Search NASA⌕ Search

SEARCH · Search NASA

Results for “value analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Grid Value Analysis of Medium-Voltage Back-to-Back Converter on DER Hosting Enhancement

This paper presents an analysis of the value that can be realized by medium-voltage back-to-back (MVB2B) converters in terms of the increased utilization rate of distributed energy resources (DERs) and the improvement in operational conditions. A systematic, transferrable, and scalable methodology has been designed to analyze and quantify the increased DER value from three perspectives: 1) curtailment reduction of the DER generation, 2) size reduction of the energy storage needed to otherwise realize DER hosting levels, and 3) hosting capacity improvement of the DERs compared to the base distribution circuit capability. In the case study, the proposed methodology is applied to two utility distribution systems for analysis and quantification of the grid value of the MVB2B converter, installed in the distribution circuit, and provided to the solar photovoltaic (PV) DERs. Here, the analysis results demonstrate that the MVB2B converter can deliver significant value to the PV hosting enhancement of two adjacent distribution systems when they are connected by the MVB2B converter. Based on this case study, this paper analyzes and summarizes the approximate realized grid value of the MVB2B converter for distribution systems dominated by different shares of customer classes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Vehicle Residual Value Analysis by Powertrain Type and Impacts on Total Cost of Ownership

Vehicle depreciation is a key factor in determining the total cost of vehicle ownership and consumer purchase behavior. This report examines how light-duty-vehicle residual values have evolved over time for conventional and advanced vehicle technologies, accounting for important factors such as market segment, size class, and country of assembly. Advancements in electric vehicle technology have led to plug-in vehicles exhibiting depreciation curves similar to those of conventional vehicles. This report compares two methods for determining depreciation trends (snapshot method and time-series method) in order to identify potential impacts on calculating vehicle total cost of ownership given differing data availability.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Vehicle Residual Value Analysis by Powertrain Type and Impacts on Total Cost of Ownership

Vehicle depreciation is a key factor in determining the total cost of vehicle ownership and consumer purchase behavior. This report examines how light-duty-vehicle residual values have evolved over time for conventional and advanced vehicle technologies, accounting for important factors such as market segment, size class, and country of assembly. Although plug-in vehicles have historically depreciated faster than conventional vehicles, advancements in electric vehicle technology have led to plug-in vehicles exhibiting depreciation curves similar to those of conventional vehicles. This report compares two methods for determining depreciation trends (snapshot method and time-series method) in order to identify potential impacts on calculating vehicle total cost of ownership given differing data availability.

33 ADVANCED PROPULSION SYSTEMS↗

A Climatology and Extreme Value Analysis of Large Hail in China

In this paper, hail size records are analyzed at 2254 stations in China and a hail size climatology is developed based on gridded hail observations for the period 1960–2015. It is found that the annual percentiles of hail size records changed sharply and national-wide after 1980, therefore two periods, 1960–79 and 1980–2015, are studied. There are some similarities between the two periods in terms of the characteristics of hail size such as the spatial distribution patterns of mean annual maximum hail size and occurrence week of annual maximum hail size. The 1980–2015 period had higher observation density than the 1960–79 period, but showed smaller mean annual maximum hail size, especially in northern China. In the majority of grid boxes, the annual maximum hail size experienced a decreasing trend during the 1980–2015 period. A Gumbel extreme value model is fitted to each grid box to estimate the return periods of maximum hail size. The scale and location parameter of the fitted Gumbel distributions are higher in eastern China than in western China, thereby reflecting a greater likelihood of large hail in eastern China. In southern China, the maximum hail size exceeds 127 mm for a 10-yr return period, whereas in northern China maximum hail size exceeds this threshold for a 50-yr return period. Furthermore, the Gumbel model is found to potentially underestimate the maximum hail size for certain return periods, but provides a more informed picture of the spatial distribution of extreme hail size and the regional differences.

54 ENVIRONMENTAL SCIENCES↗

Grid Value Analysis of Geothermal Systems for End-Use Applications

Fuel based end-uses for residential, commercial, and industrial consumers require a technology change to achieve economy-wide decarbonization. Space heating accounts for 42% of residential and 32% of commercial energy demand, much of which is currently met through carbon emitting fuels. Industrial energy use is heavily fuel based with electricity currently representing 13% of energy demand. Geothermal heat pumps (GHPs) and geothermal direct use can eliminate the need for CO2 emitting and simultaneously allow for more efficient electrification of end uses. Past work has assessed the impact on total energy costs and generation investments but did not identify specific grid services benefited. Energy usage in residential and commercial structures was assessed by leveraging data from ComStock and ResStock models. These models utilize housing attributes, occupancy patterns, weather data, and sophisticated energy simulations to generate hourly load profiles for individual buildings identified by unique IDs associated with their locations. Industrial sector energy use was evaluated using information from the Manufacturing Energy Consumption Survey (MECS) as well as plant utilization data from the US Census to estimate hourly plant operations. The change in end-use demand for electricity, natural gas, and other fuels was calculated for different technologies that could meet this need. Using the ReEDS capacity expansion model, we produce regional price profiles that capture the grid benefit associated with the amount and timing of energy shifts in the power system from the adoption of geothermal systems relative to other technologies that could meet space heating, space cooling, and process heat requirements. We find that geothermal systems for meeting end-use demand add value to the energy system. In buildings where geothermal systems increase grid costs, these values are offset by reduced fuel costs and benefits to externalities, including emissions and health impacts.

decarbonization↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microgrid Tiered Circuits Effects for a Planned Housing Community in Puerto Rico

Puerto Rico faced a double strike from hurricanes Irma and Maria in 2017. The resulting damage required a comprehensive rebuild of electric infrastructure. There are plans and pilot projects to rebuild with microgrids to increase resilience. This paper provides a techno-economic analysis technique and case study of a potential future community in Puerto Rico that combines probabilistic microgrid design analysis with tiered circuits in building energy modeling. Tiered circuits in buildings allow electric load reduction via remote disconnection of non-critical circuits during an emergency. When coupled to a microgrid, tiered circuitry can reduce the chances of a microgrid's storage and generation resources being depleted. The analysis technique is applied to show 1) Approximate cost savings due to a tiered circuit structure and 2) Approximate cost savings gained by simultaneously considering resilience and sustainability constraints in the microgrid optimization. The analysis technique uses a resistive capacitive thermal model with load profiles for four tiers (tier 1-3 and non-critical loads). Three analyses were conducted using: 1) open-source software called Tiered Energy in Buildings and 2) the Microgrid Design Toolkit. For a fossil fuel based microgrid 30% of the total microgrid costs of 1.18 million USD were calculated where the non-tiered case keeps all loads 99.9% available and the tiered case keeps tier 1 at 99.9%, tier 2 at 95%, tier 3 at 80% availability, with no requirement on non-critical loads. The same comparison for a sustainable microgrid showed 8% cost savings on a 5.10 million USD microgrid due to tiered circuits. The results also showed 6-7% cost savings when our analysis technique optimizes sustainability and resilience simultaneously in comparison to doing microgrid resilience analysis and renewables net present value analysis independently. Though highly specific to our case study, similar assessments using our analysis technique can elucidate value of tiered circuits and simultaneous consideration of sustainability and resilience in other locations.

building energy modeling↗

Nova Analysis: Holistically Valuing the Contributions of Residential Efficiency, Solar and Storage

Policies to address climate change and grid modernization, in combination with cost reductions and technological advancements in energy efficiency (EE) and distributed energy resources (DER), are driving rapid deployment of building electrification and energy efficiency retrofits, rooftop solar photovoltaics (PV), smart thermostats, smart water heaters, and battery energy storage. In residential buildings, there are multiple stakeholders (occupant, utility, aggregator, society at large) that are each focused on different value streams. This project uses a suite of metrics intended to all of these value streams to try to holistically analyze the benefits that come from solar, storage, and energy efficiency. To demonstrate the value of these metrics, a semi annual study was performed simulating hundreds of homes across the U.S. under several different upgrade scenarios.

14 SOLAR ENERGY↗

Extreme flood return levels in a U.S. mid-Atlantic estuary using 40-year fluvial-coastal model simulations

Using an integrated watershed-coastal modeling framework, we conducted long-term historical simulations (1980-2019) of fluvial and coastal flooding in the Delaware Bay and River, a vulnerable estuarine system in the U.S., at high spatial resolutions. By applying process-based models, we generated physically consistent and spatially detailed estimates of estuarine, riverine, and surge-driven extreme water level compared to previous studies that used field data only. We then evaluated changes in the magnitude of flood events using the 40-year simulations and detrended Floodwater Depth values with stationary extreme value analysis. Our detailed assessment of spatial-varying extreme values revealed how different flood-generation mechanisms can dominate various zones in the estuary. The datasets produced through this work will be valuable for long-term flood hazard mitigation planning in coastal communities in the Delaware Bay and River region. Additionally, this work will serve as a benchmark for other coastal flood hazard modeling communities worldwide, aiding them in systematically modeling long-term and continuous extreme flood events.

Coastal and Riverine Flooding↗

Dataset for 'Ombadi et al. (2023). A warming-induced reduction in snow fraction amplifies rainfall extremes, Nature'

This package contains the main codes, sample input data and main result files to reproduce the analysis and results presented in the article: “Ombadi et al. (2023), A warming-induced reduction in snow fraction amplifies rainfall extremes, Nature”. The folder consists of the following: (1) “Raw data”: a folder that contains sample input data which is used in some of the codes for demonstration purposes. It also contains data that was not pre-processed such as Elevation data; (2) “Results”: this folder contains files of the main results presented in the paper including: “Annual-Max-Series”, “Change-rainfall-extremes”, “Change-snow-fraction”, “Warming levels_By scenario_model_year” and “Masks”. Description of these folders is detailed in the "Readme.rtf" file; (3) Python jupyter notebooks (Extract_Annual Max Series (AMS).ipynb, Elevation-dependent amplification of rainfall extremes.ipynb, Sensitivity_to_global_warming.ipynb) demonstrate the main steps of analysis. Further description of those notebooks is provided in the "Readme.rtf" file; (4) R code for extreme value analysis (Extreme_Value_Analysis.R). The sample and pre-processed dataset in "Raw data" is obtained from publicly available repositories of CMIP6 and ERA5 datasets; see Methods for more detail. This research was supported by Office of Science, Office of Biological and Environmental Research of the US Department of Energy under contract no. DE-AC02-05CH11231 for the CASCADE Scientific Focus (funded by the Regional and Global Model Analysis Program area within the Earth and Environmental Systems Modeling Program) and the iNAIADS Early Career Research Project (funded by the Environmental Systems Science program).

54 ENVIRONMENTAL SCIENCES↗

Quantifying Rooftop Solar Benefits: A State-Level Value of Solar Analysis for India

Analyses that quantify the costs and benefits associated with rooftop solar (RTS) adoption and operation can inform decision-makers in the development and evaluation of RTS policies. One such analysis is a Value of Solar (VOS) study, which quantifies select costs and benefits surrounding RTS based on the electricity system context. These studies can drive changes to existing policies towards fairer, more cost-reflective RTS compensation or alternatively can provide confidence for the decision-maker to stay the course and largely maintain existing policies. This report provides a VOS analysis for two states in India: Gujarat and Jharkhand and provides details related to the methodology and key findings.

14 SOLAR ENERGY↗

Load Deflection Data (LDDATA)

The current data set is load deflection data (Stress vs strain for compression stress and stress vs elongation for tension stress) from a material test. The goal of the test was to characterize this rubber-like material by looking at different variables: sample creation process, anisotropy, temperature, etc. The data will be used with the Texas A&M Online Research Experience for Undergraduates (O-REU) program. This program is joint with LANL. The student is not an official LANL student so they will not be able to access data and documents on the yellow. The load deflection data set is unclassified and will be sent to the student for analysis. Analysis will include curve fitting, scalar value analysis (stiffness, toughness, etc.) and analysis of variance to determine what variables statistically affect the response while correcting for covariates (temperature soak time and humidity). Data will be stored as Matlab structs and as HDF5 files. Same data, different formats.

36 MATERIALS SCIENCE↗