Search NASA⌕ Search

SEARCH · Search NASA

Results for “two-phase models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Boundary Element Model for Assessing Large‐Scale Pressurization in Faulted Geological Storage Systems

Assessing large-scale pressurization at the regional scale—a possible outcome of large subsurface storage applications such as wastewater injection and geological carbon sequestration—presents significant computational challenges. These challenges are particularly pronounced when accounting for complex geologic structures with multiple reservoir and caprock layers, fault zones, and wells. This study introduces a computationally efficient model that integrates single-phase semi-analytical solutions with a boundary element (BE) approach. The model simulates pressure propagation in multilayered 3D systems, including vertical faults, caprock, basement, and confining units. We apply this new model to a representative scenario involving CO 2 injection near a partially sealing fault with verification against an independent two-phase flow model. Results demonstrate that our model accurately captures far-field pressure responses and that, outside the CO 2 plume zone, pressure predictions from single-phase and two-phase models are nearly identical. This supports the use of single-phase models like ours for efficient estimation of far-field pressure changes. Additionally, we demonstrate its effectiveness at a large scale, incorporating multiple wells and faults. With its ability to represent multiple wells, fault zones, and geological heterogeneity, our model is well suited for assessments of basin-scale pressurization. Its computational efficiency also makes it a promising tool for integration with optimization frameworks aimed at designing and managing injection strategies in faulted storage systems.

Cihan, A. [Lawrence Berkeley National Laboratory (↗

Prototype Modeling for a Light-Trapping Planar-Cavity Enclosed Particle Solar Receiver

Concentrating solar thermal (CST) systems present a promising avenue for affordable and reliable energy production. Solar receivers are key components that determine the efficiency and longevity of these systems. Particle-based solar receivers have emerged as a compelling alternative to traditional technologies, offering several advantages that address limitations in current CST systems. This is especially true as next-generation CST technologies target applications including electricity generation, thermochemical processes, and industrial process heat, many of which necessitate higher operating temperatures than current commercial molten salt systems. Molten-salt thermal energy storage (TES) systems, commonly used in CSP, face challenges related to freezing and corrosion. Particle-based TES systems, in contrast, do not experience these issues, as particles are stable at high temperatures, exceeding 1000 degrees Celsius. This capability allows for a wider range of applications, including those requiring higher temperatures for industrial processes and efficient electricity generation. A novel innovation in particle-based solar receiver technology is the light-trapping planar cavity receiver (LTPCR) configuration developed by NREL. The LTPCR design consists of small cavity-like structures using opaque planar surfaces, enabling efficient capture and absorption of solar energy. A high incident flux concentration at the cavity aperture is absorbed on the receiver walls, and subsequently transferred to particles on the inside of cavities. The particles flow through the system, forming a fluidized bed inside of the receiver panels, effectively capturing the absorbed solar heat. Air is used as a fluidizing medium in this process to enhance particle heat transfer and mixing. The effectiveness of this design lies in its ability to manage solar flux conditions and ensure high solar-to-thermal receiver efficiency. A 100-kW prototype is currently being tested at the King Saud University in Saudi Arabia to assess the receiver performance. A range of modeling analyses for the optical, thermal, and mechanical effects were conducted to assess the performance of the receiver under on-sun conditions. The solar flux resulting from the KSU heliostat field was modeled using NREL SolTrace software and produced up to 600 kW/m2 at the receiver aperture. The solar flux absorbed on the receiver walls was then used within a computational fluid dynamics (CFD) model to predict wall temperature distributions along with radiation and convection loss. A two-phase CFD model was developed for the fluidized bed of silica sand inside the receiver panels to predict local wall-to-particle heat transfer coefficients, particle temperature distributions, and outlet temperature of the particles. We have also conducted analyses to understand the thermomechanical behavior of these innovative enclosed light-trapping solar receivers optimized for particle heating. We used finite element analysis (FEA) to predict the receiver's performance using temperature distributions obtained from CFD and based on the resulting stress profiles, evaluated creep-fatigue damage with a goal of achieving a 30-year service life. Analysis showed a significant impact of the particle-to-wall heat transfer coefficients (HTCs) on receiver performance, with higher HTCs resulting in reduced stress and increased lifespan. For instance, when using Inconel 740H, increasing the HTC from 800 W/m2 K to 1400 W/m2 K increased the creep life from 4,000 hours to over 100,000 hours. This highlights the importance of understanding and optimizing heat transfer in the design of high-efficiency receivers.

14 SOLAR ENERGY↗

Extension of Clad Damage Propagation Model for Fission Gas Dispersal and Two-Phase Flow Effects in MOOSE SubChannel Module

This report presents an extension of the Clad Damage Propagation (CDAP) model implemented in the MOOSE SubChannel Module (SCM) to capture post-failure fission-gas dispersal and two-phase flow effects in sodium-cooled fast reactor assemblies. The extended model tracks discharged gas axially and radially, computes channel-averaged flow quality and void fraction using a Lockhart–Martinelli framework, evaluates two-phase frictional pressure-drop multipliers, determines inlet mass-flow degradation under fixed core pressures, and applies an intensified-void-based heat-transfer degradation to affected fuel pins. Radial plume expansion is parameterized using mineral-oil jet experiments mapped to sodium conditions via Reynolds–Weber similarity. Implementation details are documented, along with the new methods and user inputs needed to control plume mapping and two-phase behavior. Demonstration simulations for 19- and 37-pin bundles show that breach size and inlet velocity strongly influence propagation potential: small breaches (≤0.5 mm) produce limited degradation while larger breaches (~1 mm) can drive oscillatory temperature spikes and enhanced failure propagation, especially at higher velocities. These results demonstrate that the extended CDAP model provides a more complete framework for quantifying cladding damage propagation and evaluating propagation potential in transient scenarios. The approach remains computationally efficient, consistent with subchannel-level analysis, yet incorporates sufficient physics to bridge localized post-failure effects with bundle- and assembly-scale degradation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Kinetic Model of the Long-Term Corrosion of Glass-Ceramic Materials

Multiphase waste forms show promise for increased waste loading and for the ability to dispose of contaminated solid and particulate waste through direct densification. However, achieving predictive capability for long-term durability of multiphase waste forms, and thus assessing their possible deployment, requires expanding the current, limited knowledge base. Here, we describe the development of a corrosion model of a two-phase waste form consisting of crystals of known volume fraction embedded in a glass matrix. This model accounts for the dissolution of both the crystalline and glass phases as well as the hydration of the glass phase through an ion exchange reaction. Because of the large difference in solubility between the two phases, the reactive surface of the crystalline phase is a function of the extent of dissolution of the glass phase in this model. Model parameterization was performed using corrosion data, such as from single-pass flow-through tests, for the individual phases. The parameterized corrosion model was evaluated against static dissolution test data for a glass-ceramic multiphase waste form. This evaluation demonstrated the model’s ability to reproduce the time-dependent release of key tracers of glass and crystalline phase dissolution. Hence, the development of a kinetic model provides a pathway for long-term durability predictions and thus the use of multiphase waste forms in nuclear cleanup missions.

Kerisit, Sebastien N.↗

Asymmetric pathways for lithium extraction and recovery based on the two-phase equilibrium of layered oxides

Electrochemical intercalation offers a promising platform for Li + extraction. However, only limited types of electrode materials have been investigated. The challenge to broaden and tailor materials for electrochemical intercalation-based Li + extraction lies in the lack of understanding of material’s response upon co-intercalation of multiple ions, therefore, paired process design to enable reversible Li + extraction and recovery. Here, we showcase the design of asymmetric ion pathways for Li + extraction and recovery for host material with complex Li + and Na + interaction using layered cobalt oxide as a model material. The two-phase equilibrium of Na 0.48 CoO 2 and Li 0.94 CoO 2 governs Li + selectivity when a high depth of intercalation is achieved (low vacancy level). We show that the relative rate between ion exchange and intercalation is critical to determine the ion pathways. The relationship can be quantitatively compared using the average pseudo ion exchange rate (C pseudoIX ) and the intercalation rate (C inter ). The ion pathways at the three regimes with C pseudoIX > C inter , C pseudoIX ~ C inter , and C pseudoIX < C inter are constructed. By selecting the optimized ion pathway and particle size, we demonstrate 9.7×10 4 Li + selectivity with 99% purity Li + recovery from an initial 1:1000 Li: Na molar ratio solution using 115 mAh/g specific capacity.

electrochemistry↗

Flow pattern and void fraction characterization in nitrogen/water flows through a diamond-type triply periodic minimal surface lattice

Here, this study presents, to the authors knowledge, the first experimental investigation on the void fraction and flow patterns in two-phase flows through a diamond-type Triply Periodic Minimal Surface (TPMS) lattice. An additively manufactured TPMS structure was tested under upward co-current flow of a water/nitrogen mixture. Superficial velocities varied for a total of 42 test conditions (gas: 0.01–2.4 m/s; liquid: 0.01–2.4 m/s; mass flux: 20–2370 kg/m 2 ·s). High-speed video and X-ray imaging enabled time-averaged void fraction measurements and identified six distinct flow regimes which were used to develop a flow pattern map. Comparison of the void fraction data with correlations from literature demonstrated the Rouhani and Axelsson (1970) [49] correlation modified by Steiner (1993) [52] provided the best agreement, which was improved with empirically fit coefficients. This approach predicted the void fraction with errors < ±20% for 64% of the data, with a mean absolute percent deviation (MAPD) of 23%. The measured frictional pressure drop was compared to correlations from literature which captured the observed trends but did not provide good accuracy. The best agreement was found after optimizing the empirical coefficients of the Muller-Steinhagen & Heck (1986) [56] correlation; this approach captured 33% of the data within ±20% with a MAPD of 46% over the full range and captured 71% of the data within ±20% a MAPD of 13.3% at mass fluxes >1100 kg/m 2 -s. These results provide foundational insight into TPMS two-phase flow behavior and inform modeling and design of advanced heat exchange components incorporating TPMS geometries.

42 - ENGINEERING↗

Denudation, solute export, landscape evolution modeling, and geographic information system data for the East River watershed, Colorado, USA (2020-2024)

This data package contains geographic information system (GIS) layers and tabular datasets associated with the study of lithologic controls on denudation, solute export, carbon-scaling relationships, and transient landscape evolution in the East River watershed near Crested Butte, Colorado, USA. The package includes GIS layers used to produce the Figure 2 map, including drainage, hillshade, lithology, sample locations, and basin polygons, together with comma-separated value (CSV) tables and matching CSV data dictionaries. One group of tables reports sample-level and catchment-level information for river-sediment samples analyzed for in situ-produced cosmogenic beryllium-10 (10Be), including sample names, outlet elevations, geographic coordinates, upstream drainage area, rock-type classes, production-rate scaling scheme, analyzed nuclide, catchment-averaged denudation rates, and associated lower and upper analytical uncertainties. Sample and catchment attributes provide the basis for comparing denudation rates across intrusive, shale, sedimentary, and mixed-lithology settings. A second group of tables reports supporting information for landscape-evolution modeling and the mapped geologic framework of the study area. Included files list parameter values and definitions for the two-phase landscape-evolution simulations, summarize full-domain model erosion fluxes and topographic metrics for different simulation configurations, provide a fixed-area carbon-model scaling table, and summarize mapped geologic units within the East River study domain, including geologic code, formation name, lithologic description, mapped area, and lithologic class grouping. Model outputs and geologic summaries support interpretation of transient landscape behavior and its relation to the mapped distribution of shale, intrusive, sedimentary, and surficial units. A third group of tables reports hydrologic and hydrochemical information used to quantify dissolved export from the watershed. Included files provide site-level values for drainage area, mean annual solute export, standard error of annual export, area-normalized solute yield, and equivalent weathering rate for five East River monitoring sites, along with metadata describing the number, sampling cadence, and date range of discharge records and partial and full total dissolved solids observations used in the solute-yield analyses. The package also contains a supplementary daily ion-load time series with daily mean discharge, discharge observation counts, dissolved concentrations, and daily loads for calcium, magnesium, sodium, potassium, chloride, sulfate, nitrate, fluoride, dissolved silica, charge-balance bicarbonate, and total dissolved solids. The package contains GIS files, comma-separated value files (.csv), CSV data dictionaries, a file-level metadata table, a package-tree text file, and a readme text file.

10Be↗

Hydrodynamic Modelling for Tidal Energy Kites: Cooperative Research and Development Final Report, CRADA Number CRD-24-30123

The primary goal of the work is to improve accuracy of hydrodynamic loads acting on the lifting surface of the kite turbine due to complex air-water-lifting body interaction in a low-order numerical model using high-fidelity numerical input. The result of this study will help the Participant better design control algorithms for the kite turbine so that the turbine can harvest more energy while maintaining stability of the platform as well as its reliability. The use of hydrodynamic coefficients/load components from computational fluid dynamic simulation will inform better inputs for a medium-fidelity dynamic model (specifically an OrcaFlex model) which is intended for use in rapid design iterations in the design process.

16 TIDAL AND WAVE POWER↗

Two-Phase Cooling for High Packaging Density Planar Inverter: Cooperative Research and Development Final Report, CRADA Number CRD-15-00592

The project objective was to utilize two-phase heat transfer to enable compact and power-dense inverters. The high heat transfer capacity and near isothermal characteristics of two-phase cooling can enable higher power densities, reducing the size and cost of the power electronics system. This project focused on developing efficient, passive (no pump or compressor) two-phase cooling strategies that consist of an air-cooled condenser and evaporator. This report describes the modeling work conducted to design the evaporator and air-cooled condenser for a prototype inverter development work underway in the John Deere. Prototypes of the final evaporator and condenser designs were then fabricated via 3D printing for testing. Experiments on the evaporator confirmed that this component can meet the heat load and junction temperatures requirements for Si IGBT (insulated-gate bipolar transistor) inverter. Experiments with the air-cooled condenser were not possible due to leaks through the condenser walls.

33 ADVANCED PROPULSION SYSTEMS↗

Two-phase flow numerical analysis of electrode geometry for alkaline water electrolyzers

Hydrogen is a promising component of a future energy-secure and efficient economy, but its competitiveness depends on reducing production costs. One strategy is to operate alkaline water electrolyzers at higher current densities to increase output. However, this intensifies performance losses due to gas bubble accumulation, which blocks transport pathways and deactivates electrochemically active surfaces. Enhancing bubble evacuation through electrode design is therefore essential. Previous studies have explored various approaches — such as modifying surface morphology, applying sonication or pressure modulation, and introducing surfactants — but these efforts have addressed a limited range of conditions due to the complexity of two-phase flow and electrode geometries. Experiments have also largely been focused on either cell level improvements, which lack the information necessary to isolate each contributing factor, or on modified geometries that are not relevant to practical cell operation. From a modeling perspective, conventional Eulerian multiphase models do not track the complex gas–liquid interfacial dynamics and often neglect surface tension and contact angle effects, reducing their predictive accuracy. To provide insights on the effects of different electrode geometries on the performance of alklaine water electrolyzers this work employs an immersed boundary volume-of-fluid method to simulate bubble behavior in 3D porous electrodes. Multiple base electrode geometries, typically used in practice, with varying porosity are evaluated under a constant surface gas generation rate. Simulation data is analyzed to quantify electrode gas coverage, bubble size dynamics and other relevant metrics. Results show that porosity strongly influences bubble accumulation on electrode surfaces, with higher porosity reducing gas coverage, and its not strictly dependent on the electrode geometry. However, the electrode’s base geometry significantly affects gas accumulation at the separator gap, independent of porosity. A foam electrode geometry resulted in the lowest gas coverage of all electrodes with a median volumetric gas coverage of 11%, but at the cost of a 70% reduction in active area compared with the largest surface area electrode, while gyroid electrodes showed the best trade-off between gas coverage, particularly at the separator surface, and electrochemically active area. In conclusion, the results highlight the need for holistic electrode design strategies.

Alkaline↗

Alchemy: A Model-Based Approach for 2D to 3D Autonomous Nuclear System Design

Engineering design of nuclear power plant (NPP) piping and equipment systems frequently bypasses crucial 2D system planning, instead moving straight to 3D modeling. This often leads to designs that exceed building envelope constraints, forcing expensive and time-consuming redesigns. When 2D modeling is employed, it typically involves labor-intensive manual workflows that convert 2D drawings into 3D models, resulting in inefficiencies and errors across design iterations. These workflows further suffer from poor software interoperability and dependence on proprietary software ecosystems, thereby contributing to schedule delays and cost overruns. This paper presents Alchemy, an autonomous framework that transforms 2D system definitions into Industry Foundation Classes (IFC)-compliant 3D building information models (BIMs) for expediting nuclear facility design at the conceptual preliminary phase. Using a model-based approach, the framework treats the 2D system diagram as the central reference model employed to automatically generate all subsequent outputs, ensuring consistency between the system definition and the resulting physical design. A web-based interface enables engineers to define hierarchical system topologies including associated equipment, geometric properties, and connectivity requirements. A two-phase equipment layout optimization algorithm automatically computes collision-free spatial configurations within predefined building envelopes. An artificial intelligence (AI)-assisted pipe routing module then generates orthogonal, collision-free routing paths, allowing the user to select either an A* search-based method or an Ant Colony Optimization (ACO)-based method. All outputs are authored natively in IFC format, relying on open-source technologies and standardized formats in order to ensure extensibility and eliminate proprietary software dependencies. The proposed framework is validated on two representative pressurized-water reactor (PWR)-based case studies, for which it autonomously generates IFC-compliant 3D models in minutes, drastically reducing workflows that typically require hours of manual effort. The generated model demonstrates topologically correct equipment placement, physically plausible spatial relationships, and collision-free pipe routing consistent with known PWR loop configurations. This work represents a foundational step toward digital engineering for nuclear facility preliminary design, with future ongoing development targeting design code compliance and expanded system complexity.

97 - MATHEMATICS AND COMPUTING↗

Flow Boiling Pressure Drop Characteristics of Next-generation Refrigerants in a Micro‑fin Copper Tube

This paper presents experimental frictional pressure-drop data for flow boiling of R-410A, R-134a, and next-generation alternatives R-454C, R-455A, R-1234yf, and R-1234ze(E) in a horizontal micro-fin copper tube. Tests were conducted over a range of mass fluxes and evaporation temperatures to characterize refrigerant-dependent two-phase pressure-drop behavior. The results show that frictional pressure gradient increased with mass flux and vapor quality and generally increased as evaporation temperature decreased, with liquid viscosity strongly affecting the observed trends. Among the evaluated correlations, the Goto et al. (2001) model gave the best overall agreement with the measurements before optimization. Further optimization of the Kuo and Wang (1996) and Goto et al. (2001) models reduced the overall mean absolute deviation to below 15%, with the optimized Goto (2001) model providing the most consistent predictions across all six refrigerants. The results support improved pressure-drop prediction and evaporator design for next-generation refrigerants in micro-fin tubes.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Resource-Adaptive Federated Text Generation with Differential Privacy

In cross-silo federated learning (FL), sensitive text datasets remain confined to local organizations due to privacy regulations, making repeated training for each downstream task both communication-intensive and privacy-demanding. A promising alternative is to generate differentially private (DP) synthetic datasets that approximate the global distribution and can be reused across tasks. However, pretrained large language models (LLMs) often fail under domain shift, and federated finetuning is hindered by computational heterogeneity: only resource-rich clients can update the model, while weaker clients are excluded, amplifying data skew and the adverse effects of DP noise. We propose a flexible participation framework that adapts to client capacities. Strong clients perform DP federated finetuning, while weak clients contribute through a lightweight DP voting mechanism that refines synthetic text. To ensure the synthetic data mirrors the global dataset, we apply control codes (e.g., labels, topics, metadata) that represent each client’s data proportions and constrain voting to semantically coherent subsets. This two-phase approach requires only a single round of communication for weak clients and integrates contributions from all participants. Experiments show that our framework improves distribution alignment and downstream robustness under DP and heterogeneity.

Wang, Jiayi [ORNL]↗

Carbon Tetrachloride Degradation Results for 200-ZP-1 Operable Unit

Carbon tetrachloride (CT) contamination in the 200-ZP-1 Operable Unit (OU) at the Hanford Site originated from large-volume discharges to the subsurface during plutonium production operations between 1955 and 1973. Contamination migrated through more than 70 meters of unsaturated sediment to reach the underlying unconfined aquifer, where it persists as a large and complex groundwater plume. The 200-ZP-1 OU Record of Decision (ROD) requires that groundwater CT concentrations be reduced to 3.4 µg/L within 125 years. Current groundwater modeling projections estimate that the existing pump-and-treat, even when combined with monitored natural attenuation (specifically hydrolysis), will not achieve this target within the designated timeframe. A fundamental contributor to this shortfall is the extremely slow rate of CT hydrolysis under Hanford aquifer conditions, which has been estimated to have a half-life of 630 years. If faster-acting biotic and abiotic degradation processes are operating within the aquifer, their contribution to CT mass reduction could have a meaningful impact. However, site-specific measurements of these processes and their rates have not previously been performed. This report documents the results of a two-phase laboratory investigation designed to characterize and quantify the capacity of site-specific 200-ZP-1 OU sediments and groundwater to support natural attenuation of CT through biotic and abiotic pathways. In this context, degradation capacity is defined as the intrinsic potential of the subsurface matrix to transform CT under optimized, controlled conditions. System capacity is evaluated in two ways: (1) as rate-limited capacity, which establishes the maximum kinetic velocity of CT transformation and is measured using half-lives and first order rate constants; and (2) as mass limited capacity, which defines the total contaminant mass the batch experimental system can degrade before reactants are exhausted, representing the maximum amount of contaminant the microbial community and reactive mineral phases can transform under the experimental conditions.

abiotic degradation↗

Advanced Multiphysics Code Coupling for Cladding Surface Thermocouples During Two-Phase Heat Transfer from Nuclear Fuel

Transient testing of nuclear fuel involves the evaluation of fuel performance under off-normal and accident conditions and is essential for proving design performance. Instrumentation included in such experiments commonly includes thermocouples attached to the outer surface of the cladding to provide temperature measurements throughout the transient. However, the presence of thermocouples on the cladding surface can alter the local heat transfer characteristics with the surrounding coolant. These localized effects can influence the temperature of the nearby cladding surface and introduce uncertainties in interpreting the thermocouple data. Understanding the impact of thermocouples attached to the outer surface of the cladding is crucial for accurate data interpretation as well as its effect on the thermomechanical behavior of the cladding. This paper presents a novel methodology for simulating the impact of outer cladding thermocouples during transient testing of nuclear fuels. The simulation framework leverages the thermal-hydraulic capabilities of RELAP5-3D coupled to the BISON fuel performance code through the RELAPCouplingApp interface. The methodology is compared against Accident Tolerant Fuel Reactivity Initiated Accident-1-E experiment performed at Idaho National Laboratory. The results reveal approximately 100°C difference between thermocouple-altered temperature and virgin cladding surface. The model overpredicts surface rewet time due to conservative correlations.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Theoretical analysis of a refrigerant injection-enhanced air source heat pump with thermal energy storage for extended cold-climate and defrosting operations

This study investigates a conceptual refrigerant injection-enhanced air source heat pump with integrated thermal energy storage (ITES-ASHP) that combines two-phase flash tank injection with phase change material (PCM) thermal energy storage (TES) to extend cold-climate operation and maintain indoor heating during defrost. A steady-state, mode-based thermodynamic cycle model is developed to evaluate heating and defrosting modes with and without refrigerant injection and TES integration over an outdoor temperature range of 8 to −25 °C. The framework is applied to refrigerants R-290, R-454B, R-410 A, and R-32. A parametric study is conducted for an 18-kW system rated for an outdoor temperature of 8 °C, with the compressor frequency scheduled to 150 Hz. The optimal PCM phase-change temperature is identified as 20 °C for R-290, R-454B, and R-410 A, and 15 °C for R-32. At the design condition of −25 °C outdoor temperature, the proposed concept achieves a combined COP of 2.22 for R-290, corresponding to a 60% increase relative to the theoretical single-stage baseline for combined heating and defrosting operation. Safety screening based on compressor discharge temperature (≤ 120 °C) and injection quality (≥ 0.65), together with performance evaluation, indicates that R-290 is the most suitable candidate, followed by R-410 A and R-454B. Under the assumptions and constraints used here, R-32 is found to be less suitable due to excessive discharge temperatures and a higher risk of wet compression.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Determining the extent of potential fugitive fluid migration from geologic carbon storage in hydrocarbon-bearing reservoirs: Insights from one-dimensional numerical modeling

Numerical modeling of Geologic Carbon Sequestration in permeable reservoirs initially containing hydrocarbons is conducted using the multi-phase, multi-component thermohydrologic simulator TOGA (TOUGH Oil, Gas, Aqueous; TOUGH stands for Transport Of Unsaturated Groundwater and Heat), to determine how phase and composition of the original fluids influence the extent of the zone where upward fugitive fluid migration could potentially occur, denoted R f . The area within R f comprises regions of substantially elevated pressure and free-phase CO 2 saturation, where a breach in reservoir sealing capacity would lead to upward fugitive fluid migration. The model examines the conditions within the storage reservoir that could lead to fugitive flow, but does not model the fugitive flow itself. A one-dimensional radial model of the storage reservoir is used, and three initial phase conditions are considered: single-phase aqueous, two-phase gas-aqueous, and three-phase oil-gas-aqueous. Components that may be present are H 2 O, CO 2 , CH 4 , C 4 H 10 , and C 10 H 22 . The most important factors controlling Rf are (1) the initial gas-phase saturation within the reservoir, and (2) the lateral extent of multi-phase initial conditions, particularly CO 2 . The composition of liquid and gas phases has a secondary effect. The impact of reservoir depth, thickness, injection rate, and hydrologic properties are also briefly examined, with thickness (or equivalently injection rate) having the biggest effect. These results can help to understand important trends in potential response of CO 2 -EOR fields being considered for dedicated CO 2 storage.

CO₂ plume migration↗