Search NASASearch

SEARCH · Search NASA

Results for “uranium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Quantification of uranium metal and total uranium in U-UO 2 mixtures using H 3 PO 4 -HCl

Here, the selective dissolution of uranium metal from its mixtures with UO 2 was studied to establish a simple and rapid quantitative method. Uranium metal was found to selectively dissolve as U(IV) into a solution of phosphoric and hydrochloric acids, with quantitative dissolution occurring within 1 h. Total dissolution of uranium as U(VI) could then be obtained by nitric acid addition and heating for 0.5–1 h. Analysis of the resulting U(IV) and U(VI) solutions by ICP-OES or UV–Vis spectroscopy yielded uranium metal-to-UO 2 ratios with an accuracy of ± 10% or better. Accuracy of the ICP-OES method was slightly better than UV–Vis, but the simplicity of the latter makes it an attractive option for some applications.

36 MATERIALS SCIENCE

Neutron and x-ray computed tomography of a natural uranium tristructural isotropic (TRISO) fuel compact

A natural uranium-based, unirradiated tristructural isotropic (TRISO) fuel compact was nondestructively imaged using both X-ray (XCT) and neutron computed tomography (nCT). While XCT of compacts can provide information on fuel kernels, imaging artifacts preclude examination of the graphite matrix. In this work, nCT was used for the first time on a TRISO compact to examine the graphite matrix. A crack was clearly resolved within the graphite matrix, proving that nCT is a viable tool for nondestructive volumetric examination of the matrix material in TRISO fuel compacts. The XCT and nCT data were then fused together to create a more comprehensive dataset containing both matrix and fuel kernels.

36 - MATERIALS SCIENCE

Evaluation of refractory-metal-clad uranium nitride and uranium dioxide fuel pins after irradiation for times up to 10 450 hours at 990 C

The effects of some materials variables on the irradiation performance of fuel pins for a lithium-cooled space power reactor design concept were examined. The variables studied were UN fuel density, fuel composition, and cladding alloy. All pins were irradiated at about 990 C in a thermal neutron environment to the design fuel burnup. An 85-percent dense UN fuel gave the best overall results in meeting the operational goals. The T-111 cladding on all specimens was embrittled, possibly by hydrogen in the case of the UN fuel and by uranium and oxygen in the case of the UO2 fuel. Tests with Cb-1Zr cladding indicate potential use of this cladding material. The UO2 fueled specimens met the operational goals of less than 1 percent cladding strain, but other factors make UO2 less attractive than low-density UN for the contemplated space power reactor use.

Bowles, K. J.

Synthesis and characterization of uranium trichloride in alkali-metal chloride media

Given a growing interest in uranium salts for pyrochemical processing of used fuel and uranium-fueled molten salt reactors, the synthesis of uranium trichloride in alkali-metal chloride media was investigated in a series of four experiments. Specifically, uranium metal powder and uranium hydride powder were prepared and separately blended with ammonium chloride and lithium chloride – potassium chloride eutectic in two runs, while the same powders were separately blended with ammonium chloride and sodium chloride in two additional runs. Each of the lithium chloride – potassium chloride containing blends was slowly heated to 923 K, while those containing sodium chloride were heated to 1123 K. During each heat up, the ammonium chloride sublimed into gaseous ammonia and hydrogen chloride, leading to the chlorination of uranium metal or uranium hydride and the formation of molten salt solutions of the respective chlorides. Experimental conditions were incorporated in the runs to promote formation of uranium trichloride over uranium tetrachloride in the respective media. Molten samples of each run product were taken and characterized via chemical analyses, diffractometry, and microscopy. The final products from each run were dark dense ingots of the respective salt systems with uranium concentrations ranging from 44 to 51 wt%. Chemical analyses and diffractometry identified the predominant presence of uranium trichloride in these systems; however, a possible minor presence of uranium tetrachloride could not be conclusively dismissed.

D Herrmann, Steven

Spatial Burnout in Water Reactors with Nonuniform Startup Distributions of Uranium and Boron

Spatial burnout calculations have been made of two types of water moderated cylindrical reactor using boron as a burnable poison to increase reactor life. Specific reactors studied were a version of the Submarine Advanced Reactor (sAR) and a supercritical water reactor (SCW) . Burnout characteristics such as reactivity excursion, neutron-flux and heat-generation distributions, and uranium and boron distributions have been determined for core lives corresponding to a burnup of approximately 7 kilograms of fully enriched uranium. All reactivity calculations have been based on the actual nonuniform distribution of absorbers existing during intervals of core life. Spatial burnout of uranium and boron and spatial build-up of fission products and equilibrium xenon have been- considered. Calculations were performed on the NACA nuclear reactor simulator using two-group diff'usion theory. The following reactor burnout characteristics have been demonstrated: 1. A significantly lower excursion in reactivity during core life may be obtained by nonuniform rather than uniform startup distribution of uranium. Results for SCW with uranium distributed to provide constant radial heat generation and a core life corresponding to a uranium burnup of 7 kilograms indicated a maximum excursion in reactivity of 2.5 percent. This compared to a maximum excursion of 4.2 percent obtained for the same core life when w'anium was uniformly distributed at startup. Boron was incorporated uniformly in these cores at startup. 2. It is possible to approach constant radial heat generation during the life of a cylindrical core by means of startup nonuniform radial and axial distributions of uranium and boron. Results for SCW with nonuniform radial distribution of uranium to provide constant radial heat generation at startup and with boron for longevity indicate relatively small departures from the initially constant radial heat generation distribution during core life. Results for SAR with a sinusoidal distribution rather than uniform axial distributions of boron indicate significant improvements in axial heat generation distribution during the greater part of core life. 3. Uranium investments for cylindrical reactors with nonuniform radial uranium distributions which provide constant radial heat generation per unit core volume are somewhat higher than for reactors with uniform uranium concentration at startup. On the other hand, uranium investments for reactors with axial boron distributions which approach constant axial heat generation are somewhat smaller than for reactors with uniform boron distributions at startup.

Fox, Thomas A.

Selective capture and recovery of uranium oxide colloids from aqueous soil suspensions using high gradient magnetic filtration

High Gradient Magnetic Filtration (HGMF) is a promising method for the selective capture and recovery of uranium oxide from surface soils. To date, however, magnetic filtration of uranium oxide has only been demonstrated at a proof-of-principle scale using relatively small filters (<5 cm 3 ) at low flowrates (<60 mL/min). Here, to explore the efficacy of magnetic filtration of uranium oxide at a larger scale, a newly designed HGMF apparatus that is more than an order of magnitude larger than our earlier filters (106 cm 3 ) was designed, fabricated, and tested at relatively high flowrates. Filtration experiments were performed using aqueous uranium oxide particle suspensions with Arizona Road Dust (ARD) as a soil simulant. At a flowrate of 125 mL/min, the apparatus’ uranium capture rate was exceptionally high (96 %), but selectivity was poor due to the high rate of capture for diamagnetic soil constituents (e.g., 77 % for silicon). All particles were captured at a lower rate when the flowrate was increased to 250 mL/min, but uranium selectivity was significantly increased due to the more substantial reduction in diamagnetic particle capture (i.e., capture rate of 77 % and 15 % for uranium and silicon, respectively). When backwashing the apparatus at the same flowrates used during filtration experiments, the rate of uranium recovery tended to be fairly low. Nevertheless, higher flowrates (1 L/min) and sonication were both shown to be highly effective methods of increasing uranium recovery. Magnetic field simulations were also performed to investigate potential optimizations to the design of the apparatus. These simulations showed that the intensity of the applied magnetic field could be increased by increasing the thickness of the steel magnetic housing. Additionally, stochastic trajectory simulations were performed to investigate the potential mechanisms of particle capture.

HGMF

In vitro toxicity assessment of uranium particulates on different human lung epithelial cell models

Inhalation of uranium aerosols produced via human activities such as mining can pose a threat to human respiratory systems. Uranium oxide particulates emit short-range alpha particles that elicit DNA and direct damage, beyond associated physiochemical heavy-metal toxicity, to internal epithelial tissues. The availability of reliable in vitro models to study radiation exposure can greatly enhance our ability to understand and combat the biological impacts of exposure. However, the toxicological effects of alpha emissions and/or the oxidation states of uranium particulates vary across different human lung epithelial cell models and have not been systematically compared. We have endeavored to address this limitation by comparing impacts in three different human lung cell models: primary human bronchial and tracheal epithelial cells, primary human small airway epithelial cells, and human adenocarcinoma alveolar basal epithelial cells. Other studies have mainly investigated the toxicity of depleted uranium. Here, we compared the exposure of uranium oxide particulates (U 3 O 8 and UO 3 ) of different enrichment states on the chosen cell systems. Each cell model was exposed to 0.1, 1, 10, 50, 100, and 500 µg/mL of depleted U 3 O 8 , highly-enriched U 3 O 8 , and natural UO 3 particulates for 24 hours in submerged monolayer cultures. We compared viability and superoxide dismutase activity results across cell lines and uranium enrichment/ oxidative states. The results showed that 1) the oxide state of the particulates affected cell viability, implying that uranium’s different oxidation states contribute to different toxicological responses, and 2) each cell model reacts differently when exposed to uranium oxides, which may provide insights into the mechanistic processes associated with the exposure of radiological particulates on different biological systems. For instance, increased uranium enrichment corresponds to increased toxicity for the primary cells, but not for the immortalized cells. Our study shows that a holistic approach that incorporates similarities between model systems and types of radionuclides is required to truly develop empirical solutions for radiation exposure.

59 BASIC BIOLOGICAL SCIENCES

Benchmark Gap Assessment for the Manufacturing of High-Assay Low-Enriched Uranium Fuels

This document develops basic critical conditions for spheres—moderated and unmoderated, as well as reflected and unreflected—in consideration of nuclear criticality safety of a potential fuel production facility producing high-assay low-enriched uranium (HALEU) fuel of several different types like tristructural-isotropic (TRISO), uranium metal and alloys, oxide and non-metallic forms. In addition to spherical arrangements, TRISO particle manufacturing process–specific equipment is modeled as it would be for the criticality safety analysis. The objective is to develop representative systems that can then be used for comparison with existing benchmarks. SCALE/TSUNAMI is used to assess the similarity index between these systems to assess validation gaps for possible fuel production applications of proposed advanced reactors. Several different fuel types were evaluated, including TRISO, uranium metal, uranium molybdenum, uranium zirconium, uranium dioxide, uranium nitride, uranium hydride, U-ZrH, and uranium chloride. This selection of fuel types covers a breadth of proposed reactor types, as well as intermediate steps in the production and fabrication of the fuel

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Thermodynamics of Liquid Uranium from Atomistic and Ab Initio Modeling

We present thermodynamic properties for liquid uranium obtained from classical molecular dynamics (MD) simulations and the first-principles theory. The coexisting phases method incorporated within MD modeling defines the melting temperature of uranium in good agreement with the experiment. The calculated melting enthalpy is in agreement with the experimental range. Classical MD simulations show that ionic contribution to the total specific heat of uranium does not depend on temperature. The density of states at the Fermi level, which is a crucial parameter in the determination of the electronic contribution to the total specific heat of liquid uranium, is calculated by ab initio all electron density functional theory (DFT) formalism applied to the atomic configurations generated by classical MD. The calculated specific heat of liquid uranium is compared with the previously calculated specific heat of solid γ-uranium at high temperatures. The liquid uranium cannot be supercooled below T sc ≈ 800 K or approximately about 645 K below the calculated melting point, although, the self-diffusion coefficient approaches zero at T D ≈ 700 K. Uranium metal can be supercooled about 1.5 times more than it can be overheated. The features of the temperature hysteresis are discussed.

36 MATERIALS SCIENCE

Delayed Neutron Temporal Signatures for Uranium Enrichment Measurement NA-241 SGTech (Final Report)

Nondestructive determination of uranium enrichment is a core capability for nuclear material accounting and control (NMAC) and safeguards verification measurements; however, traditional gamma spectroscopy-based techniques for enrichment measurement rely on significant assumptions of material composition and geometry, precluding their use in scenarios where a heterogeneous spatial distribution of enrichments is encountered. As an alternative, we are developing a technique to use delayed neutron temporal signatures for the measurement of uranium enrichment. Each uranium isotope has unique delayed neutron group yields, resulting in a unique delayed neutron decay time profile which can be analyzed to determine enrichment without the need for calibration sources. As part of this effort, we performed a series of measurement campaigns in which we used an active well coincidence counter (AWCC) retrofitted with commercial D-D and D-T generators to evaluate the operational characteristics of this method in response to a set of uranium enrichment and mass standards, as well as representative diversion scenarios in which either “concealed” enriched uranium is shielded by depleted uranium or declared enriched uranium is “hollowed out” and replaced with a central region of depleted uranium. A standard operating procedure and best practices were compiled to facilitate the use of delayed neutron-based enrichment measurements for international safeguards inspections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Application of Raman Spectroscopy to Determine Uranium Content in ADUN Solution

The work presented in this report is part of the ongoing efforts to address the nuclear material control and accounting needs for advanced reactor fuel fabrication facilities. This work was supported by the Materials Protection, Accounting, and Control Technologies (MPACT) program under the US Department of Energy Office of Nuclear Energy‘s Nuclear Fuel Cycle and Supply Chain program. The activities and engagements under the MPACT program are designed to support a robust US civilian nuclear energy enterprise. In the work described in this report, we supported MPACT objectives by developing measurement techniques that could be used for material accounting and process monitoring and by working with industry partners to identify existing gaps and areas for improvement. Oak Ridge National Laboratory has been working with commercial tristructural isotropic (TRISO) fuel fabricators such as Standard Nuclear to develop technology for rapid and cost-effective uranium content assessment. This work has focused on demonstrating advanced measurement techniques (e.g., Raman spectroscopy) that can be used for rapid, reliable, and cost-effective routine measurements of uranium content in feed solutions and liquid waste streams as well as for monitoring in-line process measurements and product streams. Specifically, this report explores techniques for accurately determining uranium content in acid-deficient uranyl nitrate (ADUN) solutions and detecting low uranium concentrations in ammonia solutions. Developing such measurement techniques will benefit TRISO fuel fabrication facilities, facilities involved in other parts of the fuel cycle that require online monitoring of aqueous solutions, and potentially molten salt fuel reactors. This work supports developing Raman spectroscopy procedures to determine uranium concentrations in ADUN solutions, which are used as feedstock in the sol–gel process for creating TRISO fuel. Some additional benefits of using Raman spectroscopy for uranium quantification in fabrication facilities include enabling online monitoring of the chemical process, which would provide near real-time feedback; eliminating the need for sample transfers, preparation, or dilution; providing nondestructive measurements; and user friendliness. In this fiscal year, FY25, we determined the identity of the unknown Raman band at approximately 853 cm−1 that was discovered in ADUN Raman spectra in FY24, created calibration curves and determined uranium concentrations of two ADUN solutions, and compared the Raman results to results obtained from inductively coupled plasma mass spectrometry and Davies–Gray titration. Furthermore, we have identified focus areas for experimentation in future fiscal years. A key result is that the accuracy of using Raman can provide accuracy comparable to destructive analysist techniques, With a well-developed calibration curve, using standards and a large number of samples (more than five samples), uncertainty on the order of 1%–3% is achievable. Given that the uncertainties achieved by Raman spectroscopy were on the order of the uncertainties achieved using ICP-MS, we conclude that with a well-developed procedure Raman spectroscopy can be used to determine uranium concentrations in ADUN solutions for NMC&A applications. The benefits of such an approach are that the time and effort will be less than that of comparable destructive analysis techniques, with approximately the same level of technical expertise. This will be attractive to operators of fuel fabrication facilities as it will lower costs and improve efficiencies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

High temperature UF6 RF plasma experiments applicable to uranium plasma core reactors

An investigation was conducted using a 1.2 MW RF induction heater facility to aid in developing the technology necessary for designing a self critical fissioning uranium plasma core reactor. Pure, high temperature uranium hexafluoride (UF6) was injected into an argon fluid mechanically confined, steady state, RF heated plasma while employing different exhaust systems and diagnostic techniques to simulate and investigate some potential characteristics of uranium plasma core nuclear reactors. The development of techniques and equipment for fluid mechanical confinement of RF heated uranium plasmas with a high density of uranium vapor within the plasma, while simultaneously minimizing deposition of uranium and uranium compounds on the test chamber peripheral wall, endwall surfaces, and primary exhaust ducts, is discussed. The material tests and handling techniques suitable for use with high temperature, high pressure, gaseous UF6 are described and the development of complementary diagnostic instrumentation and measurement techniques to characterize the uranium plasma, effluent exhaust gases, and residue deposited on the test chamber and exhaust system components is reported.

Roman, W. C.

Effects of a refractory metal protective barrier on uranium carbonitride ceramic–metallic composites exposed to a high temperature hydrogen environment

Uranium nitride has been under consideration at NASA and the Department of Energy for nuclear thermal propulsion applications intended for deep space exploration vehicles. It is critical to the success of the technology development that the behavior of the fuel system is properly characterized in operational environments. This body of work fabricated ceramic metal composites consisting of uranium ceramic fuel in a molybdenum and molybdenum–tungsten metal matrix, both with and without an exterior molybdenum barrier. Specimens were introduced to a high temperature hydrogen environment and characterized through x-ray diffraction, scanning electron microscopy, and energy dispersive spectroscopy to identify characteristic changes. A portion of the specimens was fabricated with a 1.27 mm thick molybdenum barrier in order to isolate the material from the hydrogen environment. Instability of the uranium nitride occurred as low as 2073 K, leading to aggressive instability approaching 2658 K. Carbon reactions with the metal matrix were observed as well as alloying between the uranium and metal matrix constituents. The liquid uranium resulting from the instability of the uranium nitride was observed to attack the grain boundaries of the refractory metal, resulting in the formation of a liquid uranium molybdenum eutectic melt. Specimens encased in a barrier experienced similar results. The authors conclude this is a significant challenge to applications of this cermet at these temperatures. Alternate configurations with resilient hermetic seals or lower temperature applications such as power reactors may have more success.

36 MATERIALS SCIENCE

A case study on the use of carbon sticky tabs for microbeam uranium isotope measurement with an emphasis on understanding the influence of subtle variations in substrate composition

In this paper we integrate laser induced breakdown spectroscopy (LIBS), large geometry secondary ion mass spectrometry (LG-SIMS), laser ablation—multi collector—inductively coupled plasma—mass spectrometry (LA-MC-ICP-MS), and trace elemental compositions obtained by bulk digestion from a suite of commercially available carbon sticky tabs to determine if subtle variations in the tab’s composition can be tied to shifts in the observed uranium isotopic composition of the IRMM-2020 standard relative to its ‘true’ value. The results suggest that, although clear differences exist in the relative abundances of carbon and hydrogen across the various carbon sticky tabs examined, as well as differences in their trace elemental and total uranium concentrations, these differences do not appear to influence the LG-SIMS or LA-MC-ICP-MS uranium isotope ratio measurements, or the appearance of the uranium mass spectrum scans. Instead, the quality (i.e., precision and accuracy) of the LG-SIMS and LA-MC-ICP-MS results are directly proportional to the observed signal intensity at the time of analysis. For the LG-SIMS measurements, there does appear to be a direct correlation between 235U1H hydride formation rates and vacuum conditions within the instrument’s analytical chamber. Furthermore, none of the carbon sticky tabs examined by LG-SIMS displayed evidence of elevated background uranium content. While a preliminary correlation was observed between the uranium isotope background signal during LA-MC-ICP-MS and the total uranium concentrations determined by isotope dilution, none of the tabs displayed a high enough analytical background to affect the isotope ratio measurements.

Zirakparvar, Alex [ORNL] (ORCID:0000000337797730)