Search NASA⌕ Search

SEARCH · Search NASA

Results for “two-phase building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler Using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application: Preprint

Previously, two-phase capillary-based cooling from narrow (200-1,000 micrometer) heater-bridge copper inverse opal (CIO) wicks with heat flux levels exceeding 1,400 watts per square cm with a low superheat of approximately 10 degrees C was demonstrated. Here, we demonstrate the area scaling of the proposed technology to large-area micro-cooler for the high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary wicking in 25-micrometer-thick CIOs with an open channel silicon 3D-manifold for liquid delivery and vapor extraction, to achieve a high heat flux of approximately 400 watts per square cm over a heated area of 1 square cm. For the range of inlet water (21 degrees C water temperature) flowrates from 5 to 60 mL per min, we achieved total thermal resistances and vapor qualities of 0.68-0.2 square cm Kelvin per watt and 0.55-0.12, respectively. The high heat flux levels are achieved with flowrates that are 10 times smaller than conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances are in the range of 0.05 to 0.02 square cm Kelvin per watt with temperature superheat of 8 to 6 degrees C. While the overall performance of the large-area (10 by 10 square millimeter) capillary-based micro-cooler degraded compared to previous demonstration of the technology for a heated area of 5 by 5 square millimeter, preliminary computational fluid dynamics (CFD) modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

Enhancement of phase change material hysteresis model: A case study of modeling building envelope in EnergyPlus

Nowadays, buildings are expected to offer demand side services to the power grid to enhance the electrical load flexibility, which leads to the concepts of grid-interactive efficient buildings (GEBs). Phase change material (PCM)-based thermal energy storage has seen increasing attention in recent years for peak load shifting of grid-interactive efficient buildings (GEBs). Numerical models are critical tools for design and evaluation of PCM-integrated systems. Most industrial-grade PCMs are reported to melt/freeze over a temperature range instead of at a unique temperature. Such thermal hysteresis effect significantly affects the reliability of simulation results because not only the heat transfer process depends on melting and freezing temperatures, the PCM thermal properties change significantly during the phase change process as well. This study is aimed to develop a model for the PCMs used in the building envelope with the capability to accurately simulate hysteretic behaviors. Further, this model is based on a two-phase assumption and is implemented in a whole building energy performance simulation program (i.e., EnergyPlus). A comparison between numerical results and experimental data shows that during a complete phase transition, the two-phase model could achieve a good agreement with the experimental data. During a partial phase transition, the two-phase model could lead to significant improvements compared to other alternative PCM models, including the existing PCM model in EnergyPlus. Last, whole building simulations were performed to study this model's performance regarding heating/cooling loads and zone mean air temperature of a given building. The results show that the difference in hourly heating/cooling loads introduced by the models was less than 1% in design conditions, while significant changes were observed in both hourly heating/cooling loads and zone mean air temperature when the PCM envelope underwent partial phase transition processes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EXPERIMENTAL AND MODELLING ANALYSIS OF A LARGE-SCALE TWO-PHASE LOOP THERMOSYPHON

Liquid pumping requires large quantities of electrical energy, including about 7% of the energy of building heating, ventilation, and air conditioning (HVAC) systems. To replace pumped condenser-cooling tower water loops with a passive alternative system, we implemented a commercial-scale two-phase loop thermosyphon (TPLT). The unit consists of a 13 m riser integrated with a commercially available cooling tower and circulation water heater that simulates heat loads up to 25 kW. In addition to providing passive cooling capabilities, the cooling tower unit is also maintenance free, reliable, and can operate in both dry and wet modes. This study characterizes the performance (temperature difference between the evaporator and condenser) and the two-phase flow behavior of the loop under various refrigerant charges. Sight glasses installed throughout the loop are used to identify the operating flow regimes in the riser and downcomer. Over the range of operating conditions, we identified that there is an optimal refrigerant charge range for a specific heat load at which near-isothermal operation can be achieved. We further developed a model to predict the operating flow rate and gravitational height in the downcomer and compared it with the experimental data. The results show that the model agrees with the experimental data, in particular the threshold gravitational head height at which there will be subcooled liquid at the condenser exit, indicating that it can be used as a predictive tool for identifying the optimal loop charge for a given heat load.

Loop thermosyphon, passive two phase↗

Switchgrass ( Panicum Virgatum ) and Miscanthus ( Miscanthus × Giganteus ) Long-Term Yield Patterns Reveal Consistent Productivity Declines

Perennial grasses like switchgrass ( Panicum virgatum ) and miscanthus ( Miscanthus × giganteus ) are expected to supply a substantial amount of the United States bioeconomy's feedstock demand. However, uncertainties around their long-term yields challenge the viability of their potential and limit their wider adoption. To resolve their long-term yield patterns, we analyzed over 200 plantings of switchgrass and miscanthus across Michigan and Wisconsin, USA, measured over 5–15 years. We found a consistent two-phase long-term yield dynamic; during a yield-building phase , peak yields occurred within 4–5 years after planting, followed by a yield-decline phase in which switchgrass and miscanthus lost 30%–47% and 14%–40% of peak yields, respectively. Among the potential drivers of this dynamic and the yield decline, we found that weather conditions had little impact, as the variation across years was not large enough to drive the observed yield differences. Added nitrogen increased peak yields by 10%–20% and attenuated the yield decline by 20%–50%. However, since fertilized stands still showed a yield decline, other factors became limiting as stands aged. This conserved long-term yield dynamic has direct implications on management. A farm-to-gate economic analysis suggests replanting switchgrass and miscanthus 5 and 9 years following their peak yields maximizes profit over a 30-year time horizon. Results call for further management and breeding strategies to mitigate the yield-decline phase, and for reparameterization of global bioenergy models with carbon capture and storage, which may overestimate yields and the economic and environmental benefits of crops grown for bioenergy feedstocks.

bioenergy↗

Alchemy: A Model-Based Approach for 2D to 3D Autonomous Nuclear System Design

Engineering design of nuclear power plant (NPP) piping and equipment systems frequently bypasses crucial 2D system planning, instead moving straight to 3D modeling. This often leads to designs that exceed building envelope constraints, forcing expensive and time-consuming redesigns. When 2D modeling is employed, it typically involves labor-intensive manual workflows that convert 2D drawings into 3D models, resulting in inefficiencies and errors across design iterations. These workflows further suffer from poor software interoperability and dependence on proprietary software ecosystems, thereby contributing to schedule delays and cost overruns. This paper presents Alchemy, an autonomous framework that transforms 2D system definitions into Industry Foundation Classes (IFC)-compliant 3D building information models (BIMs) for expediting nuclear facility design at the conceptual preliminary phase. Using a model-based approach, the framework treats the 2D system diagram as the central reference model employed to automatically generate all subsequent outputs, ensuring consistency between the system definition and the resulting physical design. A web-based interface enables engineers to define hierarchical system topologies including associated equipment, geometric properties, and connectivity requirements. A two-phase equipment layout optimization algorithm automatically computes collision-free spatial configurations within predefined building envelopes. An artificial intelligence (AI)-assisted pipe routing module then generates orthogonal, collision-free routing paths, allowing the user to select either an A* search-based method or an Ant Colony Optimization (ACO)-based method. All outputs are authored natively in IFC format, relying on open-source technologies and standardized formats in order to ensure extensibility and eliminate proprietary software dependencies. The proposed framework is validated on two representative pressurized-water reactor (PWR)-based case studies, for which it autonomously generates IFC-compliant 3D models in minutes, drastically reducing workflows that typically require hours of manual effort. The generated model demonstrates topologically correct equipment placement, physically plausible spatial relationships, and collision-free pipe routing consistent with known PWR loop configurations. This work represents a foundational step toward digital engineering for nuclear facility preliminary design, with future ongoing development targeting design code compliance and expanded system complexity.

97 - MATHEMATICS AND COMPUTING↗

SolarAPP+ Pilot Analysis: Performance and Impact of Instant, Online Solar Permitting

The National Renewable Energy Laboratory (NREL) led a collaborative effort to develop the Solar Automated Permit Processing Plus (SolarAPP+), a no-cost solar permitting software solution to address residential solar photovoltaic (PV) permitting resource constraints and streamline solar adoption processes among authorities having jurisdiction (AHJs). The SolarAPP+ is an online portal that automates permit plan review, enabling an instant permit approval process for code-compliant residential PV systems. Based on national model building, electrical, and fire codes, the SolarAPP+ automatically performs a compliance check of permit inputs against code requirements and produces an inspection checklist that can be used to verify installation practices, workmanship, and adherence to the approved design. NREL conducted a two-phase pilot with five participating AHJs and 16 solar contractors, spanning from November 2020 through December 2021, evaluating the ability of SolarAPP+ to deliver instant permits and its impact on four critical areas within each AHJ: permit review timelines; solar adoption timelines; AHJ time saved; and inspection results. The pilot confirmed that SolarAPP+ reduced permit review times to less than one day, reduced solar adoption timelines by an average of 12 days, saved an estimated 2,067 staff hours, and had comparable inspection results to those found in traditional permitting. The pilot further identified key lessons for improving SolarAPP+, including ways to streamline SolarAPP+ adoption, development of training resources, and expansion of supported products.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Population Balance Models for Catalytic Depolymerization: From Elementary Steps to Multiphase Reactors

Here, the ongoing accumulation of plastic waste in landfills and in the environment is driving research on chemical processes and catalysts to recycle polymers. Traditional modeling strategies are not applicable to these processes because they involve too many reactants and intermediates, one for each molecular weight and each functionalization. To model the kinetics, we have developed population balance models (PBMs) that account for macromolecular reactants in the bulk and macromolecular catalytic intermediates. These PBMs couple to each other through polymer adsorption and desorption models and to traditional rate equations for small molecule products and co-reactants (like hydrogen or ethylene). The models, in combination with experimental data, are being used in many ways: (i) to test mechanistic hypotheses, (ii) to extract rate parameters, (iii) to quantitatively compare catalyst activities, (iv) to account for mass transfer and vapor–liquid partitioning in two-phase reactors, and (v) to design novel support architectures and catalysts that mimic the processive action of natural depolymerization enzymes. Some key theoretical advances allow PBMs to be constructed from elementary rates and mechanisms, as opposed to traditional formulations with pseudoelementary rate parameters invoked as fitting parameters. We discuss ways to build these models “bottom-up” from first-principles calculations and ways to extract model parameters from “top down” analyses of rate data. The combination provides a quantitative bridge between first-principles calculations and the kinetics of complex macromolecular transformations for polymer upcycling and beyond.

Manis, Lela K. [University of Illinois at Urbana-C↗

Asymptotic hydrogen redistribution analysis in yttrium-hydride-moderated heat-pipe-cooled microreactors using DireWolf

Yttrium hydride (YH x ) is one of the materials being considered for moderating thermal and epithermal nuclear microreactors. One potential issue with YH x use is that the hydrogen redistributes in the hydride when thermal and concentration gradients are present. This hydrogen redistribution leads to spatial gradients in the hydrogen concentration, thus affecting neutron transport in the reactor. Here, by building upon observations in prior works, this paper aims to gain a better understanding of the reactivity feedback associated with such hydrogen redistributions. In particular, we wish to understand the sign (+/–) of the hydrogen redistribution neutronic feedback, its order of magnitude, and its underlying physical causes. To achieve this goal, the DireWolf multiphysics software driver was used to solve the coupled radiation transport, heat transfer, heat pipe two-phase flow, and hydrogen redistribution equations for the Simplified Microreactor Benchmark Assessment (SiMBA) problem, a full-core microreactor numerical benchmark developed at Idaho National Laboratory.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Myna: Connecting powder bed fusion build data to simulation tools for digital twin applications

Additive manufacturing (AM), as a digital process, can generate a detailed digital thread linking a part’s design and manufacturing to its operational performance. As AM systems advance, an increasing amount of process data is stored in manufacturing databases. In principle, this data can be utilized by simulation-based digital twin approaches, such as real-time process control and asynchronous post-processing guidance. However, few tools currently exist for systematically integrating digital thread data with computational tools. Here, in this study, we propose a software package, called Myna, for connecting data from powder bed fusion processes to simulation tools. The utility of such a platform is demonstrated using build data from the Oak Ridge National Laboratory Manufacturing Demonstration Facility “Peregrine v2023-10” public dataset to automatically configure and run 54 semi-analytical 3DThesis melt pool simulations, 78 numerical Additive FOAM melt pool simulations, and 3 ExaCA microstructure simulations. The simulated, spatially registered microstructures are then compared directly with electron backscatter diffraction characterization of the corresponding as-built part locations. The resulting simulated microstructure showed variation as a function of process parameters, particularly stripe width; however, the experimental data had little variation between the microstructure texture and grain size resulting from different processing conditions. Analysis of the discrepancies suggest that it is possible a two-phase ferritic-austenitic solidification model is needed to accurately predict grain size and texture for certain stainless steel 316L feedstock compositions under powder bed fusion conditions, providing direction for future research. As illustrated here, due to the number and complexity of the simulations involved in AM process-structure–property predictions, automated methods to connect process data and simulations will remain necessary tools for testing hypotheses and implementing digital twin applications.

Knapp, Gerald L. [Oak Ridge National Laboratory (O↗

A renewable lignin-based thermoplastic adhesive for steel joining

Adhesive bonding of metals has become increasingly relevant in recent years due to the demand for reducing weight and improving performance in structural applications such as automobiles and aerospace. We developed renewable thermoplastic adhesives from technical organosolv lignin isolated from hardwood biomass and acrylonitrile butadiene co-polymer rubber (NBR) for joining steel substrates. NBR33, NBR41 and NBR51 with acrylonitrile molar ratios of 33, 41 and 51%, respectively, were blended with lignin to form two-phase thermoplastic adhesives, and their adhesion, viscoelastic and surface properties were measured. Lignin content in the compositions were varied, ranging from 40% to 80% (w/w), to alter toughness, stiffness, and surface energy characteristics of the material. Better interaction or reactivity between the lignin and NBR phases was observed with greater nitrile content in NBR, leading to greater modulus and stiffness of the adhesive. Simultaneously, increasing the proportion of lignin reduced toughness and improved stiffness, with the highest adhesive strength of 13.1 MPa measured in a 60% lignin loading ratio with NBR51. Surface energy measurements revealed that total surface energy (sum of polar and dispersive surface energy) raised with lignin loading, suggesting that both surface energy and matrix strength play a critical role in the adhesive properties of the synthesized materials. A finite element-based cohesive zone model (CZM) was developed and implemented to study the failure strength of the adhesively bonded joint. Here, this study demonstrates the viability of lignin as a valuable building block for adhesives, not only due to its inherent chemical structure and rigidity, but also for its surface energy characteristics.

36 MATERIALS SCIENCE↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Constraining the release of Sn to the ambient melting point following shock loading using time-resolved x-ray diffraction

The formation of liquid following release from a shocked state governs the transition from spall to cavitation and the formation of ejecta in metals. In order to build physics-based models of these processes, it is necessary to critically evaluate the relative importance of kinetics and entropy generation during the release along with the accuracy of multiphase equations of state. Tin (Sn) has served as a testbed for a variety of experiments examining strength and ejecta due to its accessible melt boundary and solid–solid phase transitions. This work presents experiments examining the phase evolution of high purity Sn following the shock and release to ambient stress near the melting point. Sn is found to release to states between its ambient solidus and liquidus from approximately 19 to 33 GPa under uniaxial loading, with the two-phase region being characterized by a reduction in the intensity of the (220), (211) β -Sn doublet. Jetting experiments performed at 27–28 GPa exhibit comparable diffraction patterns with what is observed following the uniaxial release. The solid fractions of β-Sn in the ambient mixed phase region are found to decrease linearly with increasing shock stress as increasing liquid Sn is formed. Here, the results provide much needed information for interpreting measurements of dynamic strength at a high strain rate and experiments examining cavitation and shallow bubble collapse in Sn.

, spall↗

Simulation of Particulate Transport for Delivery of Solid Amendments into the Subsurface: FY24 Status Report

For particulate-based amendments to be viable for field-scale remediation at the Hanford Site (e.g., 200 DV-1 Operable Unit), particles need to be delivered a sufficient radial distance from an injection well and retained at concentrations high enough for effective treatment. An accurate description of the particle radius of influence (ROI) is critical for developing an overall remediation strategy. However, field-scale particle simulations are currently limited due to insufficient simulation capabilities and a lack of experimental data to validate and parameterize particle transport models. To help build toward field-scale deployment, this fiscal year (FY) we have (1) developed a pre screening tool to estimate particle transport, (2) implemented particle transport models within PFLOTRAN, and (3) conducted preliminary estimations of particle ROI. While field-scale numerical simulations will ultimately be necessary before remedy design and field implementation, we have developed a pre-screening tool that offers valuable estimations of expected particle injectability and ROI in a 1-D system. The advantage of the tool is that it does not require extensive laboratory experiments and instead makes predictions based solely on routine laboratory measurements. This tool can assist in down-selection and decision-making by identifying which particle amendment systems are worth pursuing in future laboratory experiments, such as 1-D column tests and beyond. With any system, scaling up from the lab to the field presents challenges. Currently, there is no field data available for model calibration or validation. However, the theoretical particle models being developed herein are the best tools available to guide progress toward field deployment. To help bridge this gap and verify model predictions, larger-scale lab experiments are being proposed. To advance simulation capabilities, six particle transport models are being integrated into the reactive transport simulator PFLOTRAN. These include colloid filtration theory (CFT) and five additional particle transport models (M1-M5). Each model, from M1 to M5, progressively incorporates additional particle transport and retention processes. Ultimately, the simplest model capable of accurately describing 1-D column data will be selected and parameterized. During FY24, the CFT and M1 model have been fully implemented within PFLOTRAN. Using an existing 1 D column experiment, the two currently implemented particle transport models (CFT and M1), and associated parameters, were fit to this experiment. While simpler model formulations are helpful for estimations, these formulations could not fully describe particle transport and retention behavior in the previous 1-D column experiment. Thus, additional complexities will need to be considered, which will be accounted for in the M2-M5 model formulations. Additionally, because a viscous, shear thinning fluid was required to keep particles in suspension, considerations for flow will also need to also be accounted for. Therefore, a new immiscible two-phase flow mode is currently being implemented in PFLOTRAN. With some modifications, this new flow module could also support simulation of non-Newtonian liquid amendments, foams, and emulsions. We also estimated the expected ROI of solid amendments using 1-D simulations. The average predicted ROI was approximately 15 ft for micron-sized zero valent iron (mZVI) suspended in xanthan gum (XG). Using the pre screening tool and ROI estimates, additional amendment-delivery laboratory characterization and experiments are proposed. The results from additional experiments can be used to validate and parametrize particulate transport model formulations, which will ultimately provide predictive capabilities for field amendment-delivery systems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimentation on Finned-Tube Microchannel Heat Exchanger Incorporating Phase Change Material and R-410A

Integrating latent heat thermal energy storage, particularly phase change materials (PCM), in building heating, ventilation, air conditioning, and refrigeration (HVAC&R) systems, offers substantial benefits for peak load shifting and energy efficiency. While numerous studies explore PCM-embedded heat exchangers (PCM-HX) using single-phase heat transfer fluids, there needs to be more investigation regarding PCM-HX utilizing two-phase refrigerant flow. This gap is even more pronounced for microchannel heat exchanger (MCHX) configurations. In this study, an MCHX-based PCM-HX was built and tested to analyze and evaluate the performance of a PCM-HX operating with a two-phase refrigerant as the working fluid. A commercially available MCHX condenser unit was embedded with 2.6 kg of RT35 PCM and tested using R-410A as the working fluid, using an in-house test loop to control the refrigerant inlet conditions precisely. Thin and minimally invasive T-type thermocouples traced the temperature evolution along MCHX channels and tube banks. Additional larger T-type thermocouple probes at the refrigerant inlet and outlet measured the average power of the PCM-HX during condensing tests, ranging from 0.7 kW to 1.6 kW based on mass flow rates varying from 3.5 g/s to 8 g/s. This experimental study on MCHX-based PCM-HX with a two-phase refrigerant has the potential to offer practical design guidelines for the direct integration of PCM-TES in HVAC&R systems without the use of a secondary loop, while caution is advised to avoid a substantial increase in the refrigerant charge amount.

42 ENGINEERING↗