Search NASA⌕ Search

SEARCH · Search NASA

Results for “vertical channel design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Designing Low Tortuosity Electrodes through Pattern Optimization for Fast-Charging

The development of fast-charging technologies is crucial for expediting the progress and promotion of electric vehicles. In addition to innovative material exploration, reduction in the tortuosity of electrodes is a favored strategy to enhance the fast-charging capability of lithium-ion batteries by optimizing the ion-transfer kinetics. To realize the industrialization of low-tortuosity electrodes, a facile, cost-effective, highly controlled, and high-output continuous additive manufacturing roll-to-roll screen printing technology is proposed to render customized vertical channels within electrodes. Extremely precise vertical channels are fabricated by applying the as-developed inks, using LiNi 0.6 Mn 0.2 Co 0.2 O 2 as the cathode material. Additionally, the relationship between the electrochemical properties and architecture of the channels, including the pattern, channel diameter, and edge distance between channels, is revealed. The optimized screen-printed electrode exhibited a seven-fold higher charge capacity (72 mAh g -1 ) at a current rate of 6 C and superior stability compared with that of the conventional bar-coated electrode (10 mAh g -1 , 6 C) at a mass loading of 10 mg cm -2 . Finally, this roll-to-roll additive manufacturing can potentially be applied to various active materials printing to reduce electrode tortuosity and enable fast charging in battery manufacturing.

42 ENGINEERING↗

Gradient Architecture Design in Scalable Porous Battery Electrodes

Because it has been demonstrated to be effective toward faster ion diffusion inside the pore space, low-tortuosity porous architecture has become the focus in thick electrode designs, and other possibilities are rarely investigated. Here, to advance current understanding in the structure-affected electrochemistry and to broaden horizons for thick electrode designs, we present a gradient electrode design, where porous channels are vertically aligned with smaller openings on one end and larger openings on the other. With its 3D morphology carefully visualized by Raman mapping, the electrochemical properties between opposite orientations of the gradient electrodes are compared, and faster energy storage kinetics is found in larger openings and more concentrated active material near the separator. As further verified by simulation, this study on gradient electrode design deepens the knowledge of structure-related electrochemistry and brings perspectives in high-energy battery electrode designs.

25 ENERGY STORAGE↗

High-resolution multiwire proportional soft x-ray diagnostic measurements on TCV

A multiwire proportional x-ray (MPX) detector is used on the TCV tokamak (Tokamak a configuration variable) as a high spatial and temporal resolution soft x-ray emissivity imaging diagnostic. The MPX system consists of 64 vertically viewing channels and has been designed to complement the existing TCV soft x-ray tomography system by enhancing the spatial resolution. The MPX detector is suitable for the measurement of fast and localized phenomena and can be used, for instance, for the observation of magnetohydrodynamic activity, for the characterization of transport barriers or for an improved determination of the electron cyclotron heating power deposition profile. The MPX detector operates in continuous-current mode and measures the plasma soft x-ray emission in the 3-30 keV range with a radial resolution of about 5 mm - 1% of plasma diameter - and a frequency bandwidth of 50 kHz. A detailed description of the MPX detector construction and the principle of its operation are given. The properties of the detector in photon-counting and continuous-current operation modes are studied. The implementation of the system on TCV and experimental results illustrating the potential of the diagnostic are also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design, fabrication, and performance analysis of GaN vertical electron transistors with a buried p/n junction

The Current Aperture Vertical Electron Transistor (CAVET) combines the high conductivity of the two dimensional electron gas channel at the AlGaN/GaN heterojunction with better field distribution offered by a vertical design. In this work, CAVETs with buried, conductive p-GaN layers as the current blocking layer are reported. The p-GaN layer was regrown by metalorganic chemical vapor deposition and the subsequent channel regrowth was done by ammonia molecular beam epitaxy to maintain the p-GaN conductivity. Transistors with high ON current (10.9 kA/cm{sup 2}) and low ON-resistance (0.4 mΩ cm{sup 2}) are demonstrated. Non-planar selective area regrowth is identified as the limiting factor to transistor breakdown, using planar and non-planar n/p/n structures. Planar n/p/n structures recorded an estimated electric field of 3.1 MV/cm, while non-planar structures showed a much lower breakdown voltage. Lowering the p-GaN regrowth temperature improved breakdown in the non-planar n/p/n structure. Combining high breakdown voltage with high current will enable GaN vertical transistors with high power densities.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal strains in focusing channels of the stations for X-ray diffraction analysis in the Sibir-2 storage ring

The thermal load caused by the absorption of synchrotron radiation in X-ray optical elements of the Belok and RSA stations leads to optics elements heating and induces strains upon simultaneous cooling. The heating of the cooled first crystal in the double-crystal monochromator causes its bending and increases the reflected beam divergence, which, in turn, results in the monochromatic beam intensity loss [1]. Numerical simulation makes it possible to more accurately determine the strains, choose the optimal monochromator design, estimate the vertical sizes of the focal spot and wavelength resolution in the focusing channel, correctly design the system for cooling the mirror at the channel input, and choose a design providing the minimum temperature of the beam-limiting slit knives.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Conceptual design study for heat exhaust management in the ARC fusion pilot plant

The ARC pilot plant conceptual design study has been extended beyond its initial scope to explore options for managing ∼525 MW of fusion power generated in a compact, high field (B 0 = 9.2 T) tokamak that is approximately the size of JET (R 0 = 3.3 m). Taking advantage of ARC’s novel design – demountable high temperature superconductor toroidal field (TF) magnets, poloidal magnetic field coils located inside the TF, and vacuum vessel (VV) immersed in molten salt FLiBe blanket – this follow-on study has identified innovative and potentially robust power exhaust management solutions. The superconducting poloidal field coil set has been reconfigured to produce double-null plasma equilibria with a long-leg X-point target divertor geometry. Here this design choice is motivated by recent modeling which indicates that such configurations enhance power handling and may attain a passively-stable detachment front that stays in the divertor leg over a wide power exhaust window. A modified VV accommodates the divertor legs while retaining the original core plasma volume and TF magnet size. The molten salt FLiBe blanket adequately shields all superconductors, functions as an efficient tritium breeder, and, with augmented forced flow loops, serves as an effective single-phase, low-pressure coolant for the divertor, VV, and breeding blanket. Advanced neutron transport calculations (MCNP) indicate a tritium breeding ratio of ∼1.08. The neutron damage rate (DPA/year) of the remote divertor targets is ∼3–30 times lower than that of the first wall. The entire VV (including divertor and first wall) can tolerate high damage rates since the demountable TF magnets allow the VV to be replaced every 1–2 years as a single unit, employing a vertical maintenance scheme. A tungsten swirl tube FLiBe coolant channel design, similar in geometry to that used by ITER, is considered for the divertor heat removal and shown capable of exhausting divertor heat flux levels of up to 12 MW/m 2 . Several novel, neutron tolerant diagnostics are explored for sensing power exhaust and for providing feedback control of divertor conditions over long time scales. These include measurement of Cherenkov radiation emitted in FLiBe to infer DT fusion reaction rate, measurement of divertor detachment front locations in the divertor legs with microwave interferometry, and monitoring “hotspots” on the divertor chamber walls via IR imaging through the FLiBe blanket.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aerosol backscatter studies supporting LAWS

Optimized Royal Signals and Radar Establishment (RSRE), Laser True Airspeed System (LATAS) algorithm for low backscatter conditions was developed. The algorithm converts backscatter intensity measurements from focused continuous-wave (CW) airborne Doppler lidar into backscatter coefficients. The performance of optimized algorithm under marginal backscatter signal conditions was evaluated. The 10.6 micron CO2 aerosol backscatter climatologies were statistically analyzed. Climatologies reveal clean background aerosol mode near 10(exp -10)/kg/sq m/sr (mixing ratio units) through middle and upper troposhere, convective mode associated with planetary boundary layer convective activity, and stratospheric mode associated with volcanically-generated aerosols. Properties of clean background mode are critical to design and simulation studies of Laser Atmospheric Wind Sounder (LAWS), a MSFC facility Instrument on the Earth Observing System (Eos). Previous intercomparisons suggested correlation between aerosol backscatter at CO2 wavelength and water vapor. Field measurements of backscatter profiles with MSFC ground-based Doppler lidar system (GBDLS) were initiated in late FY-88 to coincide with independent program of local rawinsonde releases and overflights by Multi-spectral Atmospheric Mapping Sensor (MAMS), a multi-channel infrared radiometer capable of measuring horizontal and vertical moisture distributions. Design and performance simulation studies for LAWS would benefit from the existence of a relationship between backscatter and water vapor.

Rothermel, Jeffry↗

Innovations in optical coupling of the KSTAR electron cyclotron emission imaging diagnostic

The installation of a new electron cyclotron emission imaging diagnostic for the Korea Superconducting Tokamak Advanced Research (KSTAR) is underway, making use of a unique optical port cassette design, which allows placement of refractive elements inside the cryostat region without adverse effects. The result is unprecedented window access for the implementation of a state of the art imaging diagnostic. A dual-array optical design has been developed, capable of simultaneously imaging the high and low field sides of the plasma with independent features of focal plane translation, vertical zoom, and radial channel spacing. The number of translating optics has been minimized by making use of a zoom lens triplet and parabolic plasma facing lens for maximum channel uniformity over a continuous vertical zoom range of 3:1. The simulated performance of this design is presented along with preliminary laboratory characterization data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design, development, and field testing of Infrared Heterodyne Radiometer (IHR) for remote profiling of tropospheric and stratospheric species

The performance of a dual-channel infrared heterodyne radiometer, designed to remotely monitor the concentration and vertical distribution of selected atmospheric species, is described. Ground based solar viewing measurement using the IHR were performed at selected laser transitions for ammonia (NH3 and ozone O3). Flight tests were conducted aboard the Galileo II, NASA Ames CV-990, on the Latitude Survey Mission. Ozone was the selected atmospheric species for the airborne flight measurements because of the scientific interest in this atmospheric species, the availability of in situ monitors, the coordinated ozone measurements, and the availability of ground truth data. The IHS was operated in the solar viewing mode to determine ozone distributions in the stratosphere and in the nadir viewing mode to determine the ozone distribution in the troposphere. Airborne atmospheric propagation measurements also were carried out at selected CO2 laser transitions.

Lange, R.↗

Screen Channel Liquid Acquisition Device Outflow Tests in Liquid Hydrogen

This paper presents experimental design and test results of the recently concluded 1-g inverted vertical outflow testing of two 325x2300 full scale liquid acquisition device (LAD) channels in liquid hydrogen (LH2). One of the channels had a perforated plate and internal cooling from a thermodynamic vent system (TVS) to enhance performance. The LADs were mounted in a tank to simulate 1-g outflow over a wide range of LH2 temperatures (20.3 - 24.2 K), pressures (100 - 350 kPa), and flow rates (0.010 - 0.055 kg/s). Results indicate that the breakdown point is dominated by liquid temperature, with a second order dependence on mass flow rate through the LAD. The best performance is always achieved in the coldest liquid states for both channels, consistent with bubble point theory. Higher flow rates cause the standard channel to break down relatively earlier than the TVS cooled channel. Both the internal TVS heat exchanger and subcooling the liquid in the propellant tank are shown to significantly improve LAD performance.

Liquid Acquisition Device↗

Universal Millimeter-Wave Radar Front End

A quasi-optical front end allows any arbitrary polarization to be transmitted by controlling the timing, amplitude, and phase of the two input ports. The front end consists of two independent channels horizontal and vertical. Each channel has two ports transmit and receive. The transmit signal is linearly polarized so as to pass through a periodic wire grid. It is then propagated through a ferrite Faraday rotator, which rotates the polarization state 45deg. The received signal is propagated through the Faraday rotator in the opposite direction, undergoing a further 45 of polarization rotation due to the non-reciprocal action of the ferrite under magnetic bias. The received signal is now polarized at 90deg relative to the transmit signal. This signal is now reflected from the wire grid and propagated to the receive port. The horizontal and vertical channels are propagated through, or reflected from, another wire grid. This design is an improvement on the state of the art in that any transmit signal polarization can be chosen in whatever sequence desired. Prior systems require switching of the transmit signal from the amplifier, either mechanically or by using high-power millimeter-wave switches. This design can have higher reliability, lower mass, and more flexibility than mechanical switching systems, as well as higher reliability and lower losses than systems using high-power millimeter-wave switches.

Perez, Raul M.↗

CALIGOLA: A New Multidisciplinary Spaceborne Lidar Mission (Cloud Aerosol Lidar for Global scale Observations of the ocean-Land-Atmosphere system)

Spaceborne lidars provide unique and valuable insight into the vertical structure of clouds and aerosols over the globe as well as insight into their microphysical and optical properties. Over the past two decades, lidar observations from CALIPSO, ICESAT-2 and CATS fundamentally advanced our understanding of the roles of clouds and aerosols play in weather, climate and air quality. The measurement records further served as important references for validating and improving retrieval algorithms of cloud/aerosol properties from operational weather satellites. A more recent development is the emerging awareness on how spaceborne lidar profile observations can also enhance knowledge of Earth’s coupled atmosphere-ocean-land system. Here we report on a new and powerful spaceborne lidar mission concept known as CALIGOLA (Cloud Aerosol Lidar for Global Scale Observations of the Ocean-Land Atmosphere System). The mission is multidisciplinary and will provide new insights into atmospheric processes with advance measurement capabilities beyond CALIPSO and the recently launched EarthCARE mission. CALIGOLA will further provide the first profiling of the world’s oceans to reveal unprecedented observations on the health and productivity of marine biology (phytoplankton and zooplankton) as well as provide unique observations of surface vegetation, ice, and snow. The mission will feature an innovative three-wavelength lidar, that will simultaneously acquire elastic backscatter, Raman, and fluorescence measurements, with polarization sensitivity on the elastic channels. The instrument is further designed with greater sensitivity than CALIOP and with vertical resolution on the order of a few meters near the surface. The mission is planned for launch early next decade and is baselined to fly in a polar orbit that is compatible with the previous A-Train constellation to extend the long-term measurement record. CALIGOLA is being developed through a partnership between Agenzia Spaziale Italiana (ASI) and National Aeronautics and Space Administration (NASA).

Lidar Aerosols Clouds Ocean Biology↗

Distribution of air-water mixtures in parallel vertical channels as an effect of the header geometry

Uneven phase distribution in heat exchangers is a cause of severe reductions in thermal performances of refrigeration equipment. To date, no general design rules are available to avoid phase separation in manifolds with several outlet channels, and even predicting the phase and mass distribution in parallel channels is a demanding task. In the present paper, measurements of two-phase air-water distributions are reported with reference to a horizontal header supplying 16 vertical upward channels. The effects of the operating conditions, the header geometry and the inlet port nozzle were investigated in the ranges of liquid and gas superficial velocities of 0.2-1.2 and 1.5-16.5 m/s, respectively. Among the fitting devices used, the insertion of a co-axial, multi-hole distributor inside the header confirmed the possibility of greatly improving the liquid and gas flow distribution by the proper selection of position, diameter and number of the flow openings between the supplying distributor and the system of parallel channels connected to the header. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Two-phase flow in helical and spiral coils

Coiled tube heat exchangers involving two-phase flows are used in a variety of application areas, extending from the aerospace industry to petrochemical, refrigeration land power generation industries. The optimal design in each situation requires a fundamental understanding of the heat, mass and momentum transfer characteristic of the flowing two-phase mixture. However, two-phase flows in lengths of horizontal or vertical straight channels with heat transfer are often quite difficult in themselves to understand sufficiently well to permit accurate system designs. The present study has the following general objectives: (1) Observe two-phase flow patterns of air-water and R-113 working fluids over a range of flow conditions, for helical and spiral coil geometries, of circular and rectangular cross-section; (2) Compare observed flow patterns with predictions of existing flow maps; (3) Study criteria for flow regime transitions for possible modifications of existing flow pattern maps; and (4) Measure associated pressure drops across the coiled test sections over the rage of flow conditions specified.

Keshock, Edward G.↗

Note: Design principles of a linear array multi-channel effusive metal-vapor atom source

Atomic beams can easily be produced by allowing atoms to effuse through a channel. In an earlier investigation [A. Majumder et al., Vacuum 83, 989 (2009)], we had designed, fabricated, and characterized an effusive metal-vapor source using collinear-array of multi-channel. In this note, we describe the theoretical basis of designing the source. Atom density in atomic beam has been estimated using a set of analytical expressions for long-channel operated in transparent mode. Parametric studies on aspect ratio of channel, inter-channel separation, beam width, and vertical distance from the source are carried out. They are useful in providing physical picture and optimizing design parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optics design for J-TEXT ECE imaging with field curvature adjustment lens

Significant progress has been made in the imaging and visualization of magnetohydrodynamic and microturbulence phenomena in magnetic fusion plasmas. Of particular importance has been microwave electron cyclotron emission imaging (ECEI) for imaging T{sub e} fluctuations. Key to the success of ECEI is a large Gaussian optics system constituting a major portion of the focusing of the microwave radiation from the plasma to the detector array. Both the spatial resolution and observation range are dependent upon the imaging optics system performance. In particular, it is critical that the field curvature on the image plane is reduced to decrease crosstalk between vertical channels. The receiver optics systems for two ECEI on the J-TEXT device have been designed to ameliorate these problems and provide good performance with additional field curvature adjustment lenses with a meniscus shape to correct the aberrations from several spherical surfaces.

43 PARTICLE ACCELERATORS↗

Convective heat transfer to CO{sub 2} at a supercritical pressure flowing vertically upward in tubes and an annular channel

The Super-Critical Water-Cooled Reactor (SCWR) has been chosen by the Generation IV International Forum as one of the candidates for the next generation nuclear reactors. Heat transfer to water from a fuel assembly may deteriorate at certain supercritical pressure flow conditions and its estimation at degraded conditions as well as in normal conditions is very important to the design of a safe and reliable reactor core. Extensive experiments on a heat transfer to a vertically upward flowing CO{sub 2} at a supercritical pressure in tubes and an annular channel have been performed. The geometries of the test sections include tubes of an internal diameter (ID) of 4.4 and 9.0 mm and an annular channel (8 x 10 mm). The heat transfer coefficient (HTC) and Nusselt numbers were derived from the inner wall temperature converted by using the outer wall temperature measured by adhesive K-type thermocouples and a direct (tube) or indirect (annular channel) electric heating power. From the test results, a correlation, which covers both a deteriorated and a normal heat transfer regime, was developed. The developed correlation takes different forms in each interval divided by the value of parameter Bu. The parameter Bu (referred to as Bu hereafter), a function of the Grashof number, the Reynolds number and the Prandtl number, was introduced since it is known to be a controlling factor for the occurrence of a heat transfer deterioration due to a buoyancy effect. The developed correlation predicted the HTCs for water and HCFC-22 fairly well. (author)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Diamond as a solid state micro-fission chamber for thermal neutron detection at the VR-1 research reactor

Diamond exhibits a combination of properties which makes it attractive for neutron detection in hostile conditions. In the particular case of detection in a nuclear reactor, it is resilient to radiation, exhibits a natural low sensitivity to gamma rays, and its small size (as compared with that of gas ionisation chambers) enables fluency monitoring with a high position resolution. We report here on the use of synthetic CVD diamond as a solid state micro-fission chamber with U-235 converting material for in-core thermal neutron monitoring. Two types of thin diamond detectors were developed for this application. The first type of detector is fabricated using thin diamond membrane obtained by etching low-cost commercially available single crystal CVD intrinsic diamond, so called 'optical grade' material. Starting from a few hundred of micrometre thick samples, the sample is sliced with a laser and then plasma etched down to a few tenths of micrometre. Here we report the result obtained with a 17 μm thick device. The detection surface of this detector is equal to 1 mm{sup 2}. Detectors with surfaces up to 1 cm{sup 2} can be fabricated with this technique. The second type of detector is fabricated by growing successively two thin films of diamond, by the microwave enhanced chemical vapour deposition technique, on HPHT single crystal diamond. A first, a film of boron doped (p+) single crystal diamond, a few microns thick, is deposited. Then a second film of intrinsic diamond with a thickness of a few tens of microns is deposited. This results in a P doped, Intrinsic, Metal structure (PIM) structure in which the intrinsic volume id the active part of the detector. Here we report the results obtained with a 20 μm thick intrinsic whose detection surface is equal to 0.5 mm{sup 2}, with the possibility to enlarge the surface of the detector up to 1 cm{sup 2}. These two types of detector were tested at the VR-1 research reactor at the Czech Technical University in Prague. The Training Reactor VR-1 is a pool type (light water) reactor based on UO{sub 2} low enriched uranium. It has a nominal power of 1 kW, and can be operated for a short period up to 5 kW. The arrangement of the reactor pool reactor facilitates access to the core, setting and removal of various experimental samples and detectors, and safe and easy handling of fuel assemblies. The reactor is equipped with two horizontal channels (radial and tangential) and 10 vertical channels, of varying diameters, which can be loaded into various core positions, and one pneumatic transfer system. It is also equipped with several specifically designed educational instrumentation systems that can be used to supply complementary measurements and characterization around the reactor. The reactor is operated by the Department of Nuclear Reactors of the Faculty of Nuclear Sciences and Physical Engineering of the Czech Technical University in Prague. The two detectors were placed in-core through one of the vertical insertion channel. They were coupled to remote placed (5 m BNC cable) classical nuclear charge sensitive electronics. Detection properties of both sensors, including: pulse height spectra of U-235 fission fragments (response linearity with neutron flux, count rate, gamma background, were evaluated varying the power of the reactor from 0.005 W to 500 W. The evolution of the counting rate of the thinned optical grade detector as a function of counting rate of a gas ionization chamber used currently for reactor monitoring shows the very good linearity of the detector over the 5 decades. Similar results were obtained with the PIM detector. Additionally fast transient current signals of the detectors were recorded on a digital storage oscilloscope (DSO) using broad-band amplifier and with a simple bias-T, showing potential use of such sensors for neutron counting with no need of an amplification stage, since non-amplified signals from fission fragments exceeded 4 mV in amplitude. Therefore, one can think of simple neutron counting system by feeding diamond detectors signals directly to the low threshold discriminators. The results obtained on the VR1 will be described and discussed in detail in the paper and associated presentation. The results demonstrate that diamond micro-fission chambers can be used for in-core neutron monitoring, where robust, simple and compact devices are required.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗