Search NASA⌕ Search

SEARCH · Search NASA

Results for “vertical diodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Novel, Free-Space Optical Interconnect Employing Vertical-Cavity Surface Emitting Laser Diodes and InGaAs Metal-Semiconductor-Metal Photodetectors for Gbit/s RF/Microwave Systems

Emerging technologies and continuing progress in vertical-cavity surface emitting laser (VCSEL) diode and metal-semiconductor-metal (MSM) photodetector research are making way for novel, high-speed forms of optical data transfer in communication systems. VCSEL diodes operating at 1550 nm have only recently become commercially available, while MSM photodetectors are pushing the limits of contact lithography with interdigitated electrode widths reaching sub micron levels. We propose a novel, free-space optical interconnect operating at about 1Gbit/s utilizing VCSEL diodes and MSM photodetectors. We report on development, progress, and current work, which are as follows: first, analysis of the divergent behavior of VCSEL diodes for coupling to MSM photodetectors with a 50 by 50 m active area and second, the normalized frequency response of the VCSEL diode as a function of the modulating frequency. Third, the calculated response of MSM photodetectors with varying electrode width and spacing on the order of 1 to 3 m as well as the fabrication and characterization of these devices. The work presented here will lead to the formation and characterization of a fully integrated 1Gbit/s free-space optical interconnect at 1550 nm and demonstrates both chip level and board level functionality for RF/microwave digital systems.

Savich, Gregory R.↗

Nanotunneling Junction-based Hyperspectal Polarimetric Photodetector and Detection Method

A photodetector, detector array, and method of operation thereof in which nanojunctions are formed by crossing layers of nanowires. The crossing nanowires are separated by a few nm thick electrical barrier layer which allows tunneling. Each nanojunction is coupled to a slot antenna for efficient and frequency-selective coupling to photo signals. The nanojunctions formed at the intersection of the crossing wires defines a vertical tunneling diode that rectifies the AC signal from a coupled antenna and generates a DC signal suitable for reforming a video image. The nanojunction sensor allows multi/hyper spectral imaging of radiation within a spectral band ranging from terahertz to visible light, and including infrared (IR) radiation. This new detection approach also offers unprecedented speed, sensitivity and fidelity at room temperature.

Son, Kyung-ah↗

Mathematical optimization of photovoltaic converters for diode lasers

The mathematical optimization of vertical-junction photovoltaic converters for use with diode laser arrays supplying powers up to 1 MW is discussed. Photovoltaic parameters were optimized using a mathematical model. The optimized converters have 500 single junctions connected in series. The efficiency varies from 41 percent for a 0.73-micron diode laser to 46 percent for a 0.83-micron diode laser. The optimum width of the single-junction converter is small, 3.0 microns, in order for the p-n junction to be within a diffusion length of the light-generated carriers. Another critical parameter is the series resistance; the optimum value of 0.001 ohms should be achievable. Another critical parameter is the donor carrier concentration, for which an optimum value of 5 x 10 to the 15th carriers/cu cm has been chosen.

Walker, Gilbert H.↗

High Density Memory Based on Quantum Device Technology

We explore the feasibility of ultra-high density memory based on quantum devices. Starting from overall constraints on chip area, power consumption, access speed, and noise margin, we deduce boundaries on single cell parameters such as required operating voltage and standby current. Next, the possible role of quantum devices is examined. Since the most mature quantum device, the resonant tunneling diode (RTD) can easily be integrated vertically, it naturally leads to the issue of 3D integrated memory. We propose a novel method of addressing vertically integrated bistable two-terminal devices, such as resonant tunneling diodes (RTD) and Esaki diodes, that avoids individual physical contacts. The new concept has been demonstrated experimentally in memory cells of field effect transistors (FET's) and stacked RTD's.

vanderWagt, Paul↗

Quantitative Measurement of Oxygen in Microgravity Combustion

A low-gravity environment, in space or in ground-based facilities such as drop towers, provides a unique setting for studying combustion mechanisms. Understanding the physical phenomena controlling the ignition and spread of flames in microgravity has importance for space safety as well as for better characterization of dynamical and chemical combustion processes which are normally masked by buoyancy and other gravity-related effects. Due to restrictions associated with performing measurements in reduced gravity, diagnostic methods which have been applied to microgravity combustion studies have generally been limited to capture of flame emissions on film or video, laser Schlieren imaging and (intrusive) temperature measurements using thermocouples. Given the development of detailed theoretical models, more sophisticated diagnostic methods are needed to provide the kind of quantitative data necessary to characterize the properties of microgravity combustion processes as well as provide accurate feedback to improve the predictive capabilities of the models. When the demands of space flight are considered, the need for improved diagnostic systems which are rugged, compact, reliable, and operate at low power becomes apparent. The objective of this research is twofold. First, we want to develop a better understanding of the relative roles of diffusion and reaction of oxygen in microgravity combustion. As the primary oxidizer species, oxygen plays a major role in controlling the observed properties of flames, including flame front speed (in solid or liquid flames), extinguishment characteristics, flame size and flame temperature. The second objective is to develop better diagnostics based on diode laser absorption which can be of real value in both microgravity combustion research and as a sensor on-board Spacelab as either an air quality monitor or as part of a fire detection system. In our prior microgravity work, an eight line-of-sight fiber optic system measured water vapor mole fractions in the NASA Lewis 2.2-sec Drop Tower. In that system, the laser and all electronics resided at the top of the drop tower and was connected via a fiber optic cable to the rig, on which a 'pitch and catch' set of fiber collimating lenses were used to transmit the laser beam across a jet diffusion flame. This system required eight independent detection/demodulation units and had poor spatial resolution. This research builds on this earlier work, resulting in an improved capability for quantitative, nonintrusive measurement of major combustion species. A vertical cavity surface-emitting diode laser (VCSEL) and a continuous spatial scanning method permit the measurement of temporal and spatial profiles of the concentrations and temperatures of molecular oxygen. High detection sensitivity is achieved with wavelength modulation spectroscopy (WMS). One-g experiments are performed using a slot diffusion flame. Microgravity measurements on a solid fuel (cellulose sheet) system are planned for the NASA Lewis 2.2-second Drop Tower Facility.

Silver, Joel A.↗

Qualitative evaluation of a conformal velocity vector display for use at high angles-of-attack in fighter aircraft

A piloted simulation study was conducted to evaluate the utility of a display device designed to illustrate graphically and conformally the approximate location of a fighter aircraft's velocity vector. The display device consisted of two vertical rows of light emitting diodes (LED's) located toward the center of the cockpit instrument panel to each side of the control stick. The light strings provided a logical extension of the head up display (HUD) velocity vector symbol at flight path angles which exceeded the HUD field-of-view. Four test subjects flew a modified F/A-18 model with this display in an air-to-air engagement task against an equally capable opponent. Their responses to a questionnaire indicated that the conformal velocity vector information could not be used during the scenarios investigated due to the inability to visually track a target and view the lights simultaneously.

Jones, Denise R.↗

Quantitative measurement of oxygen in microgravity combustion

This research combines two innovations in an experimental system which should result in a new capability for quantitative, nonintrusive measurement of major combustion species. Using a newly available vertical cavity surface-emitting diode laser (VCSEL) and an improved spatial scanning method, we plan to measure the temporal and spatial profiles of the concentrations and temperatures of molecular oxygen in a candle flame and in a solid fuel (cellulose sheet) system. The required sensitivity for detecting oxygen is achieved by the use of high frequency wavelength modulation spectroscopy (WMS). Measurements will be performed in the NASA Lewis 2.2-second Drop Tower Facility. The objective of this research is twofold. First, we want to develop a better understanding of the relative roles of diffusion and reaction of oxygen in microgravity combustion. As the primary oxidizer species, oxygen plays a major role in controlling the observed properties of flames, including flame front speed (in solid or liquid flames), extinguishment characteristics, flame size, and flame temperature. The second objective is to develop better diagnostics based on diode laser absorption which can be of real value in microgravity combustion research. We will also demonstrate diode lasers' potential usefulness for compact, intrinsically-safe monitoring sensors aboard spacecraft. Such sensors could be used to monitor any of the major cabin gases as well as important pollutants.

Silver, Joel A.↗

Fabrication of a novel gigabit/second free-space optical interconnect - photodetector characterization and testing and system development

The time when computing power is limited by the copper wire inherent in the computer system and not the speed of the microprocessor is rapidly approaching. With constant advances in computer technology, many researchers believe that in only a few years, optical interconnects will begin to replace copper wires in your Central Processing Unit (CPU). On a more macroscopic scale, the telecommunications industry has already made the switch to optical data transmission as, to date, fiber optic technology is the only reasonable method of reliable, long range data transmission. Within the span of a decade, we will see optical technologies move from the macroscopic world of the telecommunications industry to the microscopic world of the computer chip. Already, the communications industry is marketing commercially available optical links to connect two personal computers, thereby eliminating the need for standard and comparatively slow wired and wireless Ethernet transfers and greatly increasing the distance the computers can be separated. As processing demands continue to increase, the realm of optical communications will continue to move closer to the microprocessor and quite possibly onto the microprocessor itself. A day may come when copper connections are used only to supply power, not transfer data. This summer s work marks some of the beginning stages of a 5 to 10 year, long-term research project to create and study a free-space, 1 Gigabit/sec optical interconnect. The research will result in a novel fabricated, chip-to-chip interconnect consisting of a Vertical Cavity Surface Emitting Laser (VCSEL) Diode linked through free space to a Metal- Semiconductor-Metal (MSM) Photodetector with the possible integration of microlenses for signal focusing and Micro-Electromechanical Systems (MEMS) devices for optical signal steering. The advantages, disadvantages, and practicality of incorporating flip-chip mounting technologies will also be addressed. My work began with the design and construction of a test setup for the experiment and then appropriate characterization of the test system. Specifically, I am involved in the characterization of a commercially available 1550nm wavelength, 5mW diode laser and a study of its modulation bandwidth. Commercially produced photodetectors as well as the incorporation of microwave technology, in the form of RF input and output, are used in the characterization procedure. The next stage involves the use of a probe station and network analyzer to characterize and test a series of photodetectors fabricated on a 2 inch, Indium Gallium Arsenide (InGaAs) wafer in the Branch s microlithography lab. Other project responsibilities include, but are not limited to the incorporation of a transimpedance amplifier to the photodetector circuit; a study of VCSEL technology; bit error rate analysis of an optical interconnect system; and analysis of free space divergence of the VCSEL, optical path length of the interconnect; and any other pertinent optical properties of the one gigabit per second interconnect for fabrication and testing.

Savich, Gregory R.↗

Three years of observations from the International Space Station (ISS) by the Stratospheric Aerosol and Gas Experiment III (SAGE III/ISS)

After completion of the robot installation on the International Space Station (ISS) in early March 2017 as an external hosted science payload, the Stratospheric Aerosol and Gas Experiment (SAGE) III became the newest member to the family of space-based solar occultation instruments operated by NASA to investigate the Earth’s upper atmosphere since the late 1970s. One of three identical instruments, the SAGE III/ISS mission was revived in the early 2010s with a primary objective to monitor the vertical distribution of aerosol, ozone and other trace gases to enhance understanding of ozone recovery and climate change processes in the upper atmosphere. Presented here is the mission architecture, its implementation, and data produced by SAGE III/ISS, including their precision and coverage. The 51.6-degree inclined orbit of the ISS is well-suited for solar occultation and provides near-global observations on a monthly basis with coverage of low and mid-latitudes similar to that of the SAGE II mission, which operated over two decades. The nominal science products, derived from sampling spectra covering 290nm to 1030nm and a photo-diode near 1550 nm, include high resolution vertical profiles of ozone, nitrogen dioxide and water vapor, along with multi-wavelength aerosol extinction. Although in the visible portion of the spectrum the brightness of the Sun is a million times that of the full Moon, the SAGE III instrument design covers this large dynamic range, performing lunar occultations on a routine basis to augment the solar products. The standard lunar products include ozone and nitrogen trioxide. Routine observations began June 2017 and continue to the present. This has enabled observations of significant perturbations of the stratosphere induced by three different wildfire events (two of which were record setting), four volcanic eruptions and two changes of the Quasi-Biennial Oscillation (QBO) phase, as represented in the standard data products.

ozone↗

Method for Measuring Collimator-Pointing Sensitivity to Temperature Changes

For a variety of applications, it is important to measure the sensitivity of the pointing of a beam emerging from a collimator, as a function of temperature changes. A straightforward method for carrying out this measurement is based on using interferometry for monitoring the changes in beam pointing, which presents its own problems. The added temperature dependence and complexity issues relating to using an interferometer are addressed by not using an interferometer in the first place. Instead, the collimator is made part of an arrangement that uses a minimum number of low-cost, off-the-shelf materials and by using a quad diode to measure changes in beam pointing. In order to minimize the influence of the test arrangement on the outcome of the measurement, several steps are taken. The collimator assembly is placed on top of a vertical, 1-m-long, fused silica tube. The quad diode is bonded to a fused silica bar, which, in turn, is bonded to the lower end of the fused silica tube. The lower end of the tube rests on a self-aligning support piece, while the upper end of the tube is kept against two rounded setscrew tips, using a soft rubber string. This ensures that very little stress is applied to the tube as the support structure changes dimensions due to thermal expansion. Light is delivered to the collimator through a bare fiber in order to minimize variable bending torque caused by a randomly relaxing, rigid fiber jacket. In order to separate the effect of temperature on the collimator assembly from the effect temperature has on the rest of the setup, multiple measurements are taken with the collimator assembly rotated from measurement to measurement. Laboratory testing, with 1-m spacing between the collimator and the quad diode, has shown that the sensitivity of the arrangement is better than 100 nm rms, over time spans of at least one hour, if the beam path is protected from atmospheric turbulence by a tube. The equivalent sensitivity to detecting changes in pointing angle is 100 nanoradians.

Abramovici, Alex↗

Column measurements of stratospheric trace species over Are, Sweden in the winter of 1991-1992

Total vertical column amounts of stratospheric HCl, HF, ClONO2 and HNO3 are reported from high resolution infrared solar absorption spectra taken during the European Arctic Stratospheric Ozone Experiment (EASOE) in the winter of 1991-1992. These ground based measurements were made near Are in North Sweden (63.4 deg N, 13.1 deg E) at an altitude of 800 m using a Fourier transform spectrometer and tunable diode laser heterodyne spectrometer. On 9th January 1992 the HCl vertical column dropped to 1.2 x 10(exp 15) molecules/sq cm from a November average of 3.6 x 10(exp 15) molecules/sq cm. The HCl drop occurred at a time when Are was below the polar vortex and the lower stratospheric ClO column above Are was elevated to approximately 2 x 10(exp 15) molecules/sq cm as measured by the Microwave Limb Sounder experiment on the Upper Atmosphere Research Satellite. These measurements indicate conversion of lower stratospheric chlorine from reservoir to chemically active forms.

Bell, W.↗

The laser heterodyne spectrometer - New sensor for the 80's

The paper deals with the basic concepts in optical heterodyne receivers with tunable diode lasers, operating in the thermal infrared. Simulation retrievals of vertical profiles of trace atmospheric gas species are carried out on the basis of heterodyne receiver performance parameters. Operational tests show a high signal-to-noise ratio in measuring gas absorption features. The results demonstrate the potential power of optical heterodyne receivers, and it is concluded that during the eighties they will become the major tool for measuring the earth's atmosphere and other planetary atmospheres.

Katzberg, S. J.↗

Integrating IR detector imaging systems

An integrating IR detector array for imaging is provided in a hybrid circuit with InSb mesa diodes in a linear array, a single J-FET preamplifier for readout, and a silicon integrated circuit multiplexer. Thin film conductors in a fan out pattern deposited on an Al2O3 substrate connect the diodes to the multiplexer, and thick film conductors also connect the reset switch and preamplifier to the multiplexer. Two phase clock pulses are applied with a logic return signal to the multiplexer through triax comprised of three thin film conductors deposited between layers. A lens focuses a scanned image onto the diode array for horizontal read out while a scanning mirror provides vertical scan.

Bailey, G. C.↗

Tropospheric Methane Over the Pacific Basin During TRACE-P

We received funding for the acquisition, statistical analysis, interpretation, and publication of atmospheric methane data collected during the Transport and Chemical Evolution over the Pacific (TRACE-P) mission, flown February through April of 2001. These high precision measurements were made aboard the NASA DC-8 and P-3B aircraft using a fast response, tunable diode laser system, the DACOM instrument. Our analysis focused on the vertical and geographical distribution of this key trace gas, particularly in the context of other data available from the region such as those from the Pacific NOAA CMDL surface sites, and earlier NASA aircraft missions (such as PEM-West A and B). The paper reporting these results, "Large-Scale Distribution of CH4 in the Western Pacific: Sources and Transport from the Asian Continent" by authors K.B. Bartlett, G.W. Sachse, T. Slate, C. Harward, and D.R. Blake, is attached. The dataset of roughly 13,800 CH4 measurements ranged between 1602 ppb in stratospherically impacted air and 2149 ppb in highly polluted air. Overall, we found that CH4 concentrations were highly correlated with trace gases characteristic of a mix of anthropogenic industrial and combustion sources. They were strikingly correlated with ethane (C2H6) in particular, whose major sources are natural gas leakage and biomass burning. Correlation between the two hydrocarbons indicated that these sources may dominate for CH4 as well at this time.

Bartlett, Karen B.↗

A Nanoscale Vacuum Field Emission Gated Diode with an Umbrella Cathode

A nanoscale field emission vacuum channel gated diode structure is proposed and a tungsten cathode with an umbrella-like geometry and sharp vertical edge is fabricated. The edge of the suspended cathode becomes the field emission surface. Unlike in the traditional transistor with the gate typically located between the source and the drain, the bottom silicon plate becomes the gate here and the anode terminal is located between the umbrella cathode and the gate. The fabricated devices show excellent diode characteristics and the gated diode structure is attractive for extremely low gate leakage.

Vacuum field emission diode↗

An experiment in manipulator control with proximity sensors

Optical proximity sensors were used in a feedback loop to automatically position a manipulator hand for grasping. The experiment was a simplified one, involving two dimensional motion only. Two proximity sensors were mounted on the hand, and control signals derived from their outputs were used to drive the hand vertically and horizontally. The sensors employ a pulsed gallium arsenide light-emitting diode together with a silicon detector. They indicate, without contact, the approximate distance between the manipulator hand and object in the range from 5 to 12 cm. Positioning within approximately + or - 5 mm was observed. Extension of the technique to general three-dimensional control is briefly discussed.

Johnston, A. R.↗