Search NASA⌕ Search

SEARCH · Search NASA

Results for “virucidal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Antiviral discovery using sparse datasets by integrating experiments, molecular simulations, and machine learning

Computational methods have demonstrated success in identifying virucidal agents, effectively contributing to the discovery of novel virucidal molecules. In this study, we developed a machine learning (ML) model, trained on a small dataset, to predict inhibitors of human enterovirus 71 (EV71), a pathological agent that causes severe disease in children and immunocompromised adults. Despite the dataset’s limitation, comprising of only 36 compounds tested, our ML framework demonstrated significant predictive capability. Notably, experimental validation revealed that five out of the eight compounds predicted by our model from the Chinese cosmetic material list exhibited virucidal activity. The inhibitor effects displayed by the main active compounds were further confirmed by molecular dynamics simulation. This underscores the potential of our AI-driven approach to bypass data constraints in identifying active molecules against viral pathogens.

60 APPLIED LIFE SCIENCES↗

Ozone Gas: Scientific Justification and Practical Guidelines for Improvised Disinfection using Consumer-Grade Ozone Generators and Plastic Storage Boxes

Here, we describe direct measurements of ozone concentration achievable in small enclosed containers (plastic storage boxes) for use as improvised decontamination systems for small articles such as disposable PPE (N95 masks, nitrile gloves, etc.), clothing, mail and small packages, food, and other miscellaneous articles. The emphasis is on the reliable and sustained generation of ozone gas concentrations of sufficient concentration and duration to create an effective virucidal environment to achieve more than 95% to 99% viral inactivation, based upon the data already published in the peer-review literature on this topic. The suggestion that ozone be used to inactivate virus is certainly not a new idea. Our objective in this report is to make clear that the necessary levels of ozone can be improvised using simple, easy-to-use, inexpensive, and widely available supplies, and that there is every theoretical and experimental reason to believe that this approach is as highly effective in viral inactivation by ozone as are the far more expensive, complex, cumbersome, and less available equivalent ozone (and other) disinfectant systems that have themselves become unavailable during times of pandemic crisis. Using multiple types of readily available commercial ozone generators, concentration in the tested improvised enclosure is tracked over time to assess ozone charging and decay rates, and the ozone quenching effects of items placed in the box. Generator performance is compared against published ozone dosage values for virucidal and antimicrobial activity. Bubbler and box-fan-type ozone generators were found to be effective at achieving and maintaining target concentrations of 10ppm ozone or higher, whereas automotive cigarette lighter and universal serial bus type plug in “air freshener” ozone generators could not achieve the target concentrations in these experiments. Calculations and practical guidelines for assembly and effective use of an ozone box for improvised decontamination are offered. The majority of this report is directed toward the scientific justification and rationale for this approach. The end of the document summarizes the findings and offers simplified designs for the construction and use of ozone boxes as an improvised method of disinfection.

60 APPLIED LIFE SCIENCES↗

Durability of Disposable N95 Mask Material When Exposed to Improvised Ozone Gas Disinfection

The principle finding of this report is that both commercial and a novel material used for N95 mask filters can endure many cycles of disinfection by ozone gas (20 ppm for 30 minutes) without detectable degradation or loss of filtration efficiency. N95 masks and surgical masks (hereafter referred to as masks) typically use a filtration material fabricated from meltblown polypropylene. To achieve maximum filtration efficiency while maintaining a reasonable pressure drop, these nonwoven fabrics are also electrostatically charged (corona discharge is the most common method used), to maximize attraction and capture of aerosols and solid particulates. Under normal circumstances, the reuse of masks is generally discouraged, but in times of crisis has become a necessity, making disinfection after each use a necessity. To be acceptable, any disinfection procedure must cause minimal degradation to the performance of the filter material. Possible performance degradation mechanisms include mechanical damage, loss of electrostatic charge, or both. One of the most practical and direct ways to measure combined mechanical and electrostatic integrity, and the subsequent ability to reuse mask filter material, is by the direct measurement of filtration efficiency. In this paper, we report that small numbers of disinfection cycles at reasonable virucidal doses of ozone do not significantly degrade the filtration efficiency of meltblown polypropylene filter material. By comparison, laundering quickly results in a significant loss of filtration efficiency and requires subsequent recharging to restore the electrostatic charge and filtration efficiency. A common assumption among biomedical scientists that ozone is far too destructive for this application. However, these direct measurements show that mask materials, specifically the filtration material, can withstand dozens of ozone disinfection cycles without any measurable degradation of filtration efficiency, nor any visible discoloration or loss of fiber integrity. The data are clear: when subjected to a virucidal dose of ozone for a much longer duration than is required for viral inactivation, there was no degradation of N95 filtration efficiency. The specific dosages of ozone needed for ~99% viral inactivation are thought to be at least 10 ppm for up to 30 minutes based upon an extensive literature review, but to standardize our testing, we consider a dose of 20 ppm for 30 minutes to be a reasonable and conservatively high ozone disinfection cycle. Finally, the material tested in this study withstood dosages of up to 200 ppm for 90 minutes, or alternatively 20 ppm for up to 36 hours, without detectable degradation, and further testing suggests that up to 30 or more disinfection cycles (at 20 ppm for 30 minutes) would result in less than a 5% loss of filtration efficiency. This report does not address the effect of ozone cycling on other mask components, such as elastics.

60 APPLIED LIFE SCIENCES↗

Decontamination and Sterilization of Surfaces using Low Cost Ionic Liquids (CRADA Final Report)

The current study made a comprehensive literature review of the structure activity relationship (SAR) for microcidal and virucidal influence of ionic liquids. It summarized the key structure parameters that have close correlation to the antimicrobial and antiviral properties of the ILs. It proposed an experimental plan on developing and testing an effective ionic liquid from renewable lignocellulosic biomass. The goal is to understand the structure activity relationship (SAR) for virucidal influence of ionic liquids through comprehensive literature search and data analysis. A full experimental plan will be drafted based on the literature summary. Perform a comprehensive literature search to aid the development of an effective and easily deployable method to inactivate SARS-CoV-2 and decontaminate surfaces based on low-cost functional ionic liquids. These designer solvents have the potential to be a compelling and environmentally friendly alternative to common chemical disinfectants. Literature summary report including reported ionic liquid structures, synthesis and testing methods, and the structure activity relationship. Experimental plan on developing a low cost effective antiviral ionic liquid.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation and optimization for the decontamination/sterilization of personal protective equipment using a novel ozone chamber (CRADA Final Report)

Personal protective equipment slows the spread of the SARS-Cov-2 virus and protects first responders and the general population. However, there is a significant and well-publicized shortage of personal protective equipment for healthcare workers. Treatment with ozone may be a compelling, affordable, and scalable method to rapidly decontaminate personal protective equipment but more work is needed to verify these claims. Together with colleagues at the University of Nevada Reno and FATHHOME we helped design the experiments that evaluated the virucidal efficacy of FATHHOME’s device on N95 face masks and face shields. The results of our study were published in the journal Pathogens.

60 APPLIED LIFE SCIENCES↗

Inactivation of Human Coronavirus by FATHHOME’s Dry Sanitizer Device: Rapid and Eco-Friendly Ozone-Based Disinfection of SARS-CoV-2

The pandemic of SARS-CoV-2/COVID-19 was reported in December 2019 in Wuhan, China. Pertaining to its high transmissibility and wide host adaptability, this unique human coronavirus spread across the planet inflicting 115 million people and causing 2.5 million deaths (as of March 3rd, 2021). Limited or negligible pre-existing immunity to multiple SARS-CoV-2 variants has resulted in severe morbidity and mortality worldwide, as well as a record-breaking surge in the use of medical-surgical supplies and personal protective equipment. In response to the global need for effective sterilization techniques, this study evaluated the virucidal efficacy of FATHHOME’s self-contained, ozone-based dry-sanitizing device, by dose and time response assessment. We tested inactivation of human coronavirus, HCoV-OC43, a close genetic model of SARS-CoV-2, on porous (N95 filtering facepiece respirator/FFR) and nonporous (glass) surfaces. We started our assays with 20 ppm-10 min ozone exposure, and effectively reduced 99.8% and 99.9% of virus from glass and N95 FFR surfaces, respectively. Importantly, the virus was completely inactivated, below the detection limit (over 6-log10 reduction) with 25 ppm-15 min ozone exposure on both tested surfaces. As expected, a higher ozone exposure (50 ppm-10 min) resulted in faster inactivation of HCoV-OC43 with 100% inactivation from both the surfaces, with no residual ozone present after completion of the 5-min post exposure recapture cycle and no measurable increase in ambient ozone levels. These results confirmed that FATHHOME’s device is suitable for rapid decontamination of SARS-CoV-2- from worn items, frequently touched items, and PPE including N95 FFRs, face shields, and other personal items. View Full-Text

59 BASIC BIOLOGICAL SCIENCES↗