The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10 kg of liquid argon. A dark-count characterization technique, which avoids the use of a single-photon source, was used at two temperatures to measure the VUV4 SiPMs breakdown voltage (V BD ), the SiPM gain (g SiPM ), the rate of change of g SiPM with respect to voltage (m), the dark count rate (DCR), and the probability of a correlated avalanche (P CA ) as well as the temperature coefficients of these parameters. A Peltier-based chilled vacuum chamber was developed at Queen's University to cool down the Quads to 233.15 ± 0.2 K and 255.15 ± 0.2 K with average stability of ±20 mK. An analysis framework was developed to estimate V BD to tens of mV precision and DCR close to Poissonian error. The temperature dependence of V BD was found to be 56 ± 2 mV K -1 , and m on average across all Quads was found to be (459 ± 3(stat.)±23(sys.))× 10 3 e- PE -1 V -1 . The average DCR temperature coefficient was estimated to be 0.099 ± 0.008 K -1 corresponding to a reduction factor of 7 for every 20 K drop in temperature. The average temperature dependence of P CA was estimated to be 4000 ± 1000 ppm K -1 . P CA estimated from the average across all SiPMs is a better estimator than the P CA calculated from individual SiPMs, for all of the other parameters, the opposite is true. All the estimated parameters were measured to the precision required for SBC-LAr10, and the Quads will be used in conditions to optimize the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat

CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of 100 Mo. It will operate at ~10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of 100 Mo-enriched Li 2 MoO 4 crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70–90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained high energy resolutions at the 356 keV line from a 133 Ba source, as good as Ge semiconductor γ detectors in this energy range.

47 OTHER INSTRUMENTATION↗

First results from a multiplexed and massive instrument with sub-electron noise Skipper-CCDs

Here, we present a new instrument composed of a large number of sub-electron noise Skipper-CCDs operated with a two stage analog multiplexed readout scheme suitable for scaling to thousands of channels. New, thick, 1.35 Mpix sensors, from a new foundry, are glued into a Multi-Chip Module (MCM) printed circuit board on a ceramic substrate which has 16 sensors each. The instrument, that can hold up-to 16 MCMs, a total of 256 Skipper-CCD sensors (called a Super-Module with ≈ 130 grams of active mass and 346 Mpix), is part of the R&D effort of the OSCURA experiment which will have ≈ 94 super-modules. Experimental results with 10 MCMs and 160 Skipper-CCDs sensors are presented in this paper. This is already the largest ever built instrument with single electron sensitivity CCDs using nondestructive readout, both, in terms of active mass and number of channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel imaging technique for thermal neutrons using a fast optical camera

A novel imaging technique for thermal neutrons using a fast optical camera is presented. Thermal neutrons are reacted with 6 Lithium to produce a pair of 2.73 MeV tritium and 2.05 MeV alpha particles, which in turn interact in a thin layer of LYSO crystal scintillator to produce a localized flash of light. These photons are directed by a pair of lenses to a micro-channel plate intensifier, and its output is connected to the optical camera, TPX3CAM. The results from the camera are reconstructed through a custom algorithm. Various cutting parameters were found through data analysis to eliminate the background, and they were shown effective in matching the simulated rate of the neutron source. The system is fast with 40 ns decay time and allows free-space light collection, both vastly enhances flexibility of neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, upgrade and characterization of the silicon photomultiplier front-end for the AMIGA detector at the Pierre Auger Observatory

AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to complement the study of ultra-high-energy cosmic rays (UHECR) by measuring the muon content of extensive air showers (EAS). It consists of an array of 61 water Cherenkov detectors on a denser spacing in combination with underground scintillation detectors used for muon density measurement. Each detector is composed of three scintillation modules, with 10 m 2 detection area per module, buried at 2.3 m depth, resulting in a total detection area of 30 m 2 . Silicon photomultiplier sensors (SiPM) measure the amount of scintillation light generated by charged particles traversing the modules. In this paper, the design of the front-end electronics to process the signals of those SiPMs and test results from the laboratory and from the Pierre Auger Observatory are described. Compared to our previous prototype, the new electronics shows a higher performance, higher efficiency and lower power consumption, and it has a new acquisition system with increased dynamic range that allows measurements closer to the shower core. The new acquisition system is based on the measurement of the total charge signal that the muonic component of the cosmic ray shower generates in the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel imaging technique for α-particles using a fast optical camera

A new imaging technique forα-particles using a fast optical camera focused on a thin scintillator is presented. Asα-particles interact in a thin layer of LYSO fast scintillator, they produce a localized flash of light. Furthermore, the light is collected with a lens to an intensified optical camera, Tpx3Cam, with single photon sensitivity and excellent spatial & temporal resolutions. The interactions of photons with the camera is reconstructed by means of a custom algorithm, capable of discriminating single photons using time and spatial information

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the underground muon detector of the Pierre Auger Observatory

To obtain direct measurements of the muon content of extensive air showers with energy above 10 16.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m 2 -modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m 2 close to the intersection of the shower axis with the ground to much less than one per m 2 when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The FRAM robotic telescope for atmospheric monitoring at the Pierre Auger Observatory

FRAM (F/Photometric Robotic Atmospheric Monitor) is a robotic telescope operated at the Pierre Auger Observatory in Argentina for the purposes of atmospheric monitoring using stellar photometry. As a passive system which does not produce any light that could interfere with the observations of the fluorescence telescopes of the observatory, it complements the active monitoring systems that use lasers. We discuss the applications of stellar photometry for atmospheric monitoring at optical observatories in general and the particular modes of operation employed by the Auger FRAM. We describe in detail the technical aspects of FRAM, the hardware and software requirements for a successful operation of a robotic telescope for such a purpose and their implementation within the FRAM system.

Optics↗

Test beam study of SiPM-on-tile configurations

Light yield and spatial uniformity for a large variety of configurations of scintillator tiles were studied. The light from each scintillator was collected by a Silicon Photomultiplier (SiPM) directly viewing the produced scintillation light (SiPM-on-tile technique). The varied parameters included tile transverse size, tile thickness, tile wrapping material, scintillator composition, and SiPM model. Furthermore, these studies were performed using 120 GeV protons at the Fermilab Test Beam Facility. External tracking allowed the position of each proton penetrating a tile to be measured. The results were compared to a GEANT4 simulation of each configuration of scinitillator, wrapping, and SiPM.

47 OTHER INSTRUMENTATION↗

Reflectivity of VUV-sensitive silicon photomultipliers in liquid Xenon

Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. Here, the reflectivity is determined to be 25–36 % at an angle of incidence of 20° for the four samples and increases to up to 65 % at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.

(pin diodes, APDs, SiPMs, G-APDs, CCDs, EBCCDs, EM↗

Signal formation and sharing in AC-LGADs using the ALTIROC 0 front-end chip

The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. However, finding a technology capable of fulfilling such aspiration proved to be an arduous task. Among other silicon-based candidates, the Low-Gain Avalanche Diode (LGAD) has already shown excellent timing performances but proved to be unsuitable for fine pixelization. Therefore, the AC-coupled LGAD (AC-LGAD) approach was introduced to provide high resolution in both time and space, making it a promising candidate for future 4D detectors. However, appropriate readout electronics must be developed to match the sensor's fast-time and fine-pitch capabilities. This is currently a major technological challenge. Here, we test AC-LGAD prototypes read out by the fast-time ASIC ALTIROC 0, originally developed for the readout of DC-coupled LGADs for the ATLAS experiment at the High Luminosity-LHC. Signal generated by either betas from a 90 Sr source or a focused infra-red laser were analyzed. This paper details the first successful readout of an AC-LGAD sensor using a readout chip. This result will pave the way for the design and construction of a new generation of AC-LGAD-based 4D detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies in pulse shape discrimination for an optimized ASIC design

The continued advancements of Silicon Photomultipliers (SiPMs) have made them viable photosensors for low recoil energy Pulse Shape Discrimination (PSD) between fast neutron and gamma interactions when coupled to an appropriate scintillator. At the same time, the large number of channels in a typical array calls for the development of low-cost and low-power electronics. A custom integrated circuit (ASIC) is an ideal solution for this purpose. To assess the requirements for such an ASIC, studies were performed using two scintillators, Stilbene and EJ-276, coupled to a 6 x 6 mm SiPM from Onsemi. We demonstrate that both scintillators are viable for performing PSD for interaction energies from 100 keV to several MeV while optimizing the integration periods used in the PSD metric. These measurements inform the design parameters of the ASIC under development.

Si-PMTs↗

Doping liquid argon with xenon in ProtoDUNE Single-Phase: effects on scintillation light

Doping of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first doping test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 720 t of total liquid argon mass with 410 t of fiducial mass. A 5.4 ppm nitrogen contamination was present during the xenon doping campaign. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon doping can substantially recover light losses due to contamination of the liquid argon by nitrogen.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Silicon Photomultiplier Photon Detection Efficiency at Liquid Nitrogen Temperature

The detection of individual photons at cryogenic temperatures is of interest to many experiments searching for physics beyond the Standard Model. Silicon photomultipliers (SiPMs) are often deployed in liquid argon or liquid xenon to detect scintillation light either directly or after it has been wavelength-shifted. Maximizing the photon detection efficiency (PDE) of the SiPMs used in these experiments optimizes the sensitivity to new physics; however, the PDEs of commercial SiPMs, although well known at room temperature, are not well characterized at the cryogenic temperatures at which many experiments operate them. Here we present results from an experimental setup that measures the photon detection efficiencies of silicon photomultipliers at liquid nitrogen temperature, 77 K. Results from a KETEK PM3325-WB-D0 and a Hamamatsu S13360-3050CS silicon photomultiplier — of R&D interest to the LEGEND experiment — exhibit a decrease in photon detection efficiency greater than 20% at liquid nitrogen temperature relative to room temperature for 562 nm light.

Cryogenic detectors↗

Neutron detection efficiency measurements of organic glass scintillator arrays

We characterize the neutron detection efficiency of pixelated organic glass scintillator (OGS) arrays manufactured in two ways: an additive method in which the OGS is cast in place in a pixelated mold, and a subtractive method in which the scintillator is first cast as a large block before being cut in bars and bonded together to form the array. The cast-in-place array utilizes a mixture of “bis(9,9-dimethyl-9H-fluoren-2-yl)diphenylsilane” (P2), “tri([1,1'-biphenyl]-4-yl)(phenyl)silane” (PB3), and “4-bis(2-methylstyryl)benzene” (MSB), and 50% by weight of polystyrene is added to the mixture for subtractive manufactured array. We compare the performance of the OGS arrays to that of an EJ-299-33M plastic scintillator array that was manufactured using a subtractive process similar to that of the second OGS array.

Neutron detectors (cold, thermal, fast neutrons)↗

DUNE Photon Detection System

The Deep Underground Neutrino Experiment (DUNE) aims to provide a broad physics program primarily addressed to probing CP violation in the neutrino sector and identifying the neutrino mass hierarchy. The search for proton decay, the observation of supernova neutrino bursts, and the investigation of solar neutrinos represent other additional goals of DUNE experiment, which can be enhanced by the use and the high performances of the Photon Detection System (PDS). Using the technology based on liquid argon Time Projection Chamber (LArTPC), the experiment plans to observe neutrino interactions inside detectors located 1300 km away from the Long Baseline Neutrino Facility (LBNF) at Fermi National Accelerator Laboratory (FNAL), where the neutrinos are produced. The experiment consists of two main parts, respectively the far and near detectors. The far site will comprise four detector modules. The first module is constituted by a vertical drift single-phase LArTPC, while the second module provides a horizontal drift single-phase LArTPC. The configurations of the other modules are still under definition. Neutrino detection in LArTPCs is achieved by identifying the charge and light generated from its interactions with liquid argon. The wire planes of the instrumented anode and the PDS detect these signals, respectively. The PDS in the first two modules, detailed in the present document, uses a modified version of the so-called ARAPUCA technology, named X-ARAPUCA. This system consisting of a highly reflecting box with an entrance window made by dichroic filters and wavelength shifters, creates a trap to detect the VUV (128 nm) scintillation photons. The X-ARAPUCA of the first module is called Supercell, and it has dimensions of 488×100 mm 2 , while Megacell is the second module version, with an active area of 60×60 cm 2 . This latter configuration also represents a significant technological advancement. Since half of the modules are placed on the cathode at high voltage, they are powered and read out using innovative power-over-fiber (PoF) and signal-over-fiber (SoF) technologies. Meanwhile, the other half are installed in a membrane behind the field cage, with a total transparency of around 70%.

Neutrino detectors↗

Investigating resource-efficient neutron/gamma classification ML models targeting eFPGAs

There has been considerable interest and resulting progress in implementing machine learning (ML) models in hardware over the last several years from the particle and nuclear physics communities. A big driver has been the release of the Python package, hls4ml, which has enabled porting models specified and trained using Python ML libraries to register transfer level (RTL) code. So far, the primary end targets have been commercial field-programmable gate arrays (FPGAs) or synthesized custom blocks on application specific integrated circuits (ASICs). However, recent developments in open-source embedded FPGA (eFPGA) frameworks now provide an alternate, more flexible pathway for implementing ML models in hardware. These customized eFPGA fabrics can be integrated as part of an overall chip design. In general, the decision between a fully custom, eFPGA, or commercial FPGA ML implementation will depend on the details of the end-use application. In this work, we explored the parameter space for eFPGA implementations of fully-connected neural network (fcNN) and boosted decision tree (BDT) models using the task of neutron/gamma classification with a specific focus on resource efficiency. We used data collected using an AmBe sealed source incident on Stilbene, which was optically coupled to an OnSemi J-series silicon photomultiplier (SiPM) to generate training and test data for this study. We investigated relevant input features and the effects of bit-resolution and sampling rate as well as trade-offs in hyperparameters for both ML architectures while tracking total resource usage. The performance metric used to track model performance was the calculated neutron efficiency at a gamma leakage of 10 -3 . The results of the study will be used to aid the specification of an eFPGA fabric, which will be integrated as part of a test chip.

47 OTHER INSTRUMENTATION↗

Scalable photonic integrated circuits for high-fidelity light control

Advances in laser technology have driven discoveries in atomic, molecular, and optical (AMO) physics and emerging applications, from quantum computers with cold atoms or ions, to quantum networks with solid-state color centers. This progress is motivating the development of a new generation of optical control systems that can manipulate the light field with high fidelity at wavelengths relevant for AMO applications. These systems are characterized by criteria: (C1) operation at a design wavelength of choice in the visible (VIS) or near-infrared (IR) spectrum, (C2) a scalable platform that can support large channel counts, (C3) high-intensity modulation extinction and (C4) repeatability compatible with low gate errors, and (C5) fast switching times. Here, we provide a pathway to address these challenges by introducing an atom control architecture based on VIS-IR photonic integrated circuit (PIC) technology. Based on a complementary metal–oxide–semiconductor fabrication process, this atom-control PIC (APIC) technology can meet system requirements (C1)–(C5). As a proof of concept, we demonstrate a 16-channel silicon-nitride-based APIC with (5.8±0.4)ns response times and >30dB extinction ratio at a wavelength of 780 nm.

Menssen, Adrian J.↗