Search NASA⌕ Search

SEARCH · Search NASA

Results for “vacuum swing adsorption (VSA)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Development and Verification of a Finite-Difference Model of the Sorbent-Based Atmosphere Revitalization System for the Crew Exploration

A vacuum-swing adsorption (VSA) process to remove metabolic water, metabolic carbon dioxide, and metabolic and equipment generated trace contaminant gases from the Crew Exploration Vehicle (CEV) atmosphere is being designed. For the CEV, the approach is taken that all metabolic water must be removed by the Sorbent-Based Atmosphere Revitalization System (SBAR), a technology approach that has not been used in previous spacecraft life support systems. To support the design of the SBAR, a Finite Difference computer model has been developed. In addition, examination of the competitive adsorption aspects of water and carbon dioxide on various sorbents is being investigated in order to both refine the computer simulation and gain understanding of the VSA process

Ritter, James↗

Development and Testing of a Sorbent-Based Atmosphere Revitalization System for the Crew Exploration Vehicle 2007/2008

The design of a Vacuum-Swing Adsorption (VSA) system to remove metabolic water and metabolic carbon dioxide from the Orion Crew Exploration Vehicle (CEV) atmosphere is presented. The approach for Orion is a VSA system that removes not only 100 percent of the metabolic CO2 from the atmosphere, but also 100% of the metabolic water as well, a technology approach that has not been used in previous spacecraft life support systems. The design and development of the Sorbent Based Atmosphere Regeneration (SBAR) system, including test articles, a facility test stand, and full-scale testing in late 2007 and early 2008 is discussed.

Knox, James C.↗

Development and Testing of a Sorbent-Based Atmosphere Revitalization System 2010/2011

Spacecraft being developed for future exploration missions incorporate Environmental Control and Life Support Systems (ECLSS) that limit weight, power, and volume thus requiring systems with higher levels of efficiency while maintaining high dependability and robustness. For air revitalization, an approach that meets those goals utilizes a regenerative Vacuum-Swing Adsorption (VSA) system that removes 100% of the CO2 from the cabin atmosphere as well as 100% of the water. A Sorbent Based Atmosphere Revitalization (SBAR) system is a VSA system that utilizes standard commercial adsorbents that have been proven effective and safe in spacecraft including Skylab and the International Space Station. The SBAR system is the subject of a development, test, and evaluation program that is being conducted at NASA s Marshall Space Flight Center. While previous testing had validated that the technology is a viable option, potential improvements to system design and operation were identified. Modifications of the full-scale SBAR test articles and adsorption cycles have been implemented and have shown significant performance gains resulting in a decrease in the consumables required for a mission as well as improved mission safety. Previous testing had utilized single bed test articles, during this period the test facility was enhanced to allow testing on the full 2-bed SBAR system. The test facility simulates a spacecraft ECLSS and allows testing of the SBAR system over the full range of operational conditions using mission simulations that assess the real-time performance of the SBAR system during scenarios that include the metabolic transients associated with extravehicular activity. Although future manned missions are currently being redefined, the atmosphere revitalization requirements for the spacecraft are expected to be quite similar to the Orion and the Altair vehicles and the SBAR test program addressed validation to the defined mission requirements as well as operation in other potential vehicle architectures. The development program, including test articles, the test facility, and tests and results through early 2011 is discussed.

Miller, Lee A.↗

Extremely large pressure swing adsorption processes for flue gas treatment

The current disclosure provides systems and methods for multiple beds undergoing a feed step at the same time with the same feed flow rate and multiple beds undergoing a light reflux step at the same time with the same light reflux flow rate to process a gas stream in a multi-bed, multi-unit vacuum swing adsorption (VSA) process using reasonably sized beds.

Ritter, James A.↗

Transformational Sorbent System for Post-Combustion Carbon Capture (Final Report)

As part of this DOE Contract (Transformational Sorbent System for Post-Combustion Carbon Capture, DE-FE0031734),TDA Research Inc. developed a transformational sorbent system for post combustion CO 2 capture process that captures more than 95% of CO 2 emissions from a coal fired power plant, recovering CO 2 at 95% purity with a cost of CO 2 capture significantly lower than with amine-based system (~$30 per tonne (MT) of CO 2 captured). TDA’s transformational sorbent system uses a novel, highly stable, high-capacity metal organic framework (MOF) based CO 2 sorbent in a new vacuum/concentration swing adsorption (VCSA) process that allows us to use high efficiency vacuum pumps with a low auxiliary load. A pulverized coal fired power plant equipped with TDA’s transformational sorbent system for post combustion CO 2 capture is expected to efficiently produce electricity with a low Cost of Electricity (COE) and capture greater than 95% of the CO 2 from the power plant exhaust.

01 COAL, LIGNITE, AND PEAT↗

Carbon Capture Pilot at Dry Fork Power Station (Final Technical Report)

The objective of this project was to design, seek necessary approvals, build and operate a large-scale pilot sorbent-based post combustion carbon capture system (CCS) at a coal fired power generation facility. TDA’s CCS uses a highly stable, low-cost, high-capacity physical adsorbent to effectively remove CO 2 via a combination vacuum and concentration swing adsorption (VCSA) process. The CCS is integrated with the power plant flue gas exhaust, which is rich in CO 2 (~13% vol. CO 2 ) and removes more than 90% of the plant’s overall carbon emissions.

01 COAL, LIGNITE, AND PEAT↗

Gradient Amine Sorbents for Low Vacuum Swing CO 2 Capture at Ambient Temperature

The growing concerns over CO 2 emissions have led to the development of various methods for CO 2 capture. CO 2 capture by amine-based sorbents has been achieved by temperature (thermal) swing adsorption (TSA) process, pressure swing adsorption (PSA) process, and temperature pressure or vacuuming swing adsorption (TPSA or TVSA) process for CO 2 capture. Amine sorbents for energy-efficient TSA, PSA, VSA, TPSA or TVSA CO 2 capture should possess a capability which allow adsorbed CO 2 to desorb and amine sorbent to be regenerated at low temperatures or low vacuums. Development of such amine sorbents would significantly decrease energy consumption and sorbent degradation during the regeneration step. The objective of this project is to develop a low vacuum swing adsorption (VSA) process for the capture of CO 2 from air. The focus is on the development of amine sorbent which allows CO 2 to adsorb in the form of weakly adsorbed CO 2 . The weakly adsorbed CO 2 species can be collected from the sorbent by applying a low vacuum at ambient temperature. Specifically, no heating (i.e., thermal energy) is needed for regeneration of amine sorbents. This novel sorbent allows VSA to be operated at ambient temperature without a significant energy demand. This process eliminates the energy-intensive heating and cooling process in temperature swing adsorption (TSA) process. Ambient temperature operation could prolong the lifetime of sorbent and minimize the maintenance cost. Extensive sorbent studies with in-situ infrared spectroscopy have revealed the modifications of conventional amine sorbents with additives can increase the fraction of weakly adsorbed CO 2 . The amine sorbents with loaded CO 2 can be regenerated in part by the following approaches: (i) mild heating to temperatures below 70 °C, (ii) flowing purging gas over modified amine sorbents at temperatures below 40 °C, (iii) vacuuming at pressure below 0.2 atm and temperatures below 40 °C. The performance of these modified amine sorbents has been tested in a 60 grams VSA unit at ambient temperatures. The results show that weakly adsorbed CO 2 which can be desorbed from modified amine sorbents with purging gas at 100 cc/min can also be evacuated at a vacuum of 1 psia at room temperature. A preliminary techno- economic analysis indicates the major cost of the VSA process with modified amine sorbents stems from the operation of vacuum pumps. Thus, developing an excellent sealing with minimum leakage for the VSA unit is the most critical task for further the development of this VSA technology.

36 MATERIALS SCIENCE↗

Performance study of charcoal-based radon reduction systems for ultraclean rare event detectors

The continuous emanation of radon due to trace amounts of uranium and thorium in detector materials introduces radon to the active detection volume of low-background rare event search detectors. 222 Rn produces a particularly problematic background in the physics region of interest by the "naked" beta decay of its 214 Pb daughter nucleus. While charcoal-based adsorption traps are expected to be effective for radon reduction in auxiliary circulation loops that service the warm components of current ton-scale detectors at slow flow rates (0.5-2 SLPM), radon reduction in the entire circulation loop at high flow rates $\mathcal{O}$(100s SLPM) is necessary to reach high sensitivity in future generation experiments. In this article we explore radon dynamics with a charcoal-based radon reduction system in the main circulation loop of time projection chamber detectors. Here, we find that even for perfect radon traps, circulation speeds of 2,000 SLPM are needed to reduce radon concentration in a 10 ton detector by 90%. This is faster by a factor of four than the highest circulation speeds currently achieved in dark matter detectors. We further find that the effectiveness of vacuum swing adsorption systems, which have been employed very successfully at reducing atmospheric radon levels in clean-rooms, is limited by the intrinsic radon activity of the charcoal adsorbent in ultra-low radon environments. Adsorbents with significantly lower intrinsic radon activity than in currently available activated charcoals would be necessary to build effective vacuum swing adsorption systems operated at room temperature for rare event search experiments. If such VSA systems are cooled to about 190 K, this requirement relaxes drastically.

47 OTHER INSTRUMENTATION↗