Search NASA⌕ Search

SEARCH · Search NASA

Results for “underground”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Underground Test Area Activity Waste Management Plan; and Attachment 1 Fluid Management Plan for the Underground Test Area Activity

The U.S. Department of Energy, National Nuclear Security Administration Nevada Field Office initiated the Underground Test Area Activity to characterize the risk posed to human health and the environment as a result of underground nuclear testing activities at the Nevada National Security Site. The UGTA Activity is now administered by the DOE Environmental Management Nevada Program. This document is a revision to NNSA/NSO (2009). The new document and revision number reflect EM Nevada Program as the current UGTA Activity administrator.

54 ENVIRONMENTAL SCIENCES↗

Optimizing Power Line Undergrounding Decisions under Varying Wildfire Risk and Weather Scenarios

Abstract—The threat of wildfire ignitions from electric power equipment has led utilities to increasingly turn to preemptive power shutoffs, which, while effective in reducing grid-induced wildfire risk, can cause significant load loss. Undergrounding power lines is an alternative strategy for preventing grid-induced wildfires. However, undergrounding lines is costly, so an efficient undergrounding plan must balance reductions in wildfire risk and load loss with the cost of undergrounding lines. We propose a robust optimization model to identify which power lines to underground to maximize load served while limiting wildfire risk across a range of wildfire risk and weather scenarios. Since solving this problem may be computationally heavy for large power grids and many operating scenarios, we present a delayed constraint generation algorithm to iteratively add scenarios until an optimal solution is found. We evaluate the performance of this framework on the RTS-GMLC with scenarios representing a year of operating conditions and compare it with a stochastic programming formulation. Our results indicate that our undergrounding model is successful in reducing load shed and risk compared to baseline cases in which no mitigation action is taken and only power shutoffs are implemented (no undergrounding). The robust formulation also reduces more load shed than the stochastic formulation in the most extreme scenarios. Index Terms—grid resilience, optimization, transmission systems, underground power lines, wildfire risk.

Taylor, S. [Department of Electrical and Computer ↗

Geothermal district energy systems coupled with seasonal underground thermal energy storage: a U.S. techno-economic screening by climate and geology

In the United States, cooling-dominated commercial building loads can cause geothermal heat pump-based district energy systems to accumulate a long-term subsurface thermal imbalance, motivating the incorporation of seasonal underground thermal energy storage. We developed a transferable workflow to evaluate geothermal district systems that pair ground heat exchangers with seasonal underground thermal energy storage. Using standardized hourly loads for seven commercial buildings and a uniform cost framework, we simulated ten U.S. cities with a physics-based ground heat exchanger model, subsurface storage simulations, and economic assessment to isolate the roles of climate and hydrogeology. In cooling-dominated cities, underground thermal energy storage supplied the majority of annual cooling, cutting electricity use and summer peaks substantially while achieving levelized costs comparable to or below conventional chiller-boiler plants. In cooler climates, the storage share shrunk, required borefield size and costs rose, and levelized cost of energy increased nearly linearly with declining underground thermal energy storage fraction, indicating storage fraction as the primary economic lever. Sensitivity analysis showed capital risk dominated by borefield drilling and surface heating, ventilation, and air-conditioning and piping, with underground thermal energy storage costs secondary. This workflow provides a transparent foundation for site-specific design and screening of next-generation geothermal district energy systems.

25 ENERGY STORAGE↗

Evaluating Radiation Impact on Transmon Qubits in Above and Underground Facilities

Superconducting qubits can be sensitive to abrupt energy deposits caused by cosmic rays and ambient radioactivity. Previous studies have focused on understanding possible correlated effects over time and distance due to cosmic rays. In this study, for the first time, we directly compare the response of a transmon qubit measured initially at the Fermilab SQMS above-ground facilities and then at the deep underground Gran Sasso Laboratory (INFN-LNGS, Italy). We observe same average qubit lifetime T$_1$ of roughly 80 microseconds at above and underground facilities. We then apply a fast decay detection protocol and investigate the time structure, sensitivity and relative rates of triggered events due to radiation versus intrinsic noise, comparing above and underground performance of several high-coherence qubits. Using gamma sources of variable activity we calibrate the response of the qubit to different levels of radiation in an environment with minimal background radiation. Results indicate that qubits respond to a strong gamma source and it is possible to detect particle impacts. However, when comparing above and underground results, we do not observe a difference in radiation induced-like events for these sapphire and niobium-based transmon qubits. We conclude that the majority of these events are not radiation related and to be attributed to other noise sources which by far dominate single qubit errors in modern transmon qubits.

Roy, Tanay↗

FY 2026 Midyear Report: Seismic Monitoring of Underground Vibration Sources Using Distributed Acoustic Sensing and Seismometers

Safeguards-relevant temporal changes in underground facilities can be observed using geophysical monitoring techniques. Seismic waves, in particular, provide valuable insights into subsurface activities and can serve as an important tool for detecting anomalous events that may indicate containment breaches at geological repositories. This midyear report summarizes ongoing efforts to automatically and rapidly detect and locate anomalous vibration signals that could be indicative of potential containment breaches. Previous work during FY25 focused on compiling continuous seismic datasets from two underground sites and developing a database of continuous waveforms and ground-truth event data derived from multiple sensing modalities. Building on this foundation, we are adapting anomaly detection and geolocation algorithms to explore methods for monitoring underground activities using two relatively low-maintenance sensing technologies: a dense surface geophone array deployed at the Pleasant Gap mine in Pennsylvania, and a three-dimensional fiber-optic cable array for distributed acoustic sensing (DAS) installed in the subsurface at the Sanford Underground Research Facility (SURF) in South Dakota. This report summarizes work conducted during the first two quarters of FY26, during which we refined a dynamic power spectral density (PSD)-based detector, applied it independently to each geophone station, and then combined the per‑station detections with density-based spatial clustering of applications with noise (DBSCAN) to cluster events and produce spatial maps over a nine‑day interval. In addition, we outline plans for a field trial at the Waste Isolation Pilot Plant (WIPP) in New Mexico to compare traditional seismic monitoring approaches with DAS techniques and to evaluate the benefits of combined data analysis. Activities during the past two quarters have included the preparation and submission of a Field Test Plan to WIPP for approval, as well as submission to headquarters for review and feedback.

58 GEOSCIENCES↗

A Corrosion Risk Assessment Model for Underground Piping

The Pressure Systems Manager at NASA Ames Research Center (ARC) has embarked on a project to collect data and develop risk assessment models to support risk-informed decision making regarding future inspections of underground pipes at ARC. This paper shows progress in one area of this project - a corrosion risk assessment model for the underground high-pressure air distribution piping system at ARC. It consists of a Corrosion Model of pipe-segments, a Pipe Wrap Protection Model; and a Pipe Stress Model for a pipe segment. A Monte Carlo simulation of the combined models provides a distribution of the failure probabilities. Sensitivity study results show that the model uncertainty, or lack of knowledge, is the dominant contributor to the calculated unreliability of the underground piping system. As a result, the Pressure Systems Manager may consider investing resources specifically focused on reducing these uncertainties. Future work includes completing the data collection effort for the existing ground based pressure systems and applying the risk models to risk-based inspection strategies of the underground pipes at ARC.

Datta, Koushik↗

Measurement of the Muon Flux at the Sanford Underground Research Facility with the LUX-ZEPLIN Dark Matter Detector

High-energy cosmic-ray muons reaching deep underground laboratories can cause events in detectors that mimic signals expected from dark matter particles, neutrinos, or rare decays. Knowledge of the muon flux and energy spectrum is important for evaluating the background rate caused by muons and their secondaries. In this paper, we report the measurement of the cosmic-ray muon flux in the Davis Campus of the Sanford Underground Research Facility with the LUX-ZEPLIN detector. Using 366.4~days of exposure, the muon rate through the detector was measured as $10.94\pm0.17_\textrm{stat.}~\textrm{day}^{-1}$ with energy thresholds of 20~MeV in the inner xenon detector and 8 MeV in the outer liquid scintillator detector. This rate corresponds to a muon flux of $(5.09\pm0.08_\textrm{stat.}\pm0.10_\textrm{sys.})\times10^{-9}~\textrm{cm}^{-2}\textrm{s}^{-1}$ in the Davis Cavern.

Akerib, D. S. [SLAC; Stanford U., Phys. Dept.; KIP↗

A comparison of long-term 37 Ar and 39 Ar transport and implications for 39 Ar as a persistent indicator of underground nuclear explosions

Measurements were first made in 2016 of legacy 39 Ar gas from the decades-old Barnwell underground nuclear explosion site within the Nevada National Security Site. This has raised the question of the ubiquity of the radionuclide 39 Ar following underground nuclear explosions in general locations. This article presents a high-level evaluation of the scientific case for using 39 Ar as a long-term indicator of underground nuclear explosions. Assessment is made based on a broad set of assumptions to reasonably estimate the persistence of 39 Ar in the subsurface environment following an explosion to establish potential detectability years to decades after the originating event.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Quantitative risk assessment examples for underground hydrogen storage facilities

Hydrogen energy storage can be used to achieve goals of national energy security, renewable energy integration, and grid resilience. Adapting underground natural gas storage facility (UNGSF) infrastructure for underground hydrogen storage (UHS) is one method of storing large quantities of hydrogen that has already largely been proven to work for natural gas. There are currently some underground salt caverns in the United States that are being used for hydrogen storage by commercial entities, but it is still a fairly new concept in that it has not been widely deployed nor has it been done with other geologic formations like depleted hydrocarbon reservoirs. Assessments of UHS systems can help identify and evaluate risks to people both working within the facility and residing nearby. This report provides example risk assessment methodologies and analyses for generic wellhead and processing facility configurations, specifically in the context of the risks of unintentional hydrogen releases into the air. Assessment of the hydrogen containment in the subsurface is also critically important for a safety assessment for a UHS facility, but those geomechanical assessments are not included in this report.

08 HYDROGEN↗

Evaluating Radiation Impact on Superconducting Transmon Qubits in Above and Underground Facilities

Superconducting qubits can be sensitive to sudden energy deposits into the substrate from cosmic rays and ambient radioactivity. While previous studies have primarily focused on exploring correlated effects over time and distance due to cosmic rays, this study uniquely offers a direct comparison of a transmon qubit's response at Fermilab SQMS above-ground facilities and the deep-underground Gran Sasso Laboratory (INFN-LNGS, Italy). Despite the vastly different radiation environments, we observe a similar average qubit lifetime (T1) of approximately 80 microseconds at both sites. We then employ a fast decay detection protocol and investigate the time structure, sensitivity, and relative rates of triggered events due to radiation versus intrinsic noise. We compare the above and underground performance of several high-coherence qubits with similar designs. Our findings reveal no significant difference in events with radiation-like signatures between above-ground and underground conditions for these sapphire and niobium-based transmon qubits. This suggests that most such events are likely due to other noise sources, which predominantly contribute to single-qubit errors in contemporary transmon qubits. By exposing the qubits to gamma sources with varying activity levels, we further evaluate their response to radiation in a low-background environment. The results show that qubits can indeed detect particle impacts; however, this capability is only realized by substantially reducing other noise sources, which in turn affects detection efficiency [1].

Roy, Tanay↗

Evaluating Radiation Impact on Transmon Qubits Using a Fast Decay Protocol in Above and Underground Laboratories

Superconducting qubits can be sensitive to sudden energy deposits caused by ambient radioactivity and cosmic rays. Previous studies have focused on understanding possible correlated effects over time and distance due to this radiation. In this study‚ for the first time‚ we directly compare the response of a transmon qubit measured initially at the SQMS above-ground facility (Fermilab‚ Illinois‚ USA) and then at the deep underground Gran Sasso Laboratory (INFN-LNGS‚ Italy). We observe the same average qubit lifetime of roughly 80 microseconds at both facilities. We then apply a fast decay detection protocol and investigate the time structure and relative rates of triggered events due to radiation versus intrinsic noise‚ comparing the above and underground performance of several high-coherence qubits. Using gamma sources of variable intensity we calibrate the response of the qubit to different levels of radiation in an environment with minimal background radiation. Results indicate that qubits respond to a strong gamma source‚ and it is possible to detect particle impacts. However‚ we do not observe a difference in radiation-induced-like events when comparing the above and underground results for niobium-based transmon qubits with sapphire substrates. We conclude that the majority of these events are not radiation-related and are attributed to other noise sources‚ which by far dominate single-qubit errors in modern transmon qubits. [1] Dominicis‚ Roy et al. arXiv:2405.18355

Roy, Tanay↗

Pilot-Scale Validation of Distributed Optical Fiber Sensors for Underground Pipeline Monitoring

Monitoring parameters such as hoop strain, pressure, and acoustic vibrations is key to detecting potential leaks, intrusions, or structural issues. Distributed optical fiber sensor (DOFS) systems provide a compelling solution for continuous, real-time monitoring over long distances. This paper details the development and pilot-scale implementation of DOFS systems for underground pipeline monitoring, evolving from a proof-of-concept stage. Multiple custom-designed DOFS interrogator units—such as optical frequency-domain reflectometry (OFDR), Brillouin optical time-domain analysis (BOTDA), and multimodal interferometer-based fiber acoustic sensor systems were tested to measure the key parameters, such as hoop strain, pipe pressure, surrounding soil temperature, and acoustic vibrations. The underground product pipeline’s outer diameter is 30 inches, the wall thickness is 1.28 inches, and 3 feet deep from the surface. The fiber deployment strategies and sensing data acquisition methods for these systems are discussed. The results demonstrate the effectiveness of DOFS in detecting hoop strain, temperature changes, and acoustic vibrations, showcasing their potential for real-time monitoring and enhancing pipeline safety. These findings from pilot-scale testing offer valuable insights into advancing pipeline monitoring technologies and improving the reliability of underground pipeline systems.

fiber optic sensors↗

Exploring the Nature of Neutrinos with the Deep Underground Neutrino Experiment (DUNE)

The Deep Underground Neutrino Experiment (DUNE) is a next-generation experimental program designed to study the behaviour of neutrino oscillation. DUNE will utilize a neutrino beam originating at Fermilab, near Chicago, and will leverage a detector at Fermilab (Near Detector) and a detector 1300 km away in South Dakota (Far Detector), south of Saskatchewan. In the first phase of DUNE, its Far Detector will comprise of two 10,000 ton (fiducial) liquid argon (LAr) time-projection chamber (TPC) modules – powerful tracking calorimeter detectors – placed nearly a mile underground. With this large, sensitive, underground detector, DUNE aims to collect a high statistics and pure sample of neutrinos at the Far Detector. This setup also offers the potential to study non-beam physical processes via e.g. neutrinos produced in the atmosphere, supernova neutrino bursts, and/or solar neutrinos, etc. A second phase will aim to add more detector mass and expand the program. The Near Detector will consist of a LAr TPC module as well: critical to constraining systematic uncertainties in the oscillation analysis. However, this LAr TPC will have a novel design using a pixel-based readout instead of the traditional wire-based readout. This and the segmentation of the LAr TPC into multiple units are crucial in mitigating the high multiplicity of neutrino interactions expected in any readout window given its proximity to the beam. The Near Detector will feature additional components and capability beyond the LAr TPC, allowing one to deeply characterize the neutrino flux. Due to the complexity of this experimental program, several smaller-scale prototype detectors have been operating to test, validate, and improve both the technical designs and software for processing and analyzing events. By operating in charged particle test beams or neutrino beams, several of the prototypes are also capable of producing valuable results. Canadian institutions are involved in the realization of the DUNE through efforts with both the Near and Far Detectors and prototypes. DUNE is anticipated to begin operating near the end of this decade/the beginning of the next. This talk will focus on the overall DUNE program, for example its ultimate plans, status, and the efforts with prototypes.

Howard, Bruce [York U., Canada; Fermilab]↗

Seismic monitoring of underground vibration: database of seismic data and ground truth

Seismic waves provide valuable insights into underground activities, serving as an essential tool for monitoring anomalies that could signal containment breaches in geological repositories. We aim to test and refine underground detection and geolocation techniques to identify anomalous vibration signals indicative of potential breaches, thereby strengthening georepository safeguards. We evaluate the effectiveness of two distinct, low-maintenance sensing technologies (surface geophones and underground distributed acoustic sensing (DAS) fiber optic cable) leveraging existing datasets. This report details the experimental designs, instrumentation, and data characteristics for both seismic and DAS arrays. Additionally, we provide a ground truth database documenting relevant operational activities for each experiment.

58 GEOSCIENCES↗

Underground storage systems for high-pressure air and gases

This paper is a discussion of the safety and cost of underground high-pressure air and gas storage systems based on recent experience with a high-pressure air system installed at Moffett Field, California. The system described used threaded and coupled oil well casings installed vertically to a depth of 1200 ft. Maximum pressure was 3000 psi and capacity was 500,000 lb of air. A failure mode analysis is presented, and it is shown that underground storage offers advantages in avoiding catastrophic consequences from pressure vessel failure. Certain problems such as corrosion, fatigue, and electrolysis are discussed in terms of the economic life of such vessels. A cost analysis shows that where favorable drilling conditions exist, the cost of underground high-pressure storage is approximately one-quarter that of equivalent aboveground storage.

Beam, B. H.↗

Underground mineral extraction

A method was developed for extracting underground minerals such as coal, which avoids the need for sending personnel underground and which enables the mining of steeply pitched seams of the mineral. The method includes the use of a narrow vehicle which moves underground along the mineral seam and which is connected by pipes or hoses to water pumps at the surface of the Earth. The vehicle hydraulically drills pilot holes during its entrances into the seam, and then directs sideward jets at the seam during its withdrawal from each pilot hole to comminute the mineral surrounding the pilot hole and combine it with water into a slurry, so that the slurried mineral can flow to a location where a pump raises the slurry to the surface.

Miller, C. G.↗

Atmospheric muons and neutrinos, and the neutrino-induced muon flux underground

The diffusion equation for neutrino-induced cosmic ray muons underground was solved. The neutrino-induced muon flux and charge ratio underground have been calculated. The calculated horizontal neutrino-induced muon flux in the energy range 0.1 - 10000 GeV is in agreement with the measured horizontal flux. The calculated vertical flux above 2 GeV is in agreement with the measured vertical flux. The average charge ratio of neutrino-induced muons underground was found to be mu+/mu- = 0.40.

Liland, A.↗

Evidence from the Soudan 1 experiment for underground muons associated with Cygnus X-3

The Soudan 1 experiment has yielded evidence for an average underground muon flux of approximately 7 x 10 to the minus 11th power/sq cm/s which points back to the X-ray binary Cygnus X-3, and which exhibits the 4.8 h periodicity observed for other radiation from this source. Underground muon events which seem to be associated with Cygnus X-3 also show evidence for longer time variability of the flux. Such underground muons cannot be explained by any conventional models of the propagation and interaction of cosmic rays.

Ayres, D. S. E.↗