How Distributed Energy Resources Can Support Resilience in Utility Distribution Networks

The goal of this webinar is to engage with electric utilities in the Midwest, particularly small public utilities, to understand the industry's needs for science tools to plan for winter resilience in the future, designing tools that will benefit electric power resilience in all communities. Michigan Tech leads this project with partners from multiple academic, government, and industry groups and asked NLR to present on DERs and laboratory tools and resources.

24 POWER TRANSMISSION AND DISTRIBUTION

Powering Large Loads: Solutions Across Transmission, Utility, and Facility Scales

This report synthesizes current strategies for accommodating large load growth through a review of publicly available technical literature and media insights around the United States (U.S.). Solutions are organized across three implementation scales (transmission, utility, and facility) and categorized according to common implementation pathways (including structural expansion, operations and efficiency, upgrades, and planning and policy).

Valdez, Raquel Lynn [Sandia National Laboratories

A simplified di-homodyne transient grating spectroscopy system utilizing polarization

Here, a modification to the di-homodyne transient grating spectroscopy optical arrangement is presented that removes the need to individually align two spatially separated probe laser beams. This work details the novel application of a single probe beam that utilizes birefringent materials to produce two optically homodyned signals with a relative phase shift of π radians. This arrangement effectively simplifies the alignment to one probe beam and removes the relative phase shift ambiguity between each homodyned signal. Several example measurements for tungsten, titanium, molybdenum, and silicon are shown to illustrate the utility of the new optical system.

Simmonds, M. J. [Univ. of California, San Diego, C

Improvements in the utilization of calcium carbonate in promoting sustainability and environmental health

Calcium carbonate (CaCO 3 ) is an incredibly abundant mineral on Earth, with over 90% of it being found in the lithosphere. To address the CO 2 crisis and combat ocean acidification, it is essential to produce more CaCO 3 using various synthetic methods. Additionally, this approach can serve as a substitute for energy-intensive processes like cement production. By doing so, we have the potential to not only reverse the damage caused by climate change but also protect biological ecosystems and the overall environment. The key lies in maximizing the utilization of CaCO 3 in various human activities, paving the way for a more sustainable future for our planet.

Chemistry

Technology Assessment and Modelling of Three Terminal Tandem Solar Cells for In-Space Utilization

NASA seeks a sustained human presence on the lunar surface. High-efficiency and resilient energy systems are critical to supporting habitats, scientific outposts, and lunar surface operations. Photovoltaics have long been the backbone of space power systems, transitioning from silicon solar cells to multi-junction III-V solar cells, which now dominate state-of-the-art (SOA) technology. Multi-junction cells achieve high efficiency by layering semiconductors, each absorbing a specific portion of the solar spectrum. However, efficiency gains are increasingly constrained by device physics and manufacturing complexity. Additionally, higher-order junctions pose challenges for accurate modelling and performance characterization due to difficulties in replicating the AM0 spectrum.

solar cells

Utility Experience with Inverter Based Resource Impacts on Transmission Protection

High penetration of inverter-based resources (IBR) can adversely affect the transmission protection schemes in the area. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems because the existing system has been designed based on the fault current response of conventional rotating-machine-based generators. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. It includes a broad review of all challenges that system protection has experienced so far with high penetration of IBRs. Key issues have been identified based on a survey of different utility protection engineers. Finally, fault event recordings are shown to demonstrate some actual cases of mis-operations of relays near IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION

Utilities Perspective on Protection Challenges with High IBR Penetration

Utilities have seen rapid increase in Solar, Wind, and Battery Energy Storage Resources that interconnect to their electric system through Inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protect the inverter’s sensitive power electronics devices from damage, one source of which is overcurrent. This results in low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufactures and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This presentation identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of facing on one issue, we are looking broadly on all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspective from different utility SMEs via questionnaire, the presentation summarizes on gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION

POWER ELECTRONICS GRID TIED SYSTEM FINAL REPORT

Across the country, electric utilities are grappling with the persistent hurdles of integrating Distributed Energy Resources (DERs). Managing these assets safely and effectively is a complex endeavor, complicated by varying ownership structures, management philosophies, and the diversity of the technologies themselves. Consequently, the industry has seen a proliferation of bespoke system designs, control strategies, and communication frameworks—forcing utilities to spend significant time and resources developing one-off integration solutions. This project addressed these integration hurdles through a scalable demonstration of intelligent devices designed to coordinate and control diverse resources in low-voltage applications. This concept minimized the need for complex integration by transforming the separate DERs into a dispatchable virtual power plant (VPP) with integrated resiliency functions (called a Node). By collaborating with a utility partner, the project focused on developing rapidly implementable use cases that bridged the gap between theoretical control and real-world deployment

99 GENERAL AND MISCELLANEOUS

Coalition for Community-Supported Affordable Geothermal Energy Systems (C2SAGES)

The C2SAGES project evaluated the feasibility of a community geothermal system for the planned Windy Ridge affordable housing development in Hinesburg, Vermont. Led by GTI Energy with Vermont Gas Systems, LN Consulting, NREL, and Frontier Energy, the work assessed technical design, energy performance, costs, business models, community engagement, maintenance, workforce development, and permitting. The proposed system was designed to serve 100% of the development’s heating, cooling, and domestic hot water loads. Compared with a baseline using air-source heat pumps and natural gas water heating, the geothermal system was estimated to reduce HVAC and domestic hot water energy use by about 45% to 48%, lower operating and maintenance costs, and reduce 30-year life-cycle costs by 37% for Phase 1 and 10% for Phase 2. Technical testing and modeling indicated that the Windy Ridge site is suitable for a community-scale geothermal system. The project also developed borehole field layouts, piping concepts, pump house designs, controls, maintenance plans, and supporting engineering drawings. The business model analysis found that first cost, ownership structure, and customer affordability remain major deployment challenges. Utility-led maintenance and operation were viewed favorably, but traditional utility cost-recovery models may require subsidy or revised financing structures to be practical for affordable housing. Community engagement highlighted the need for clear public education, transparent financing, reliable long-term maintenance, trained technicians, and the potential to pair geothermal systems with weatherization. Overall, the report concludes that community geothermal is technically feasible and offers meaningful energy, emissions, and life-cycle cost benefits, but broader deployment will depend on workable financing models and workforce readiness.

15 GEOTHERMAL ENERGY

Scaling Real Estate Development Innovation With Emerging Local Area Developers

These case studies provide tangible examples within the development field that show how true innovation in real estate and property development hinges on shaping and optimizing diverse connections and relationships to create widely available, market-viable, and high-performance buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Electricity Rate Designs for Large Loads: Evolving Practices and Opportunities 2026 Update

Electricity demand from large-load customers such as data centers is projected to grow significantly in the near term. While these large loads play an important role in advancing technology innovation and economic growth in the United States, meeting their energy needs requires utilities and regulators to consider important operational and financial risks, such as insufficient energy supply or underutilized investments, that can impact all customers. This paper builds on similar research published in January 2025, providing an overview of how utilities and regulators are managing these risks through different tariffs, including rate structures and electric service agreements. Regulators, utilities, customers, and other stakeholders can use this paper as a foundation when discussing issues and sharing perspectives on developing or reviewing large-load tariffs.

24 POWER TRANSMISSION AND DISTRIBUTION

Energy 101 - Wind [Slides]

The Energy 101: Wind presentation, developed for the Energy Technology Innovation Partnership Project (ETIPP), provides an overview of wind energy. It covers fundamental concepts, technologies, considerations, case studies, and additional resources.

17 WIND ENERGY

Storing Affordability: Battery Storage as an Asset to Reduce Data Center Cost Shifts

This report examines how battery energy storage systems (BESS) can help utilities accommodate large load growth while protecting affordability for existing ratepayers. Rapid growth in electricity demand from artificial intelligence (AI) data centers is straining the U.S. grid. Furthermore, many new data centers are entering rural markets, which could offer economic benefits but may also pose implementation challenges for smaller utilities. At the same time, retail electricity prices are increasing faster than inflation, elevating customer affordability as a key challenge. While data centers have not been the primary driver of increases in residential prices to date, they have pushed wholesale energy and capacity prices higher in several markets. Fundamental utility cost-allocation principles show that data center growth can be rate-positive for existing customers only if new peak demand grows faster than the costs a utility must incur to serve it. Several factors, including a utility’s degree of wholesale market exposure, forecast uncertainty and stranded-asset risk, and tariff design can determine the outcome of load growth on retail rates. Energy storage can make several affordability contributions in the face of this landscape of uncertainty and market volatility, including deferral of higher-cost grid investments through improved utilization of existing assets and flexibility of new large loads, insulation from volatile wholesale prices through peak shaving, and reliability support to address grid risks stemming from the behavior of AI data center loads. Different potential BESS deployment pathways—utility-scale front-of-the-meter systems, aggregated small-scale storage installations, and data center-sited behind-the-meter storage—are compared against each other and against conventional capacity alternatives. This framework is intended as a conceptual resource to utilities, particularly smaller public utilities with rural service territories, who may be considering the role that energy storage can play in insulating existing ratepayers from data center cost shifts.

25 ENERGY STORAGE

Durability of ABC Team Wall Assemblies

This study evaluates the long-term hygrothermal durability of four advanced retrofit wall systems using a field test facility located in Hollywood, South Carolina, representative of a mixed-humid coastal climate (Zone 3). The research focuses on assessing the thermal and moisture performance of a baseline wall assembly retrofitted with (1) Tremco/Dryvit prefabricated panel systems (Revitalite and Fedderlite), (2) Reinforced Fiberglass Plastic (RFP) panels developed by Oak Ridge National Laboratory (ORNL), and (3) Vacuum Insulated Panels (VIP) integrated with EPS by Home Innovation Research Labs (HIRL) and ORNL. A baseline wall representing a typical uninsulated wood-frame construction was used for comparison.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Building Operation Model (Morpheus) for Dallas Fort Worth Airport (CRADA CRD-19-16301 Final Report)

The primary objective of this project was to leverage digital twin technology to enhance the design and operation of DFW Airport terminals and their associated energy systems. To achieve this, Morpheus, a building digital twin, was developed to guide improvements in airport operations, specifically targeting reductions in peak power demand and overall energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Technology & Design Innovations to Maximize the Reduction Effect on DCFC Unit Cost Economics (Max‐REDUCE)

With the high cost and reliability issues of DCFC infrastructure the project specifically addressed the needs of innovating on the AC to DC power conversion. We proved the integration of a new power module into existing charger units, and that theoretical educational work on single stage energy conversion is commercially viable, and a reduced cost compared to existing methods. Our A sample shown 3 PH 480VAC 60hz to 350VDC 8.5kW power transfer, and our software and simulation proved efficiency greater than 97% from 20kW to > 60kW, over the DC output voltage range 200 – 1200V. The project was stopped before we could implement B sample and execute full power testing, validation and integration into a demonstration charger (budget period 3).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI