Search NASASearch

SEARCH · Search NASA

Results for “units”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Free-flight Performance of 16-inch-diameter Supersonic Ram-jet Units II : Five Units Designed for Combustion-chamber-inlet Mach Number of 0.16 at Free-stream Mach Number of 1.60 (units B-1, B-2, B-3, B-4, and B-5) /c Wesley E. Messing and Scott H. S

Free-flight performance of five 16-inch-diameter ram-jet units was determined over range of free-stream Mach numbers of 0.50 to 1.86 and gas total-temperature ratios between 1.0 and 6.1 Time histories of performance data are presented for each unit. Correlations illustrate effect of free-stream Mach number and gas total-temperature ratio on diffuser total-pressure recovery, net-thrust coefficient, and external drag coefficient. One unit had smooth steady burning throughout the entire flight and encountered a maximum free-stream Mach number of 1.86 with a net acceleration of approximately 4.2 g's.

COMBUSTION - RAM-JET ENGINES

Free-flight Performance of 16-inch-diameter Supersonic Ram-jet Units III : Four Units Designed for Combustion-chamber-inlet Mach Number of 0.245 at Free-stream Mach Number of 1.8 (units D-1, D-2, D-3, and D-4)

Performance of four 16-inch-diameter ram-jet units was determined at free-stream Mach numbers of 0.49 to 1.78 over range of gas total-temperature ratios of 1.0 to 6.1. Time histories of each flight and data on thrust, drag, diffuser efficiency, and combustion are presented. A maximum thrust coefficient of 0.88 and a maximum net acceleration of 5.13 g's were observed for the four units.

COMBUSTION - RAM-JET ENGINES

HydroBio: Hydropower Capacity and Freshwater Biodiversity in Conterminous United States Sub-basins

This dataset summarizes existing and potential hydropower capacity and freshwater biodiversity at the sub-basin level throughout the conterminous United States (CONUS). It contains descriptive information regarding each sub-basin (e.g., 8-digit hydrologic unit code identifier, name, states, and size) along with sub-basin-level summaries of: 1) existing hydropower capacity (MW), 2) potential nominal non-powered dam (NPD) capacity (MW), 3) potential capacity of new stream reach development (NSD) (MW), and 4) freshwater biodiversity, including the total richness of fish, crayfish, and mussels and metrics that account for how rare and threatened those species tend to be. Hydropower data were obtained from Oak Ridge National Laboratory data resources (Existing Hydropower Assets, Non-Powered Dam Technical Potential, and New Stream Reach Development). Freshwater biodiversity data were obtained from NatureServe. Sub-basin characteristic information was obtained from the United States Geological Survey. Additionally, long data that provide lists of unique elements within each sub-basin for each constituent data resource (e.g., NatureServe, Existing Hydropower Assets) are provided to enhance dataset utility for users. The dataset provides, for the first time, a national-level assessment of existing and potential hydropower capacity in the context of freshwater biodiversity and is a valuable resource for stakeholders tasked with providing affordable, reliable energy to the American public while maintaining or enhancing invaluable freshwater resources. The dataset contains six data files in comma separated (*.csv) format that are within a zipped file.

Bozeman, Bryan [Oak Ridge National Laboratory (ORN

Geospatial characterization of low-temperature heating and cooling demand in residential, commercial, manufacturing, agricultural, and data center sectors for potential geothermal applications in the United States

Thermal demand for heating and cooling has been predominantly supplied by fossil fuel combustion in the United States, although low-carbon alternatives are extensively available including geothermal, solar thermal, and waste heat. Here, this study analyzed end-use energy consumption, fuel expenditure, and data center commissioned power data to geospatially characterize the U.S. low-temperature heating and cooling demand at the county level in residential, commercial, manufacturing, agricultural, and data center sectors and understand potential opportunities for geothermal applications. In the analysis, the regional-scale energy consumption data was incorporated with system efficiencies to address actual demand and was then disaggregated with weighting factors to the county level. The results indicated that total low-temperature heating and cooling demand is 16.7 EJ, combining heating demand of 10.8 EJ and cooling demand of 5.9 EJ. Overall, 59.9 % (10 EJ) of the low-temperature heating and cooling demand occurred in the residential sector. The heating and cooling demand visualized in maps represented that the geospatial distribution of heating and cooling demand in the residential and commercial sectors is governed by the number of housing units and climate zone designations, while heating and cooling demand in the manufacturing, agricultural, and data center sectors is dependent on the number and location of facilities. The results also demonstrated that geothermal heat pumps are broadly used in the residential and commercial sectors for heating and cooling in the U.S. Midwest, South, and Northeast regions but are limited in the West, implying great decarbonization potential in the future.

15 GEOTHERMAL ENERGY

Desert-Urban SysTem IntegratEd AtmospherIc Monsoon (DUSTIEAIM) in the Southwestern United States

Phoenix, Arizona, is the fifth-largest city in the United States with about 1.6 million residents. It is also considered to be the hottest major city in the country, having set a record of 31 consecutive days with temperatures above 110 F (43 C) in summer 2023. Phoenix depends on the Colorado River for over a third of its water supply, but there are questions about how much water will eventually be available to serve the rapidly growing metropolitan area, especially in such extreme heat. Current earth system models struggle to accurately capture precipitation in the Southwestern United States, especially in relation to the summertime North American Monsoon.

54 ENVIRONMENTAL SCIENCES

First Gale Western Butte Capping-Unit Compositions, and Relationships to Earlier Units Along Curiosity's Traverse

The Curiosity rover has been traversing through the clay-bearing unit (Glen Torridon; GT), approaching Greenheugh pediment, a large, fan-shaped surface surrounding the mouth of Gediz Vallis on the lower slope of Mt. Sharp. The pediment unconformably overlies the underlying bedrock, and is hence younger than units of the Mt. Sharp group. Orbital imaging of the pediment has shown it to have a slightly lower albedo and higher thermal inertia than neighboring units, to be relatively retentive of craters (e.g., erosion resistant), and to exhibit curved bedforms suggestive of lithified eolian bedforms. No diagnostic spectral signature has been observed from orbit. Recent rover positions allowed remote imaging of the contact between Greenheugh pediment and the eroded Murray formation strata below it, showing that the pediment capping material is cross-bedded and relatively thin (1-3 m), and suggesting that the pediment may have been much larger at one time. As Curiosity approached the edge of the pediment, the team investigated two buttes named Central and Western. The latter butte contains dark capping material that initially looked similar to the pediment cap, but close inspection revealed important physical differences. Here we report on compositions from ChemCam of two float rocks that appear to have rolled down from the capping unit, and on potential relation-ships to other targets along the traverse of the rover.

Wiens, R. C.

Topographic Trends of the Geologic Units in Jezero Crater: Lake Levels, Potential Shorelines, and the Crater Floor Units

The Mars2020 Perseverance rover continues to explore the crater floor of Jezero crater working to understand the origins of these different crater floor geological units. Here, we model and analyze the modern and paleo-topography of various facets of Jezero crater to better constrain the evolution and origins of the various units and features observed. In general, we find that that a) the evidences for lake levels are largely unconstrained and are primarily supported by the outflow channel, western delta, and Kodiak, b) so far no convincing evidence has been found for continuous lake terraces (i.e., shorelines), and c) the contact surface of the lobate Crater Floor Fractured Rough (Cf-fr)unit dips to the southeast.

S F Sholes

Simulations for Full Unit-memory and Partial Unit-memory Convolutional Codes with Real-time Minimal-byte-error Probability Decoding Algorithm

A program which was written to simulate Real Time Minimal-Byte-Error Probability (RTMBEP) decoding of full unit-memory (FUM) convolutional codes on a 3-bit quantized AWGN channel is described. This program was used to compute the symbol-error probability of FUM codes and to determine the signal to noise (SNR) required to achieve a bit error rate (BER) of 10 to the minus 6th power for corresponding concatenated systems. A (6,6/30) FUM code, 6-bit Reed-Solomon code combination was found to achieve the required BER at a SNR of 1.886 dB. The RTMBEP algorithm was then modified for decoding partial unit-memory (PUM) convolutional codes. A simulation program was also written to simulate the symbol-error probability of these codes.

Vo, Q. D.

Itegrated Test and Evaluation of a 4-Bed Molecular Sieve (4BMS) Carbon Dioxide Removtal System (CDRA), Mechanical Compressor Engineering Development Unit (EDU), and Sabitier Engineering Development Unit (EDU)

Currently on the International Space Station s (ISS) U.S. Segment, carbon dioxide (CO2) scrubbed from the cabin by a 4-Bed Molecular Sieve (4BMS) Carbon Dioxide Removal Assembly (CDRA) is vented overboard as a waste product. Likewise, the product hydrogen (H2) that will be generated by the Oxygen Generation Assembly (OGA) planned for installation will also be vented. A flight experiment has been proposed that will take the waste CO2 removed from the cabin, and via the catalytic Sabatier process, reduce it with waste H2 to generate water and methane. The water produced may provide cost and logistics savings for ISS by reducing the amount of water periodically re-supplied to orbit. To make this concept viable, a mechanical piston compressor and accumulator were developed for collecting and storing the CO2 from the CDRA. The compressor, accumulator and Sabatier system would be packaged together as one unit and referred to as the Carbon Dioxide Reduction Assembly (CRA). Testing was required to evaluate the performance of a 4BMS CDRA, compressor, accumulator, and Sabatier performance along with their operating rules when integrated together. This had been numerically modeled and simulated; however, testing was necessary to verify the results from the engineering analyses. Testing also allowed a better understanding of the practical inefficiencies and control issues involved in a fully integrated system versus the theoretical ideals in the model. This paper presents and discusses the results of an integrated engineering development unit test.

Knox, James C.

Designing and Implementing an OVERFLOW Reader for ParaView and Comparing Performance Between Central Processing Units and Graphical Processing Units

In the Applied Aerosciences and CFD branch at Johnson Space Center, computational simulations are run that face many challenges. Two of which are the ability to customize software for specialized needs and the need to run simulations as fast as possible. There are many different tools that are used for running these simulations and each one has its own pros and cons. Once these simulations are run, there needs to be software capable of visualizing the results in an appealing manner. Some of this software is called open source, meaning that anyone can edit the source code to make modifications and distribute it to all other users in a future release. This is very useful, especially in this branch where many different tools are being used. File readers can be written to load any file format into a program, to ease the bridging from one tool to another. Programming such a reader requires knowledge of the file format that is being read as well as the equations necessary to obtain the derived values after loading. When running these CFD simulations, extremely large files are being loaded and having values being calculated. These simulations usually take a few hours to complete, even on the fastest machines. Graphics processing units (GPUs) are usually used to load the graphics for computers; however, in recent years, GPUs are being used for more generic applications because of the speed of these processors. Applications run on GPUs have been known to run up to forty times faster than they would on normal central processing units (CPUs). If these CFD programs are extended to run on GPUs, the amount of time they would require to complete would be much less. This would allow more simulations to be run in the same amount of time and possibly perform more complex computations.

Chawner, David M.

HydroFish: freshwater fish co-occurrence with hydropower plants and non-powered dams in conterminous United States sub-basins

The HydroFish dataset lists all existing hydropower plants (EHAs) and non-powered dams (NPDs; ≥ 0.001 MW potential nominal capacity), delineates the hydrologic sub-basins in which they are situated, and then lists all freshwater fish species reported to occur in those sub-basins. This dataset was compiled using the HydroBio dataset (https://hydrosource.ornl.gov/data/datasets/hydrobio/) and contains 24 total variables that describe hydrologic sub-basins, each unique EHA (plant ID and name, geographic coordinates, permit type, capacity, etc.) and NPD (ID value, known names, geographic coordinates, and estimated potential nominal capacity), and freshwater fish species in the sub-basin (common and scientific name, origin, and migratory and threat status). The HydroBio dataset was built using Oak Ridge National Laboratory’s Existing Hydropower Assets Dataset (2024 version) and Non-powered Dam Technical Potential Dataset (2024 version), and NatureServe’s fish species distribution dataset (2023 version). The dataset also contains summary variables that report the unique number of EHAs, NPDs, and freshwater fish species per sub-basin. The HydroFish dataset contains two unique data files: 1) a .csv metadata file describing the dataset variables, and 2) a .csv data file containing the actual dataset. Note that there may be many rows per unique existing hydropower plant or non-powered dam given that distinct species are listed per existing plant or NPD per sub-basin. The dataset is downloadable as a zip file containing the metadata and dataset files.

Bozeman, Bryan [Oak Ridge National Laboratory (ORN