Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage improvement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Magnetic insulation to improve voltage holding in electrostatic accelerators

Voltage holding in high voltage electrostatic accelerators is a longstanding problem which limits the practically obtainable performance of most systems. This paper proposes an idea for improving the voltage holding in electrostatic accelerators by suppressing breakdowns between successive stages of an accelerator. The idea consists of flowing electric currents along the accelerator electrodes to produce magnetic fields which envelope each electrode and its support structure, so as to prevent very low energy electrons from leaving the surfaces of electrodes and subsequently picking up energy from the electric field. In order to be useful in some applications, this magnetic insulation would only need to produce modest gains in voltage holding capability, and its utility can be easily tested experimentally as described herein.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Method for improved voltage determination for pulsed power systems utilizing a magnetically insulated transmission line

Because the voltage is difficult to measure in a magnetically insulated transmission line (MITL), measurement of the currents flowing in the cathode and anode are often used with MITL theory to estimate the voltage in a given experiment. However, that estimate contains a space charge correction term whose magnitude depends on what is referred to as the g factor that describes the distribution of charge and current in the electron flow layer in the MITL. Typically, g is on the order of unity but the accuracy of the voltage estimate depends on its actual value. While the space charge correction term is small when the MITL flow is strongly insulated, it is particularly important near self-limited MITL flow. System parameters that affect the distribution of electron flow are studied here at self-limited flow in order to illustrate this matter and develop a methodology to improve the voltage determination.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Model Predictive Voltage Control of Large-Scale PV or Hybrid PV-BESS Plants

Increased penetration level of inverter-based resources (IBRs) and renewable energy in the power grid has called for more requirements from the control of IBRs. In this paper, the voltage-reactive power control of a photovoltaic (PV) power plant or hybrid PV-battery energy storage system (BESS) plant connected to a bulk power grid, whilst meeting the grid requirements, is studied. In this paper, a continuous-set model predictive control (MPC) formulation is proposed for voltage-reactive power control. For the same, an aggregated dynamic PV plant model is developed based on the recursive system equivalencing method. The formulation is then implemented in PSCAD simulation on a 125 MW PV plant or hybrid PV-BESS plant. The MPC implementation achieves 10.13% voltage improvement based on PSCAD simulation results in a balanced fault case study. Simulation results further demonstrate that MPC provides improved voltage support over the conventional proportional-integral (PI) controller post-fault occurrence.

Abu rub, Omar↗

The Impact of Transformer Winding Connections of A Grid-Connected PV on Voltage Quality Improvement

In this paper, the high-power PV plant is connected to the weak grid by means of a three-phase power transformer. The selection of transformer winding connection is critical especially when the PV inverter has a reactive power controller. In general, transformer winding connection can be arranged in star-star (with neutral earthed) or star-delta. The reactive power controller supports voltage regulation of the power system particularly under transient faults. Its control strategy is based on utilizing the grid currents to make a three-phase reactive unbalanced current with a small gain. The gain is determined by the system impedance. Simulation results exhibit that the control strategy works very well particularly under disturbance conditions when the transformer winding connection is star-star with both neutrals grounded. The power quality in terms of the voltage quality is improved.

14 SOLAR ENERGY↗

Improvement of voltage holding and high current beam acceleration by MeV accelerator for ITER NB

Voltage holding of -1 MV is an essential issue in development of a multi-aperture multi-grid (MAMuG) negative ion accelerator, of which target is to accelerate 200 A/m{sup 2} H{sup -} ion beam up to the energy of 1 MeV for several tens seconds. Review of voltage holding results ever obtained with various geometries of the accelerators showed that the voltage holding capability was about a half of designed value based on the experiment obtained from ideal small electrode. This is considered due to local electric field concentration in the accelerators, such as edge and steps between multi-aperture grids and its support structures. Based on the detailed investigation with electric field analysis, accelerator was modified to reduce the electric field concentration by reshaping the support structures and expanding the gap length between the grid supports. After the modifications, the accelerator succeeded in sustaining -1 MV for more than one hour in vacuum. Improvement of the voltage holding characteristics progressed the energy and current accelerated by the MeV accelerator. Up to 2010, beam parameters achieved by the MAMuG accelerator were increased to 879 keV, 0.36 A (157 A/m{sup 2}) at perveance matched condition and 937 keV, 0.33 A (144 A/m{sup 2}) slightly under perveance.

43 PARTICLE ACCELERATORS↗

The physical mechanism on the threshold voltage temperature stability improvement for GaN HEMTs with pre-fluorination argon treatment

In this paper, a normally-off AlGaN/GaN MIS-HEMT with improved threshold voltage (V{sub TH}) thermal stability is reported with investigations on its physical mechanism. The normally-off operation of the device is achieved from novel short argon plasma treatment (APT) prior to the fluorine plasma treatment (FPT) on Al{sub 2}O{sub 3} gate dielectrics. For the MIS-HEMT with FPT only, its V{sub TH} drops from 4.2 V at room temperature to 0.5 V at 200 °C. Alternatively, for the device with APT-then-FPT process, its V{sub TH} can retain at 2.5 V at 200 °C due to the increased amount of deep-level traps that do not emit electrons at 200 °C. This thermally stable V{sub TH} makes this device suitable for high power applications. The depth profile of the F atoms in Al{sub 2}O{sub 3}, measured by the secondary ion mass spectroscopy, reveals a significant increase in the F concentration when APT is conducted prior to FPT. The X-ray photoelectron spectroscopy (XPS) analysis on the plasma-treated Al{sub 2}O{sub 3} surfaces observes higher composition of Al-F bonds if APT was applied before FPT. The enhanced breaking of Al-O bonds due to Ar bombardment assisted in the increased incorporation of F radicals at the surface during the subsequent FPT process. The Schrödinger equation of Al{sub 2}O{sub x}F{sub y} cells, with the same Al-F compositions as obtained from XPS, was solved by Gaussian 09 molecular simulations to extract electron state distribution as a function of energy. The simulation results show creation of the deeper trap states in the Al{sub 2}O{sub 3} bandgap when APT is used before FPT. Finally, the trap distribution extracted from the simulations is verified by the gate-stress experimental characterization to confirm the physical mechanism described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improvement of voltage holding capability in the 500 keV negative ion source for JT-60SA

Voltage holding capability of JT-60 negative ion source that has a large electrostatic negative ion accelerator with 45 cmx1.1 m acceleration grids was experimentally examined and improved to realize 500 keV, 22 A, and 100 s D{sup -} ion beams for JT-60 Super Advanced. The gap lengths in the acceleration stages were extended to reduce electric fields in a gap between the large grids and at the corner of the support flanges from the original 4-5 to 3-4 kV/mm. As a result, the voltage holding capability without beam acceleration has been successfully improved from 400 to 500 kV. The pulse duration to hold 500 kV reached 40 s of the power supply limitation.

43 PARTICLE ACCELERATORS↗

Local Phasor-Based Control of DER Inverters for Voltage Regulation on Distribution Feeders

We introduce a new control paradigm termed Phasor-Based Control (PBC) to coordinate Distributed Energy Resources (DER) for improved voltage regulation and other objectives. PBC is a multi-layer control framework where the state of the distribution grid is represented by voltage phasors, and Phasor Measurement Units (PMUs) measure the state at critical points in the distribution grid. In the PBC paradigm, a supervisory controller (S-PBC) sets phasor targets which local controllers track. In this paper, we propose a Proportional Integral (PI) implementation for the local control layer (LPBC), to regulate real and reactive power output of distributed inverters to track a voltage phasor target computed by the supervisory layer. We tune the PI controller gains offline with a genetic algorithm that yields better performance than the Ziegler-Nichols method. We benchmark the proposed L-PBC controller against droop volt-var control (DVVC) and observe improved voltage regulation in simulation on the IEEE 13 node unbalanced test feeder (IEEE 13NF). Furthermore, by means of numerical simulation we observe the response of the L-PBC controllers to small and large grid disturbances. Simulations on larger feeders, IEEE 123-node and 647-node, demonstrate challenges with tuning controllers in setups with different amounts of power-voltage coupling.

42 ENGINEERING↗

Improved forward voltage and external quantum efficiency scaling in multi-active region III-nitride LEDs

Ultra-low voltage drop tunnel junctions (TJs) were utilized to enable multi-active region blue light emitting diodes (LEDs) with up to three active regions in a single device. The multi-active region blue LEDs were grown monolithically by metal-organic chemical vapor deposition (MOCVD) without growth interruption. This is the first demonstration of a MOCVD grown triple-junction LED. Optimized TJ design enabled near-ideal voltage and EQE scaling close to the number of junctions. Furthermore, this work demonstrates that with proper TJ design, improvements in wall-plug efficiency at high output power operation are possible by cascading multiple III-nitride based LEDs.

42 ENGINEERING↗

Tailoring the surface properties of LiNi 0.4 Mn 0.4 Co 0.2 O₂ by titanium substitution for improved high voltage cycling performance

The present research aims to provide insights into the behavior of LiNi0.4Mn0.4Co0.2O2 (NMC442) and LiNi 0.4 Mn 0.4 Co 0.2 O₂ (NMC442-Ti02) cathode materials under galvanostatic cycling to high potentials, in the context of previous work which predicted that Ti-substituted variants should deliver higher capacities and exhibit better cycling stability than the unsubstituted compounds. It is found that NMC cathodes containing Ti show equivalent capacity fading but greater specific capacity than those without Ti in the same potential range. When repeatedly charged to the same degree of delithiation, NMC cathodes containing Ti showed better capacity retention. Soft x-ray absorption spectroscopy (XAS) spectra for Mn and Co indicated increased reduction in these elements for NMC cathodes without Ti, indicating that the substitution of Ti for Co acts to suppress the formation of a high impedance rock salt phase at the surface of NMC cathode particles. The results of this study validate the adoption of a facile change to existing NMC chemistries to improve cathode capacity retention under high voltage cycling conditions.

36 MATERIALS SCIENCE↗

Anomaly Detection and Mitigation in FACTS-based Wide-Area Voltage Control Systems using Machine Learning

With the increasing deployment of Flexible AC Transmission System (FACTS) devices in wide-area voltage control systems (WAVCS) for achieving improved voltage stability of bulk power systems, the possibility for cyber attacks on these systems is also increasing. Successful stealthy cyber attacks that are difficult to detect by traditional informational technology (IT)-based cybersecurity solutions or threshold-based bad data detectors can lead to a voltage collapse in power grid. This paper presents the testbed-based attacks implementation and real-time evaluation of machine learning (ML) algorithm for detecting and mitigating stealthy cyber attacks on FACTS-based WAVCS on a hardware-in-the-loop (HIL) testbed. Initially, we discuss the implementation of a fuzzy logic controller (FLC) that controls a Static VAR Compensator (SVC) device deployed in a two-area four-machine Kundur power system for improving transient voltage stability. Later, the ML-based Anomaly Detection and Mitigation (ADM) system is implemented on the cyber-physical HIL testbed to detect and mitigate various stealthy cyber attacks, which are injected in real-time over the wide-area network (WAN). The experimental results show accurate and effective performance of ADM system in detecting and mitigating anomalies while keeping the grid stable and within the system operating limits, as defined by the North America Electric Reliability Corporation (NERC).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Artificial cathode electrolyte interphase for improving high voltage cycling stability of thick electrode with Co-free 5 V spinel oxides

Spinel-type cathode LiNi 0.5 Mn 1.5 O 4 (LNMO) has intrigued the transportation industry due to its high operating voltage and total elimination of the expensive cobalt element. However, LNMO cathode with high mass loading (> 3 mAh/cm 2 in areal capacity) has suffered from excessive capacity degradation upon long cycling. Here, a robust Al 2 O 3 surface layer is introduced to the thick LNMO electrode via atomic layer deposition (ALD). The capacity retention in full cells with the graphite anode is improved from 46.3% to 75.3% after 300 cycles with cutoff voltage up to 4.85 V, while enabling average Coulombic efficiency of 99.9% during the cycling. The post-mortem analyses reveal that the Al 2 O 3 surface layer would convert to Al-O-F /Al-F species upon cycling, offering stable interphase to protect the cathode material. Furthermore, these results demonstrate the significance of surface modification enabling high voltage cathode for next-generation LIBs.

25 ENERGY STORAGE↗

Hierarchical Control Scheme for Improving Transient Voltage Recovery of a DFIG-Based WPP

Modern grid codes require that wind power plants (WPPs) inject reactive power according to the voltage dip at a point of interconnection (POI). This requirement helps to support a POI voltage during a fault. However, if a fault is cleared, the POI and wind turbine generator (WTG) voltages are likely to exceed acceptable levels unless the WPP reduces the injected reactive power quickly. This might deteriorate the stability of a grid by allowing the disconnection of WTGs to avoid any damage. This paper proposes a hierarchical control scheme of a doubly-fed induction generator (DFIG)-based WPP. The proposed scheme aims to improve the reactive power injecting capability during the fault and suppress the overvoltage after the fault clearance. To achieve the former, an adaptive reactive power-to-voltage scheme is implemented in each DFIG controller so that a DFIG with a larger reactive power capability will inject more reactive power. To achieve the latter, a washout filter is used to capture a high frequency component contained in the WPP voltage, which is used to remove the accumulated values in the proportional-integral controllers. Test results indicate that the scheme successfully supports the grid voltage during the fault, and recovers WPP voltages without exceeding the limit after the fault clearance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptation of Commercial Current-Controlled Inverters for Operation with Virtual Oscillator Control

Virtual oscillator control (VOC) is a decentralized time-domain control technique for ac microgrids where inverters are regulated to emulate the dynamics of weakly nonlinear oscillators. VOC enables the design of modular and scalable systems where inverters can synchronize and share power without communication and in near real-time. In this paper, we show how off-the-shelf commercial inverters with current control can be reprogrammed to behave as voltage sources with virtual oscillator dynamics for deployment in islanded settings. We focus on commercial grid-tied inverters that have an inner current-control loop and show how the outer-loop controls can be straightforwardly modified to enable voltage-control-mode operation. To illustrate the practicality and ease of our approach, the proposed strategy was implemented on a 3.2 kVA experimental test bed composed of 10 SunPower-brand micro-inverters with special firmware for VOC implementation. Results from the experiments not only demonstrate feasibility of the proposed dual-loop VOC architecture on a hardware setup but also show improved voltage regulation due to the additional voltage control loop.

24 POWER TRANSMISSION AND DISTRIBUTION↗