Search NASA⌕ Search

SEARCH · Search NASA

Results for “vision screening”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

In Search of Optimum Fresh-Cut Raw Material: Using Computer Vision Systems as a Sensory Screening Tool for Browning-Resistant Romaine Lettuce Accessions

The popularity of ready-to-eat (RTE) salads has prompted novel technology to prolong the shelf life of their ingredients. Fresh-cut romaine lettuce is widely used in RTE salads; however, its tendency to quickly discolor continues to be a challenge for the industry. Selecting the ideal lettuce accessions for use in RTE salads is essential to ensure maximum shelf life, and it is critical to have a practical way to assess and compare the quality of multiple lettuce accessions that are being considered for use in fresh-cut applications. Thus, in this work we aimed to determine whether a computer vision system (CVS) composed of image acquisition, processing, and analysis could be effective to detect visual quality differences among 16 accessions of fresh-cut romaine lettuce during postharvest storage. The CVS involved a post-capturing color correction, effective image segmentation, and calculation of a browning index, which was tested as a predictor of quality and shelf life of fresh-cut romaine lettuce. The results demonstrated that machine vision software can be implemented to replace or supplement the scoring of a trained panel and instrumental quality measurements. Overall visual quality, a key sensory parameter that determines food preferences and consumer behavior, was highly correlated with the browning index, with a Pearson correlation coefficient of −0.85. Other important sensory decision parameters were also strongly or moderately correlated with the browning index, with Pearson correlation coefficients of −0.84 for freshness, 0.79 for off odor, and 0.57 for browning. The ranking of the accessions according to quality acceptability from the sensory evaluation produced a similar pattern to those obtained with the CVS. This study revealed that multiple lettuce accessions can be effectively benchmarked for their performance as fresh-cut sources via a CVS-based method. Future opportunities and challenges in using machine vision image processing to predict consumer preferences for RTE salad greens is also discussed.

Agriculture↗

High-throughput methods leveraging robotics and computer vision for the development of therapeutic phage cocktails

We present the high-throughput automated screening techniques that are being used to develop bacteriophage-based therapeutic products currently under investigation in human clinical trials to combat urinary tract infections. By integrating modern liquid handling robotics, standardized phenotypic assays, and computer vision-based enumeration, we established a platform capable of reproducibly screening large collections of phages against clinically derived bacterial strain panels. This approach enabled systematic assessment of phage-bacteria interactions at scale, facilitating the identification and optimization of phage cocktails with broad in vitro activity. Although bacteriophage therapy has long been investigated as a strategy for treating bacterial infections, few frameworks exist for developing phage combinations in a reproducible and scalable manner. The methods outlined here address this gap and aim to support the broader development of therapeutic assets available to combat antibiotic resistance.

Penke, Taylor J. R. [Locus Biosciences, Morrisvill↗

Radsource Mr: Mixed Reality Planning Tool For Radioactive Recovery

The RadSource MR system leverages Meta Quest 3's advanced mixed reality capabilities to create a comprehensive spatial planning platform for end-of-life sealed radioactive source recovery operations. The application utilizes the Quest 3's high-resolution passthrough cameras and spatial mapping algorithms to generate accurate 3D environmental models. Core technical components include: (1) Real-time spatial measurement algorithms calculating distances, angles, slopes, and surface areas with sub-centimeter accuracy; (2) Virtual object placement system allowing users to position digital representations of recovery equipment (trailers, containment vessels, protective barriers) within the real environment; (3) Voice recording and annotation system for hands-free documentation in protective equipment; (4) 3D mesh capture and storage capabilities for post-operation analysis and regulatory documentation. (5) Procedure documentation is available for viewing in Mixed Reality, providing an innovative and convenient way to access the information during pre-visit and inspection activities. (6) Support for screen capture for the view for real world and virtual objects together to use it later for planning. The system integrates computer vision techniques for environmental understanding, spatial mathematics for precise measurements, and human-computer interaction principles optimized for hazardous environment operations. Data persistence allows teams to save and share planning sessions across multiple stakeholders while maintaining operational security requirements.

Khadka, Rajiv [Idaho National Laboratory (INL), Id↗

HDBind: encoding of molecular structure with hyperdimensional binary representations

Traditional methods for identifying “hit” molecules from a large collection of potential drug-like candidates rely on biophysical theory to compute approximations to the Gibbs free energy of the binding interaction between the drug and its protein target. These approaches have a significant limitation in that they require exceptional computing capabilities for even relatively small collections of molecules. Increasingly large and complex state-of-the-art deep learning approaches have gained popularity with the promise to improve the productivity of drug design, notorious for its numerous failures. However, as deep learning models increase in their size and complexity, their acceleration at the hardware level becomes more challenging. Hyperdimensional Computing (HDC) has recently gained attention in the computer hardware community due to its algorithmic simplicity relative to deep learning approaches. The HDC learning paradigm, which represents data with high-dimension binary vectors, allows the use of low-precision binary vector arithmetic to create models of the data that can be learned without the need for the gradient-based optimization required in many conventional machine learning and deep learning methods. This algorithmic simplicity allows for acceleration in hardware that has been previously demonstrated in a range of application areas (computer vision, bioinformatics, mass spectrometery, remote sensing, edge devices, etc.). To the best of our knowledge, our work is the first to consider HDC for the task of fast and efficient screening of modern drug-like compound libraries. We also propose the first HDC graph-based encoding methods for molecular data, demonstrating consistent and substantial improvement over previous work. We compare our approaches to alternative approaches on the well-studied MoleculeNet dataset and the recently proposed LIT-PCBA dataset derived from high quality PubChem assays. We demonstrate our methods on multiple target hardware platforms, including Graphics Processing Units (GPUs) and Field Programmable Gate Arrays (FPGAs), showing at least an order of magnitude improvement in energy efficiency versus even our smallest neural network baseline model with a single hidden layer. Our work thus motivates further investigation into molecular representation learning to develop ultra-efficient pre-screening tools. We make our code publicly available at https://github.com/LLNL/hdbind.

59 BASIC BIOLOGICAL SCIENCES↗

Data imbalance in drug response prediction: multi-objective optimization approach in deep learning setting

Abstract Drug response prediction (DRP) methods tackle the complex task of associating the effectiveness of small molecules with the specific genetic makeup of the patient. Anti-cancer DRP is a particularly challenging task requiring costly experiments as underlying pathogenic mechanisms are broad and associated with multiple genomic pathways. The scientific community has exerted significant efforts to generate public drug screening datasets, giving a path to various machine learning models that attempt to reason over complex data space of small compounds and biological characteristics of tumors. However, the data depth is still lacking compared to application domains like computer vision or natural language processing domains, limiting current learning capabilities. To combat this issue and improves the generalizability of the DRP models, we are exploring strategies that explicitly address the imbalance in the DRP datasets. We reframe the problem as a multi-objective optimization across multiple drugs to maximize deep learning model performance. We implement this approach by constructing Multi-Objective Optimization Regularized by Loss Entropy loss function and plugging it into a Deep Learning model. We demonstrate the utility of proposed drug discovery methods and make suggestions for further potential application of the work to achieve desirable outcomes in the healthcare field.

Biochemistry & Molecular Biology↗

Accelerating Computational Materials Discovery with Machine Learning and Cloud High-Performance Computing: from Large-Scale Screening to Experimental Validation

High-throughput computational materials discovery has promised significant acceleration of the design and discovery of new materials for many years. Despite a surge in interest and activity, the constraints imposed by large-scale computational resources present a significant bottleneck. Furthermore, examples of large-scale computational discovery carried through experimental validation remain scarce, especially for materials with product applicability. In this paper, we demonstrate how this vision became reality by first combining state-of-the-art artificial intelligence (AI) models and traditional physics-based models on cloud high performance computing (HPC) resources to quickly navigate through more than 32 million candidates and predict around half a million potentially stable materials. Focusing on solid-state electrolytes for battery applications, our discovery pipeline further identified 18 promising candidates with new compositions and rediscovered a decade’s worth of collective knowledge in the field as a byproduct. By employing around one thousand virtual machines in the cloud, this process took less than 80 hours. We then synthesized and experimentally characterized the structures and conductivities of our top candidates, the Na x Li 3-x YCl 6 (0.5 ≤ x ≤ 2.5) series, demonstrating the potential of these compounds to serve as solid electrolytes. Additional candidate materials are currently under experimental investigation that could offer more examples of the computational discovery of new phases of Li- and Na-conducting solid electrolytes. We believe this unprecedented approach of synergistically integrating AI models and cloud HPC not only accelerates materials discovery but also showcases the potency of AI-guided experimentation in unlocking transformative scientific breakthroughs with real-world applications.

36 MATERIALS SCIENCE↗

Illuminating the Material World: Autonomous Microscopy to Understand Order, Disorder, and Everything In Between

Artificial intelligence (AI) holds immense promise for revolutionizing microscopy, yet its widespread adoption has been hindered by challenges ranging from user inexperience to limited model transferability and difficulties in operationalizing machine learning. This presentation showcases our approach to developing practical autonomy for materials discovery, aiming to accelerate the integration of AI into everyday microscopy workflows. As shown in Fig. 1, I will focus on three key areas: understanding order-disorder transitions, quantifying point defects, and achieving truly device-scale microscopy. First, I will demonstrate the power of multi-modal knowledge graphs for integrating diverse microscopy data. By combining imaging, spectroscopy, and diffraction data, these graphs provide a holistic view of material behavior, capturing the intricate relationships between different modalities [1,2]. I will present a case study on how these models illuminate the structural and chemical changes associated with irradiation in oxide thin films, revealing critical insights for designing materials for extreme environments like spaceflight and nuclear energy. Specifically, I will show how multi-modal analysis clarifies the evolution of order-disorder transitions under irradiation, a key factor influencing material performance in these applications. Next, I will address the challenge of quantifying point defects in 2D materials. We demonstrate the application of computer vision and transfer learning to accurately identify and classify various defect types, such as vacancies and substitutional atoms, and to quantify their concentrations. This information is crucial for understanding and tailoring the properties of 2D materials for applications in electronics, optoelectronics, and catalysis. For example, I will show how our models can characterize the topological distribution of point defects in MXene transition metal carbides, providing valuable insights for optimizing their performance in energy storage and separation science. Finally, I will discuss our progress toward autonomous device-scale microscopy [3,4]. We are fundamentally redesigning electron microscopes around the principles of machine reasoning, enabling automation beyond basic tasks like sample navigation and data acquisition to include sophisticated experimental design. This approach paves the way for truly reproducible and massively scaled analysis campaigns. I will emphasize the importance of autonomous microscopy platforms for high-throughput materials discovery and characterization, facilitating the rapid screening of materials for a broad range of applications and accelerating the development of next-generation technologies.

36 MATERIALS SCIENCE↗

Short-Wave Infrared Upconverting Nanoparticles

Optical technologies enable real-time, noninvasive analysis of complex systems but are limited to discrete regions of the optical spectrum. While wavelengths in the short-wave infrared (SWIR) window (typically, 1700-3000 nm) should enable deep subsurface penetration and reduced photodamage, there are few luminescent probes that can be excited in this region. Here, we report the discovery of lanthanide-based upconverting nanoparticles (UCNPs) that efficiently convert 1740 or 1950 nm excitation to wavelengths compatible with conventional silicon detectors. Screening of Ln3+ ion combinations by differential rate equation modeling identifies Ho3+/Tm3+ or Tm3+ dopants with strong visible or NIR-I emission following SWIR excitation. Experimental upconverted photoluminescence excitation (U-PLE) spectra find that 10% Tm3+-doped NaYF4 core/shell UCNPs have the strongest 800 nm emission from SWIR wavelengths, while UCNPs with an added 2% or 10% Ho3+ show the strongest red emission when excited at 1740 or 1950 nm. Mechanistic modeling shows that addition of a low percentage of Ho3+ to Tm3+-doped UCNPs shifts their emission from 800 to 652 nm by acting as a hub of efficient SWIR energy acceptance and redistribution up to visible emission manifolds. Parallel experimental and computational analysis shows rate equation models are able to predict compositions for specific wavelengths of both excitation and emission. These SWIR-responsive probes open a new IR bioimaging window, and are responsive at wavelengths important for vision technologies.

Qi, Xiao↗

Demonstration and Automation of Reflected Target Optical Measurement for Heliostats

Accurate optical surfaces are a primary driver of concentrated solar power plant performance. Errors in pointing and tracking mirrors, the canting of individual mirror facets, and the surface slope of the mirror itself can be caused by errors during assembly, transportation, wind loading, gravity, and many other sources. The tools that exist to measure these error sources today largely rely on fringe deflectometry (SOFAST, QDec, others), or photogrammetry with targets attached to the mirror surface. Since 2022, NREL has been developing a measurement method called the Reflected Target Non-intrusive Assessment (ReTNA) system. This system differs from most established methods in that we perform deflectometry with a pattern of coded targets, identified in space with photogrammetry. Reflected target systems have several advantages over traditional fringe deflectometry systems. Firstly, they can be operated in bright or ambient lighting, a challenge for fringe systems that use a projector and screen. Reflected target systems also can use a much lighter and less expensive target than projector-based systems. Lastly, 2D slope measurement can be solved from a single image, which leads to several advantages for accommodating faster measurements and smaller sized targets. These advantages make ReTNA particularly well-suited for applications where there are space or lighting constraints, like performing heliostat quality assurance on an assembly line. It's also useful when a lightweight, flexible system is needed, like for heliostat developers to quickly measure a new heliostat design at different orientations, to observe gravitational effects on the mirror surface shape. In the last year, significant improvements were made to this tool to make it more useful for these applications. These improvements were focused around validation of the ReTNA measurement system, and automation of the setup and measurement process. First, we present an improved ReTNA layout, for use on the heliostat assembly line. Next, we detail the various changes to the ReTNA software and computer vision methods to automate data collection in this new setup, and lessons learned from this process. The goal with this new setup is to perform a full heliostat surface characterization without removing the mirror from the assembly line. Lastly, we share results from several ReTNA validation studies undertaken over the last year. These include repeated ReTNA measurement on demonstration mirror facets, comparisons with other optical measurement tools, and some studies aimed at quantifying the uncertainty of ReTNA measurement under various constraints (mirror-target spacing, camera resolution, etc.). These results are compared with 2024 HelioCon performance targets, and our planned next steps for the ReTNA measurement system are presented.

CSP↗

Dataset for Leveraging CryoEM and AI-Driven Morphological Feature Analysis for Insights on Bacterial Structures

This repository hosts an AI-assisted image segmentation and analysis pipeline for Pantoea sp. YR343 cryo-electron microscopy (cryoEM) datasets. The workflow automates membrane thickness measurements, flagella detection, and field-of-view (FOV) screening from low-dose, high-resolution cryoEM micrographs eliminating the need for slow manual annotation. By integrating deep-learning based segmentation (YOLOv11) with quantitative post-processing, this toolkit provides a scalable and reproducible way to study bacterial morphology under hydrated, near-native conditions. The GitHub repository for AI-based tools for cryoEM bacteria ultrastructures can be found here: https://github.com/Sireesiru/Cryo-EM-Ultrastructures/tree/main

60 APPLIED LIFE SCIENCES↗

Dataset for Top Model Decision Tree: Selecting Segmentation Models for Reliable Quantitative Analysis in Low- and Ultralow-Dose CryoEM

Motivation Multiple deep learning model architectures can be used to segment bacterial membranes in cryoEM images. However, an AI-based tool advancement is often presented with only a single segmentation model for broad use, and this single model may show inconsistent results across datasets from different users. Here, we present the Top Model Decision Tree, a model screening framework to screen for the best model to generate bacterial inner and outer membrane masks based on user priorities. We use pre-trained segmentation models from YOLOv11, YOLO26, U-Net, Detectron2 and SAM3 fine-tuned on bacterial inner and outer membranes imaged with cryoEM. Run the Framework This notebook must be opened in Google Colab. Mount Google Drive and run with a GPU-based runtime. Open the notebook and follow steps to git clone in folders and files within this repository. There will be a repeating top_model_decision_tree.ipynb (notebook clone) that will not be used. Save your .png binary mask files and .csv table outputs within your Google Drive or download before closing the notebook. The models and all analysis/training scripts are available at [GitHub: https://github.com/Lynnicia/CryoEM_membranes_top_model_decision_tree and https://github.com/Sireesiru/Semantic-Segmentation-of-bacterial-cell-envelope-using-U-Nets.

59 BASIC BIOLOGICAL SCIENCES↗

The Art of Automation: Translating Electron Microscopy Workflows Into Automated Processes

Acquiring data using a scanning transmission electron microscope (STEM) is a complex, multi-step process. The intricacy of the process depends on the type of sample, composition of the material, desired results of the experiment, resolution requirement and other experimental factors. Each experiment presents unique complications, such as sample drift and contamination, that the microscopist must consider when acquiring data. All these challenges are handled fluidly and expertly by experienced microscopists, but to reach new levels of innovation in material development, including greater reproducibility, throughput, and precision, the automation of these workflows is essential. The initial phase of this work involved translating intuition-based workflows into discrete, programmable steps. Some common key stages in STEM workflows are the initial tuning, scanning the sample for areas of interest, and then acquiring the data. Each stage can be broken further into specific parameter adjustments, such as aberration correction and dwell time optimization, depending on the experiment. When deconstructing various experiments each step was assessed for automation feasibility based on the amount of real time operator decisions. There are steps that lend themselves to automation more readily than others, such as course focusing and sample screening, but there is potential for full automation of all stages with time. As an initial step, an automated montage routine was developed, allowing for the efficient acquisition of large portions of the sample without requiring continuous intervention from the operator. The automation of this small process of the procedure demonstrates the value of this capability. A major challenge in automation arises from discrepancies between commanded, reported and actual stage movements. Using systematic tests, stage movement was quantified. This error can be corrected algorithmically for more accurate workflows in the future. Expanding automation capabilities would result in larger, more efficient data acquisition which allows for more robust statistical analysis. Additionally, this work lays the groundwork for a closed loop system where machine learning algorithms would intake automatically acquired data and make real time decisions. By progressively automating this instrument, this work establishes the foundation for fully automated experimentation in transmission electron microscopy.

97 MATHEMATICS AND COMPUTING↗