Search NASA⌕ Search

SEARCH · Search NASA

Results for “vertical stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A NASTRAN model of a large flexible swing-wing bomber. Volume 2: NASTRAN model development-horizontal stabilzer, vertical stabilizer and nacelle structures

The NASTRAN model plans for the horizontal stabilizer, vertical stabilizer, and nacelle structure were expanded in detail to generate the NASTRAN model for each of these substructures. The grid point coordinates were coded for each element. The material properties and sizing data for each element were specified. Each substructure model was thoroughly checked out for continuity, connectivity, and constraints. These substructures were processed for structural influence coefficients (SIC) point loadings and the deflections were compared to those computed for the aircraft detail models. Finally, a demonstration and validation processing of these substructures was accomplished using the NASTRAN finite element program installed at NASA/DFRC facility.

Mock, W. D.↗

Assessment of vertical stability for negative triangularity pilot plants

Abstract Negative triangularity (NT) tokamak configurations may be more susceptible to magneto-hydrodynamic instability, posing challenges for recent reactor designs centered around their favorable properties, such as improved confinement and operation free of edge-localized modes. In this work, we assess the vertical stability of plasmas with NT shaping and develop potential reactor solutions. When coupled with a conformal wall, NT equilibria are confirmed to be less vertically stable than equivalent positive triangularity (PT) configurations. Unlike PT, their vertical stability is degraded at higher poloidal beta. Furthermore, improvements in vertical stability at low aspect ratio do not translate to the NT geometry. NT equilibria are stabilized in PT vacuum vessels due to the increased proximity of the plasma and the wall on the outboard side, but this scenario is found to be undesirable due to reduced vertical gaps which give less spatial margin for control recovery. Instead, we demonstrate that informed positioning of passively conducting plates can lead to improved vertical stability in NT configurations on par with stability metrics expected in PT scenarios. An optimal setup for passive plates in highly elongated NT devices is presented, where plates on the outboard side of the device reduce vertical instability growth rates to 16% of their baseline value. For lower target elongations, integration of passive stabilizers with divertor concepts can lead to significant improvements in vertical stability. Plates on the inboard side of the device are also uniquely enabled in NT geometries, providing opportunity for spatial separation of vertical stability coils and passive stabilizers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of tokamak vertical stability control based on non-inductive Faraday-effect polarimetry measurements

Long-pulse or steady-state fusion reactors are envisioned to control vertical stability based on non-inductive measurements, i.e. that do not rely on temporal change of magnetic field. For the first time, vertical stability control using non-inductive Faraday-effect polarimetry measurements has been demonstrated. The Radial Interferometer-Polarimeter system on DIII-D is capable of microsecond resolution and was used to absolutely determine the vertical position of the plasma magnetic axis Z 0 . A vertical stability controller was developed to robustly stabilize diverted plasmas using Faraday-based measurements. The system was able to stabilize against vertical displacement events with growth rates up to 350 s -1 in elongated and elliptical plasma shapes, and instabilities with even higher growth rates are likely to be controllable with further improvements to controller tuning. Tests show that the Faraday-based controller remains effective and is capable of recovering from loss of control even when the plasma vertical position is far from the region where the linear model used to calculate Z 0 is most valid. Faraday control has also been activated during plasma ramp-up, demonstrating the robustness of the technique to larger systematic diagnostic uncertainty at low electron density.

Faraday-effect polarimetry↗

Materials Examination of the Vertical Stabilizer from American Airlines Flight 587

The first in-flight failure of a primary structural component made from composite material on a commercial airplane led to the crash of American Airlines Flight 587. As part of the National Transportation Safety Board investigation of the accident, the composite materials of the vertical stabilizer were tested, microstructure was analyzed, and fractured composite lugs that attached the vertical stabilizer to the aircraft tail were examined. In this paper the materials testing and analysis is presented, composite fractures are described, and the resulting clues to the failure events are discussed.

Fox, Matthew R.↗

Advanced composite vertical stabilizer for DC-10 transport aircraft

The structural design configuration for the Composite Vertical Stabilizer is described and the structural design, analysis, and weight activities are presented. The status of fabrication and test activities for the development test portion of the program is described. Test results are presented for the skin panels, spar web, spar cap to cover, and laminate properties specimens. Engineering drawings of vertification test panels and root fittings, rudder support specimens, titanium fittings, and rear spar specimen analysis models are included.

Stephens, C. O.↗

A data-driven approach to real-time vertical position estimation for NSTX-U vertical stability control

In this paper, a database of 77 996 plasma equilibrium reconstructions from 727 discharges during the initial operation of the NSTX-U spherical tokamak is analyzed to develop a statistically robust model of the plasma vertical position for real-time control. A variety of regression models are developed and tested, ranging in complexity from linear models to deep neural networks, and including input signals ranging from the four pairs of flux loops used historically on NSTX-U up to the full set of 389 real-time signals available to the plasma control system. A linear model based on 140 real-time magnetics signals is found to offer excellent accuracy, with a coefficient of determination R 2 = 0.906. The robustness of this model to limited training data, new operating scenarios, and signal errors is tested, and a procedure is demonstrated to tune the model parameters to optimize its robustness. A time-dependent plasma equilibrium solver, TokaMaker, is used to simulate vertical stability control in NSTX-U, demonstrating that it should be possible to iteratively tune the parameters of a linear vertical position model to stabilize both positive and negative triangularity plasmas in future experiments.

magnetic diagnostics↗

Advanced composite vertical stabilizer for DC-10 transport aircraft

Structural design, tooling, fabrication, and test activities are reported for a program to develop an advanced composite vertical stabilizer (CVS) for the DC 10 Commercial Transport Aircraft. Structural design details are described and the status of structural and weight analyses are reported. A structural weight reduction of 21.7% is currently predicted. Test results are discussed for sine wave stiffened shear webs containing representative of the CVS spar webs and for lightning current transfer and tests on a panel representative of the CVS skins.

Stephens, C. O.↗

Fractographic Examination of the Vertical Stabilizer and Rudder from American Airlines Flight 587

The first major structural component failure of a composite part on a commercial airplane occurred during the crash of American Airlines Flight 587. The fractured composite lugs that attached the vertical stabilizer to the aircraft tail and the fractured composite honeycomb rudder were examined as part of the National Transportation Safety Board investigation of the accident. In this paper the composite fractures are described and the resulting clues to the failure events are discussed.

Fox, Matthew R.↗

Forebody and vertical stabilizer effects on directional stability of a reusable LOX/RP (061) booster AR 12161-2

Results are presented of a wind tunnel test on the directional stability of space shuttle booster configurations. The test was conducted at the 14-inch trisonic tunnel starting 6 December 1971 and continued through 11 December 1971 for a total of 66 occupancy hours. Configurations tested included a cylindrical body with two axisymmetrical noses, one with and without canopy, one delta wing, located in two positions, five vertical tails (including a V tail), two having split rudders, ventral fins, two sets of chines, three airbreathing engine pods, and rocket engine shrouds. The model scale was 0.003366.

Roth, C. E.↗

DC-10 composite vertical stabilizer ground test program

A review of the structural configuration and ground test program is presented. Particular emphasis is placed on the testing of a full-scale stub box test subcomponent and full span ground test unit. The stub box subcomponent was tested in an environmental chamber under ambient, cold/wet, and hot/wet conditions. The test program included design limit static loads, fatigue spectrum loading to approximately two service lifetimes (with and without damage), design limit damage tolerance tests, and a final residual strength test to a structural failure. The first full-scale ground test unit was tested under ambient conditions. The test unit was to have undergone static, fatigue, and damage tolerance tests but a premature structural failure occurred at design limit load during the third limit load test. A failure theory was developed which explains the similarity in types of failure and the large load discrepancy at failure between the two test articles. The theory attributes both failures to high stress concentrations at the edge of the lower rear spar access opening. A second full-scale ground test unit has been modified to incorporate the various changes resulting from the premature failure. The article has been assembled and is active in the test program.

Palmer, J. M., Jr.↗

Real-time observation of toroidal current redistributions induced by three-dimensional MHD phenomena triggering vertical displacement events in tokamak plasmas

Three-dimensional MHD instabilities, including edge-localized modes (ELMs) and internal reconnection events (IREs), have been observed to precipitate loss of vertical stability in tokamak plasmas, resulting in vertical displacement events (VDEs). This vertical destabilization can occur due to toroidal current redistributions and/or shape changes resulting from these phenomena. Using a recently introduced method for rapidly reconstructing the two-dimensional toroidal plasma current density profile in real-time, results are presented that demonstrate the specific current distribution changes that occur during ELMs (on KSTAR) and IREs (on MAST-U) that lead to loss of vertical control. The method most efficiently reconstructs the toroidal current density profile by doing so on a basis of principal components of historical profiles. These principal components isolate dominant current profile dynamics, improving interpretability, increasing speed, and reducing dimensionality of the profile computation. On KSTAR, this computation is executed in the real-time plasma control system at a rate of 10 kHz (limited by available CPU cycle times), allowing the current profile evolution to be assessed at several times over the course of each ELM event. Further, by incorporating the reconstructions into a novel vertical stability metric, the contribution of specific current profile dynamics to the loss of vertical stability can be assessed in real-time for VDE avoidance and improved understanding of the causal relationship between three-dimensional MHD phenomena and VDEs. The success of this method in approximating toroidal current density profiles from kinetic equilibrium reconstructions is also presented ($R^2=0.990$), along with its capability to produce other equilibrium quantities of interest in real-time at high time resolution.

edge-localized modes↗

Design and fabrication of instrumented composite airfoils for a cryogenic wind tunnel model

Two instrumented horizontal stabilizers and one instrumented vertical stabilizer were designed and fabricated for testing on the Pathfinder 1 (PF-1) Transport Model in the NASA Langley Research Center's National Transonic Facility (NTF). Two different designs were employed: the horizontal stabilizer utilized a metal spar and fiberglass overwrap and the vertical stabilizer was made of all fiberglass. All design requirements were met in terms of design loads, airfoil tolerances, surface finish, orifice hole quality, and proof-of-concept tests. Pressure tubing installation was found to be easier for these concepts as compared to methods used in conventional metallic models. Ease of repair was found to be a principal advantage in that some fabrication problems were overcome by reapplying fiberglass cloth and/or epoxy to damaged areas. Also, fabrication costs were judged to be lower when compared to the more conventional design fabrication costs.

Young, Clarence P., Jr.↗

Determination of Functional Capabilities, the Level of Physical Performance and the State of Main Physiological Body Systems in the First Hours after the Accomplishment of Long-term Space Flights ("Field Test")

Long-term stay in weightlessness is accompanied by alterations in the activity of main physiological body systems including sensory-motor, skeletal-muscular disturbances and cardiovascular deconditioning. However, up to now, there are no data on the state and level of functional performance of cosmonauts/astronauts directly after flight, nor are there data to help define the dynamic recovery of functional characteristics and work efficiency which are greatly needed to provide the safety and planning of their activity once they reach space objects. The Russian and American scientists are currently engaged in a joint experiment known as the "Field Test" with the goal of studying the functional performance and the state of main physiological body systems directly after landing and their temporal recovery dynamics. The functional performance is identified during the test by temporal characteristics of the movements of spatial translation, the stability of the vertical stance for 3.5 min, and the kinematic characteristics of walking - non-complicated and complicated. The following characteristics are identified as physiological characteristics of the test: a) orthostatic tolerance during stand test, b) back muscle tone; c) vertical stability - by characteristics of the correction responses to unexpected perturbations of the vertical stance, and d) support reactions during the performance of the full battery of tests. To date, a pilot version of the "Field Test" has been conducted with participation from four Russian cosmonauts. The results of studies have shown that in 1 - 5 hours after landing the functional abilities of the cosmonauts are considerably reduced. All the test movements at this time are considerably slower than preflight and the more complicated the task is, the greater significant reduction in orthostatic tolerance: during the first test that occurs 1 - 5 hours after landing. two of four cosmonauts declined to continue the task after the orthostatic test (one of them did not wear the anti-G suit "Centaurus" during testing). Blood pressure during moving out of prone posture to vertical stance in one of the cosmonauts and of sitting to standing position in the other dropped to the precollapse level. The results of the studies have confirmed the feasibility, the usefulness and the safety of conducting tests as close as possible to the landing. The program of "Field Test" experiment will be continued and extended.

Kozlovskaya, Inesa↗

Stripe stabilization in vertical Bloch line memory

Long, partial rectangular grooves have been made to reside below the stripe-confinement groove on a garnet surface, in order to stabilize minor loop stripes in a vertical Bloch-line memory. The test chip contained, in addition to either 10 or 20 minor-loop grooves, 10 read/write gate grooves and a major line groove; both 10 and 20 micron groove periods were tested. As the bias field was gradually decreased, bubbles began to stripe out. These stripes were stable at bias fields in the 70-80 Oe range. When stripes escaped from the groove, the even occurred from the end which does not face a read/write gate groove.

Wu, J. C.↗

Phytoplankton standing crops within an Antarctic ice edge assessed by satellite remote sensing

The dynamic interactions between the pack-ice recession and the occurrence of ice blooms of phytoplankton in waters of the marginal ice zone within an Antarctic ice edge were investigated using CZCS and SMMR imageries from the Nimbus 7 satellite (September 16-December 17, 1983), together with in situ measurements of pigments and sea ice concentration carried out from November 7 to December 2. A substantial amount of spatial variability in pigment concentration was observed to occur along the ice edge in the Weddell Sea. The relationships among light, ice distribution, and vertical stability and their effects on observed spatial variations in phytoplankton biomass are discussed. The results of this investigation suggest that the retreat of ice provides an input of significant volumes of meltwater which creates vertical stability for a period necessary to permit growth and accumulation of phytoplankton.

Sullivan, C. W.↗

Point Defect Distributions in ZnSe Crystals: Effects of Gravity Vector Orientation during Physical Vapor Transport Growth

ZnSe crystals were grown by the physical vapor transport technique under horizontal and vertical (stabilized and destabilized) configurations. Secondary ion mass spectroscopy and photoluminescence measurements were performed on the ZnSe samples to map the distributions of [Si], [Fe], [Cu], [Al] and [Li or Na] impurities as well as Zn vacancy, [V(zn)]. The annealings of ZnSe under controlled Zn pressures were studied to correlate the measured photoluminescence emission intensity to the equilibrium Zn partial pressure. In the horizontal grown crystals the segregations of [Si], [Fe], [Al] and [V(zn)] along the gravity vector direction were observed whereas in the vertically stabilized grown crystal the segregations of these point defects were radially symmetrical. No apparent pattern was observed on the measured distributions in the vertically destabilized grown crystal. The observed segregations in the three growth configurations were interpreted based on the possible buoyancy-driven convection in the vapor phase.

Su, Ching-Hua↗