Search NASA⌕ Search

SEARCH · Search NASA

Results for “vibration of cracked MEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Nonlinear modeling and performance analysis of cracked beam microgyroscopes

Cracks constitute a common structural defect in microelectromechanical systems that may arise during manufacturing, mechanical fatigue, or shock loading. Areas weakened by cracks increase the flexibility of the microstructure. Furthermore, depending on the crack severity, the increased flexibility can cause dramatic changes in the static and dynamic behaviors of electrically actuated MEMS. In this study, a numerical investigation of the depth and location of multiple edge cracks on the performance of beam microgyroscopes is conducted. Applying the Griffith strain energy release theorem for an edge crack, the vibrational characteristics of microgyroscopes with multiple cracks including the static deflection, natural frequencies, and mode shapes are studied analytically. Then, the differential quadrature method is employed to model the nonlinear dynamic behaviors of the cracked gyroscope system. Cracks initiated along the driving or sensing directions of the microgyroscope are found to have differing effects on its nonlinear dynamic response. This numerical study reveals that the onset of severe single cracks or a series of multiple cracks can significantly affect the sensitivity of the microgyroscope to base rotations and therefore leads to a degradation in the performance of the damaged MEMS sensor. This study also shows that a potential design approach for broadband microgyroscope systems manufactured with cracks can be proposed.

42 ENGINEERING↗

Vibration-based health characterization of multiple IMUs in UAV applications

Inertial measurement units (IMUs) are vital in UAV navigation for vehicle attitude and position estimation, especially in the frequently-occurring case of temporary loss of GPS capabilities. Degradation in these units could yield inaccurate position estimates, resulting in incorrect input for vehicle control systems. A wide variety of these units exist to meet the needs of UAV operators, general aviation, and military vehicles. In recent decades, lightweight and inexpensive MEMS sensors have grown in popularity with respect to UAVs. Studies into the failure modes of MEMS devices suggest that vibration is one of the leading causes of MEMS degradation. MEMS sensors are generally encased in their own hermetic packaging, as their small size and sensitivity cause them to be particularly vulnerable to air damping and particulate contamination when exposed. Exposure to excessive vibration can cause cracking in this packaging as well as damage to connecting electronics, with recorded results that cause sensors to act outside of their specifications, potentially providing unreliable input to controllers. A prior study from the Politecnico di Torino looked into the degradation of MEMS IMUs, specifically the AXIS-AIS402, for aerospace and vibrating environments. In the study, the authors found that after exposing MEMS IMUs to simulated vibrations from working conditions of aerospace applications, the sensors showed increased noise and increased bias instability. At NASA Ames, several widely-used MEMS IMUs were selected for a new IMU degradation study, comparing accelerometer performance before and after exposure to similar levels of vibration simulating aerospace conditions. The IMUs were selected from the Pixhawk autopilot systems, hobby sUAS, or prior experimental studies at NASA. Additionally, the industrial grade VectorNav-100 IMU was selected as a ground truth reference point to which the performance of the test sensors can be compared. In the study, each sensor is exposed to functional levels of UAV vibration as replicated on a single-frequency vibratory table in the NASA Ames SHARP Laboratory, and each accelerometer is characterized for bias, drift, and noise characteristics both before and after vibratory exposure. The focus of this study is to monitor the health of the IMU sensors and determine if sensor degradation can be detected from output error and frequency spectrum analysis, rather than from microscopic examination of the sensors. In this case, sensor degradation and faulty data can be more easily detectable by non-experts hoping to use these sensors as an important piece of an integrated package. In addition, specific sensor degradation modes potentially leading to in-flight hazards could be identified, such as accelerated levels of drift and altered temperature response. The overall goal of this work is to increase levels of safety for future users of these sensors and to provide a clear analysis of sensor limitations currently lacking in most sensor specification documentation.

IMUs↗

Evaluation of MEMS-Based Wireless Accelerometer Sensors in Detecting Gear Tooth Faults in Helicopter Transmissions

The diagnostics capability of micro-electro-mechanical systems (MEMS) based rotating accelerometer sensors in detecting gear tooth crack failures in helicopter main-rotor transmissions was evaluated. MEMS sensors were installed on a pre-notched OH-58C spiral-bevel pinion gear. Endurance tests were performed and the gear was run to tooth fracture failure. Results from the MEMS sensor were compared to conventional accelerometers mounted on the transmission housing. Most of the four stationary accelerometers mounted on the gear box housing and most of the CI's used gave indications of failure at the end of the test. The MEMS system performed well and lasted the entire test. All MEMS accelerometers gave an indication of failure at the end of the test. The MEMS systems performed as well, if not better, than the stationary accelerometers mounted on the gear box housing with regards to gear tooth fault detection. For both the MEMS sensors and stationary sensors, the fault detection time was not much sooner than the actual tooth fracture time. The MEMS sensor spectrum data showed large first order shaft frequency sidebands due to the measurement rotating frame of reference. The method of constructing a pseudo tach signal from periodic characteristics of the vibration data was successful in deriving a TSA signal without an actual tach and proved as an effective way to improve fault detection for the MEMS.

gears↗

Performance of multifunctional piezoelectric energy harvesting microgyroscopes with material degradation

Most microelectromechanical systems (MEMS) are made from brittle materials that are prone to cracking. Damage from the formation of cracks can occur anytime during the manufacturing process or due to mechanical loading of MEMS devices. Cracks can increase the structures flexibility and lead to changes in performance or total failure. Understanding the potential influences cracks in MEMS is necessary for the longevity of these systems. The energy harvesting microgyroscope studied in this work is susceptible to crack propagation in its silicon substrate and lead zirconate titanate piezoelectric patch. To this end, an electromechanical model is developed to capture the impacts of cracks on the performance of a damaged energy harvesting microgyroscope. Numerical methods are used to approximate the damage associated with distributed crack networks. Then, the static and dynamic responses of the damaged microgyroscope are analyzed for two possible multifunctional setups. Here, the current study revealed that cracks can significantly affect the static and dynamic behaviors of the microgyroscope energy harvester. Combinations of cracking and piezoelectric property degradation cause a decrease in the static pull-in voltage and shift the resonance frequencies of the system. Additionally, it is shown that the systems sensitivity to changes in the base rotation and energy harvesting capabilities vary widely depending on the severity of material degradation.

36 MATERIALS SCIENCE↗