Quantitative volatile organic compound sensing with liquid crystal core fibers
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Real-time detection of volatile organic compounds (VOCs) is being spotlighted for its importance in environmental monitoring and disease detection from the breath. However, the selective detection of VOCs in a small form factor gas sensor remains a challenge. Here, we present the VOC sensing performance of phthalocyanine (Pc)-functionalized graphene chemiresistors supported by the theoretical prediction of Pc's VOC interactions. Pc functionalization, with and without metalation, was studied parametrically with varying deposition parameters to explore impacts on the gas sensing response toward VOCs as a function of substrate coverage. Sensing data were collected to establish fingerprint signatures for a variety of VOCs. In conclusion, improvement in selectivity is shown by successfully differentiating the VOCs from each other when combined into a gas sensor array tested with acetone, ethanol, formaldehyde, and toluene.
The nonlinear chemical processes involved in ozone production (P(O3)) have necessitated using proxy indicators to convey information about the primary dependence of P(O3) on volatile organic compounds (VOCs) or nitrogen oxides (NOx). In particular, the ratio of remotely sensed columns of formaldehyde (HCHO) to nitrogen dioxide (NO2) has been widely used for studying O3 sensitivity. Previous studies found that the errors in retrievals and the incoherent relationship between the column and the near-surface concentrations are a barrier in applying the ratio in a robust way. In addition to these obstacles, we provide calculational-observational evidence, using an ensemble of 0-D photochemical box models constrained by DC-8 aircraft measurements on an ozone event during the Korea-United States Air Quality (KORUS-AQ) campaign over Seoul, to demonstrate the chemical feedback of NO2 on the formation of HCHO is a controlling factor for the transition line between NOx-sensitive and NOx-saturated regimes. A fixed value (~2.7) of the ratio of the chemical loss of NOx (LNOx) to the chemical loss of HO2+RO2 (LROx) perceptibly differentiates the regimes. Following this value, data points with a ratio of HCHO/NO2 less than 1 can be safely classified as NOx-saturated regime, whereas points with ratios between 1 and 4 fall into one or the other regime. We attribute this mainly to the HCHO-NO2 chemical relationship causing the transition line to occur at larger (smaller) HCHO/NO2 ratios in VOC-rich (VOC-poor) environments. We then redefine the transition line to LNOx/LROx~2.7 that accounts for the HCHO-NO2 chemical relationship leading to HCHO = 3.7 × (NO2 – 1.14 × 1016 molec.cm-2). Although the revised formula is locally calibrated (i.e., requires for readjustment for other regions), its mathematical format removes the need for having a wide range of thresholds used in HCHO/NO2 ratios that is a result of the chemical feedback. Therefore, to be able to properly take the chemical feedback into consideration, the use of HCHO = a × (NO2 – b) formula should be preferred to the ratio in future works. We then use the Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) airborne instrument to study O3 sensitivity in Seoul. The unprecedented spatial (250 × 250 m2) and temporal (~every 2 h) resolutions of HCHO and NO2 observations form the sensor enhance our understanding of P(O3) in Seoul; rather than providing a crude label for the entire city, more in-depth variabilities in chemical regimes are observed that should be able to inform mitigation strategies correspondingly.
Glancing Angle Deposition (GLAD) has emerged as a versatile and powerful nanofabrication technique for developing next-generation gas sensors by enabling precise control over nanostructure geometry, porosity, and material composition. Through dynamic substrate tilting and rotation, GLAD facilitates the fabrication of highly porous, anisotropic nanostructures, such as aligned, tilted, zigzag, helical, and multilayered nanorods, with tunable surface area and diffusion pathways optimized for gas detection. This review provides a comprehensive synthesis of recent advances in GLAD-based gas sensor design, focusing on how structural engineering and material integration converge to enhance sensor performance. Key materials strategies include the construction of heterojunctions and core–shell architectures, controlled doping, and nanoparticle decoration using noble metals or metal oxides to amplify charge transfer, catalytic activity, and redox responsiveness. GLAD-fabricated nanostructures have been effectively deployed across multiple gas sensing modalities, including resistive, capacitive, piezoelectric, and optical platforms, where their high aspect ratios, tailored porosity, and defect-rich surfaces facilitate enhanced gas adsorption kinetics and efficient signal transduction. These devices exhibit high sensitivity and selectivity toward a range of analytes, including NO2, CO, H2S, and volatile organic compounds (VOCs), with detection limits often reaching the parts-per-billion level. Emerging innovations, such as photo-assisted sensing and integration with artificial intelligence for data analysis and pattern recognition, further extend the capabilities of GLAD-based systems for multifunctional, real-time, and adaptive sensing. Finally, current challenges and future research directions are discussed, emphasizing the promise of GLAD as a scalable platform for next-generation gas sensing technologies.
Metasurfaces offer a compact platform for optical vapor sensing, but their practical deployment has been limited by weak evanescent light–matter interactions and reliance on spectrally resolved instrumentation. Here, we report porous silicon (pSi) metasurfaces for spectrometer-free quantitative detection of volatile organic compounds (VOCs) with strongly enhanced light–matter interaction. The engineered porosity increases sensitivity by >100× relative to non-porous dielectric metasurfaces, enabling limits of detection of 1.65 ppm for methanol and 9.1 ppm for ethanol across a broad dynamic range (<10 ppm to >103 ppm). Imaging-based readout provides a lightweight, spectrometer-free pathway for real-time quantitative sensing. Beyond quantitative detection, the mesoporous architecture introduces adsorption–desorption kinetics as an additional information channel. Analysis of the resulting spatiotemporal signatures enables kinetic fingerprinting without reliance on infrared spectral features or surface functionalization, and a lightweight machine-learning classifier differentiates acetone, methanol, ethanol, and isopropanol with 91.6% accuracy. These results establish porous metasurfaces as spatiotemporal sensing elements that couple quantitative vapor detection with kinetic fingerprinting through real-time dynamical responses, enabling low-cost, high-performance optical sensors.
Surface ozone (O3) pollution is detrimental to human health, crop yields, and ecosystem productivity. Ground-based ozone observations are sparse and surface ozone retrievals from space are challenging. The process of producing ozone from the oxidation of volatile organic compounds (VOCs) in the presence of nitrogen oxides (NOx) results in formaldehyde (HCHO), which can be observed from satellite and by surface-based remote sensing. From limited field campaign observations, column formaldehyde has been shown to exhibit a strong relationship with surface ozone and, therefore, could be an useful proxy for detecting unmonitored regions of elevated ozone pollution. The spatiotemporal characteristics of this relationship are explored using ground-based Pandora spectrometers and airborne remote sensing data with surface ozone monitors across the United States during recent field campaigns over major cities (TRACER-AQ and STAQS). We extend our analysis to take advantage of HCHO column observations from recently launched Tropospheric Emissions: Monitoring of Pollution (TEMPO), a geostationary satellite over North America. TEMPO observations show preliminary promise in mapping regions of elevated surface ozone from space using column HCHO. We demonstrate the use of column HCHO in assessing the strength of the surface monitoring network, and in detecting the extent of regional ozone exceedances.
The Soberanes Fire burned 132,127 acres along the central California coast between July 22 and October 12, 2016, generating dense smoke and a variety of gaseous compounds that drifted eastward into the San Joaquin Valley Air Basin (SJVAB), an ‘extreme’ non‐attainment area for ozone (O3). These gases included nitrogen oxides (NOx) and volatile organic compounds (VOC), the photochemical precursors of O3. The fire started during the California Baseline Ozone Transport Study (CABOTS), a field campaign that brought aircraft, surface, and remote sensing measurements of O3 and related species to central California. In this paper, we use the CABOTS measurements to assess the impact of the Soberanes Fire on ozone and particulate air quality in the SJVAB. We focus our analysis on July 27 ‐ August 2 when the smoke haze was heaviest and the highest O3 concentrations in the SJVAB during 2016 were recorded. Our analyses suggest that while 40 to 60 ppbv of fire‐generated O3 was transported to the eastern SJVAB in the 1‐3 km altitude range, relatively little smoke or fire‐generated O3 reached the surface in the Visalia area.
We adapted an existing, spaceflight-proven, robust “electronic nose” (E-Nose) that uses an array of electrical resistivity-based nanosensors mimicking aspects of mammalian olfaction to conduct on-site, rapid screening for COVID-19 infection by measuring the pattern of sensor responses to volatile organic compounds (VOCs) in exhaled human breath. We built and tested multiple copies of a hand-held prototype E-Nose sensor system, composed of 64 chemically sensitive nanomaterial sensing elements tailored to COVID-19 VOC detection; data acquisition electronics; a smart tablet with software (App) for sensor control, data acquisition and display; and a sampling fixture to capture exhaled breath samples and deliver them to the sensor array inside the E-Nose. The sensing elements detect the combination of VOCs typical in breath at parts-per-billion (ppb) levels, with repeatability of 0.02% and reproducibility of 1.2%; the measurement electronics in the E-Nose provide measurement accuracy and signal-to-noise ratios comparable to benchtop instrumentation. Preliminary clinical testing at Stanford Medicine with 63 participants, their COVID-19-positive or COVID-19-negative status determined by concomitant RT-PCR, discriminated between these two categories of human breath with a 79% correct identification rate using “leave-one-out” training-and-analysis methods. Analyzing the E-Nose response in conjunction with body temperature and other non-invasive symptom screening using advanced machine learning methods, with a much larger database of responses from a wider swath of the population, is expected to provide more accurate on-the-spot answers. Additional clinical testing, design refinement, and a mass manufacturing approach are the main steps toward deploying this technology to rapidly screen for active infection in clinics and hospitals, public and commercial venues, or at home.
Reactive health monitoring strategies during events like the COVID-19 pandemic highlighted the need for predictive, threat-agnostic diagnostics that can detect both known diseases and novel chemical or biological threats. To address this, we investigated an optical biosensor as a breath volatile organic compound (VOC) analyzer, aiming to emulate biological olfaction. We assembled and validated the device with thin film metal coated substrate-based sensors. We immobilized small biological recognition elements on the substrates and delivered controlled concentrations of target VOCs. The sensor was irradiated with a visible laser and the sensor signal was recorded. We characterized the laser performance and tested 3 recognition elements for 2 VOCs with varying concentrations (1-100 ppm). We also evaluated enhancement of the signal using nanostructures on the metal film in comparison with planar film substrate. We demonstrated detecting ethanol reliably at concentrations as low as ~2 ppm along with preliminary detection of acetone (<100 ppm). We also found several unexpected factors that influence the sensor behavior that should be addressed to further refine the device’s performance. The nanostructures were, as expected, found to amplify the sensor signals. These findings demonstrate the feasibility of the optical bio-sensing modality for breath VOC monitoring at physiologically relevant levels. This positions LLNL to develop a low-cost, scalable, broad-spectrum health monitoring capability aligned with the Early Detection thrust of the Bioresilience Mission Focus Area and attract external funding.
Surface-level ozone (O3) pollution mitigation strategies rely on a clear understanding of the atmospheric chemical processes involving O3, NOx (nitric oxide (NO) + nitrogen dioxide (NO2)) and volatile organic compounds (VOCs). A robust spatiotemporal classification of O3 photochemical regimes with relative chemical sensitivity of local O3 formation to emission reductions of NOx (NOx-limited regime) versus VOCs (radical-limited regime) is required to design anthropogenic emission reduction policies in order to improve surface air quality. Numerous studies found that the ratio of satellite-retrieved Vertical Column Densities (VCDs) of formaldehyde (HCHO) to NO2 can diagnose O3 production sensitivity. However, uncertainty still remains about the accuracy of such estimates using satellite-based retrievals. This study conducts an investigation to identify how well satellite data can inform surface-level O3 sensitivity by validating satellite-based estimates against aircraft-based retrievals taken during the Long Island Sound Tropospheric Ozone Study (LISTOS-2018) and Ozone Water-Land Environmental Transition Study (OWLETS-2) field campaigns. For this study, we use HCHO and NO2 retrievals from the Ozone Monitoring Instrument (OMI) onboard the Aura satellite, and high spatiotemporal resolution TROPOspheric Monitoring Instrument (TROPOMI) onboard the Sentinel-5 Precursor (S5P) satellite. The Community Multiscale Air Quality (CMAQ) modelling system is used to provide trace gas vertical profiles to recalculate air mass factor for deriving consistent satellite-based VCDs. To demonstrate the ability of satellites to diagnose O3 production regimes, we validate satellite-derived O3 sensitivity regimes, along with the OMI and TROPOMI products applied, using HCHO and NO2 retrievals from the aircraft-based instruments: Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) spectrometer and Geostationary Coastal and Air Pollution Events Airborne Simulator (GCAS) instruments deployed during the LISTOS-2018 and OWLETS-2 campaigns. The results of this work will advance our fundamental knowledge of the spatiotemporal evolution of the complex O3-NOx-VOC chemistry, and will advance our understanding about the quality of remote-sensing, suborbital, and satellite data for accurately observing surface-level O3 production sensitivity.
Organic aerosol (OA) is one of the main components of the global particulate burden and intimately links natural and anthropogenic emissions with air quality and climate. It is challenging to accurately represent OA in global models. Direct quantification of global OA abundance is not possible with current remote sensing technology; however, it may be possible to exploit correlations of OA with remotely observable quantities to infer OA spatiotemporal distributions. In particular, formaldehyde (HCHO) and OA share common sources via both primary emissions and secondary production from oxidation of volatile organic compounds (VOCs). Here, we examine OA–HCHO correlations using data from summertime airborne campaigns investigating biogenic (NASA SEAC4RS and DC3), biomass burning (NASA SEAC4RS), and anthropogenic conditions (NOAA CalNex and NASA KORUS-AQ). In situ OA correlates well with HCHO (r=0.59–0.97), and the slope and intercept of this relationship depend on the chemical regime. For biogenic and anthropogenic regions, the OA–HCHO slopes are higher in low NOx conditions, because HCHO yields are lower and aerosol yields are likely higher. The OA–HCHO slope of wildfires is over 9 times higher than that for biogenic and anthropogenic sources. The OA–HCHO slope is higher for highly polluted anthropogenic sources (e.g., KORUS-AQ) than less polluted (e.g., CalNex) anthropogenic sources. Near-surface OAs over the continental US are estimated by combining the observed in situ relationships with HCHO column retrievals from NASA's Ozone Monitoring Instrument (OMI). HCHO vertical profiles used in OA estimates are from climatology a priori profiles in the OMI HCHO retrieval or output of specific period from a newer version of GEOS-Chem. Our OA estimates compare well with US EPA IMPROVE data obtained over summer months (e.g., slope =0.60–0.62, r=0.56 for August 2013), with correlation performance comparable to intensively validated GEOS-Chem (e.g., slope =0.57, r=0.56) with IMPROVE OA and superior to the satellite-derived total aerosol extinction (r=0.41) with IMPROVE OA. This indicates that OA estimates are not very sensitive to these HCHO vertical profiles and that a priori profiles from OMI HCHO retrieval have a similar performance to that of the newer model version in estimating OA. Improving the detection limit of satellite HCHO and expanding in situ airborne HCHO and OA coverage in future missions will improve the quality and spatiotemporal coverage of our OA estimates, potentially enabling constraints on global OA distribution.
We present a novel capability in satellite remote sensing with implications for air pollution control strategy. We show that the ratio of formaldehyde columns to tropospheric nitrogen dioxide columns is an indicator of the relative sensitivity of surface ozone to emissions of nitrogen oxides (NO(x) = NO + NO2) and volatile organic compounds (VOCs). The diagnosis from these space-based observations is highly consistent with current understanding of surface ozone chemistry based on in situ observations. The satellite-derived ratios indicate that surface ozone is more sensitive to emissions of NO(x) than of VOCs throughout most continental regions of the Northern Hemisphere during summer. Exceptions include Los Angeles and industrial areas of Germany. A seasonal transition occurs in the fall when surface ozone becomes less sensitive to NOx and more sensitive to VOCs.
Land use and land cover maps of Atlanta Metropolitan Area in Georgia were produced from Landsat MSS and TM images for 1973,1979,1983,1987,1992, and 1997, spanning a period of 25 years. Dramatic changes in land use and land cover have occurred with loss of forest and cropland to urban use. In particular, low-density urban use, which includes largely residential use, has increased by over 119% between 1973 and 1997. These land use and land cover changes have drastically altered the land surface characteristics. An analysis of Landsat images revealed an increase in surface temperature and a decline in NDVI from 1973 to 1997. These changes have forced the development of a significant urban heat island effect and an increase in ground level ozone production to such an extent, that Atlanta has violated EPA's ozone level standard in recent years. The urban heat island initiated precipitation events that were identified between 1996 and 2000 tended to occur near high-density urban areas but outside the I-285 loop that traverses around the Central Business District, i.e. not in the inner city area, but some in close proximity to the highways. The health implications were investigated by comparing the spatial patterns of volatile organic compounds (VOC) and nitrogen oxides (NOx) emissions, the two ingredients that form ozone by reacting with sunlight, with those of rates of cardiovascular and chronic lower respiratory diseases. A clear core-periphery pattern was revealed for both VOC and NOx emissions, but the spatial pattern was more random in the cases of rates of cardiovascular and chronic lower respiratory diseases. Clearly, factors other than ozone pollution were involved in explaining the rates of these diseases. Further research is therefore needed to understand the health geography and its relationship to land use and land cover change as well as urban heat island effect. This paper illustrates the usefulness of a remote sensing approach for this purpose.
The volatile organic compounds (VOCs) in a wide spectrum of categories were identified as biomarkers in aquatic environments, playing an important role in marine and freshwater ecology and global atmospheric chemistry. VOCs released from biofuel have also attracted increasing attention. Although the importance has been recognized, the portable detection and analysis methods of VOC in aquatic systems have not yet been well developed and understood. Here, in this work, we innovatively proposed an intelligent electrochemical sensing approach to classify and quantify VOCs in solution. Utilizing the cyclic voltammetry (CV) method with an ionic liquid (IL)-based electrolyte, we analyzed 50 μL samples of various VOC analytes, including acetic acid (AC), acetone, dimethylformamide (DMF), dimethyl sulfoxide (DMSO), ethanol, formaldehyde, formic acid, methanol, methyl formate (MF), toluene, and a formaldehyde-methanol mixture, along with deionized water (DI water). The generated voltammograms were subsequently analyzed using our uniquely designed and optimized 1-D convolutional neural network (1D-CNN). This deep-learning algorithm achieved a 99.09% accuracy in VOC classification validated through fivefold cross-validation and demonstrated an impressive 94.4% test accuracy for methanol detection within a 10 μL error range. For quantification, the system accurately categorized methanol volumes ranging from 0 to 50 μL in 10 μL increments, achieving a 98.18% accuracy. A notable linear correlation (R2 = 95.56%) was found between max current density at the oxidation peak and methanol volume, with the limit of detection (LOD) at 9.3 μL. Such a sensing method exhibits potential for portability, high accuracy, and generalization in the classification and quantification, ultimately reshaping the realm of VOC analysis in solution.
To aid in the detection of harmful aerosols and trace gases emitted in wildfires and prescribed burns, we are designing a smoke-specific payload which can be flown on the Black Swift S2™ Uncrewed Aerial System (UAS) platform. The payload will be custom and mounted within the nosecone, equipped with a trace gas sensor suite and particle spectrometer for characterization of wildfire and prescribed burn emissions. This data will aid in the improvement of HYSPLIT3 modeling to make more informed decisions regarding prescribed burns, particularly for mountain valleys in the Pacific Northwest. The trace gas suite will be composed of 8 low-cost trace gas sensors (CH4, CO2, CO, HCN, NO2, NO, O3, and Volatile Organic Compounds (VOCs)). Portable Optical Particle Spectrometer (POPS) measures particle size range between 0.14 to 3 µm, which is crucial for assessing public health impact, air quality, and visibility.
Efforts to observe near-surface ozone directly from space are hindered by the limited sensitivity of ozone satellite retrievals to the lower troposphere. Formaldehyde (HCHO) column observations from the NASA DISCOVER-AQ campaign showed a strong relationship with surface ozone, particularly when biogenic volatile organic compounds (VOCs) were the dominant ozone precursor due to their strong temperature-driven variability. Both tropospheric ozone and HCHO are secondarily produced through the oxidation of VOCs and in regions where the main fate of RO2 is reaction with NO, thus formaldehyde and ozone are generally co-produced. This work explores the relationship between column formaldehyde and surface ozone using data from two air quality research campaigns, the Long Island Sound Tropospheric Ozone Study (LISTOS) in 2018 and the Korea U.S. - Air Quality (KORUS-AQ) campaign in 2016. These campaigns included HCHO column information from airborne in-situ profiling and remote sensing and ground-based Pandora spectrometers in combination with surface ozone monitors in each region. These data are used to further explore the HCHO-ozone relationship and its potential for identifying areas of elevated ozone using remote sensing or satellite observations of column HCHO alone. These two regions offer a valuable comparison given their different VOC mixtures and the higher NOx levels in Seoul that result in ozone titration effects. This work will also address the potential for this application with future geostationary satellite observations.
Volatile organic compounds (VOCs) inevitably accumulate in enclosed habitats such as the International Space Station and the Crew Exploration Vehicle (CEV) as a result of human metabolism, material off-gassing, and leaking equipment. Some VOCs can negatively affect the quality of the crew's life, health, and performance; and consequently, the success of the mission. Air quality must be closely monitored to ensure a safe living and working environment. Currently, there is no reliable air quality monitoring system that meets NASA's stringent requirements for power, mass, volume, or performance. The ultimate objective of the project -- the development of a Real-Time, Miniaturized, Autonomous Total Risk Indicator System (RT.MATRIX).is to provide a portable, dual-function sensing system that simultaneously determines total organic carbon (TOC) and individual contaminants in air streams.
Detection and analysis of volatile organic compounds' (VOCs) biomarkers lead to improvement in healthcare diagnosis and other applications such as chemical threat detection and food quality control. Here, we report on tri-molybdenum phosphide (Mo3P) and multiwalled carbon nanotube (MWCNT) junction-based vapor quantum resistive sensors (vQRSs), which exhibit more than one order of magnitude higher sensitivity and superior selectivity for biomarkers in comparison to pristine MWCNT junctions based vQRSs. Transmission electron microscope/scanning tunneling electron microscope with energy dispersive x-ray spectroscopy, x-ray diffraction, and x-ray photoelectron spectroscopy studies reveal the crystallinity and the presence of Mo and P elements in the network. The presence of Mo3P clearly enhanced the performance of vQRS as evidenced in sensitivity and selectivity studies. The vQRSs are stable over extended periods of time and are reproducible, making them a potential candidate for sensing related applications.