Search NASASearch

SEARCH · Search NASA

Results for “urban heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

WRF-Comfort: simulating microscale variability in outdoor heat stress at the city scale with a mesoscale model

Abstract. Urban overheating and its ongoing exacerbation due to global warming and urban development lead to increased exposure to urban heat and increased thermal discomfort and heat stress. To quantify thermal stress, specific indices have been proposed that depend on air temperature, mean radiant temperature (MRT), wind speed, and relative humidity. While temperature and humidity vary on scales of hundreds of meters, MRT and wind speed are strongly affected by individual buildings and trees and vary on the meter scale. Therefore, most numerical thermal comfort studies apply microscale models to limited spatial domains (commonly representing urban neighborhoods with building blocks) with resolutions on the order of 1 m and a few hours of simulation. This prevents the analysis of the impact of city-scale adaptation and/or mitigation strategies on thermal stress and comfort. To solve this problem, we develop a methodology to estimate thermal stress indicators and their subgrid variability in mesoscale models – here applied to the multilayer urban canopy parameterization BEP-BEM within the Weather Research and Forecasting (WRF) model. The new scheme (consisting of three main steps) can readily assess intra-neighborhood-scale heat stress distributions across whole cities and for timescales of minutes to years. The first key component of the approach is the estimation of MRT in several locations within streets for different street orientations. Second, mean wind speed and its subgrid variability are downscaled as a function of the local urban morphology based on relations derived from a set of microscale LES and RANS simulations across a wide range of realistic and idealized urban morphologies. Lastly, we compute the distributions of two thermal stress indices for each grid square, combining all the subgrid values of MRT, wind speed, air temperature, and absolute humidity. From these distributions, we quantify the high and low tails of the heat stress distribution in each grid square across the city, representing the thermal diversity experienced in street canyons. In this contribution, we present the core methodology as well as simulation results for Madrid (Spain), which illustrate strong differences between heat stress indices and common heat metrics like air or surface temperature both across the city and over the diurnal cycle.

Geology

Ecohydrology of urban environments

Urban watersheds include a gradient of highly managed to unmanaged ecosystems that vary in vegetation cover, built and natural drainage systems, and impervious cover. A distinct difference to undeveloped ecosystems is the dominance of material and energy import and export, the disruption of natural catenae, the covariation of soils, terrain and canopy conditions. In this chapter, we discuss the distinct characteristics of urban ecohydrology compared to non-urban systems. We also investigate emergent principles of unmanaged watersheds that underscore the promotion of ecohydrological resilience, and the need to abstract and adapt these principles to support the goal-oriented restoration of impaired urban ecosystems.

42 ENGINEERING

Green Era Anaerobic Digester

Green Era Educational NFP constructed and commissioned the Green Era Renewable Energy & Urban Farming Campus in Chicago’s Auburn Gresham neighborhood. The project transformed a long-vacant brownfield site into a commercial-scale anaerobic digestion facility that converts food waste into renewable natural gas and nutrient-rich material for agricultural use. The facility can process up to 80,000 wet tons of food waste annually and supports approximately 15 permanent jobs while advancing food waste diversion, renewable energy production, nutrient recovery and community revitalization.

03 NATURAL GAS

Socio-Techno-Economic Feasibility of Deep Geothermal with EGS for Residential District Heating in the Northeastern United States

In this paper, we present socio-techno-economic simulation results for enhanced geothermal system (EGS) district heating systems in the northeastern United States. We applied the geospatial Distributed Geothermal Market Demand (dGeo) tool coupled with GEOPHIRES to evaluate the feasibility of geothermal deep direct-use, utilizing EGS reservoirs for providing residential heating with district heating systems. The results were combined with JEDI results to assess social impacts. Simulation results assuming doublet EGS reservoirs with target production temperature of 80 degrees C and newly constructed district heating systems indicate a wide range in system levelized cost of heat (LCOH) values ranging from ~$15/MMBtu to over $1,000/MMBtu, with most the attractive regions urban areas with high total thermal demand and high thermal demand density. We estimate about 60 GWth in potential installed capacity with LCOH values under $50/MMBtu and 100 GWth in potential capacity with LCOH values under $100/MMBtu, respectively.

15 GEOTHERMAL ENERGY

Fluorophilic Sigma(σ)‐Lock Self‐Healable Copolymers

Although F-Containing molecules and macromolecules are often used in molecular biology to increase the binding with Lewis acidic groups by introducing favorable C−F dipoles, there is virtually no experimental evidence and limited understanding of the nature of these interactions, especially their role in synthetic polymeric materials. These studies elucidate the molecular origin of inter- and intra-Chain interactions responsible for self-healing of F-Containing copolymers composed of pentafluorostyrene and n-butyl acrylate units (p(PFS/nBA). Guided by dynamic surface oscillating force (SOF) and spectroscopic measurements supported by molecular dynamics (MD) simulations, these studies show that the reformation of σ-σ orbitals in −C−F of PFS and CH 3 CH 2 − of nBA units enables the recovery of entropic energy via fluorophilic-σ-lock van der Waals forces when PFS/nBA molar ratios are ~50/50. The strength of these interactions determined experimentally for self-healable PFS/nBA compositions is in the order ~0.3 kcal/mol which primarily comes from fluorophilic-σ-lock (~70 %) contributions. These interactions are significantly diminished for non-self-healable counterparts. Strongly polarized −C−F σ orbitals create lateral dipolar forces enhancing the affinity towards −C−H orbitals, facilitating energetically favorable interactions. Entropic recovery driven by non-Covalent bonding offers a valuable tool in designing materials with unique functionalities, particularly self-healable batteries and energy storage devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Topographic effects on reflected acoustic waves from the OSIRIS-REx reentry observed from stratospheric balloons

During long-distance sound propagation in planetary atmospheres, acoustic waves may reflect off the air/surface interface one or more times. For low sound frequencies and flat interfaces, the incident and reflected wave tend to be nearly identical. However, this may not be the case when the downgoing acoustic wave encounters topography. Here, we describe a set of direct and reflected acoustic signals recorded on free-flying balloons during the hypersonic entry of the OSIRIS-REx sample return capsule (SRC). In two of the three cases presented here, an impulsive reflected arrival similar in form to the direct sonic boom of the SRC is observed, followed by a diffuse coda. In contrast, one of the floating stations lacked an impulsive reflection entirely, with only the coda present. We use full waveform modeling to show how reflection in the presence of complex topography can explain coda seen in all three examples as well as the lack of impulsive arrival on the third. Our results indicate that the complex signals often observed in long range acoustic propagation could be due, in part, to interactions with topography during transmission.

Lees, Jonathan M. [University of North Carolina, C

Fabrication of freeform potassium dihydrogen phosphate crystals by belt-on-wheel polishing for spatially tailored polarization control in high-power lasers

Large-aperture (>30 cm) optical components that provide spatially tailored control of the properties of a laser beam, such as phase, polarization, and amplitude, have been the focus of much research and development in recent years. Such optics can improve energy throughput and target implosion efficiency in high-power laser systems conducting inertial confinement fusion research. Here, a method is demonstrated for fabricating freeform surface topographies into the birefringent crystalline material, potassium dihydrogen phosphate (KDP). Belt-on-wheel polishing with an oil-based fluid, developed to mitigate the deliquescent properties of KDP, is used to deterministically polish a freeform topography into KDP, enabling the fabrication of a wave plate with spatially arbitrary retardance. Testing of the laser-induced damage threshold of belt-on-wheel polished KDP was conducted at a wavelength of 351 nm and a pulse duration of 1 ns. The results revealed that the polished surfaces are highly resistant to laser-induced damage, making them suitable for large-aperture, high-power laser applications.

Urban, Nathaniel D. [Univ. of Rochester, NY (Unite

IBPSA Project 2 BOPTEST: An update on the test cases available in the framework for testing advanced control strategies in buildings

Project 2 develops software infrastructure, test cases, and extensions for the Building Optimization Testing Framework (BOPTEST) to address the expanding needs of building and urban energy system controls through open international collaboration. This paper provides an overview of the new test cases available as of BOPTEST version 0.7.1. Each test case is developed using open-source Modelica libraries and Spawn of EnergyPlus, enabling the creation of high-fidelity building models that incorporate envelope dynamics, Heating Ventilation and Air Conditioning (HVAC) systems, and explicit control representations. Currently, eight test cases are available, with five additional cases under development. These test cases cover a wide range of climates, building types, and HVAC systems. This paper compiles and summarizes test case descriptions, cites original manuscripts that developed them for a more detailed description, and reports baseline control performance metrics. Furthermore, two example applications are presented: one illustrating different levels of control, from supervisory to low-level, and another demonstrating how Model Predictive Control (MPC) solutions must be adapted from continuous to integer to control some building actuators.

Zanetti, Ettore

RADAI: A Large-Scale Realistic Dataset for Radiation Detection Algorithm Development

Open, realistic datasets are essential for developing and benchmarking radiation detection algorithms, yet they remain scarce. The Radiological Anomaly Detection and Identification (RADAI) project was develop to create datasets that meet the training and testing needs for sophisticated radiation detection algorithms. The RADAI dataset is a large-scale synthetic resource that integrates high-fidelity Monte Carlo simulations with realistic urban scenarios to capture both background variability and source signatures. RADAI models construction-material NORM, people and vehicles, urban clutter, and dynamic environmental effects such as cosmic-ray and rain-induced transients, and they provide list-mode detector data with motion and response modeling suitable for algorithm training and evaluation. The RADAI project resulted in three publicly-released complementary datasets together with an online scoring portal for standardized performance assessment and an open software toolkit that supports data access, augmentation, model development, and evaluation. These resources enable reproducible comparisons across methods and promote rigorous studies at the scale required by contemporary machine learning. By grounding algorithm development in realistic, well-documented conditions, RADAI supports progress toward more robust detection, identification, and localization in complex urban environments.

Ghawaly, James M. [Division of Computer Science an

Cully Community Solar

This report summarizes the outcomes, accomplishments, challenges, and lessons learned from Verde’s Cully Community Solar project, funded by the U.S. Department of Energy’s Solar Energy Technologies Office. The project focused on advancing community solar development through engineering, permitting, interconnection, ecological site design, workforce development, and community engagement. During the project period, Verde and its partners successfully developed and commissioned a 1.25 MW ground-mounted community solar system while also advancing planning for additional community solar capacity and developing approaches that can inform future projects in complex urban environments.

14 SOLAR ENERGY

Plant Engineers Solar Energy Handbook: Southern California Region

Discussed in order after the introduction are solar components and systems (collectors, storage, service hot water systems, space heating with liquid and air systems, space cooling, heat pumps and controls); computer programs for system optimization; local solar and weather data; a description of buildings and plants in Southern California applying solar technology; current Federal and California solar legislation; standards, codes and performance testing information; a listing of manufacturers, distributors, and professional services available in Southern California region; and information access. Finally, solar design check lists for those engineers who wish to design their own systems. The program for the Solar Workshop for the Plant Engineer, March 30, 1978, Los Angeles, California is included.

14 SOLAR ENERGY

Ductless Heat Pump Program

The Verde Ductless Heat Pump (DHP) Program expanded access to high-efficiency electric heating and cooling technologies for households in priority communities within the Portland Metro area. Funded by the U.S. Department of Energy’s Building Technologies Office (DE-EE0010132), the program combined residential ductless heat pump deployment with community-based outreach, participant support, contractor partnerships, and system development to improve program delivery.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

High-resolution modeling of indoor radon exposure with uncertainty quantification in Utah

Indoor radon accounts for 37% of population-level exposure to ionizing radiation in the United States. However, radon metrics are typically reported at coarse spatial scales, potentially obscuring meaningful local variation. We developed a high-resolution modeling framework to estimate indoor radon concentrations across Utah while explicitly quantifying predictive uncertainty. A total of 19,497 residential radon measurements collected between 2006 and 2017 were combined with environmental and housing characteristics and analyzed using a geospatial neural network that accommodates spatial dependence and nonlinear associations. Predictions were generated on a uniform hexagonal grid at 0.73 km2 resolution (H3 level 8). Out-of-sample predictions aggregated to the H3 level 8 grid showed good agreement with observed concentrations (Pearson r=0.64), while household-level predictions exhibited more moderate agreement (r=0.45). The model produced well-calibrated uncertainty estimates, with 24.1% of held-out observations exceeding the predicted 75th-percentile threshold. Maps of predicted radon concentrations and the probability of exceeding the U.S. EPA action level of 148 Bq/m3 (4 pCi/L) revealed substantial fine-scale spatial heterogeneity that was not apparent in conventional coarse-resolution summaries, with greater local variability observed in densely monitored urban counties than in sparsely sampled regions. High-resolution radon models that explicitly quantify uncertainty provide a useful framework for characterizing the spatial distribution of indoor radon and identifying areas of elevated exceedance risk. These findings highlight the value of fine-scale monitoring data and uncertainty-aware modeling approaches for radon exposure assessment, environmental risk characterization, and radon-related health research.

Wu, Yunhan [ORNL] (ORCID:0000000178842994)

Bypass heat exchanger configuration to reroute core flow

A turbine engine assembly includes a heat exchanger that is in thermal communication with an exhaust gas flow. A bypass passage is provided that is configured to selectively route at least a portion of the exhaust gas flow around the heat exchanger in response to a predefined engine operating condition.

Terwilliger, Neil

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS