Search NASA⌕ Search

SEARCH · Search NASA

Results for “uncoating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Surface normal emissivity measurements in uncoated and oxidized B-coated plasma facing component materials in the long wavelength infrared spectrum

Accurate surface emissivity measurements are integral to the fidelity of the infrared thermography diagnostic evaluation in fusion reactors. The emissivities of ATJ TM graphite, Sigrafine® (R6510) graphite, and TZM alloy were measured as a function of temperature in accordance with the Contact Thermometer Method in the ASTM E1933 standard. Samples were heated resistively in a high-vacuum chamber, and the surface temperature was monitored using a surface thermocouple and a Telops long-wavelength infrared camera. The surfaces of Sigrafine® graphite and TZM alloy samples were coated with 10 nm and 20 nm layers of oxidized boron and were also measured in the uncoated condition. The thickness was assessed from measurement by a quartz crystal microbalance (QCM). ATJ TM graphite was uncoated. The measured emissivity of ATJ TM Graphite ranged from 0.82 to 0.83, uncoated Sigrafine® graphite ranged from 0.76 to 0.98, and uncoated TZM alloy ranged from 0.11 to 0.13. Oxidized boron coatings increased the emissivity of the TZM alloy to 0.18–0.23 but decreased the emissivity of Sigrafine® graphite to 0.56–0.66 for a 10 nm coating and to 0.65–0.74 for a 20 nm coating. In contrast to the expected blackbody radiance, the emissivity of uncoated Sigrafine® graphite and TZM alloy did not monotonically increase with temperature from 100 to 500 ℃.

Emissivity↗

Ablative performance of uncoated silicone-modified and shuttle baseline reinforced carbon composites

The relative ablative performance of uncoated silicone-modified reinforced carbon composite (RCC) and uncoated shuttle baseline RCC substrates was investigated. The test specimens were 13 plies (5.3 to 5.8 millimeters) thick and had a 25-millimeter-diameter test face. Prior to arc tunnel testing, all specimens were subjected to a heat treatment simulating the RCC coating process. During arc tunnel testing, the specimens were exposed to cold wall heating rates of 178 to 529 kilowatts/sq m and stagnation pressures ranging from 0.015 to 0.046 atmosphere at Mach 4.6 in air, with and without preheating in nitrogen. The results show that the ablative performance of uncoated silicone-modified RCC substrates is significantly superior to that of uncoated shuttle baseline RCC substrates over the range of heating conditions used. These results indicate that the silicone-modified RCC substrate would yield a substantially greater safety margin in the event of complete coating loss on the shuttle orbiter.

Dicus, D. L.↗

Effect of an oxygen plasma on uncoated thin aluminum reflecting films

Thin aluminum films were considered for use as a reflective surface for solar collectors on orbiting solar dynamic power systems. A matter of concern is the durability of such reflective coatings against oxidative attack by highly reactive neutral atomic oxygen, which is the predominate chemical specie in low Earth orbit. Research to date was aimed at evaluating the protective merit of thin dielectric coatings over the aluminum or other reflective metals. However, an uncoated aluminum reflector may self-protect by virtue of the oxide formed from its exposed surface, which constitutes a physical barrier to further oxidation. This possibility was investigated, and an attempt was made to characterize the effects of atomic oxygen on thin Al films using photomicrographs, scanning electron microscopy, spectrophotometry, Auger analysis, and mass measurements. Data collected in a parallel effort is discussed for its comparative value. The results of the investigation of uncoated aluminum supported the self-protection hypothesis, and importantly, it was found that long term specular reflectance for uncoated aluminum exceeded that of Al and Ag reflectors with dielectric coatings.

Parsons, Roger L.↗

Cyclic Oxidation Behavior of Cold Sprayed CuCrAl-Coated and Uncoated GRCop-84 Substrates for Space Launch Vehicles

A newly developed Cu-23 (wt %) Cr-5%Al (CuCrAl) alloy shown to resist hydridation and oxidation in an as-cast form is currently being considered as a protective coating for GRCop-84, which is an advanced copper alloy containing 8 (at.%) Cr and 4 (at.%) Nb. The coating was deposited on GRCop-84 substrates by the cold spray deposition technique. Cyclic oxidation tests conducted in air on both coated and uncoated substrates between 773 and 1073 K revealed that the coating remained intact and protected the substrate up to 1073 K. No significant weight loss of the coated specimens were observed at 773 and 873 K even after a cumulative cyclic time of 500 h. About a 10 percent weight loss observed at 973 and 1073 K was attributed to the excessive oxidation of the uncoated sides. In contrast, the uncoated substrate lost as much as 80 percent of its original weight under similar test conditions. It is concluded that the cold sprayed CuCrAl coating is suitable for protecting GRCop-84 substrates.

Raj, S. V.↗

Characterization of Cold Sprayed CuCrAl-Coated and Uncoated GRCop-84 Substrates for Space Launch Vehicles

A newly developed Cu-23(wt.%)Cr-5%Al (CuCrAl) alloy is currently being considered as a protective coating for GRCop-84 (Cu-8(at.%)Cr-4%Nb). The coating was deposited on GRCop-84 substrates by the cold spray deposition technique. Cyclic oxidation tests conducted in air on both coated and uncoated substrates between 773 and 1073 K revealed that the coating remained intact and protected the substrate up to 1073 K. No significant weight loss of the coated specimens were observed at 773 and 873 K even after a cumulative cyclic time of 500 h. In contrast, the uncoated substrate lost as much as 80% of its original weight under similar test conditions. Low cycle fatigue tests revealed that the fatigue lives of thinly coated GRCop-84 specimens were similar to the uncoated specimens within the limits of experimental scatter. It is concluded that the cold sprayed CuCrAl coating is suitable for protecting GRCop-84 substrates.

Raj, S. V.↗

Oxidation and thermal fatigue of coated and uncoated NX-188 nickel-base alloy in a high velocity gas stream

A cast nickel-base superalloy, NX-188, coated and uncoated, was tested in a high-velocity gas stream for resistance to oxidation and thermal fatigue by cycling between room temperature and 980, 1040, and 1090 C. Contrary to the behavior of more conventional nickel-base alloys, uncoated NX-188 exhibited the greatest weight loss at the lowest test temperature. In general, on the basis of weight change and metallographic observations a coating consisting of vapor-deposited Fe-Cr-Al-Y over a chromized substrate exhibited the best overall performance in resistance to oxidation and thermal fatigue.

Johnson, J. R.↗

The partitioned strainrange fatigue behavior of coated and uncoated MAR-M-302 at 1000 C (1832 F) in ultrahigh vacuum

Elevated temperature (1000 C (1832 F)) vacuum fatigue tests have been conducted on uncoated and aluminide (PWA 45) coated cobalt-base MAR-M-302 alloy with the four different types of thermalmechanical reversed inelastic strain cycles (wave shapes) defined by the method of strainrange partitioning. Results of these tests indicated two major conclusions. First, there was no significant influence of the aluminide coating on the thermal-mechanical fatigue life of the MAR-M-302 alloy. Second, variations in the type of thermal-mechanical fatigue cycle applied caused significant variations of fatigue life for both coated and uncoated material. The longest lives were achieved with sigma sub pp type cycling, while the sigma sub cc cycle caused a reduction of fatigue life of about 1/2 order of magnitude with respect to the sigma sub pp life. The sigma sub cp type cycle caused a life reduction of between 1-1/2 and 2 orders of magnitude relative to the sigma sub pp life, while the sigma sub pc type cycle provided a fatigue life which appeared to be comparable to that generated by the sigma sub cc cycle.

Sheffler, K. D.↗

Performance of uncoated AFRSI blankets during multiple Space Shuttle flights

Uncoated Advanced Flexible Reusable Surface Insulation (AFRSI) blankets were successfully flown on seven consecutive flights of the Space Shuttle Orbiter OV-099 (Challenger). In six of the eight locations monitored (forward windshield, forward canopy, mid-fuselage, upper wing, rudder/speed brake, and vertical tail) the AFRSI blankets performed well during the ascent and reentry exposure to the thermal and aeroacoustic environments. Several of the uncoated AFRSI blankets that sustained minor damage, such as fraying or broken threads, could be repaired by sewing or by patching with a surface coating called C-9. The chief reasons for replacing or completely coating a blanket were fabric embrittlement and fabric abrasion caused by wind erosion. This occurred in the orbiter maneuvering system (OMS) pod sidewall and the forward mid-fuselage locations.

Sawko, Paul M.↗

Raman Study of Uncoated and P-bn/sic-coated Hi-nicalon Reinforced Celsian Matrix Composites: Residual Stress in the Fibers - Part 2

Band shifts on Raman spectra were used to assess, at a microscopic scale, the residual strain existing in Hi-Nicalon fibers reinforcing celsian matrix composites. Uncoated as well as p-BN/SiC- and p-B(Si)N/SiC-coated Hi-Nicalon fibers were used as the reinforcements. We unambiguously conclude that the fibers are in a state of compressive residual stress. Quantitative determination of the residual stress was made possible by taking into account the heating induced by laser probing and by using a reference line, of fixed wavenumber. We found fiber compressive residual stress values between 110 and 960 MPa depending on the fiber/matrix coating in the composite. A stress relaxation-like phenomenon was observed at the surface of p-BN/SiC-coated Hi-Nicalon fibers whereas the uncoated or p-B(Si)N/SiC-coated Hi-Nicalon fibers did not show any stress relaxation in the Celsian matrix composites.

Gouadec, Gwenael↗

Arc Jet Screening Tests Of Phase 1 Orbiter Tile Repair Materials and Uncoated RSI High Temperature Emittance Measurements

Arc jet tests of candidate tile repair materials and baseline Orbiter uncoated reusable surface insulation (RSI) were performed in the Johnson Space Center's (JSC) Atmospheric Reentry Materials and Structures Evaluation Facility (ARMSEF) from June 23, 2003, through August 19, 2003. These tests were performed to screen candidate tile repair materials by verifying the high temperature performance and determining the thermal stability. In addition, tests to determine the surface emissivity at high temperatures and the geometric shrinkage of bare RSI were performed. In addition, tests were performed to determine the surface emissivity at high temperatures and the geometric shrinkage of uncoated RSI.

DelPapa, Steven V.↗

Experimental Setup and Parameters for Testing Uncoated and EBC-Coated CMCs under Thermal Gradients Induced by Laser Heating and Backside Air Cooling

An experimental setup to induce through thickness thermal gradients in ceramic matrix composite (CMC) specimens without and with an applied environmental barrier coating (EBC) is described in detail. Components of the experimental set up include a laser for the heat source on the front of the specimen, a cooling air nozzle on the back of the specimen with pyrometers to measure temperatures on both sides, and a full-field thermal image camera to ensure uniformity of the temperature distribution in the gage section of the specimen. Test specimen is loaded in a servohydraulic system, which can superimpose either static or dynamic loads on the specimen to investigate creep and fatigue behaviors of CMCs under through thickness thermal gradient conditions. Mechanical strains on the front and backsides of the test specimen were measured during the thermal gradient tests with superimposed mechanical loading using two contact extensometers. Selected through thickness thermal gradient test results generated with the experimental setup under different nominal front side temperatures and multiple constant laser power levels on uncoated and EBC coated CMCs and procedures used to generate those results are described in this report. Two examples of tests conducted using the test system on uncoated CMCs under creep and sustained-peak, low-cycle fatigue with through thickness thermal gradient conditions are provided.

ceramic matrix composite, environmental barrier co↗

Two-Year Mortality After Angioplasty of the Femoro-Popliteal Artery with Uncoated Balloons and Paclitaxel-Coated Balloons—A Pooled Analysis of Four Randomized Controlled Multicenter Trials

Purpose: In view of a recent meta-analysis reporting increased mortality following angioplasty with paclitaxel-coated devices in peripheral arteries, we performed a patient-level 2-year mortality analysis based on pooled original data of four randomized controlled trials (THUNDER, FEMPAC, PACIFIER and CONSEQUENT). Methods and Results: Clinical data of four randomized controlled trial were pooled to assess 2-year mortality following paclitaxel-coated balloon (PCB) angioplasty compared to angioplasty without paclitaxel (control group). A logistic regression model was applied to identify potential predictors of mortality. At two years, 13 of 185 (7.0%) patients had died in the control group and 16/184 (8.7%) in the PBC group, p = 0.55. Kaplan–Meier analysis revealed no significant difference from all-cause death at 2 years (log rank p = 0.54). Causes of death were well balanced between the groups with no pattern or trend in favour of any specific causes in the PBC group. Logistic regression revealed that treatment groups (controls or PBC) were not a predictor of 2-year mortality. The only predictor for mortality was patient age ≥ 75 years. The delivered paclitaxel doses per patient were not significantly different in patients that died and those who did not die during the 24-month follow-up (5.300 ± 4.224 μg vs. 6.248 ± 4.629 μg, p = 0.433). Conclusions: Based on original patient-level data of four pooled randomized controlled trials, we found no increase in 2-year mortality in patients treated with PCB compared to control patients treated with uncoated balloons. Causes of death were well balanced between PCB and control patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Combined Experimental and Modeling Approach to Investigate the Performance of Joint Between AZ31 Magnesium and Uncoated DP590 Steel Using Friction Stir-Assisted Scribe Technique

In this study, friction stir assisted scribe technique is used to achieve a viable joint between AZ31 magnesium alloy and uncoated DP590 steel. Here, the mechanical properties and performance of the joint are investigated using finite element modeling and electron microscopy. The joint strength can be ascribed to two factors, the mechanical interlocking and the metallurgical bonding of two materials at their interface. The contribution of both factors is intended, and the metallurgical bonding is studied to understand the basic joining phenomenon.

36 MATERIALS SCIENCE↗

Measurement and modeling of the multiwavelength optical properties of uncoated flame-generated soot

Optical properties of flame-generated black carbon (BC) containing soot particles were quantified at multiple wavelengths for particles produced using two different flames: a methane diffusion flame and an ethylene premixed flame. Measurements were made for (i) nascent soot particles,(ii) thermally denuded nascent particles, and (iii) particles that were coated and then thermally denuded, leading to the collapse of the initiallylacy, fractal-like morphology. The measured mass absorption coefficients(MACs) depended on soot maturity and generation but were similar between flames for similar conditions. For mature soot, here corresponding to particles with volume-equivalent diameters > ~ 160 nm, the MAC and absorption Ångström exponent (AAE) values were independent of particle collapse while the single-scatter albedo increased. The MAC values for these larger particles were also size-independent. The mean MAC value at 532 nm for larger particles was 9.1±1.1 m 2 g -1 , about 17 % higher than that recommended by Bond and Bergstrom (2006), and the AAE was close to unity. Effective, theory-specific complex refractive index(RI) values are derived from the observations with two widely used methods:Lorenz–Mie theory and the Rayleigh–Debye–Gans (RDG) approximation. Mietheory systematically underpredicts the observed absorption cross sections at all wavelengths for larger particles (with x >0.9 ) independent of the complex RI used, while RDG provides good agreement. (The dimensionless size parameter x = π d p / λ , where d p is particle diameter and λ is wavelength.) Importantly, this implies that the use of Mie theory within air quality and climate models, as is common, likely leads to under predictions in the absorption by BC, with the extent of underprediction depending on the assumed BC size distribution and complex RI used. We suggest that it is more appropriate to assume a constant,size-independent (but wavelength-specific) MAC to represent absorption by uncoated BC particles within models.

54 ENVIRONMENTAL SCIENCES↗

Ultrahigh vacuum, high temperature, low cycle fatigue of coated and uncoated Rene 80

A study was conducted on the ultrahigh vacuum strain controlled by low cycle fatigue behavior of uncoated and CODEP B-1 aluminide coated Rene' 80 nickel-base superalloy at 1000 C (1832 F) and 871 C (1600 F). The results indicated little effect of coating or temperature on the fatigue properties. There was, however, a significant effect on fatigue life when creep was introduced into the strain cycles. The effect of this creep component was analyzed in terms of the method of strainrange partitioning.

Kortovich, C. S.↗

A strainrange partitioning analysis of low cycle fatigue of coated and uncoated Rene 80

A strainrange partitioning analysis was conducted on ultrahigh vacuum, strain-controlled, low-cycle fatigue behavior of uncoated and aluminide coated Rene' 80 nickel-base superalloy at 1000 C (1832 F) and 871 C (1600 F). The results indicated little effect of coating or temperature on the fatigue resistance. There was, however, a significant effect on fatigue life when creep was introduced into the strain cycles. The effect of this creep component was analyzed in terms of the method of strainrange partitioning.

Kortovich, C. S.↗

Determination of hydrogen permeability in uncoated and coated superalloys

Hydrogen permeability, diffusivity, and solubility data were obtained for eight wrought and cast high temperature alloys over the range 650 to 815 C. Data were obtained for both uncoated alloys and wrought alloys coated with four commercially available coatings. Activation energies for permeability, diffusivity and solubility were calculated.

Bhattacharyya, S.↗

Tensile Strength and Microstructural Characterization of Uncoated and Coated HPZ Ceramic Fibers

Tensile strengths of as-received HPZ fiber and those surface coated with BN, BN/SiC, and BN/Si3N4 have been determined at room temperature using a two-parameter Weibull distribution. Nominally approx. 0.4 micron BN and 0.2 micron SiC or Si3N4 coatings were deposited on the fibers by chemical vapor deposition using a continuous reactor. The average tensile strength of uncoated HPZ fiber was 2.0 +/- 0.56 GPa (290 +/- 81 ksi) with a Weibull modulus of 4.1. For the BN coated fibers, the average strength and the Weibull modulus increased to 2.39 +/- 0.44 GPa (346 +/- 64 ksi) and 6.5, respectively. The HPZ/BN/SiC fibers showed an average strength of 2.0 +/- 0.32 GPa (290 +/- 47 ksi) and Weibull modulus of 7.3. Average strength of the fibers having a dual BN/Si3N4 surface coating degraded to 1.15 +/- 0.26 GPa (166 +/- 38 ksi) with a Weibull modulus of 5.3. The chemical composition and thickness of the fiber coatings were determined using scanning Auger analysis. Microstructural analysis of the fibers and the coatings was carried out by scanning electron microscopy and transmission electron microscopy. A microporous silica-rich layer approx. 200 nm thick is present on the as-received HPZ fiber surface. The BN coatings on the fibers are amorphous to partly turbostratic and contaminated with carbon and oxygen. Silicon carbide coating was crystalline whereas the silicon nitride coating was amorphous. The silicon carbide and silicon nitride coatings are non-stoichiometric, non-uniform, and granular. Within a fiber tow, the fibers on the outside had thicker and more granular coatings than those on the inside.

Bansal, Narottam P.↗