase velocity and temperature profiles are obtained through theoretic analysis, based on which the film boiling heat transfer coefficient (HTC) can be determined. In addition, an improved film boiling HTC model is developed considering the effects of wall superheat, liquid subcooling temperature, vapor film thickness as well as fluid properties. The model is found to predict film boiling HTC well within 15% error.

42 ENGINEERING↗