Search NASA⌕ Search

SEARCH · Search NASA

Results for “vacuum technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of advanced vacuum technologies for extending plasma pulse duration on EAST

Advanced vacuum technologies, including pumping, fueling and wall conditioning, have been successfully developed or upgraded to efficiently control the fuel and impurity particles to extend the plasma pulse duration in the experimental advanced superconducting tokamak (EAST). To improve the particle exhaust rate cryopumps with a 60% increase in pumping speed and ∼2 times increase in saturation capacity have been developed, and molecular pumps with a ∼30% increase in pumping speed have been upgraded. In order to monitor the molecular pump status while avoiding bearing faults and overload accidents, a fault detection system has been built which can offer an early warning to avoid more losses within the fusion device. A series of fueling technologies have been developed including gas injection system, supersonic molecular beam injector, pellet injector (PI), massive gas injector and shattered pellet injector, installed at the midplane and divertor positions at different ports to improve fueling uniformity and efficiency. Meanwhile, routine wall conditioning such as electric and hot N 2 baking, ion cyclotron wall conditioning and glow discharge cleaning have been successfully developed to remove the impurity particles from the inner component and materials. The low Z material wall coating and real-time powder injection during plasma discharge are also designed and applied to further improve particle control capability. Finally, by using these advanced vacuum related technologies, good vacuum (<2 × 10 −6 Pa) and wall conditions are realized, and the fuel and impurity particles can be effectively and stably controlled, which promotes the achievement of the record plasma of ∼1056 s pulse duration with the line-averaged electron density of 1.8 × 10 19 m −3 on EAST. They provide a very important reference for vacuum system design and operation for future fusion devices.

EAST↗

CRYOGENIC AND VACUUM TECHNOLOGICAL ASPECTS OF THE LOW-ENERGY ELECTROSTATIC CRYOGENIC STORAGE RING

The cryogenic and vacuum concepts for the electrostatic Cryogenic ion Storage Ring (CSR), under construction at the Max-Planck-Institut fuer Kernphysik in Heidelberg, is presented. The ring will operate in a broad temperature range from 2 to 300 K and is required to be bakeable up to 600 K. Extremely high vacuum and low temperatures are necessary to achieve long lifetimes of the molecular ions stored in the ring so that the ions will have enough time to cool by radiation to their vibrational and rotational ground states. To test cryogenic and vacuum technological aspects of the CSR, a prototype is being built and will be connected to the commercial cryogenic refrigerator recently installed, including a specialized 2-K connection system. The first results and the status of current work with the prototype are also presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of Electrodeposited CIGS Solar Cells: Cooperative Research and Development Final Report, CRADA Number CRD-09-357

At present, most PV materials are fabricated by vacuum technologies. Some of the many disadvantages of vacuum technology are complicated instrumentation, material waste, high cost of deposition per surface area, and instability of some compounds at the deposition temperature. Solution-based approaches for thin-film deposition on large areas are particularly desirable because of the low capital cost of the deposition equipment, relative simplicity of the processes, ease of doping, uniform deposition on a variety of substrates (including interior and exterior of tubes and various nonplanar devices), and potential compatibility with high-throughput (e.g., roll-to-roll) processing. Of the nonsilicon solar photovoltaic device modules that have been deployed to date, those based on the n-CdS/p-CdTe is a leading candidate. Two features in the optical characteristics of CdTe absorber are particularly attractive for photovoltaic conversion of sunlight; (a) its energy bandgap of 1.5 eV, which provides an optimal match with the solar spectrum and thus facilitates its efficient utilization and (b) the direct mode of the main optical transition which results in a large absorption coefficient and turn permits the use of thin layer (1-2 um) of active material. Thin films of CdTe required for these devices have been fabricated by a variety of methods (e.g., vapor transport deposition, vacuum deposition, screen printing and close-spaced sublimation). Electrodeposition is another candidate deserves more attention. This project will focus on delivering low-cost, high efficiency electrodeposited CdTe-based device.

14 SOLAR ENERGY↗

Brightness for Current NSLS-II In-Vacuum Undulator Technology in Different Lattice Scenarios

In this note the peak and effective magnetic field for In-Vacuum Undulators at NSLS-II is characterized by the well-known Halbach formula. This gives a reasonably good approximation of an IVU of any period and any magnetic gap within the range currently used at NSLS-II (≥ 18mm). This parameterization is then used in conjunction with known stay-clear requirements from the ring aperture definition as well as an absolute minimum of 4.5mm to calculate the maximum achievable brightness at any photon energy by scanning the parameters of period, gap, and length. This maximum achievable brightness is calculated for both devices centered at the lattice center as well as in a center-split configuration for the long and short straight sections of NSLS-II. In addition results are shown for a hypothetical single and center-split long straight section where the horizontal and vertical beta functions for a long straight have been modified to match at 2.5m. These are compared to a hypothetical canted double min-β configuration using the long straight section where the vertical beta function minimum is 1.6m and the horizontal as low as 3.2m. The latter case may provide significant benefit for medium and high photon energy beamlines seeking high brightness.

43 PARTICLE ACCELERATORS↗

EM-Enhanced HyPOR Loop for Fast Fusion Cycles

Vacuum pumps are the heart of a fusion energy facility – fusion power cannot be generated without them. Nevertheless, the vacuum technology needed to operate a viable fuel cycle for a compact fusion power plant does not exist. Commercial vacuum technology offers the best solution to this challenge, but a pump oil recycling and detritiation system is necessary. Conventional oil detritiation processes have only been developed to deal with legacy waste and are too slow and destructive to the oil. Further, post hoc detritiation strategies are intrinsically inefficient. Our approach is to rethink the challenge holistically by designing the pumping fluid and tritium extraction system in an integrated manner to achieve an innovative solution. By selecting an oil for the specific task of pumping tritium and then designing our catalytic system to selectively target the tritium-bearing functional groups, an effective detritiation system (hydrocarbon pump oil recycling, HyPOR, loop) for fusion power plants can be obtained. The project demonstrated a HyPOR loop process that can selectively remove heavier hydrogen isotopes from pump oil, reaching the target of 99.5 % removal, with an uptake of less than 0.01% of tritium throughput, while also purifying the oil of radiation-induced damage. The recycled oil retained its pumping characteristics over 7 recycles and gamma irradiation over 30 MGy. By meeting these targets, the project enable a reduction in pump operational costs from $\$$14.5M/year to $\$$103k/year (>140× reduction), reducing pump electric power consumption from 2.8 MW to 0.25 MW (>10× reduction), and reducing in-process tritium inventory from 2.03 kg to 0.48 kg (>4× reduction).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hydrogen Safety Training for Researchers

LLNL has been conducting hydrogen research for more than 50 years, starting with national security applications and continuing with hydrogen energy research. For many of these years, LLNL was designated as the pressure safety training facility for the whole DOE complex and other government institutions such as NASA. Many technicians and researchers visited LLNL to receive appropriate training on many aspects of pressure safety, including hydrogen technology, cryogenics, leak detection, and vacuum technology. The national security hydrogen and high-pressure research conducted at LLNL demanded unique testing facilities, and these were built with funding from DOE Defense Programs. These facilities include a high pressure laboratory equipped with 4 hydrogencompatible test cells, each rated for 80,000 psi, and 4 pounds of TNT equivalent stored energy. LLNL also has a high explosive test facility (Site 300) for high-energy experiments with many pounds of TNT equivalent and many kilograms of hydrogen. Experiments in Site 300 are typically conducted in outdoor firing tables and monitored from the safety of a bunker. The remote location of this facility protects employees and property from any hazard. These unique facilities and the expertise necessary to operate them are now being made available for hydrogen energy research through the development of training materials that may contribute to safe operation within the many institutions working for the hydrogen program.

08 HYDROGEN↗

APPLICATION OF VACUUM SALT DISTILLATION TECHNOLOGY FOR THE REMOVAL OF FLUORIDE

Vacuum distillation of chloride salts from plutonium oxide (PuO{sub 2}) and simulant PuO{sub 2} has been previously demonstrated at Department of Energy (DOE) sites using kilogram quantities of chloride salt. The apparatus for vacuum distillation contains a zone heated using a furnace and a zone actively cooled using either recirculated water or compressed air. During a vacuum distillation operation, a sample boat containing the feed material is placed into the apparatus while it is cool, and the system is sealed. The system is evacuated using a vacuum pump. Once a sufficient vacuum is attained, heating begins. Volatile salts distill from the heated zone to the cooled zone where they condense, leaving behind the non-volatile materials in the feed boat. The application of vacuum salt distillation (VSD) is of interest to the HB-Line Facility and the MOX Fuel Fabrication Facility (MFFF) at the Savannah River Site (SRS). Both facilities are involved in efforts to disposition excess fissile materials. Many of these materials contain chloride and fluoride salt concentrations which make them unsuitable for dissolution without prior removal of the chloride and fluoride salts. Between September 2009 and January 2011, the Savannah River National Laboratory (SRNL) and HB-Line designed, developed, tested, and successfully deployed a system for the distillation of chloride salts. Subsequent efforts are attempting to adapt the technology for the removal of fluoride. Fluoride salts of interest are less-volatile than the corresponding chloride salts. Consequently, an alternate approach is required for the removal of fluoride without significantly increasing the operating temperature. HB-Line Engineering requested SRNL to evaluate and demonstrate the feasibility of an alternate approach using both non-radioactive simulants and plutonium-bearing materials. Whereas the earlier developments targeted the removal of sodium chloride (NaCl) and potassium chloride (KCl), the current activities are concerned with the removal of the halide ions associated with plutonium trifluoride (PuF{sub 3}), plutonium tetrafluoride (PuF{sub 4}), calcium fluoride (CaF{sub 2}), and calcium chloride (CaCl{sub 2}). This report discusses non-radioactive testing of small-scale and pilot-scale systems and radioactive testing of a small-scale system. Experiments focused on demonstrating the chemistry for halide removal and addressing the primary engineering questions associated with a change in the process chemistry.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Heavy-ion induced desorption of a TiZrV coated vacuum chamber bombarded with 5 MeV/u Ar{sup 8+} beam at grazing incidence

TiZrV nonevaporable getter (NEG) coated vacuum chambers is a new vacuum technology which is already used in many particle accelerators worldwide. This coating is also of interest for heavy-ion accelerator vacuum chambers. Heavy-ion desorption yields from an activated as well as a CO saturated NEG coated tube have been measured with 5 MeV/u Ar{sup 8+} beam. The sticking probability of the NEG film was obtained by using the partial pressure ratios on two sides of the NEG coated tube. These ratios were compared to results of modeling of the experimental setup with test particle Monte Carlo and angular coefficient methods. The partial pressures inside the saturated NEG coated tube bombarded with heavy ions were up to 20 times larger than those inside the activated one. However, the partial pressure of methane remained the same. The value of the total desorption yield from the activated NEG coated tube is 2600 molecules/ion. The desorption yields after saturation for CH{sub 4}, H{sub 2}, and CO{sub 2} were found to be very close to the yields measured after the activation, while CO increased by up to a factor of 5. The total desorption yield for the saturated tube is up to 7000 molecules/ion. The large value of the desorption yield of the activated NEG coated tube, an order of magnitude higher than the desorption yield from a stainless steel tube at normal incident angle, could be explained by the grazing incident angle.

36 MATERIALS SCIENCE↗

Effect of surface polishing and vacuum firing on electron stimulated desorption from 316LN stainless steel

The reduction of thermal outgassing from stainless steel by surface polishing or vacuum firing is well-known in vacuum technology, and the consequent use of both techniques allows an even further reduction of outgassing. The aim of this study was to identify the effectiveness of surface polishing and vacuum firing for reducing electron-stimulated desorption (ESD) from 316LN stainless steel, which is a frequently used material for particle accelerator vacuum chambers and components. It was found that, unlike for thermal outgassing, surface polishing does not reduce the ESD yield and may even increase it, while vacuum firing of nonpolished sample reduces only the H{sub 2} ESD yield by a factor 2.

36 MATERIALS SCIENCE↗

Negative Ion Drift Time Projection Chamber Development for High-Resolution Tracking

Gas Time Projection Chambers (TPCs) are used extensively in High Energy Physics. Modern micro-pattern gaseous detectors (MPGDs) have made it feasible to construct large-volume TPCs with high readout granularity, so that ionization can be imaged with spatial resolution of order 100 μm or better. A challenge with large TPCs is preserving the track geometry over large drift distances. The reduced diffusion offered by negative ion drift (NID) has long been considered a possible means to scaling up TPCs at reduced cost, but NID has up to now required toxic and often flammable multi-component gas mixtures. A number of recent breakthroughs in the field have, however, led to a resurgence of interest in NID gas TPCs: First, it was found that multiple charge carriers in NID can be utilized to measure the absolute position of primary ionization in the drift direction, yielding a powerful new handle on backgrounds, at zero additional cost. Second, work by one of the PIs has revealed SF6 gas to be a non-toxic, non-flammable, NID gas with suitable minority charge carriers present. Third, preliminary work by the PIs suggests that multiple MPGD technologies work well with SF6. This opens the door to a new generation of large, high-resolution, low-background, low-cost gas TPCs. In this work we will investigate MPGD charge multiplication and charge readout in NID TPCs with SF6 gas. The objectives are to quantify the improvement over electron drift TPCs, and to identify the optimal MPGD types, operational parameters, electronics, and vacuum technologies for future low-background experiments. We will measure low-level detector performance parameters such as gain, gain resolution, and spatial resolution, as well as the resulting higher-level performance parameters such nuclear recoil identification efficiency, gamma-ray background rejection, track angle resolution and recoil energy resolution. The proposed work also includes investigation of acrylic vacuum vessels and collaboration on dedicated charge readout chips, both required for next-generation NID MPGD TPCs. MGPD NID TPCs may prove transformative for applications which require both high readout granularity and large detector volumes, such as the reconstruction of nuclear recoils in the context of large-scale directional dark matter searches, measurements of coherent neutrino-nucleus scattering, and directional neutron detection. While the proposed work is focused on nuclear recoils, the lessons learned will be widely applicable to gas TPCs in HEP, and hence have broad impact.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A passively pumped vacuum package sustaining cold atoms for more than 200 days

Compact cold-atom sensors depend on vacuum technology. One of the major limitations to miniaturizing these sensors is the active pumps—typically ion pumps—that are required to sustain the low pressure needed for laser cooling. Although passively pumped chambers have been proposed as a solution to this problem, technical challenges have prevented successful operation at the levels needed for cold-atom experiments. The authors present the first demonstration of a vacuum package successfully independent of ion pumps for more than a week; their vacuum package is capable of sustaining a cloud of cold atoms in a magneto-optical trap (MOT) for greater than 200 days using only non-evaporable getters and a rubidium dispenser. Measurements of the MOT lifetime indicate that the package maintains a pressure of better than 2×10−7 Torr. This result will significantly enable the development of compact atomic sensors, including those sensitive to magnetic fields, where the absence of an ion pump will be advantageous.

Little, Bethany J. (ORCID:0000000332892798)↗

Studies of Heterogeneously Catalyzed Liquid-Phase Alcohol Oxidation on Platinum bySum-frequency Generation Vibrational Spectroscopy and Reaction Rate Measurements

Compared to many branches of chemistry, the molecular level study of catalytically active surfaces is young. Only with the invention of ultrahigh vacuum technology in the past half century has it been possible to carry out experiments that yield useful molecular information about the reactive occurrences at a surface. The reason is two-fold: low pressure is necessary to keep a surface clean for an amount of time long enough to perform an experiment, and most atomic scale techniques that are surface speci c (x-ray photoelectron spectroscopy, electron energy loss spectroscopy, Auger electron spectroscopy, etc.) cannot be used at ambient pressures, because electrons, which act as chemical probes in these techniques, are easily scattered by molecules. Sum-frequency generation (SFG) vibrational spectroscopy is one technique that can provide molecular level information from the surface without the necessity for high vacuum. Since the advent of SFG as a surface spectroscopic tool it has proved its worth in the studies of surface catalyzed reactions in the gas phase, with numerous reactions in the gas phase having been investigated on a multitude of surfaces. However, in situ SFG characterization of catalysis at the solid-liquid interface has yet to be thoroughly pursued despite the broad interest in the use of heterogeneous catalysts in the liquid phase as replacements for homogeneous counterparts. This work describes an attempt to move in that direction, applying SFG to study the solid-liquid interface under conditions of catalytic alcohol oxidation on platinum.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A coupled ordinates method for solution acceleration of rarefied gas dynamics simulations

Non-equilibrium rarefied flows are frequently encountered in a wide range of applications, including atmospheric re-entry vehicles, vacuum technology, and microscale devices. Rarefied flows at the microscale can be effectively modeled using the ellipsoidal statistical Bhatnagar–Gross–Krook (ESBGK) form of the Boltzmann kinetic equation. Numerical solutions of these equations are often based on the finite volume method (FVM) in physical space and the discrete ordinates method in velocity space. However, existing solvers use a sequential solution procedure wherein the velocity distribution functions are implicitly coupled in physical space, but are solved sequentially in velocity space. This leads to explicit coupling of the distribution function values in velocity space and slows down convergence in systems with low Knudsen numbers. Furthermore, this also makes it difficult to solve multiscale problems or problems in which there is a large range of Knudsen numbers. In this paper, we extend the coupled ordinates method (COMET), previously developed to study participating radiative heat transfer, to solve the ESBGK equations. In this method, at each cell in the physical domain, distribution function values for all velocity ordinates are solved simultaneously. This coupled solution is used as a relaxation sweep in a geometric multigrid method in the spatial domain. Enhancements to COMET to account for the non-linearity of the ESBGK equations, as well as the coupled implementation of boundary conditions, are presented. The methodology works well with arbitrary convex polyhedral meshes, and is shown to give significantly faster solutions than the conventional sequential solution procedure. Acceleration factors of 5–9 are obtained for low to moderate Knudsen numbers on single processor platforms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Water desorption from rapidly-heated metal oxide surfaces—first principles, molecular dynamics, and the Temkin isotherm

Quantitative understanding and control of water and impurity desorption from steel surfaces are crucial for high-voltage, pulsed power, vacuum technology, catalysis, and environmental applications. We apply a suite of modeling techniques, ranging from electronic density functional theory, to classical molecular dynamics (MD) and grand canonical Monte Carlo (GCMC) methods to study the thermodynamics and kinetics of fast water desorption from different surfaces of hematite Fe 2 O 3 and Cr 2 O 3 . Water binding energies on chromium oxide are found to be higher than iron oxide at zero temperature. MD simulations are conducted on Fe 2 O 3 surfaces using thermodynamically consistent initial water inventory deduced with GCMC. The resulting time- and temperature-dependent desorption profiles on the Fe 2 O 3 ($0001$) surfaces show multi-water cooperative behavior which cannot be deduced from zero temperature predictions, but which are in reasonable agreement with simple Temkin isotherm model estimates if finite temperature effects are incorporated into the Temkin binding energy parameter. Finally, qualitatively different desorption behaviors associated with the ($0001$) and ($1\bar{1}02$) facets are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Vacuum Chamber Design of NSLS-II Storage Ring

National Synchrotron Light Source II (NSLS II) will be a 3-GeV, 792-meter circumference, 3rd generation synchrotron radiation facility, with ultra low emittance and extremely high brightness. the storage ring has 30 Double-Bend-Achromatic (DBA) cells. in each cell, there are five magnets and chamber girders, and one straight section for insertion devices or Radio Frequency (RF) cavities or injection. Most vacuum chambers are made from extruded aluminum with two different cross sections: one fitted in the dipole magnets, and the other surrounded by multipole magnets. They discuss the layout of the DBA cells, the detailed design of the cell's vacuum chambers, the mounting of the Beam-Position-Monitor (BPM) buttons, discrete absorbers, lumped pumps and the distributed Non-Evaporable Getter (NEG) strips, and describe the fabrication and testing of these prototype cell chambers. The account also details the development of the chamber bakeout process, the NEG stri's supports, and the RF shielded bellows.

43 PARTICLE ACCELERATORS↗

APPLICATION OF VACUUM SALT DISTILLATION TECHNOLOGY FOR THE REMOVAL OF FLUORIDE AND CHLORIDE FROM LEGACY FISSILE MATERIALS

Between September 2009 and January 2011, the Savannah River National Laboratory (SRNL) and the Savannah River Site (SRS) HB-Line Facility designed, developed, tested, and successfully deployed a production-scale system for the distillation of sodium chloride (NaCl) and potassium chloride (KCl) from plutonium oxide (PuO{sub 2}). Subsequent efforts adapted the vacuum salt distillation (VSD) technology for the removal of chloride and fluoride from less-volatile halide salts at the same process temperature and vacuum. Calcium chloride (CaCl{sub 2}), calcium fluoride (CaF{sub 2}), and plutonium fluoride (PuF{sub 3}) were of particular concern. To enable the use of the same operating conditions for the distillation process, SRNL employed in situ exchange reactions to convert the less-volatile halide salts to compounds that facilitated the distillation of halide without removal of plutonium. SRNL demonstrated the removal of halide from CaCl{sub 2}, CaF{sub 2} and PuF{sub 3} below 1000 C using VSD technology.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗