Search NASA⌕ Search

SEARCH · Search NASA

Results for “visual indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The effect of a visual indicator on rate of visual search Evidence for processing control

Search rates were estimated from response latencies in a visual search task of the type used by Atkinson et al. (1969), in which a subject searches a small set of letters to determine the presence or absence of a predesignated target. Half of the visual displays contained a marker above one of the letters. The marked letter was the only one that had to be checked to determine whether or not the display contained the target. The presence of a marker in a display significantly increased the estimated rate of search, but the data clearly indicated that subjects did not restrict processing to the marked item. Letters in the vicinity of the marker were also processed. These results were interpreted as showing that subjects are able to exercise some degree of control over the search process in this type of task.

Holmgren, J. E.↗

Optimal flash rate and duty cycle for flashing visual indicators.

This experiment examined the ability of observers to determine, as quickly as possible, whether a visual indicator was steadily on or flashing. Six flash rates (periods) were combined factorially with three duty cycles (on-off ratios) to define 18 ?types' of intermittent signals. Experimental sessions were divided into six runs of 100 trials, each run utilizing one of the six flash rates. On any given trial in a run, the probability of a steady signal occurring was 0.5 and the probability of a flashing signal occurring was 0.5. A different duty cycle was employed daily for each experimental session. In all, 400 trials were devoted to each of the flash rates at each duty cycle. Accuracy and latency of response were the dependent variables of interest. The results show that the observers view the light for an interval of time appropriate to the expected flash rate and duty cycle; whether they judge the light to be steady or intermittent depends upon whether the light is extinguished during the predetermined waiting period. Adoption of this temporal criterion delays responding in comparison to those tasks involving responses to light onset. The decision or response criteria held by the observers are also sensitive to the parameters of the flashing light: observers become increasingly willing to call a flashing light ?steady' as flash duration increases.

Markowitz, J.↗

Fused diode provides visual indication of fuse condition

Fused diode combines a semiconductor diode and a circuit protective fuse within a common transparent cartridge. It provides visual indication of fuse condition which precludes the necessity of making resistance checks with an ohmmeter.

Jenkins, K. H.↗

Retractable Visual Indicator Assembly

A retractable indicator assembly may be mounted on a container which transmits air through the container and removes deleterious gases with an activated charcoal medium in the container. The assembly includes: an elongate indicator housing has a chamber therein; a male adaptor with an external threads is used for sealing engagement with the container; a plug located at the upper end of the housing; a housing that includes a transparent wall portion for viewing at least a portion of the chamber; a litmus indicator, moveable by a retractable rod from a retracted position within the container to an extended position within the chamber of the housing; and an outer housing that is secured to the upper end of the rod, and protects the indicator housing while the litmus indicator is in its normally retracted position. The assembly may be manually manipulated between its extended position wherein the litmus indicator may be viewed through the transparent wall of the indicator housing, and a retracted position wherein the outer housing encloses the indicator housing and engages the exterior of the container.

Hackler, George R.↗

Surface flow visualization using indicators

Surface flow visualization using indicators in the cryogenic wind tunnel which requires a fresh look at materials and procedures to accommodate the new test conditions is described. Potential liquid and gaseous indicators are identified. The particular materials illustrate the various requirements an indicator must fulfill. The indicator must respond properly to the flow phenomenon of interest and must be observable. Boundary layer transition is the most important phenomenon for which flow visualization indicators may be employed. The visibility of a particular indicator depends on utilizing various optical or chemical reactions. Gaseous indicators are more difficult to utilize, but because of their diversity may present unusual and useful opportunities. Factors to be considered in selecting an indicator include handling safety, toxicity, potential for contamination of the tunnel, and cost.

Crowder, J. P.↗

A new quantitative indicator of visual fatigue

Ocular-motor correlates of visual fatigue have remained elusive. Performance of ocular-motor tracking with a wide-band white noise input and the response of the dual-mode, smooth pursuit-saccadic eye movement system as output was used to test visual fatigue. A new visual fatigue indicator, VFI, was defined as the nonlinear remnant after subtracting an identified impulse response contribution to the output. Subjects were required to perform very fatiguing CRT screen reading tasks, and the VFI correlated well with the subjective reports of visual fatigue.

Goussard, Yves↗

TPSAS-NF1676L-18030-DND

This study investigated the relative acceptance of different avionics implementations that present Flightdeck Interval Management (FIM) speeds and speed deviations to commercial pilots, and for indications of conditions that require action. Each crew evaluated four Avionics conditions: (1) Integrated in which the FIM target speed was presented in the upper left corner of the primary flight display (PFD) and speed profile deviation information was implicitly indicated as the deviation between current speed and an instantaneous speed profile bug on the PFD speed tape. In this Avionics condition, clearance information would have been entered, and could be referenced, on the FIM page in the MCDU. This page also gave a digital readout of speed profile deviation. Significant deviations from the speed profile triggered a message on the EICAS system. (2) EFB-Aft in which an aft-mounted EFB was used as the device housing the FIM algorithm and presented all the relevant information for the operation, including speed targets, speed deviation information, and all elements of the IM clearance. Significant deviations from the speed profile triggered messages on the same EFB display. (3) EFB-Fore in which the same information was presented as in the EFB-Aft condition, but the display was mounted in a more forward location, just under the outboard window. (4) EFB-Aft-AGD in which the EFB-Aft condition was augmented with the ADS-B Guidance Display (AGD). The AGD repeats the same FIM target speed and speed deviation information provided on the EFB. This study compares the efficacy of these Avionics Conditions as well as three methods of annunciating FIM events (a new speed, a reminder that a new speed occurred, and a deviation from the FIM speed profile), using only visual indications, visual indications and an aural for all events, or visual indications for all events plus an aural for speed deviations only. Results show clear preference for the Integrated condition and the use of aural indications. Other metrics of performance using these conditions and methods are mixed.

Kara Latorella↗

Carbon dioxide concentration indicator

Device will provide visual indication of concentration of carbon dioxide. It consists of small amounts of absorbent material contained in semipermeable membrane and device to detect color changes. Material will absorb quantity of carbon dioxide proportional to carbon dioxide concentration in atmosphere. Amount of absorption is indicated by color change.

King, P. H.↗

Remote manual operator for space station intermodule ventilation valve

The Remote Manual Operator (RMO) is a mechanism used for manual operation of the Space Station Intermodule Ventilation (IMV) valve and for visual indication of valve position. The IMV is a butterfly-type valve, located in the ventilation or air circulation ducts of the Space Station, and is used to interconnect or isolate the various compartments. The IMV valve is normally operated by an electric motor-driven actuator under computer or astronaut control, but it can also be operated manually with the RMO. The IMV valve RMO consists of a handle with a deployment linkage, a gear-driven flexible shaft, and a linkage to disengage the electric motor actuator during manual operation. It also provides visual indication of valve position. The IMV valve RMO is currently being prepared for qualification testing.

Guyaux, James R.↗

Aircraft maneuver envelope warning system

A maneuver envelope warning system for an aircraft having operating limits, operating condition sensors and an indicator driver. The indicator driver has a plurality of visual indicators. The indicator driver determines a relationship between sensed operating conditions and the operating limits; such as, a ratio therebetween. The indicator driver illuminates a number of the indicators in proportion to the determined relationship. The position of the indicators illuminated represents to a pilot in an easily ascertainable manner whether the operational conditions are approaching operational limits of the aircraft, and the degree to which operational conditions lie within or exceed operational limits.

Bivens, Courtland C.↗

Final Report on the Detection of Green Monopropellants

In 2014, National Aeronautics and Space Administration (NASA) Kennedy Space Center (KSC) funded a project titled "Familiarization and Detection of Green Monopropellants" utilizing Independent Research and Technology Development (IR&TD) and Center Innovation Fund (CIF) funding. The purpose of the project was to evaluate methods of detection for ammonium dinitramide (ADN) and hydroxylammonium nitrate (HAN). An Engineering Services Contract (ESC) task order was created with the scope of evaluation of several methods of detecting ADN- and HAN-based propellants, as well as development of methods for detection. Detection methods include developed methods such as colorimetric indicating absorbent socks, and commercial-off-the- shelf (COTS) units for ammonia detection. An additional goal of the task order was for ESC to become familiar with ADN's and HAN's material properties and material compatibility. Two approaches were initially investigated as possible methods for the detection of HAN (or AFM315E) and ADN (or LMP-103S). These approaches were colorimetric analysis and instrumentation-based COTS vapor sensors utilization. Initial testing showed that the relatively non-existent vapor pressure of the AF-M315E (of which HAN is a major component) propellant would make the use of COTS sensors difficult for real-time area monitoring of HAN; a small response was detected through the use of active COTS sensors, including the RAE Systems MultiRAE Lite and Drager X-act (registered) 5000, but the levels detected were below the threshold limit value for the toxic gas ammonia. Therefore, a detection system ased upon a colorimetric indicator impregnated into an absorbent material was developed. Preliminary analysis (ESC-245-FDG-001) identified a particularly outstanding candidate as a colorimetric indicator for the detection of the presence of AF-M315E in the form of a Methyl Red (Basic) indicator. Materials impregnated with this indicator exhibit significant color change and the materials are not susceptible to interference from exposure to water or carbon dioxide. The completed detection system for HAN/AF-M315E consists of absorbent socks packed with Fisher Universal Spill Absorbent capable of absorbing and containing any propellant spills that they come into contact with along with indicating wipes. The absorbent socks are also chemically treated with a Methyl Red (Basic) indicator solution to provide the end user with a visual indication that a leak has occurred and proper protective precautions must be undertaken. An added benefit of this detection system is that the absorbent socks should neutralize/absorb any commodity that it comes into contact with (until saturation is reached). Additional adsorbent socks can be deployed until a color change is not seen, indicating that the HAN/AF-M315E contamination has been contained. The indicating wipes provide the user the opportunity to wipe surfaces to determine if there is any HAN/AF-M315E or HAN/AFM315E residue present. The wipes should allow the detection of fuel levels that may be too small to detect with the absorbent socks. The development of a detection system for the ADN/LMP-103S focused on the use of various COTS sensors used as real-time area monitoring devices and personal dosimeters. These COTS based sensor systems were of several different types, including both actively pumped and diffusion-based passive systems, as well as a "rope"-type chemical sensing cable. The results highlighted some of the major differences between the two monopropellants undergoing evaluation. Unlike HAN, ADN (which is the major constituent of LMP-103S) exhibits a much more volatile nature in comparison to AF-M315E. In fact, testing showed that a large percentage of the fuel was lost during the sampling measurement (greater than 10 percent by mass); although this testing cannot tell if the volatile component is the ADN itself or another component of the monopropellant solution. Not surprisingly, all four of the procured vapor-based COTS sensors showed positive results when exposed to solutions of the LMP-103S (ESC-245-FDG-002). The completed detection system for ADN/LMP-103S consists of a combination of two of the tested COTS sensor systems, the RAE Systems MultiRAE Lite and the BW Technologies GasAlert Extreme. These systems are meant to be used in conjunction with one another, which allows for the end-user to have both real-time area monitoring (MultiRAE Lite) as well as a personal dosimeter device (GasAlert Extreme) which can be worn as additional personal protective equipment. An stainless steel extension wand was fabricated and included in the detection system for the MultiRAE Lite to allow for more remote sensing, and connects via the active pumping inlet of the sensor. As stated, the final results of this testing resulted in the production of two "kits" which can be used for the detection of HAN/AF-M315E and ADN/LMP-103s (ESC-245-FDG-003).

Detection↗

Low cost SCR lamp driver indicates contents of digital computer registers

Silicon Controlled Rectifier /SCR/ lamp driver is adapted for use in integrated circuit digital computers where it indicates the contents of the various registers. The threshold voltage at which visual indication begins is very sharply defined and can be adjusted to suit particular system requirements.

Cliff, R. A.↗

3D GeoWall Analysis System for Shuttle External Tank Foreign Object Debris Events

An analytical, advanced imaging method has been developed for the initial monitoring and identification of foam debris and similar anomalies that occur post-launch in reference to the space shuttle s external tank (ET). Remote sensing technologies have been used to perform image enhancement and analysis on high-resolution, true-color images collected with the DCS 760 Kodak digital camera located in the right umbilical well of the space shuttle. Improvements to the camera, using filters, have added sharpness/definition to the image sets; however, image review/analysis of the ET has been limited by the fact that the images acquired by umbilical cameras during launch are two-dimensional, and are usually nonreferenceable between frames due to rotation translation of the ET as it falls away from the space shuttle. Use of stereo pairs of these images can enable strong visual indicators that can immediately portray depth perception of damaged areas or movement of fragments between frames is not perceivable in two-dimensional images. A stereoscopic image visualization system has been developed to allow 3D depth perception of stereo-aligned image pairs taken from in-flight umbilical and handheld digital shuttle cameras. This new system has been developed to augment and optimize existing 2D monitoring capabilities. Using this system, candidate sequential image pairs are identified for transformation into stereo viewing pairs. Image orientation is corrected using control points (similar points) between frames to place the two images in proper X-Y viewing perspective. The images are then imported into the WallView stereo viewing software package. The collected control points are used to generate a transformation equation that is used to re-project one image and effectively co-register it to the other image. The co-registered, oriented image pairs are imported into a WallView image set and are used as a 3D stereo analysis slide show. Multiple sequential image pairs can be used to allow forensic review of temporal phenomena between pairs. The observer, while wearing linear polarized glasses, is able to review image pairs in passive 3D stereo.

Brown, Richard↗

Airflow sensing system

Disclosed is an airflow sensing system for determining the type of airflow flowing over a flight surface. A hot film sensor is driven by a constant voltage feedback circuit that maintains the voltage across the sensor at a predetermined level. A signal processing circuit receives an output signal of the feedback circuit and determines whether the output signal is indicative of laminar, transitional or turbulent airflow. Transitional airflow is distinguished from turbulent airflow by a signal having significant energy in a low-frequency passband from 50-80 Hz. The signal processing circuit drives a three-color LED display to provide a visual indication of the type of airflow being sensed.

Gelbach, Herman R.↗