Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage mitigation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Hardening communication ports for survival in electrical overstress environments

Greater attention is being focused on the protection of data I/O ports since both experience and lab tests have shown that components at these locations are extremely vulnerable to electrical overstress (EOS) in the form of transient voltages. Lightning and electrostatic discharge (ESD) are the major contributors to these failures; however, these losses can be prevented. Hardening against transient voltages at both the board level and system level has a proven record of improving reliability by orders of magnitude. The EOS threats, typical failure modes, and transient voltage mitigation techniques are reviewed. Case histories are also reviewed.

Clark, O. Melville↗

AC and DC Fault Management for Megawatt Electrified Aircraft Electrical Powertrains - Task 2: Power Quality Filtering Using Nanocrystalline Soft Magnetic Inductor

The NASA RTAPS program on AC and DC Fault Management for Megawatt Electrified Power Train is a multi-year joint project with Pratt & Whitney (P&W), Collins Aerospace (CA), and RTX Technology Research Center (RTRC). This research program focuses on the high-voltage distribution issues that present a significant technological obstacle in the adoption of Electrified Aviation Propulsion (EAP) systems. One challenge to the adoption of high-voltage distribution systems with power electronic converters is the need for filter elements to limit the generation and propagation of noise, protect the cable systems from premature aging and prevent against excessive heating within subcomponents due to high-frequency induced currents. While increased distribution voltages aide in reducing the cable mass for a fixed power system, the associated mass with the filtering elements for power electronic converter can grow with increasing distribution voltages – thereby mitigating any benefit associated with increasing the distribution system voltage. To enable high-voltage distribution systems with high system specific power densities, new magnetic materials must be developed. Therefore, the second task of the NASA RTAPS program is associated with the design and application of advanced soft magnetic components for Megawatt class electric propulsion systems, specifically the motor drive system. This report covers the collaborative work between NASA Glenn Research Center (GRC), RTRC, P&W and CA in the development of three types of magnetic components over the span of the three-year program. These critical magnetic components are the DC side EMI filter, which limits the propagation of harmful electromagnetic noise to the rise of the distribution system, and the AC side damping with the dv/dt filter, which limits the fast rise time of the power electronic converter output voltage to limit the degradation on the cable/motor insulation systems. Each of these components are investigated from component level design and are optimized at the system level with a combined modelling and testing effort. In the final experimental evaluation of the NASA developed soft magnetic material with a dv/dt filter, a commercial-off-the-shelf (COTS) magnetic core and the GRC magnetic core are optimized and loaded at 320Arms to evaluate their difference in performance. After a run time of 30 minutes in a MW-class motor driver at RTRC, the NASA GRC cores were found to not only offer a lower temperature rise of nearly 25°𝐶, but also a reduction in measured core loss of 25% (12.75W to 9.5W).

Elecrified Aircraft Propulsion↗

Reverse bias protected solar array with integrated bypass battery

A method for protecting the photovoltaic cells in a photovoltaic (PV) array from reverse bias damage by utilizing a rechargeable battery for bypassing current from a shaded photovoltaic cell or group of cells, avoiding the need for a bypass diode. Further, the method mitigates the voltage degradation of a PV array caused by shaded cells.

Landis, Geoffrey A↗

Modeling and Mitigation of dv/dt and Transmission Line Effect for Motor Drive System in Electric Aircraft Propulsion

Due to constraints in space and structure as well as other practical limitations in aircraft system, the motor controller or electric motor are often installed far away from each other and interconnected via long cables. This amplifies the transmission line effect excited by the dv/dt PWM voltage and induces high voltage stress on the machine winding. This paper investigates the state-of-art modeling approaches for such systems, identifies several limitations in matching the tested voltage reflection waveform in terms of peak voltage, oscillation frequency and damping speed, and offers several key considerations not well covered in literature or in engineering practice. It then proposes a practical modeling methodology which, as validated by experimental results, truly captures these critical reflection voltage specs. To mitigate the high peak voltage and strong oscillation, dv/dt filter is applied and a parametric design optimization based on widely adopted LC-R topology is illustrated, which not only alleviates the voltage stress but also minimized the power loss of the passive damping resistor.

Inductor↗

Plasma Perturbations in High-Speed Probing of Hall Thruster Discharge Chambers: Quantification and Mitigation

An experimental investigation is presented to quantify the effect of high-speed probing on the plasma parameters inside the discharge chamber of a 6-kW Hall thruster. Understanding the nature of these perturbations is of significant interest given the importance of accurate plasma measurements for characterizing thruster operation. An array of diagnostics including a high-speed camera and embedded wall probes is employed to examine in real time the changes in electron temperature and plasma potential induced by inserting a high-speed reciprocating Langmuir probe into the discharge chamber. It is found that the perturbations onset when the scanning probe is downstream of the electron temperature peak, and that along channel centerline, the perturbations are best characterized as a downstream shift of plasma parameters by 15-20% the length of the discharge chamber. A parametric study is performed to investigate techniques to mitigate the observed probe perturbations including varying probe speed, probe location, and operating conditions. It is found that the perturbations largely disappear when the thruster is operated at low power and low discharge voltage. The results of this mitigation study are discussed in the context of recommended methods for generating unperturbed measurements of the discharge chamber plasma.

Jorns, Benjamin A.↗

Artemis IV Docking in Radiation Belt Charging Environment

NASA’s Artemis IV mission is planned to deliver the International Habitation Module (I-Hab) to the Gateway space station in lunar orbit. The I-Hab will be launched aboard the Space Launch System (SLS) vehicle as a co-manifested payload with the Orion spacecraft. After translunar injection begins, the Orion spacecraft will separate from the SLS Exploration Upper Stage (EUS) and then dock with the I-Hab to extract it from the EUS. Because of the altitude, orientation, and time for this to occur, the vehicle-to-vehicle potential between the I-Hab/EUS vehicle and Orion spacecraft could exceed several thousand volts. The docking of these two spacecrafts with such large differential potentials presents a challenge for the vehicles. This presentation describes the space environments at the docking altitude, the calculated vehicle-to-vehicle potential, and the possible impacts of the resulting voltage and current transients occurring at first contact. Additionally, possible risk mitigation tests to demonstrate compatibility with the transient current and voltages will be presented.

Matthew Mccollum↗

The Effects of Background Pressure on SPT-140 Thruster Performance at Multiple Power Levels

NASA's planned Psyche mission is scheduled to launch in 2022 and begin a 3.5-year cruise to the metallic asteroid Psyche, where it would examine this unique body. The baseline spacecraft design is a hybrid of JPL's deep-space heritage subsystems with commercial partner SSL's power, structure, and SPT-140 electric propulsion subsystems. Since the deep-space implementation of the SPT-140 differs from the commercial implementation, primarily in the need for deep power throttling, characterization of the system at lower powers is necessary. One specific area of interest is the sensitivity of thruster performance to background pressure in ground-based test facilities, which can have an impact on the prediction of in-space performance. Measurements of this pressure dependence were performed on a qualification-model SPT-140 thruster over the 0.9-4.5 kW range of interest for the Psyche mission. Thrust sensitivity to pressure, in an absolute sense, was largest at 4.5 kW and decreased with power until there was little-to-no measurable effect at 0.9 kW. In a relative sense, thrust sensitivity was similar at all powers above 0.9 kW with about 2-4% higher thrust measured at 10 μTorr than at the lowest operating pressure. Thruster stability margin, examined as a function of magnet current, did not have a strong dependence on facility pressure. Finally, an investigation of low-power operation at the lowest facility pressure showed that a combination of added cathode keeper current and additional cathode propellant flow significantly mitigated the larger negative cathode-to-ground voltages that were observed. These test results, combined with thruster life test results, inform the selection of proper low-power operating conditions for Psyche.

Snyder, John S.↗

The Effects of Background Pressure on SPT-140 Hall Thruster Performance

NASA’s planned Psyche mission is scheduled to launch in 2022 and begin a 3.5-year cruise to the metallic asteroid Psyche, where it would examine this unique body. The baseline spacecraft design is a hybrid of JPL’s deep-space heritage subsystems with commercial partner SSL’s power, structure, and SPT-140 electric propulsion subsystems. Since the deepspace implementation of the SPT-140 differs from the commercial implementation, primarily in the need for deep power throttling, characterization of the system at lower powers is necessary. One specific area of interest is the sensitivity of thruster performance to background pressure in ground-based test facilities, which can have an impact on the prediction of in-space performance. Measurements of this pressure dependence were performed on a qualification-model SPT-140 thruster over the 0.9-4.5 kW range of interest for the Psyche mission. Thrust sensitivity to pressure, in an absolute sense, was largest at 4.5 kW and decreased with power until there was little-to-no measurable effect at 0.9 kW. In a relative sense, thrust sensitivity was similar at all powers above 0.9 kW with about 2-4% higher thrust measured at 10 µ µTorr than at the lowest operating pressure. Thruster magnetic field sensitivity, examined as a function of magnet current, did not have a strong dependence on facility pressure. Finally, an investigation of low-power operation at the lowest facility pressure showed that a combination of added cathode keeper current and additional cathode propellant flow significantly mitigated the larger negative cathode-to-ground voltages that were observed. These test results, combined with thruster life test results, inform the selection of proper low-power operating conditions for Psyche.

Mackey, Jonathan A.↗

Stress-Dependent Voltage Offsets From Polymer Insulators Used in Rock Mechanics and Material Testing

Dielectric insulators are used in a variety of laboratory settings when performing experiments in rock mechanics, petrology, and electromagnetic studies of rocks in the fields of geophysics,material science, and civil engineering. These components may be used to electrically isolate geological samples from the experimental equipment, to perform a mechanical compliance function between brittle samples and the loading equipment, to match ultrasonic transducers, or perform other functions. In manyexperimental configurations the insulators bear the full brunt of force applied to the sample but do not need to withstand high voltages, therefore the insulators are often thin sheets of mechanically tough polymers. From an instrument perspective, transduction from various types of mechanical perturbation has beenqualitatively compared for a number of polymers [1, 2] and these error sources are readily apparent duringhigh-impedance measurements if not mitigated. However even when following best practices, a force dependent voltage signal still remains and its behavior is explored in this presentation. In this experimenttwo thin sheets (0.25 mm) of high-density polyethylene (HDPE) were set up in a stack, held alternatelybetween three aluminum bars; this stack was placed on the platen of a 60T capacity hydraulic testingmachine. The surface area, A, over which the force is applied to the PE sheets in this sandwich is roughly 40 square cm, each sheet forming a parallel-plate capacitor having roughly 320 pF [3], assuming therelative dielectric permittivity of PE is approximately 2.3. The outer two aluminum bars were connected to the LO input ofthe electrometer and the central aluminum bar was connected to the HI input of a Keithley model 617 electrometer. Once the stack is mechanically well-seated with no air gaps, the voltage offset is observed tobe a linear function of the baseline voltage for a given change in applied force. For a periodically appliedforce of 66.7 kN the voltage offsets were measured as a function of initial voltage, and these data were fitwith a linear function that was constrained to pass through the origin. The best fit solution had a correlation coefficient of R=0.85 and a slope of approximately -0.0228 volts/volt. The voltage offset when normalizedis demonstrated to be constant -2.28% for both positive and negative polarities over nearly 3 orders ofbaseline voltage magnitude. From this, the voltage-force coefficient is derived to be -0.34 ppm/N. Thiscorrelates well to a first-order parallel plate capacitor model that assumes constant area, and smalldeformation such that the polymer may be mechanically modeled by a spring that obeys Hookes law. Thissimple model predicts that the coefficient of proportionality is a function of Youngs modulus E= 0.8 GPaand surface area of the insulator, theoretically -1EA= -0.31 ppm/N. The outcome of this work is animproved insulator made from ultra-high molecular weight (UHMW) polyethylene and other approachestoward the minimization of and compensation for these experimental artifacts.

Electromagnetic Studies of Rocks↗

FPGA Mitigation Strategies for Critical Applications

Technology is changing at a fast pace. Transistor geometries are getting smaller, voltage thresholds are getting lower, design complexity is exponentially increasing, and user options are expanding. Consequently, reliable insertion of error detection and correction (EDAC) circuitry has become relatively challenging. As a response, a variety of mitigation techniques are being evaluated. They range from weak EDAC circuits that save area and power to strong mitigation strategies that are a great expense to systems. This presentation will focus on radiation induced susceptibilities for a variety of FPGA types and ASIC devices. In addition, the user will be provided information on applicable mitigation strategies per device.

Berg, Melanie↗

Thrust Stand Measurements of a Conical Inductive Pulsed Plasma Thruster

Inductive Pulsed Plasma Thrusters (iPPT) spacecraft propulsion devices in which electrical energy is capacitively stored and then discharged through an inductive coil. The thruster is electrodeless, with a time-varying current in the coil interacting with a plasma covering the face of the coil to induce a plasma current Propellant is accelerated and expelled at a high exhaust velocity (O(10 -- 100 km/s)) by the Lorentz body force arising from the interaction of the magnetic field and the induced plasma current. While this class of thruster mitigates the life-limiting issues associated with electrode erosion, inductive pulsed plasma thrusters can suffer from both high pulse energy requirements imposed by the voltage demands of inductive propellant ionization, and low propellant utilization efficiencies. While this class of thruster mitigates the life-limiting issues associated with electrode erosion, inductive pulsed plasma thrusters can suffer from both high pulse energy requirements imposed by the voltage demands of inductive propellant ionization, and low propellant utilization efficiencies. A conical coil geometry may offer higher propellant utilization efficiency over that of a at inductive coil, however an increase in propellant utilization may be met with a decrease in axial electromagnetic acceleration, and in turn, a decrease in the total axially-directed kinetic energy imparted to the propellant.

Hallock, Ashley K.↗

Suborbital Lunar Gravity Experiment of an Electrodynamic Regolith Conveyor

NASA’s Swamp Works Electrostatics and Surface Physics Laboratory (ESPL) is planning to test a 4-phase electrodynamic regolith conveyor in simulated lunar gravity on a suborbital flight in 2023. A 4-phase electrodynamic regolith conveyor could convey regolith without the risk of rotating or vibratory actuation, which could jam or require regular maintenance due to the abrasive nature of lunar regolith. Another advantage of electrodynamic conveying is the reduction of conveying power, which is important considering the limited scale of available early-stage lunar power systems. The current state of the art(SOA) for lunar regolith conveying is based on recent NASA system studies for oxygen production plants. These plant designs require conveying rates around 100 kg/hr, to produce 10 mT/yr of oxygen from the regolith. To accomplish this, conventional augers and vibratory spiral conveyors have been identified as the SOA or the leading candidates due to their extensive use in the terrestrial material handling industry. At NASA KSC, the use of dynamic electric fields, generated by alternating high voltage on electrodes, has been developed as a dust mitigation solution known as the Electrodynamic Dust Shield (EDS). The EDS is being developed for lenses, solar panels, radiators, fabric and seals. ESPL researchers have shown the ability to move thin layers (~ a few mm) of dust with mW of power. In Academia, researchers have shown the ability to electrodynamically convey regolith up to ~1 kg/hr with a4-phase EDS and electromagnetically convey particles that would suggest a lunar regolith conveying rate of ~25 kg/hr. This paper will describe the design and expected operation of a 4-phase electrodynamic regolith conveyor in lunar gravity. This paper will also describe how an electrodynamic conveyor could be scaled for transporting ISRU relevant flow rates.

Aaron D S Olson↗

Design and Testing of a Prototype Electrodynamic Regolith Conveyor for Lunar ISRU

NASA’s Swamp Works Electrostatics and Surface Physics Laboratory (ESPL) is developing a 4-phaseelectrodynamic regolith conveyor (ERC) that could convey regolith without the risk of rotating or vibratory actuation, which could jam or require regular maintenance due to the abrasive nature of lunar regolith. Another goal of electrodynamic conveying is the reduction of conveying power, which is important considering the limited capacity of early-stage lunar power systems. The current state of the art(SOA) for lunar regolith conveying is based on recent NASA system studies for oxygen production plants. These plant designs require conveying rates around 100 kg/hr, to produce 10 mT/yr of oxygen from the regolith. To accomplish this, conventional augers and vibratory spiral conveyors have been identified as the SOA or the leading candidates due to their extensive use in the terrestrial material handling industry. At NASA KSC, the use of dynamic electric fields, generated by alternating high voltage on electrodes, has been developed as a dust mitigation solution known as the Electrodynamic Dust Shield (EDS). The EDS is being developed for lenses, solar panels, radiators, fabric and seals and is scheduled for a technology demonstration mission on the Moon in 2023. ESPL researchers have shown the ability to move thin layers (~ a few mm) of dust with mW of power. In Academia, researchers have shown the ability to electrodynamically convey regolith up to ~1 kg/hr with a 4-phase EDS and electromagnetically convey particles that would suggest a lunar regolith conveying rate of ~25 kg/hr. This paper will describe the design and testing of a prototype ERC that could scale to support transporting regolith at ISRU relevant flow rates.

Aaron D S Olson↗

Design and Testing of a Prototype Electrodynamic Regolith Conveyor For Lunar ISRU

NASA’s Kennedy Space Center’s (KSC) Swamp Works Electrostatics and Surface Physics Laboratory (ESPL) is developing a 4-phase Electrodynamic Regolith Conveyor (ERC) that could convey regolith without the risk of rotating or vibratory actuation, which could jam or require regular maintenance due to the abrasive nature of lunar regolith. Another goal of electrodynamic conveying is the reduction of conveying power, which is important considering the limited capacity of early-stage lunar power systems. The current state of the art (SOA) for lunar regolith conveying is based on recent NASA system studies for oxygen production plants. These plant designs require conveying rates around 100 kg/hr, to produce 10 mT/yr of oxygen from the regolith. To accomplish this, conventional augers and vibratory spiral conveyors have been identified as the SOA or the leading candidates due to their extensive use in the terrestrial material handling industry. At NASA KSC, the use of dynamic electric fields, generated by alternating high voltage on electrodes, has been developed as a dust mitigation solution known as the Electrodynamic Dust Shield (EDS). The EDS is being developed for lenses, solar panels, radiators, fabric and seals and is scheduled for a technology demonstration mission on the Moon in 2023. ESPL researchers have shown the ability to move thin layers (a few mm) of dust with mW of power. In Academia, researchers have shown the ability to electrodynamically convey regolith up to 1 kg/hr with a 4-phase EDS. This paper will describe the design and testing of a prototype ERC that could scale to support transporting regolith at ISRU relevant flow rates.

Conveyor↗

Design and Testing of a Prototype Electrodynamic Regolith Conveyor for Lunar ISRU

NASA’s Kennedy Space Center’s (KSC) Swamp Works Electrostatics and Surface Physics Laboratory (ESPL) is developing a 4-phase Electrodynamic Regolith Conveyor (ERC) that could convey regolith without the risk of rotating or vibratory actuation, which could jam or require regular maintenance due to the abrasive nature of lunar regolith. Another goal of electrodynamic conveying is the reduction of conveying power, which is important considering the limited capacity of early-stage lunar power systems. The current state of the art (SOA) for lunar regolith conveying is based on recent NASA system studies for oxygen production plants. These plant designs require conveying rates around 100 kg/hr, to produce 10 mT/yr of oxygen from the regolith. To accomplish this, conventional augers and vibratory spiral conveyors have been identified as the SOA or the leading candidates due to their extensive use in the terrestrial material handling industry. At NASA KSC, the use of dynamic electric fields, generated by alternating high voltage on electrodes, has been developed as a dust mitigation solution known as the Electrodynamic Dust Shield (EDS). The EDS is being developed for lenses, solar panels, radiators, fabric and seals and is scheduled for a technology demonstration mission on the Moon in 2023. ESPL researchers have shown the ability to move thin layers (a few mm) of dust with mW of power. In Academia, researchers have shown the ability to electrodynamically convey regolith up to 1 kg/hr with a 4-phase EDS. This paper will describe the design and testing of a prototype ERC that could scale to support transporting regolith at ISRU relevant flow rates.

Lunar↗

Controlling Electron Backstreaming Phenomena Through the Use of a Transverse Magnetic Field

DEEP-SPACE mission propulsion requirements can be satisfied by the use of high specific impulse systems such as ion thrusters. For such missions. however. the ion thruster will be required to provide thrust for long periods of time. To meet the long operation time and high-propellant throughput requirements, thruster lifetime must be increased. In general, potential ion thruster failure mechanisms associated with long-duration thrusting can be grouped into four areas: (1) ion optics failure; (2) discharge cathode failure; (3) neutralizer failure; and (4) electron backstreaming caused by accelerator grid aperture enlargement brought on by accelerator grid erosion. The work presented here focuses on electron backstreaming. which occurs when the potential at the center of an accelerator grid aperture is insufficient to prevent the backflow of electrons into the ion thruster. The likelihood of this occurring depends on ion source operation time. plasma density, and grid voltages, as accelerator grid apertures enlarge as a result of erosion. Electrons that enter the gap between the high-voltage screen and accelerator grids are accelerated to the energies approximately equal to the beam voltage. This energetic electron beam (typically higher than 1 kV) can damage not only the ion source discharge cathode assembly. but also any of the discharge surfaces upstream of the ion acceleration optics that the electrons happen to impact. Indeed. past backstreaming studies have shown that near the backstreaming limit, which corresponds to the absolute value of the accelerator grid voltage below which electrons can backflow into the thruster, there is a rather sharp rise in temperature at structures such as the cathode keeper electrode. In this respect operation at accelerator grid voltages near the backstreaming limit is avoided. Generally speaking, electron backstreaming is prevented by operating the accelerator grid at a sufficiently negative voltage to ensure a sufficiently negative aperture center potential. This approach can provide the necessary margin assuming an expected aperture enlargement. Operation at very negative accelerator grid voltages, however, enhances ion charge-exchange and direct impingement erosion of the accelerator grid. The focus of the work presented here is the mitigation of electron backstreaming by the use of a magnetic field. The presence of a magnetic field oriented perpendicular to the thruster axis can significantly decrease the magnitude of the backflowing electron current by significantly reducing the electron diffusion coefficient. Negative ion sources utilize this principle to reduce the fraction of electrons in the negative ion beam. The focus of these efforts has been on the attenuation of electron current diffusing from the discharge plasma into the negative ion extraction optics by placing the transverse magnetic field upstream of the extraction electrodes. In contrast. in the case of positive ion sources such as ion thrusters, the approach taken in the work presented here is to apply the transverse field downstream of the ion extraction system so as to prevent electrons from flowing back into the source. It was found in the work presented here that the magnetic field also reduces the absolute value of the electron backstreaming limit voltage. In this respect. the applied transverse magnetic field provides two mechanisms for electron backstreaming mitigation: (1) electron current attenuation and (2) backstreaming limit voltage shift. Such a shift to less negative voltages can lead to reduced accelerator grid erosion rates.

Foster, John E.↗

Influence of Tailored Applied Magnetic Fields on High-Power MPD Thruster Current Transport and Onset-Related Phenomena

This work investigated the effects of tailored, externally-applied magnetic fields on current transport and near-anode processes in the plasma discharge of a magnetoplasmadynamic thruster (MPDT). Electrical and plasma diagnostics were used to investigate how localized applied magnetic fields could mitigate the effects of the "onset" phenomena, including large-amplitude terminal voltage fluctuations and high anode fall voltages associated with unstable operation and anode erosion. An MPDT with a multi-channel hollow cathode was developed and tested with quasi-steady pulses of 1 millisecond duration at power levels of 36 kilowatts (20 volts, 1800 amperes) to 3.3 milliwatts (255 volts, 13.1 kiloamperes) with argon propellant in three different magnetic configurations: self-field, applied B field tangential to the anode lip near the exit plane, and applied cusp B field. The current pattern and current densities redistributed to follow the applied poloidal magnetic field lines, which created increased conduction paths to the anode. Also, the anode fall voltage was substantially reduced with both applied B field topologies over a large range of currents. For example, at 10.7 kiloamperes, the cusp applied magnetic field decreased anode fall voltages from 45-83 volts down to 15 volts or lower along much of the anode. The amplitude and frequency of the voltage fluctuations were also reduced over a broad range of currents with the applied fields. E.g., the standard deviations of the fluctuations were lowered by 37-49 percent at 8-9 kiloamperes. In addition, decreases in the mean terminal voltages as large as 31 percent were measured with the applied magnetic fields. These effects are shown to be associated with the increased current conduction along the applied magnetic field lines in the near-anode region. These results also suggest a reduction in frequency and intensity of current-concentrating filaments and anode spots, which contribute to erosion. Overall, both applied magnetic field configurations enabled significant reductions in onset-related behaviors relative to self-field operation. These improvements should lead to reduced anode erosion, i.e., improved thruster lifetime, and increased thruster efficiency with the applied fields. The applied fields used in this study differ from both the topologies and relative field strengths typically used in the vast majority of conventional, so-called "applied-field MPD thrusters" (AF-MPDTs). These results suggest a distinctive and more effective approach to influencing the near-anode phenomena and mitigating the deleterious effects of onset with appropriately designed applied magnetic fields.

delta-V↗

Anomalous Transients in Chip Polymer Tantalum Capacitors

Contrary to MnO2 tantalum capacitors, transient processes in polymer tantalum capacitors after voltage application might result in anomalously high, ampere-level currents when a capacitor might appear as a short circuit for a time that is much greater than a transient time in MnO2 capacitors. In this work, conditions that cause anomalous transients in different types of polymer tantalum capacitors have been analyzed. Related phenomena that included increasing of capacitance and dissipation factors with voltage, parametric surge current test failures without damage to capacitors, and increasing leakage currents at low temperatures are described. It has been shown that anomalous transients increased substantially with applied voltage and with reduction of moisture content in capacitors caused by storage or operation at high temperatures and/or in vacuum. Different types of capacitors exhibited different level of transients and modification of conductive polymers or process of their application might decrease transient leakage currents substantially. For space applications, the risk of failures related to anomalous transients can be mitigated by special testing procedures to select parts with an acceptable level of transients and by voltage derating.

Tantalum Capacitors↗