Search NASA⌕ Search

SEARCH · Search NASA

Results for “unmoderated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Uranium–Molybdenum Alloy Critical Experiments for the Design of the Health Physics Research Reactor

Clean critical experiments with a uranium-molybdenum alloy (average of 10.1616 wt. % Mo with a density of 17.08 g/cm 3 ) were performed at the Oak Ridge Critical Experiments Facility in 1961 to support the design of the Health Physics Research Reactor (HPRR). The HPRR was similar to the Godiva burst reactor at Los Alamos National Laboratory and was designed to produce 50 microseconds burst of 10 17 fission pulses of radiation for dosimetry measurements, initially in support of the determination of the doses from the nuclear detonations in Japan during World War II. These experiments reported here were used to verify the calculational methods used to design the HPRR. These delayed critical measurements were:1) a solid unreflected and unmoderated 8-in.-dimeter U-Mo cylinder, 2) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void, 3) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void filled with stainless steel, 4) Same as 3) but with 3-in-thick Plexiglas reflector on top with and without cadmium between the reflector and the U-Mo alloy assembly with steel in the center, and 5) an unmoderated and unreflected annulus which was a modification of the second but with the lower 5 inches of the central hole enlarged to 3.5 in. with various reflector conditions. The reflector conditions were: 1-in.-thick Plexiglas on all outer surfaces-void in the center; 1-in.-thick Plexiglas on all outer surfaces-Plexiglas in the center; 2-in.- thick Plexiglas on radial surface-void in the center; 6-in.-thick Plexiglas on the bottom only-Plexiglas in the center; and 6-in.-thick Plexiglas on bottom, 1-in.-thick on top and on the lower 8.25-cm.-section of the radial surface-void in the center. For some of these reflector conditions 0.025-cm.thick cadmium was located between the reflector and the U-Mo alloy. The uranium contained 93.17 wt. % 235 U. Reflection was a safety concern for this unmoderated and unreflected reactor and reduction of reflection effects was also investigated by insertion of neutron absorber around the U-Mo alloy. The stainless steel 304 contained 18% nickel and 8% chromium and the rest iron. The reflector material was a methacrylate plastic (Plexiglas) containing 5.8 x 10 22 atoms/cm 3 of hydrogen and 3.6 x 10 22 atoms/cm 3 of carbon with a density of 1.20 g/cm 3 . The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a EURATON Nuclear Energy Agency (NEA) benchmark. The data from the experiments described should be acceptable for use as criticality safety benchmark experiments for the ICSBEP and the NEA nuclear criticality safety benchmark program, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainties in k eff could be as low as ±0.0002 for some configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Delayed Critical Highly Enriched Uranium Metal Cylinders with Thin Graphite Top and Bottom Reflectors

Nine 7, 11, and 15 in. diam highly enriched uranium (HEU, 93.15 wt % 235 U) metal cylinders were assembled on the vertical assembly machine in the Oak Ridge Critical Experiments Facility (ORCEF) and had 1, 2, or 3 in. thick HLM graphite reflectors on the top and bottom. The experiments, which were performed between April 3, 1970, and February 18, 1971, used 23 operational days at ORCEF. Before those experiments were carried out, unreflected and unmoderated, graphite- and polyethylene-reflected, and polyethylene-moderated HEU metal cylinders had been assembled to obtain delayed criticality at ORCEF in the 1960s and reported by the International Criticality Safety Benchmark Evaluation Project (ICSBEP) at the Nuclear Energy Agency (NEA)*. The data from the nine critical experiments are acceptable for use as criticality safety benchmark experiments for the NEA’s ICSBEP once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with HEU metal at ORCEF, the uncertainties in k eff are expected to be as low as ±0.0004.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A neutron fluence map of the Los Alamos National Laboratory Godiva IV critical assembly

A neutron fluence map and a total ionizing dose map of the Los Alamos National Laboratory Godiva IV fast burst critical assembly was generated using passive reactor dosimetry, comprised of sulfur pellets and thermoluminescent dosimeters. Godiva IV is an unmoderated, fast burst, critical assembly constructed of approximately 65 kg of highly enriched uranium fuel alloyed with 1.5 % molybdenum for strength. The mapping was performed during a single 75.6 ºC temperature rise burst operation, with the top and sides of the cylindrical Godiva-IV Top Hat covered in passive dosimetry. Dosimetry was placed in a symmetric pattern around the Top Hat, with higher concentrations near the control rods and burst rod. A specific portion of the lower quadrant of the burst rod was mapped to confirm a testing region where the neutron fluence varied by no more than ± 5%. The results will be used to assess the neutron, gamma, and total ionizing dose environment in three-dimensional space around the assembly for higher fidelity experiment placement, active dosimetry positioning, and radiation field characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation characterization summary of the NETL beam port 1/5 free-field environment at the 128-inch core centerline adjacent location

The characterization of the neutron, prompt gamma-ray, and delayed gamma-ray radiation fields in the University of Texas at Austin Nuclear Engineering Teaching Laboratory (NETL) TRIGA reactor for the beam port (BP) 1/5 free-field environment at the 128-inch location adjacent to the core centerline has been accomplished. NETL is being explored as an auxiliary neutron test facility for the Sandia National Laboratories radiation effects sciences research and development campaigns. The NETL reactor is a TRIGA Mark-II pulse and steady-state, above-ground pool-type reactor. NETL is intended as a university research reactor typically used to perform irradiation experiments for students and customers, radioisotope production, as well as a training reactor. Initial criticality of the NETL TRIGA reactor was achieved on March 12, 1992, making it one of the newest test reactor facilities in the US. The neutron energy spectra, uncertainties, and covariance matrices are presented as well as a neutron fluence map of the experiment area of the cavity. For an unmoderated condition, the neutron fluence at the center of BP 1/5, at the adjacent core axial centerline, is about 8.2×10 12 n/cm 2 per MJ of reactor energy. About 67% of the neutron fluence is below 1 keV and 22% above 100 keV. The 1-MeV Damage-Equivalent Silicon (DES) fluence is roughly 1.6×10 12 n/cm 2 per MJ of reactor energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation characterization summary for the WSMR fast burst reactor environment at the 6-inch location

The characterization of the neutron, prompt gamma-ray, and delayed gamma-ray radiation fields for the White Sands Missile Range (WSMR) Fast Burst Reactor, also known as molybdenum-alloy Godiva (Molly-G) has been assessed at the 6-inch irradiation location. The neutron energy spectra, uncertainties, and common radiation metrics are presented. Code-dependent recommended constants are given to facilitate the conversion of various dosimetry readings into radiation metrics desired by experimenters. The Molly-G core was designed and configured similarly to Godiva II, as an unreflected, unmoderated, cylindrical annulus of uranium-molybdenum-alloy fuel with molybdenum loading of 10%. At the 6-inch position, the axial fluence maximum is about 2.4×10 13 n/cm 2 per MJ of reactor energy; about 0.1% of the neutron fluence is below 1 keV and 96% is above 100 keV. The 1-MeV Damage-Equivalent Silicon (DES) fluence is estimated at 2.2×10 13 n/cm 2 per MJ of reactor energy. The prompt gamma-ray dose is roughly 2.5E+03 rad(Si) per MJ and the delayed gamma-ray dose is about 1.3E+03 rad(Si) per MJ.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Gallium oxide (Ga 2 O 3 ) energy dependent scintillation response to fast neutrons and flash gamma-rays

Gallium oxide is a newly emerged ultrawide bandgap (4.9 eV) semiconductor that is suitable as a combined electronics and radiation detection platform. We have experimentally demonstrated fast neutron and gamma-ray scintillation from Czochralski-grown β-Ga 2 O 3 in a recent series (October 2023) of experiments at the unmoderated pulsed neutron spallation source located at the Los Alamos Neutron Science Center. Using the neutron time-of-flight (TOF) technique and a fast-gated intensified CCD camera, we observed energy-dependent neutron scintillation for neutron energies ranging from 1 to 400 MeV, including the 14.1 MeV neutron energy relevant to D–T fusion. Neutron flux is quantified and calibrated by cascading the scintillator after the fission chamber, enabling a detailed analysis of temporal and energy-dependent characteristics of the scintillation events. Further, a pronounced scintillation signal from the spallation gamma flash with a temporal full width of half maximum of ~4 ns is indicative of the material’s rapid response. Neutron energy dependent scintillation is observed using the TOF method at a 22.6-m distance from the neutron source. These results highlight the possibility of developing a Ga 2 O 3 based fusion neutron diagnostic platform integrated with both scintillation and electronics functions on the integrated chip scale.

47 OTHER INSTRUMENTATION↗

Nonstatistical fluctuations in the 35 Cl(n,p) 35 S reaction cross section at fast-neutron energies from 0.6 to 6 MeV

The lack of experimental data on the 35 Cl(n,p) 35 S reaction above 100 keV has led to nuclear data evaluations that are relatively unconstrained at fast neutron energies. As a result, efforts to explore, develop, and potentially certify next generation reactor designs that incorporate chloride salts as a coolant material have been hindered. Here, we report partial cross section data for the 35 Cl(n,p) 35 S and 35 Cl(n,α) 32 P reactions at incident neutron energies between 0.6 MeV and 6 MeV. The measurement was performed using the pulsed beam of neutrons at the unmoderated WNR spallation neutron source at the Los Alamos Neutron Science Center, with the outgoing charged particles detected by the LENZ experimental setup, consisting of annular silicon detectors. Nonstatistical fluctuations in the 35 Cl(n,p 0 ) cross section were observed up to around 3 MeV, and the magnitude of the cross section was systematically lower than all available data evaluations at energies above 1 MeV. Modifications to the ENDF/B-VIII.0 data evaluation are suggested to better reproduce the energy averaged experimental data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Differential cross sections of the 16 O (𝑛,𝛼) reaction at neutron energies from 3.8 to 15 MeV

The importance of studying the 16 O (𝑛,𝛼) reaction is motivated by multiple nuclear applications which rely on an accurate nuclear reaction data library for oxygen. Discrepancies between past experimental data on the 16 O (𝑛,𝛼) 13 C reaction and its time-reverse 13 C ⁡(𝛼,𝑛) 16 O reaction have led to various different nuclear data evaluations. Here, we have measured 16 O (𝑛,𝛼) reaction cross sections using the LENZ instrument with the unmoderated white neutron source at LANSCE. Results from 2016/2017 data are discussed and used to benchmark the mcnp and geant simulations of the LENZ experimental setup. We report partial differential cross sections of 16 O (𝑛,𝛼 0 ) at 𝐸 𝑛 = 3.8–15 MeV and 16 O ⁡(𝑛,𝛼 1 +𝛼 2 +𝛼 3 ) at 𝐸 𝑛 =9–15 MeV, based on the new measurement in 2021. The resonances that we observed are in good agreement with the levels in 17 O that were previously measured. The LENZ cross sections are in better agreement with the ENDF/B-VIII.0 evaluation than the with reduced cross section found in ENDF/B-VII.1 up to 6 MeV. However, the current results for 16 O ⁡(𝑛,𝛼 0 ) 13 C g.s. appear to be in the best agreement over the entire energy range with that of JENDL/AN-2005 (ENDF/B-VI.0).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Health Physics Research Reactor Criticality Accident Alarm System Benchmark Overview

From the countless critical experiments performed in the world during the past century, high-quality integral benchmarks experiments have been collected and gathered into the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook), managed by the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Working Group. This information preservation and dissemination effort is crucial for reactor licensing as well as criticality and radiation transport modeling validation. This summary reports on the status of a tentative benchmark addition to the ICSBEP Handbook. The proposed benchmark arises from legacy operation data of the Oak Ridge National Laboratory (ORNL) Health Physics Research Reactor (HPRR). The HPRR was a small, unmoderated, unshielded fast burst reactor that was used for research in health physics and radiobiology as well as teaching and training. As part of a comprehensive investigation of the available HPRR operation data and characteristics, different possibilities for use of the valuable results were studied. A critical experiment benchmark evaluation was performed, analyzing data coming from sub-critical and critical operation of the HPRR during operator training, steady-state irradiation of samples and before critical bursts. The results of the evaluation do not satisfy for the ICSBEP standards as the benchmark relative standard uncertainty is of about 4% for k eff , and the relative difference between sample calculations and expected k eff results is of about 1.5%. Due to those unsatisfactory results, it was decided not to pursue critical experiments evaluation of the HPRR presently and to focus instead on shielding type data for the creation of a criticality accident alarm system (CAAS) and shielding category benchmark, which is currently very scarce in the ICSBEP handbook—especially concerning critical, pulsed assembly, or reactor operation data. Several dosimetry and shielding experiments from HPRR burst operation were evaluated, with different benchmark metrics as sulfur fluence, Element 57 dose, or neutron fluence at different distances and under different shield materials conditions. An evaluation focusing on the Element 57 neutron dose as a benchmark metric was submitted to the ICSBEP Technical Review Group (TRG) meeting in October 2021, and the inclusion of the evaluation in the ICSBEP Handbook was deferred. The main change proposed by the international experiment evaluation experts is to use the neutron fluence measured by Bonner spheres as a benchmark metric. This represents a quantity closer to that actually measured by the experimentalists of the HPRR compared to the Element 57 dose, which adds another step of data transformation, thus potentially adding uncertainty to the benchmark. The evaluation has been updated and will be submitted to the 2022 ICSBEP TRG meeting for inclusion in the 2023 edition of the ICSBEP Handbook. The evaluation is performed using the KENO and MAVRIC combination from the SCALE 6.2.4 code suite which was previously used in similar CAAS benchmarks to allow for the use of variance reduction techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

Neutronics Modeling of the pulsed plasma rocket reactor using rattlesnake

In the pulsed plasma rocket (PPR) reactor, neutron induced fission processes are utilized to implement a series of pulsed micro-explosions of very high power and eject plasma as a propellant. More specifically, projectiles (bullets) composed of moderated uranium are sent through the chamber of an unmoderated uranium barrel. By inducing rapid fission within the bullets, a plasma can be generated with appropriate delivery of neutrons. This study aims to assess the neutronics performance of the PPR reactor during normal operations using the MOOSE-based Rattlesnake code through the evaluation of the impact of the movement of the fuel bullet and the rotation of control drums on the criticality of the system. The Monte Carlo (MC) code Serpent 2 was employed to generate material-based cross sections for use in Rattlesnake and the reference neutronics solution. Cubit was used to generate the mesh for the Rattlesnake model. Parametric studies were conducted to evaluate the best approaches for cross section and mesh generation to ensure accurate results from Rattlesnake. As part of the verification process, the eigenvalue results of the system at various fuel bullet positions were obtained using Rattlesnake and compared with the reference solutions. The acceptable differences show that the Rattlesnake model with appropriate cross section and mesh generation procedure is a sufficiently accurate approximation of the continuous energy (CE) MC model for micro-sized reactors like the PPR reactor. Next, the impact of the rotation of the control drums on the system criticality was evaluated using the verified model. It was shown that the high-fidelity simulation using the deterministic code Rattlesnake can produce sufficiently accurate results for the evaluation of the reactor's neutronics performance in different phases of the normal operation with acceptable computational cost.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity-based Experiment Design Optimization for a Molybdenum Critical Experiment

A lack of intermediate molybdenum benchmarks in the ICSBEP has been identified by LANL, Y-12, and IRSN. This lacking adversely effects criticality safety operations and leaves new differential molybdenum data unvalidated. NCERC is proposing a series of intermediate integral experiments to better the understanding of molybdenum systems. Using MCNP6.2 with the ENDF/B-VIII.0 nuclear data library a single unmoderated and four moderated system designs were identified using a sensitivity optimization method. Each proposed system was found to be at least twice as sensitive to the 95 Mo capture cross section in the URR as the sole existing intermediate molybdenum benchmark in the ISCBEP handbook. The addition of a new molybdenum sensitive intermediate system would improve future nuclear data evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Two Delayed Critical 15-Inch-Diameter Interacting Enriched (93.14) Uranium Metal Cylinders without Moderator and Reflector

This report documents very accurately the configuration and the materials for experiments with two unmoderated, unreflected, interacting, coaxial, highly enriched, 15-in.-diameter, uranium metal cylinders performed at the Oak Ridge Critical Experiments Facility (ORCEF) in May to Aug 1963 and described in logbook E-19 and E -20 associated with experiments in the East cell of ORCEF. Measurements were also performed in April and May of 1965 and described in logbooks E-22 and E-23 The information is sufficiently accurate that it can be used as the basis for preparation of benchmarks for International Criticality Safety Benchmark Program (ICSBEP) at Idaho National laboratory. The thickness of the cylinders was varied and the spacing between them was adjusted to achieve a delayed critical configuration. The average enrichment of the uranium metal was 94.14 wt. % 235 U. The heights of the 15-in.-diameter, equal-height cylinders varied from 1-5/8 to 3.0-inches. All interacting cylinders were assembled coaxially with their flat faces parallel and their combined masses varied between 182 and 325 kilograms of HEU metal. The data from these 12 experiments described would be acceptable for use as criticality safety benchmark experiments for the ICSBEP and EURATOM’s Nuclear Energy Agency nuclear criticality safety benchmark program, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, it is expected that the uncertainties in k eff could be as low as ± 0.0002.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Three Delayed Critical 15-Inch-Diameter Interacting Enriched (93.14) Uranium Metal Cylinders Without Moderator and Reflector

This report documents very accurately the configuration and the materials for experiments with three unmoderated, unreflected, interacting, coaxial, highly enriched, 15-in.-diameter, uranium metal cylinders performed at the Oak Ridge Critical Experiments Facility (ORCEF) in August and September 1963 and described in logbook E 20 associated with experiments in the East cell of ORCEF. The information is sufficiently accurate that it can be used as the basis for preparation of benchmarks for International Criticality Safety Benchmark Program (ICSBEP) at Idaho National laboratory. The thickness of the cylinders was varied and the spacing between them was adjusted to achieve a delayed critical configuration. The average enrichment of the uranium metal was 94.14 wt. % 235U. The heights of the 15-in.-diameter, equal-height cylinders varied from 1-1/8to 2.00 inches. All interacting cylinders were assembled coaxially with their flat faces parallel and their combined masses varied between 182 and 325 kilograms of HEU metal. The data from these six experiments described are judged to be acceptable for use as criticality safety benchmark experiments for the ICSBEP and EURATOM’s Nuclear Energy Agency nuclear criticality safety benchmark program, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, it is expected that the uncertainties in measured keff could be as low as ± 0.0002.

36 MATERIALS SCIENCE↗

Sulfur Pellets Responses to a Bare and Steel Reflected Pulse of the Oak Ridge National Laboratory Health Physics Research Reactor

The experiments analyzed in this report were conducted at the Health Physics Research Reactor (HPRR), also known as the $\textit{Fast Burst Reactor}$. The reactor was designed and built at Oak Ridge National Laboratory (ORNL) in 1961. The HPRR was an unmoderated, unshielded fast reactor that used highly enriched uranium and molybdenum alloy as fuel. The reactor was initially sent to the Nevada Test Site in 1962, where it was used to evaluate radiation doses received as a result of the Hiroshima and Nagasaki bombings during World War II. A few years later, the reactor was sent back to ORNL to be part of the Dosimetry Application Research (DOSAR) facility shown in Figure 1, which included a reactor building shown on the left (west) of the picture and a control and laboratory building in the upper right corner (northeast). The critical assembly was used for numerous technical studies, including systems calibration, dosimetry, radiobiology of plants and animals, testing of radiation alarms, as well as teaching and training in radiation dosimetry and nuclear engineering. Between 1963 and 1987, the HPRR was operated for thousands of hours, achieving criticality close to 10,000 times and motivating many publications. The HPRR was decommissioned in 1987. The goal of this effort was to use historical data from operation of the HPRR to create a criticality accident alarm system (CAAS) benchmark to be included in the $\textit{International Handbook of Evaluated Criticality Safety Benchmark Experiments}$ (ICSBEP Handbook). A thorough inspection was performed of all available documentation and information available. The most promising experiments that were selected for evaluation were those described in the 1987 ORNL report entitled $\textit{Health Physics Research Reactor Reference Dosimetry}$, ORNL-6240. The report includes reference dosimetry results of the shielded and unshielded configurations of the HPRR after burst operations. Because of changes to the reactor positioning and storage systems that were made in 1985, the previous dosimetry reports became obsolete, and the newly designed experiments were needed to create the HPRR’s adjusted dosimetry data. The various results reported in ORNL-6240 include reference doses and dose equivalents from different conventions at different distances and elevations as determined using the detected neutron fluence and conversion factors. The HPRR neutron fluence was obtained through different methods, including sulfur pellet analysis and threshold detector unit data. Information about the HPRR spectrum was also obtained through Bonner sphere measurements. This benchmark is focused on a part of the measured sulfur fluences reported in Appendix H of ORNL-6240. Standard commercial sulfur pellets were placed at different distances from the HPRR centerline during burst operation and were activated due to the 32 S(n,p) 32 P reaction. The resulting 32 P activity was then measured and the information about the corresponding sulfur fluence and/or neutron dose could be extracted. Many of those measurements have 7 been performed with the HPRR in its bare configuration or with different shields (combinations of Lucite, concrete, steel). All the necessary, precise information about material and/or dimensions of the different shields was not found, so it was decided to focus only on the unshielded and steel-shielded configurations to minimize the benchmark uncertainty. A total of 31 cases (24 unshielded and 7 shielded cases at different positions) of sulfur fluence were selected before evaluation to develop the benchmark.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Subcritical Californium Source Drive Noise Analysis Measurements With Unreflected Uranium (93.15) Hydride

On July 6, 1989, subcritical californium source-driven noise analysis (CSDNA) measurements were performed with bare uranium hydride cylindrical assemblies at the Los Alamos National Laboratory Critical Experiments Facility in KIVA 1. Three configurations of ~7.5 cm radius-enriched (93.15 wt. % 235 U) uranium hydride with a density of ~10 g/cm 3 cylinders were assembled with uranium hydride heights of ~11, ~14, and ~16 cm. The uranium hydride (~2 and ~3 cm high) was in thin-welded stainless steel cans. The neutron multiplication factors obtained on-line from the measured ratios of spectral densities were 0.942 ± 0.002, 0.917 ± 0.003, and 0.867 ± 0.004 for uranium hydride heights of ~16, ~14, and ~11 cm., respectively. Neutron multiplication factors for these three configurations calculated by Los Alamos National Laboratory Monte Carlo methods were 0.952 ± 0.005, 0.922 ± 0.005, and 0.860 ± 0.005, all of which are in good agreement with the measurements. The break frequency noise analysis data could be fitted to obtain the prompt neutron decay constant at all subcritical states. Some data presented in this report are from notes that are not in the logbooks. A discussion of the two different point kinetics theories of the measurements that illustrated the deficiencies of the rigorous theory at low neutron multiplication factors (k eff < 0.80) is given in an Appendix. These measurements may be the only configuration of unreflected, highly enriched uranium hydride configuration assembled. The presence of hydrogen diluted the uranium density, decreasing the reactivity, but this is offset by slowing down the neutron energy to the energy ranges of higher-fission cross sections. Extrapolations to delayed critical indicate that adding one more 3 cm can and one more 2 cm can would result in the unreflected cylindrical system being slightly above critical with a critical mass of ~37 kg, which is considerably less than the critical mass of an unreflected and unmoderated highly enriched uranium metal sphere. An unreflected, highly enriched uranium hydride sphere would have a critical mass less than 37 kg.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Delayed Critical Enriched Uranium Metal, 7-in.-diam. Cylinder with Thin Stainless Steel Top and Bottom Reflectors

Three 7 in. diameter highly enriched uranium (HEU; 93.17 wt % 235 U) metal cylinders were assembled on the vertical assembly machine of the Oak Ridge Critical Experiments Facility (ORCEF) with thin stainless steel reflectors (0.5, 1, and 2 in. thick) on the top and bottom. These experiments were performed during January 13–25, 1965, and used seven operational days at ORCEF. Before these experiments, unreflected and unmoderated 7 in. diameter HEU metal cylinders had been assembled to delayed criticality at ORCEF, and the results were benchmarked in HEU-MET-FAST-051. In addition to the critical experiments, the prompt neutron decay constant was measured via the Rossi-α technique, and those results are also presented in this report. To achieve near-delayed-critical systems, 5 × 5 × 0.03125 in. rectangular uranium metal parts were used on top of 7 in. diameter cylinders inside the top reflector. The delayed critical configuration from the three experiments described herein are acceptable for use as criticality safety benchmark experiments for the International Criticality Safety Benchmark Evaluation Program (ICSBEP), coordinated by the Nuclear Energy Agency, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainty in $k_{eff}$ is expected to be as low as ±0.0002. The prompt neutron time decay data could be the basis of an International Reactor Physics Evaluation Program benchmark.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benchmark Gap Assessment for the Manufacturing of High-Assay Low-Enriched Uranium Fuels

This document develops basic critical conditions for spheres—moderated and unmoderated, as well as reflected and unreflected—in consideration of nuclear criticality safety of a potential fuel production facility producing high-assay low-enriched uranium (HALEU) fuel of several different types like tristructural-isotropic (TRISO), uranium metal and alloys, oxide and non-metallic forms. In addition to spherical arrangements, TRISO particle manufacturing process–specific equipment is modeled as it would be for the criticality safety analysis. The objective is to develop representative systems that can then be used for comparison with existing benchmarks. SCALE/TSUNAMI is used to assess the similarity index between these systems to assess validation gaps for possible fuel production applications of proposed advanced reactors. Several different fuel types were evaluated, including TRISO, uranium metal, uranium molybdenum, uranium zirconium, uranium dioxide, uranium nitride, uranium hydride, U-ZrH, and uranium chloride. This selection of fuel types covers a breadth of proposed reactor types, as well as intermediate steps in the production and fabrication of the fuel

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗