Search NASASearch

SEARCH · Search NASA

Results for “vital signs monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

3D-Printed mmWave Quasi-Holographic Antenna for 2-D Beamforming

This paper presents the design and manufacturing of a novel 2D-scanning antenna that integrates a 3D-printed Rotman lens with a quasi-holographic leaky-wave antenna (HLWA). The proposed design achieved beam-scanning capabilities by leveraging the beamforming of the Rotman lens and the high-gain directive properties of the quasi-HLWA. The Rotman lens (RL) enables beam steering in the elevation plane by switching between input ports. The quasi-HLWA, designed using holographic principles, achieves frequency-controlled beam scanning in the azimuth plane. The entire antenna structure was fabricated using additive manufacturing with an Ink1092 substrate and silver ink for the conductive traces. This approach provides greater control over material placement and design freedom compared to traditional methods. A 25° transmission linear substrate taper was used to ensure good impedance matching between the Rotman lens and the quasi-HLWA, allowing greater gain while maintaining a good scanning range. The experimental results validate the 2D scanning capability of the proposed antenna. The antenna system provides coverage from −54° to 54° in the elevation θ plane and −28° to 28° in the azimuth plane ϕ , with a maximum measured gain of 21.3 dBi at 28 GHz with an average radiation efficiency η=60 %. The fabricated prototype was tested, and the performance was in good agreement with the simulated performance.

Rotman lens

Intrinsic even-odd thickness-driven anomalous Hall effect in epitaxial MnBi2⁢Te4 thin films

We demonstrate precise control of magnetism in MnBi2⁢Te4 thin films through careful synthesis by molecular beam epitaxy, achieving minimal defects and accurate layer thickness control. By optimizing Mn-Bi-Te ratios and growth temperatures, we minimize detrimental self-doping effects and accurately target integer-layer films. X-ray diffraction and reflectivity provide quantitative measures of film quality and thickness. When these macroscale probes of structure and thickness are integrated with magnetotransport measurements, a striking even-odd layer dependence of the anomalous Hall effect is revealed. Odd-layer films exhibit a large hysteresis up to the Néel temperature (∼25K), consistent with noncompensated antiferromagnetism, while even-layer films show minimal response, as expected for an antiferromagnet. The sign of the anomalous Hall effect exhibits a sign reversal for intrinsic magnetism versus magnetism associated with defects. This work identifies critical factors for inducing pure, noncompensated ferromagnetism and reveals the characteristics of the intrinsic anomalous Hall effect in MnBi2⁢Te4, which together is a step toward realizing the zero-field quantum anomalous Hall effect in topological materials.

Mallick, Deb [ORNL] (ORCID:000900005806411X)

Thermalization and criticality on an analogue–digital quantum simulator

Abstract Understanding how interacting particles approach thermal equilibrium is a major challenge of quantum simulators 1,2 . Unlocking the full potential of such systems towards this goal requires flexible initial state preparation, precise time evolution and extensive probes for final state characterization. Here we present a quantum simulator comprising 69 superconducting qubits that supports both universal quantum gates and high-fidelity analogue evolution, with performance beyond the reach of classical simulation in cross-entropy benchmarking experiments. This hybrid platform features more versatile measurement capabilities compared with analogue-only simulators, which we leverage here to reveal a coarsening-induced breakdown of Kibble–Zurek scaling predictions 3 in theXYmodel, as well as signatures of the classical Kosterlitz–Thouless phase transition 4 . Moreover, the digital gates enable precise energy control, allowing us to study the effects of the eigenstate thermalization hypothesis 5–7 in targeted parts of the eigenspectrum. We also demonstrate digital preparation of pairwise-entangled dimer states, and image the transport of energy and vorticity during subsequent thermalization in analogue evolution. These results establish the efficacy of superconducting analogue–digital quantum processors for preparing states across many-body spectra and unveiling their thermalization dynamics.

Science & Technology - Other Topics

Commercialization of the NLR Hydrogen Wide Area Monitor (HyWAM): Cooperative Research and Development (Final Report)

Hydrogen wide area monitoring refers to the temporal and quantitative 3-dimenasional spatial profiling of hydrogen plumes following either intentional or unintentional hydrogen releases. A hydrogen wide area monitor (HyWAM) would have applications as a research tool, for example to provide empirical data on the behavior of hydrogen dispersions following a release, which in turn can be used to validate modelling studies. Support of modeling studies and commercial applications are interrelated, since modeling can serve to guide HyWAM deployment for enhanced safety within medium to large scale hydrogen operations, such as those envisioned by H2@Scale.

08 HYDROGEN

Digital Twin Based Condition Monitoring of LCC-LCC Inductive Power Transfer Systems

Inductive power transfer (IPT) systems provide a flexible, hands-free charging opportunity to electric vehicles (EV). The resonant network components and the transmitter and receiver coils are often subjected to high voltages or currents. Component aging in the compensation network and coils of resonant IPT systems is detrimental to the reliability and power transfer efficiency of the IPT system. Monitoring the component health of such multi-element complex systems requires robust optimization algorithms. This paper discusses condition monitoring of a resonant IPT system for an EV charger using a digital twin model. A hybrid estimation algorithm based on genetic algorithms and adaptive particle swarm optimization is developed to estimate the parameters of the digital twin model. Simulation results are used to verify the monitoring capabilities of the developed algorithm under various operating conditions of the IPT system.

Weldehawaryat, Lidya Mussie [graduate research ass

Fingerprinting Superconductors by Disentangling Andreev and Quasiparticle Currents Across Tunable Tunnel Junctions

Tunneling Andreev reflection (TAR) spectroscopy provides a new approach to identify superconducting pairing symmetry at the atomic scale. Using atomistic superconducting transport simulations, we reveal the mechanism by which TAR can distinguish between pairing symmetries, which is complementary to traditional conductance-based techniques. In particular, owing to the additivity of the excess tunneling decay rate, the TAR spectrum is a weighted average of the contributions from quasiparticle currents, Andreev reflection, and higher-order scattering processes, and their relative weights depend on both the superconducting order parameter and the coupling strength. Within the local tunneling model, TAR dominates mid-gap conductance for s-wave superconductors, is suppressed for d-wave, and coexists with quasiparticle tunneling in sign-changing symmetries if the expectation value for the superconducting gap remains finite. Meanwhile, higher-order processes generally enhance the TAR signal when GN exceeds approximately 0.1G0. As a result, TAR provides a rich spectral fingerprint of the underlying pairing symmetry and electronic structure, enabling atomically resolved identification of unconventional superconducting states.

Maksymovych, Petro [Clemson University]

Laser-induced graphene gas sensors for environmental monitoring

Artemesia tridentatais a foundational plant taxon in western North America and an important medicinal plant threatened by climate change. Low-cost fabrication of sensors is critical for developing large-area sensor networks for understanding and monitoring a range of environmental conditions. However, the availability of materials and manufacturing processes is still in the early stages, limiting the capacity to develop cost-effective sensors at a large scale. In this study, we demonstrate the fabrication of low-cost flexible sensors using laser-induced graphene (LIG); a graphitic material synthesized using a 450-nm wavelength bench top laser patterned onto polyimide substrates. We demonstrate the effect of the intensity and focus of the incident beam on the morphology and electrical properties of the synthesized material. Raman analyses of the synthesized LIG show a defect-rich graphene with a crystallite size in the tens of nanometers. This shows that the high level of disorder within the LIG structure, along with the porous nature of the material provide a good surface for gas adsorption. The initial characterization of the material has shown an analyte response represented by a change in resistance of up to 5% in the presence of volatile organic compounds (VOCs) that are emitted and detected byArtemisiaspecies. Bend testing up to 100 cycles provides evidence that these sensors will remain resilient when deployed across the landscapes to assess VOC signaling in plant communities. The versatile low-cost laser writing technique highlights the promise of low-cost and scalable fabrication of LIG sensors for gas sensor monitoring.

Chemistry

High-Throughput Uniformity and Defect Monitoring in Low-Temperature Electrolysis Porous Transport Layers Using X-Ray Radiography

Effective quality control (QC) for manufacturing proton exchange membrane water electrolysis (PEMWE) components is critical to enabling widespread adoption of the technology for hydrogen generation. This study investigates X-ray radiography as a novel, high-throughput, potentially in-line QC technique for detecting defects and assessing material property distributions in titanium-based porous transport layers (PTLs) which constitute a crucial component of low temperature PEMWE stacks. We obtain radiographs of a set of fifteen PTLs and model their absorbance of the broadband radiation as a second-order polynomial to account for the non-monoenergetic radiation source used in this study. The resulting model serves as a basis for predicting the areal density and porosity distributions of the PTLs. We find radiography successful in detecting multiple instances of defects, including holes/depressions, cracks, and excess material on the surface or in the pores of the material, demonstrating its potential as a robust in-line QC tool for PTL manufacturing.

08 HYDROGEN

Synthesis and application of thermally responsive nanofiber coatings for overtemperature monitoring

This study presents a one-pot synthesis route to organometallic nanofibers based on copper thiolate, exhibiting distinctive chemical and physical characteristics. Electron microscopy analysis of morphology and composition revealed 2-10 μm-long, 50-90 nm-diameter hollow and non-hollow fibers composed of copper, sulfur, oxygen, hydrocarbon, and chlorine. Thermogravimetric analysis showed a pronounced mass loss within 120°C-135°C. To elucidate the thermal responsive pathways, the nanofibers were characterized before and after heating. X-ray photoelectron spectroscopy indicates that an initially mixed Cu(I)/Cu(II) oxidation states transition to predominantly Cu(I) upon heating. A layer of nanofiber was coated on battery pouch foil and evaluated as a candidate thermally sensitive coating. At elevated temperature (100-130°C), nanofiber coating released volatile organic compounds, sulfide and sulfur dioxide as detected using multiple gas sensors. This thermally responsive gas release/sensing approach provides a potential large-area temperature monitoring strategy, which is particularly relevant where direct temperature measurements of individual batteries is impractical. The results established proof of concept for nanofiber-coated battery pouch foil as overtemperature warning platform that can provide alerts when surface temperatures exceed a critical threshold. More broadly, the ability to form interconnected fiber networks positions copper thiolate nanofiber coatings as promising materials for advanced applications.

Ihala Gamaralalage, Chanaka [ORNL] (ORCID:00000002

Cold Spray Cobalt Magnetostrictive Electromagnetic Acoustic Transducers for High Temperature Structure Monitoring

The Department of Energy’s Advanced Sensors and Instrumentation program seeks to develop and qualify advanced sensors for the nuclear industry. Reliable high temperature and high radiation sensors for detection and characterization of structural flaws in pipes, vessels, and structurally critical components is a weakness for both conventional light water reactors with coolant T-hot approaching 350oC, and for advanced reactors with T-hot temperatures in excess of 500 to 800oC. Magnetostrictive Electromagnetic Acoustic Transducers using a cold spray cobalt coating have been proposed as a sensor design that can withstand these kinds of temperatures and radiation levels to serve as online sensors to detect flaws before cracks, pits, or erosion/corrosion flaws progress to through-wall failures. This report tests cold spray cobalt as part of a magnetostrictive EMAT for high temperature service. Cobalt is known to have strong magnetostrictive properties however the effect of cold spray application is not well studied. This program was surprised to discover that cold sprayed cobalt exhibited little or no magnetostrictive behavior until it was thermally annealed. Following annealing to 650oC however, cold spray cobalt did exhibit a magnetostrictive response. Work to date prior to this milestone report publication showed that magnetostrictive EMAT was successfully tested to 400oC with an alnico permanent magnet. The program plans to extend testing with an electromagnet to higher temperatures. This follow-on work will be reported under subsequent publications or as a revision to this report.

Glass, Samuel W.

Monitoring Depolymerization in Mesopores Using Dynamic Properties of Polymeric Melt Accessed via Dielectric Spectroscopy

Traditional design principles for heterogeneous catalysis guide the use of catalytic particles with mesosized (∼2–50 nm) pores to increase the number of surface-active sites by way of an increased surface area. However, the entry of long-chain polymers into such pores may be significantly limited by the size and entanglement of polymers in the melt state, thereby decreasing the number of accessible sites. Assessment of catalyst performance from traditional reactor-based studies averages over intrapore reaction events as well as reactions on the surface of a particle, resulting in an inability to distinguish between differences in site accessibility and activity. Techniques that assess the intrapore performance can inform the design of future heterogeneous catalysts for polymer upcycling. In this work, we demonstrate the use of broadband dielectric spectroscopy to monitor depolymerization of a polymer melt within mesopores via changes in the segmental relaxation time scale of amorphous polymer chains. In particular, we highlight the use of an anodic aluminum oxide (AAO) membrane as a readily available model for catalyst pores with a well-characterized pore morphology. The decrease in the segmental relaxation (α-relaxation) time of the melt with increasing chain scission emerges as a measure of the extent of polymer deconstruction inside mesopores. To demonstrate the utility of this technique, we demonstrate the decomposition of two commercial poly(propylene carbonate) polymers with different decomposition rates within mesopores. As the polymers depolymerize, their segmental relaxation time decreases as the molecular weight decreases (as predicted by the Fox–Flory equation). The BDS-measured change in segmental relaxation time mirrors the expected trend based on change in molecular weight measured by size exclusion chromatography.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Proximal remote sensing: an essential tool for bridging the gap between high‐resolution ecosystem monitoring and global ecology

Summary A new proliferation of optical instruments that can be attached to towers over or within ecosystems, or ‘proximal’ remote sensing, enables a comprehensive characterization of terrestrial ecosystem structure, function, and fluxes of energy, water, and carbon. Proximal remote sensing can bridge the gap between individual plants, site‐level eddy‐covariance fluxes, and airborne and spaceborne remote sensing by providing continuous data at a high‐spatiotemporal resolution. Here, we review recent advances in proximal remote sensing for improving our mechanistic understanding of plant and ecosystem processes, model development, and validation of current and upcoming satellite missions. We provide current best practices for data availability and metadata for proximal remote sensing: spectral reflectance, solar‐induced fluorescence, thermal infrared radiation, microwave backscatter, and LiDAR. Our paper outlines the steps necessary for making these data streams more widespread, accessible, interoperable, and information‐rich, enabling us to address key ecological questions unanswerable from space‐based observations alone and, ultimately, to demonstrate the feasibility of these technologies to address critical questions in local and global ecology.

Plant Sciences

Superconducting Material Growth for Radio-Frequency (RF) Cavities

Superconducting radio-frequency (SRF) cavities, usually manufactured from Niobium (Nb), are vital components of modern particle accelerators because of their ability to achieve high acceleration gradients with little power dissipation. Naturally forming Nb surface oxides significantly alter cavity performance by changing surface resistance. A nondestructive characterization of oxide thickness is helpful for relating surface processing treatments to cavity performance. This work develops a protocol to measure Nb oxide thickness using Angle-Resolved X-ray Photoelectron Spectroscopy (ARXPS) while correcting instrumental errors. Using uniform bulk standard samples (Silver, Aluminum oxide, and Germanium), we determined a baseline correction factor to account for analyzer-related intensity evolution as the measurement angle increases. The correction factor was then applied to Nb 3d ARXPS data. Applying the Strohmeier equation to the corrected data yielded a Nb2O5 thickness of 6.04 nm, closely matching the 5.5 (±.05) nm value obtained from cross-sectional transmission electron microscopy. Our approach will bring a method to incorporate inherent errors in the thickness measurements using ARXPS and can be broadly applied to improve the accuracy of thickness measurements in a wide range of heterostructures.

Lambert, Nathan [Fermilab]

Raman enhancement induced by exciton hybridization in molecules and 2D materials

Abstract Surface-enhanced Raman spectroscopy (SERS) is a powerful technique for trace-level fingerprinting. Recently, layered two-dimensional (2D) materials have gained significant interest as SERS substrates for providing stable, uniform, and reproducible Raman enhancement with the potential for trace-level detection. Yet, the development of effective 2D SERS substrates is still hindered by the lack of fundamental understanding of the coupling mechanism between target molecules and substrates. Here, we report a systematic excitation-dependent Raman spectroscopy investigation on the coupling between 2D materials such as SnS 2 , MoS 2 , WSe 2 , and graphene and small organic molecules like rhodamine 6G (Rh 6G). Strong coupling between SnS 2 and Rh 6G is found due to their degenerate excitons through Raman excitation profiles (REP), leading to the enhancement of Rh 6G vibrational modes that are observable down to 10 −13 M. Our study shows that exciton coupling in the substrate-adsorbate complex plays a vital role in the Raman enhancement effect, opening a new route for designing SERS substrates for high sensitivity.

Materials Science

Carbon Utilization and Storage Partnership of the Western United States

This technical report documents research conducted under DOE Award No. DE-FE0031837 focused on evaluating the feasibility of carbon capture, utilization, and storage (CCUS) systems in the central and western United States. The project integrated geologic characterization, reservoir simulation, infrastructure modeling, and economic analysis to assess CO₂ storage potential near industrial sources and develop strategies for transport and sequestration. The work included subsurface modeling, risk assessment, monitoring and verification (MRV) planning, and evaluation of regulatory pathways such as EPA Underground Injection Control (UIC) Class VI permitting and IRS 45Q tax credit eligibility. Results demonstrate the viability of multiple storage approaches, including saline formations, enhanced coalbed methane recovery, and basalt mineralization, supported by data-driven workflows and regional analyses. The project also produced permitting templates, technology transfer activities, and stakeholder engagement efforts to support deployment readiness. These findings contribute to the development of scalable, economically viable CCUS systems and provide a repeatable framework for future carbon management projects.

20 FOSSIL-FUELED POWER PLANTS