Development of a Connected Vehicle Dynamic Freeway Variable Speed Controller
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Utility service providers are often challenged with the synchronization of thermostatically controlled loads. Load synchronization, as a result of naturally occurring and demand-response events, has the potential to damage power distribution equipment. Because thermostatically controlled loads constitute most of the power consumed by the grid at any given time, the proper control of such devices can lead to significant energy savings and improved grid stability. The contribution of this paper is the development of an optimal control algorithm for commonly used variable speed heat pumps. By means of selective peer-to-peer communication, our control architecture allows for the regulation of home temperatures while simultaneously minimizing aggregate power consumption, and aggregate load volatility. An optimal centralized controller is also explored and compared against its decentralized counterpart.
Electric Vehicle (EV) charging has been a significant barrier to the widespread use of EVs. Traditional EV charging methods depend on cables, and there are concerns about safety, accessibility, convenience, and weather. A recent development, dynamic (or in-motion) wireless charging, enables EVs to charge wirelessly by incorporating charging infrastructure into roadways, allowing EVs to charge while moving. However, the energy transferred relies heavily on vehicle speed and time spent in the charging lane. This paper proposes an innovative solution that combines dynamic wire-less charging with Variable Speed Limit (VSL) control. This dynamic traffic control strategy adjusts speed limits based on real-time traffic, weather, and incidents. This integration of dynamic wireless charging and VSL has two potential benefits. First, it can motivate driver compliance with VSL through the incentive of charging. Second, it can promote smoother traffic flow and improve traffic safety by implementing lower speed limits at certain times. To verify these benefits, microscopic traffic simulations in SUMO were conducted under different EV penetration rates and VSL compliance rates. Simulation results reveal that the proposed approach can enhance dynamic wireless charging system performance while improving traffic flow and safety.
Reduced scale wind turbines can be extremely cost-effective to test new rotor concepts since prototype costs are heavily dependent on the rotor diameter. Ideally, the scaled model would have the same non-dimensional deflections, dynamics, and control behavior as the full-scale model. This would provide a high-fidelity demonstration of the full-scale performance, which is ideal if the full-scale turbine has significant aeroelastic interactions. To this end, servo-aero-gravo-elastic (SAGE) scaling is developed and applied to a 13-MW turbine that is scaled to a 20% scale model. The scaling preserves the tip-speed ratio, the rotor speed normalized by the flapping frequency, and the tip deflections normalized by the blade length. In addition, the controller employs the same control structure (gain-scheduled pitch control and variable speed torque control) and is scaled dynamically (e.g., matching non-dimensional time constant of the pitch angle, etc.). Furthermore, the thrust, gravity, and centrifugal moments are scaled such that the load angles are preserved as a function of a non-dimensional wind speed. However, the environmental scaling must consider differences in Reynolds number (since this parameter cannot be held constant) and subsequent changes in the axial induction factor. While the presented results showcase these differences during operational conditions, the non-dimensional tip deflections remain comparable through all wind speed ranges, indicating the viability of the SAGE scaling method in matching full-scale aeroelastic responses.
Heat pumps account for a significant portion of electricity consumption in buildings, making their energy efficiency a critical area of research. Control optimization is recognized as an effective approach for enhancing the efficiency of building HVAC systems. Specifically, since the efficiency of heat pumps increases with reduced superheat and the optimal refrigerant charge level varies with operating conditions, zero-superheat active charge control is a promising strategy to maximize the system’s COP. However, due to its complexity, this control strategy remains in the research phase and has only been tested under limited operating conditions. This paper proposes a methodology to evaluate the seasonal performance improvement of zero-superheat active charge control across a full range of heating conditions in buildings. The methodology includes the development of an optimal controller that utilizes an accumulator to store excess refrigerant and manages the active charge level at zero superheat through subcooling control, as well as the creation of a detailed physics-based heat pump model. Targeted a 3-ton variable-speed heat pump with R410A refrigerant, we selected ten U.S. cities representing different climate regions for seasonal performance evaluation. Our simulations indicate that, depending on the climate conditions, the optimal control strategy could achieve energy savings ranging from 5.8 % to 8.0 % over the entire heating season. These results suggest that zero-superheat active charge control, combined with coordinated compressor and fan speeds, could substantially improve the energy efficiency of heat pump systems while maintaining the required heating capacity.
This paper introduces a novel control framework for Lagrangian variable speed limits in hybrid traffic flow environments utilizing automated vehicles (AVs). The framework was validated using a fleet of 100 connected automated vehicles as part of the largest coordinated open-road test designed to smooth traffic flow. The framework includes two main components: a high-level controller deployed on the server side, named Speed Planner, and low-level controllers called vehicle controllers deployed on the vehicle side. The Speed Planner designs and updates target speeds for the vehicle controllers based on real-time Traffic State Estimation (TSE) [1]. The Speed Planner comprises two modules: a TSE enhancement module and a target speed design module. The TSE enhancement module is designed to minimize the effects of inherent latency in the received traffic information and to improve the spatial and temporal resolution of the input traffic data. The target speed design module generates target speed profiles with the goal of improving traffic flow. The vehicle controllers are designed to track the target speed meanwhile responding to the surrounding situation. The numerical simulation indicates the performance of the proposed method: the bottleneck throughput has increased by 5.01%, and the speed standard deviation has been reduced by a significant 34.36%. We further showcase an operational study with a description of how the controller was implemented on a field-test with 100 AVs and its comprehensive effects on the traffic flow.
Refrigerated display cases are widely-used, critical equipment in supermarkets for maintaining product safety and quality. Energy-efficient medium temperature liquid-cooled refrigerated display cases can save 25-70% of the total supermarket energy, according to manufacturers. Traditionally, cases operate by maintaining a temperature around a user-input setpoint that is dependent on the product in the case. Although cases are major electrical energy consumers, they are hardly ever considered for implementing load-flexibility strategies. With added load-flexibility capabilities, refrigerated display cases can shed (reduce), or shift (by adding and subsequently shedding) load. Supermarkets can reduce their energy costs and enhance electric grid integrity by implementing these smart load-flexibility control strategies. Advanced controls can also enable load-shifting to coincide with optimum periods of renewable energy generation. This will further improve operational costs and reduce greenhouse gas emissions without compromising food safety and quality. In this research, we have evaluated the energy savings of liquid-cooled medium temperature display cases and developed load flexibility strategies leveraging an advanced controls system, a variable speed compressor, and heat rejection via a water-cooled condenser. This study further assessed the impact of load flexibility strategies in a controlled environment chamber for a single refrigerated display case.
Micro-electromechanical systems (MEMS)-based sensors have seen significant improvements in accuracy and cost over the past several years, and due to the need for altitude sensing in unmanned aerial vehicles and wearable technologies, absolute pressure sensors have shown the most dramatic improvements. This paper investigates applications of MEMS sensors in commercial buildings, including pairing two absolute pressure sensors to determine differential pressures between different locations in and around buildings. Differential pressure measurements are commonly made in commercial buildings for a number of applications, including static pressure measurements for variable-speed supply fan control, air balancing in hospitals, and for envelope and duct air leakage testing. This paper focuses specifically on envelope air-leakage testing applications of these sensors. The use of continuous pressure measurements in addition to one-time non-intrusive outdoor airflow measurements of rooftop packaged units is investigated. A comparison with standardized leakage testing indicated that continuous measurements with MEMS pressure-sensors were able to estimate envelope leakage to within 3–16% of the standardized test result. In addition, the magnitude and stability of differential pressure differences that can be resolved with absolute pressure sensors are also investigated in the laboratory and the field. Results show that the sensors can be effectively used for pressures seen in low rise buildings with rooftop units.
The control systems at Air handling units (AHUs) have nonlinear nature, resulting potentially in sluggish, aggressive, or oscillatory responses under variable operation conditions. This paper is to develop an approach for evaluating the nonlinear control performance of AHUs under variable operation conditions and for identifying the impact of varying multiple operation parameters which guides controller design. To do so, an operation parameter-based root distribution technique, intended to sketch the paths traced by closed-loop poles as multiple operation parameters are varied, is first introduced. The technique—which may be viewed as an extension of conventional, single-variable root locus—is then applied to a fan speed control system that includes a motor with a variable frequency drive and a supply fan with an air duct under variable fan speed and duct static pressure. Using the technique, the system’s stability region is graphically identified. The system is also found to be aggressive and gradually lose its stability as the fan speed decreases and the duct static pressure increases, which is validated by the field tests. Here, the root distribution approach is an effective tool to evaluate the performance of any nonlinear control systems at AHUs with multiple variable operation parameters without requiring time-domain simulations.
Multiple sensor packages were deployed at Alpha-4 by SRNL, in collaboration with United Cleanup Oak Ridge LLC (UCOR), to monitor mercury vapor concentrations and meteorological parameters. These sensors collected data, inside and outside of the legacy-use facility, for approximately two years. Though data gaps still exist, particularly in colder months, several controlling variables were identified that govern mercury vapor concentrations within Alpha-4. Temperature, barometric pressure gradients, humidity, and wind speed have been identified as controlling variables. A strong positive correlation was seen between mercury vapor concentrations and temperature which generally followed diurnal fluctuations. Temperatures below approximately 10 degrees Celsius did not show any spikes above the PEL, indicating more work can be performed at any time during the winter months – more data should be collected to confirm consistency in this finding. Additionally, spikes in mercury vapor concentrations above that of the permissible exposure limit (PEL; 100 µg/m 3 ) occurred primarily in late afternoon or evening/overnight hours (between 3 PM and 6 AM), which suggests D&D operations might be best scheduled during morning or daytime hours prior to the late afternoon. However, a limited number of spikes did occur outside of the identified window, although this may be attributed to disturbances in air flow and mercury vapor release from work activities performed inside of the Alpha-4 building. The analysis conducted allows for a strong predictive capability for estimating mercury vapor concentrations based upon accurate meteorological parameters. Still, additional data collection, particularly in the winter months, could help to strengthen the predictive power and validate the identified data trends. Further, increased temporal resolution could also help to better characterize the incipient stages of the increases and decreases in the mercury vapor concentration. Continued monitoring support by SRNL at Y-12 is underway at Alpha-4 to further close remaining data gaps and support deactivation and decommissioning work. Within a collaborative effort with UCOR, the SRNL team is collecting mercury vapor data to study the efficacy of a novel mercury suppressant, FerroBlack® which was recently deployed at Alpha-4. In addition, modifications to the current monitoring setup to increase measurement resolution is also being investigated.
Industrial motor systems make up a quarter of all electric sales in the United States. Variable speed drives (VSDs) can provide energy efficiency savings to the customer by regulating motor speed based on specific and varying needs. In addition to the benefits provided to the customer, VSDs can provide support to the grid through ancillary services. The Center for Ultra-Wide-Area Resilient Electric Energy Transmission Networks (CURENT) developed a power electronics converter-based grid emulator to allow testing of various power system architectures and demonstration of key technologies in monitoring, control, actuation, and visualization. This paper proposes using an active front-end VSD's connected motor load to provide frequency regulation to a large scale power grid. Each part of the emulator is described including motor and power electronics model and control. The proposed frequency regulation is implemented in VSDs and modeled in both a transmission system in EMTDC/PSCAD and verified on CURENT's hardware testbed.
The use of heat pumps in cold and very cold climates increased by 63% between 2009 and 2015 [1, 2]. This can be attributed to development of heat pumps with higher heating capacity at lower temperatures and increased efficiency. A primary technology driving this trend is the use of variable-speed compressors, which come with an increase in the level of controls in the equipment. Most units with variable-speed compressors also include electronic expansion valves and variable-speed indoor (ID) and outdoor (OD) fans. With the increased complexity of these systems, developing a test procedure that is representative of typical performance and not too burdensome on manufacturers presents a difficult challenge.
Heat pumps play an instrumental role in buildings decarbonization strategies. Recent advances in heat pump systems employ variable-speed compressor technology and electronically commutated fan motors. Inherently, the heating capacity and efficiency of heat pumps decrease with falling outdoor temperatures. Compared to single-speed heat pumps, variable speed systems can maintain higher heating and cooling efficiencies over a wider range of outdoor temperatures. The goal of this multi-phase project was to determine the energy savings of a high efficiency, variable-speed, air-source, split system heat pump designed for cold climate applications. The first project phase was to evaluate the performance of the heat pump in the laboratory under varying outdoor conditions in heating and cooling modes. The second phase was to translate the laboratory-measured performance into lookup tables for EnergyPlus hourly building simulation engine. Then, two sets of annual building simulations were performed using typical meteorological year weather from the Chicago-O'Hare airport for three different building types (a single-family residence, a strip mall, and a low-rise office building). The first set simulated a standard efficiency heat pump while the second set utilized the phase two performance tables to model a high efficiency heat pump. The high efficiency heat pump produced significant annual heating energy savings in all three buildings. The variable speed compressor and fan control also contributed to cooling energy savings. The simulated annual energy savings ranged from 22% to 35% over their respective baseline. The project's findings helped a Midwest electric utility, Commonwealth Edison (ComEd), design new incentives around high efficiency heat pumps.
Radiolysis of water in nuclear waste storage generates hydrogen gas that can accumulate within sludge style waste and be rapidly released during agitation events, creating a significant flammability hazard. Engineering controls are therefore required to limit hydrogen concentrations during both quiescent storage and transient disturbances. Catalytic recombination of hydrogen in waste storage offgas is a proven mitigation strategy, maintaining hydrogen levels below flammability limits and managing sudden concentration spikes. Conventional recombiners rely on platinum and/or palladium catalysts, with development efforts focused on extending service life, increasing active surface area, and ensuring safe deployment in radioactive environments. Savannah River National Laboratory (SRNL) is evaluating a newly developed hydrogen recombiner catalyst from Canadian Nuclear Laboratories as a cost-effective and durable alternative for nuclear waste applications. Testing was conducted in SRNL’s Shielded Cells facility, which enables reduced-scale experimental modeling under radiation fields and near-use-case conditions relevant to radioactive waste storage. Catalyst performance was evaluated using a custom offgas characterization system designed for near-zero flow conditions. The experimental apparatus consisted of a gas-tight 2.7 L PTFE vessel equipped with temperature monitoring, gas flow controls, and a variable-speed mixer to simulate sludge agitation. Offgas composition was monitored using a dedicated gas chromatograph with argon carrier gas and a krypton internal standard. Measurements were obtained for an empty vessel, the vessel containing a well characterized radioactive tank waste sample, and the same configuration with the candidate catalyst installed. Results demonstrate that the new catalyst effectively reduced hydrogen concentrations in the offgas within the constraints of the experimental design. In addition to confirming catalytic activity, the testing provided valuable insights into experimental optimization and considerations for future performance evaluations. These findings support the potential scalability of the technology and highlight its applicability to broader nuclear waste management operations, offering improved safety and reduced operational costs through enhanced catalyst durability and lower replacement frequency.
This project is part of a joint effort between Commonwealth Edison Company (ComEd) and the National Renewable Energy Laboratory (NREL) to evaluate the energy and demand savings potential of emerging efficient buildings technologies. This project quantifies the energy efficiency benefits from retrofitting an air-cooled, constant-speed compression, self-contained medium-temperature open-vertical display case with a high efficiency water-cooled condensing unit. In addition to a water-cooled heat rejection mechanism, the high-efficiency condensing unit utilizes a variable-speed compressor, electronic expansion valve and advanced controls system. The focus of this project, however, was mainly on capturing the energy savings potentials of the water-cooled condenser, variable-speed compression and electronic expansion valve, and not on the advanced controls. The results of this evaluation will be considered by ComEd and CLEAResult for future energy efficiency rebate offerings.
The energy efficiency of today’s vehicular mobility relies on the un-integrated combination of i) control via static assets (traffic lights, metering, variable speed limits, etc.); and ii) onboard vehicle automation (adaptive cruise control (ACC), ecodriving, etc.). These two families of control were not co-designed and are not engineered to work in coordination. Recent studies have shown i) limitations of controls, and even ii) negative impacts of ACC. This project focused on the technology development, implementation and prototyping, and validation of Mobile Traffic Control (MTC). MTC can be viewed as an extension of classical traffic control (in which static infrastructure actuates traffic flow). In the MTC paradigm, automated vehicles actuate the entire flow via their behavior, offering enhanced possibilities to optimize the energy footprint of traffic, if designed correctly. We set out to demonstrate for the first time that considerably reduced fuel consumption of all vehicles in traffic can be achieved via distributed control of a small proportion of CAVs. Compared to baseline vehicular technologies, our work offers a significant design departure: control algorithms for the CAVs consider the impact one vehicle can have on overall traffic, improving resulting overall fuel consumption. We focus on using a few vehicles (as traffic controllers via CAV technology) to improve the energy efficiency of traffic flow to further optimize energy efficiency. A live-traffic demonstration in November 2022 featured the deployment of 100 specially-equipped CAVs, constituting an approximate local penetration rate upwards of 2%.
Electric power systems are undergoing a rapid transition from fuel-based generation using synchronous generators to renewable generation interfaced by power electronics. In this context, a key challenge is using renewable generation with limited controllability to contribute to power system stability. In this work, we investigate grid-forming control of permanent magnet synchronous generator (PMSG) wind turbines. The proposed control and curtailment strategy supports the entire spectrum of standard functions of grid-following (e.g. maximum power point tracking (MPPT) and grid-forming control (e.g., primary frequency control) without explicit mode switching. A detailed case study is used to compare the performance of the proposed control at operating points corresponding to MPPT and frequency control with standard grid-forming and grid-following controls. Further, the results demonstrate that (i) the proposed energy balancing grid forming control is self-synchronizing in MPPT mode, (ii) the (limited) energy storage and controllability of wind turbines can be adequately utilized to provide grid support, and (ii) the proposed control exhibits good performance under variable wind speeds and does not result in a significant increase of wind turbine fatigue loads.
This article highlights work at Oak Ridge National Laboratory’s Manufacturing Demonstration Facility to develop closed-loop, feedback control for laser-wire based Directed Energy Deposition, a form of metal Big Area Additive Manufacturing (m-BAAM), a process being developed in partnership with GKN Aerospace specifically for the production of Ti-6Al-4V pre-forms for aerospace components. A large-scale structural demonstrator component is presented as a case-study in which not just control, but the entire 3D printing workflow for m-BAAM is discussed in detail, including design principles for large-format metal AM, toolpath generation, parameter development, process control, and system operation, as well as post-print net-shape geometric analysis and finish machining. In terms of control, a multi-sensor approach has been utilized to measure both layer height and melt pool size, and multiple modes of closed-loop control have been developed to manipulate process parameters (laser power, print speed, deposition rate) to control these variables. Layer height control and melt pool size control have yielded excellent local (intralayer) and global (component-level) geometry control, and the impact of melt pool size control in particular on thermal gradients and material properties is the subject of continuing research. Further, these modes of control have allowed the process to advance to higher deposition rates (exceeding 7.5 lb/hr), larger parts (1-meter scale), shorter build times, and higher overall efficiency. The control modes are examined individually, highlighting their development, demonstration, and lessons learned, and it is shown how they operate concurrently to enable the printing of a large-scale, near net shape Ti-6Al-4V component.