Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage sensing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Short Circuit Detection and Voltage Sense for High Voltage Ionization Tube Power Supplies

Fermilab's PIP-II upgrade requires new rack-mounted power supplies for Beam Loss Monitor (BLM) ionization tubes compatible with the microTCA 4.1 standard, supporting high-side current measurement for short circuit detection, voltage sense telemetry, and low-side current measurement for beam loss readout. This work presents the design and preliminary schematic of such a supply. A resistive current sensing approach was chosen over inductive, optical, and Hall-effect alternatives for its independence from cable length and component availability. A 500 mΩ inline shunt steps the 2 kV common mode voltage down to roughly 70 V, producing a ~27 μV pulse during a short, which is amplified 500x, compared against a 14-bit DAC threshold, and latched to drive a fault line. Voltage sense steps the 2 kV output down at a 1V/1000V ratio, buffers it with a low bias current amplifier, and digitizes it via a 24-bit ADC over SPI. Onboard power is regulated from 12 V down to isolated 5 V and 3.3 V rails, with capacitive isolation on FPGA communication lines. Lumped parameter models were developed for the ionization tube (0.327 nF, 20 to 200 GΩ dynamic resistance) and the RG-58 coaxial cable to support the design. Component selection is complete and a preliminary schematic has been drawn in Altium Designer, forming the foundation for future prototyping and validation.

Yu, Kellen [Cornell U.]↗

Coupling sensor to enzyme in the voltage sensing phosphatase

Voltage-sensing phosphatases (VSPs) dephosphorylate phosphoinositide (PIP) signaling lipids in response to membrane depolarization. VSPs possess an S4-containing voltage sensor domain (VSD), resembling that of voltage-gated cation channels, and a lipid phosphatase domain (PD). The mechanism by which voltage turns on enzyme activity is unclear. Structural analysis and modeling suggest several sites of VSD-PD interaction that could couple voltage sensing to catalysis. Voltage clamp fluorometry reveals voltage-driven rearrangements in three sites implicated earlier in enzyme activation—the VSD-PD linker, gating loop and R loop—as well as the N-terminal domain, which has not yet been explored. N-terminus mutations perturb both rearrangements in the other segments and enzyme activity. Our results provide a model for a dynamic assembly by which S4 controls the catalytic site.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Membrane potential sensing: Material design and method development for single particle optical electrophysiology

We review the development of “single” nanoparticle-based inorganic and organic voltage sensors, which can eventually become a viable tool for “non-genetic optogenetics.” The voltage sensing is accomplished with optical imaging at the fast temporal response and high spatial resolutions in a large field of view. Inorganic voltage nanosensors utilize the Quantum Confined Stark Effect (QCSE) to sense local electric fields. Engineered nanoparticles achieve substantial single-particle voltage sensitivity (~2% Δλ spectral Stark shift up to ~30% ΔF/F per 160 mV) at room temperature due to enhanced charge separation. A dedicated home-built fluorescence microscope records spectrally resolved images to measure the QCSE induced spectral shift at the single-particle level. Biomaterial based surface ligands are designed and developed based on theoretical simulations. The hybrid nanobiomaterials satisfy anisotropic facet-selective coating, enabling effective compartmentalization beyond non-specific staining. Self-spiking- and patched-HEK293 cells and cortical neurons, when stained with hybrid nanobiomaterials, show clear photoluminescence intensity changes in response to membrane potential (MP) changes. Organic voltage nanosensors based on polystyrene beads and nanodisk technology utilize Fluorescence (Förster) Resonance Energy Transfer (FRET) to sense local electric fields. Voltage sensing FRET pairs achieve voltage sensitivity up to ~35% ΔF/F per 120 mV in cultures. Non-invasive MP recording from individual targeted sites (synapses and spines) with nanodisks has been realized. However, both of these QCSE- and FRET-based voltage nanosensors yet need to reach the milestone of recording individual action potentials from individual targeted sites.

59 BASIC BIOLOGICAL SCIENCES↗

Structure of the Human BK Ion Channel in Lipid Environment

Voltage-gated and ligand-modulated ion channels play critical roles in excitable cells. To understand the interplay among voltage sensing, ligand binding, and channel opening, the structures of ion channels in various functional states and in lipid membrane environments need to be determined. Here, the random spherically constrained (RSC) single-particle cryo-EM method was employed to study human large conductance voltage- and calcium-activated potassium (hBK or hSlo1) channels reconstituted into liposomes. The hBK structure was determined at 3.5 Å resolution in the absence of Ca 2+ . Instead of the common fourfold symmetry observed in ligand-modulated ion channels, a twofold symmetry was observed in hBK in liposomes. Compared with the structure of isolated hSlo1 Ca 2+ sensing gating rings, two opposing subunits in hBK unfurled, resulting in a wider opening towards the transmembrane region of hBK. In the pore gate domain, two opposing subunits also moved downwards relative to the two other subunits.

59 BASIC BIOLOGICAL SCIENCES↗

Understanding Reliability Trade-Offs in 1T-nC and 2T-nC FeRAM Designs

Ferroelectric random access memory (FeRAM) is a promising candidate for energy-efficient nonvolatile memory, particularly for logic-in-memory and compute-in-memory (CIM) applications. Among the available cell architectures, One-Transistor–n-Capacitor (1T-nC) and two-transistor–n-capacitor (2T-nC) FeRAMs each offer distinct trade-offs in density, scalability, and reliability. In this work, we present a comparative study of these two architectures under both dimensional scaling ( XY/Z shrinkage) and vertical integration (increasing stacked capacitors per cell). Using technology computer-aided design (TCAD) and circuit-level simulations, we analyze how scaling impacts ferroelectric capacitance, parasitic coupling, and floating-node (FN) dynamics, which together dictate sense margin (SM) and read stability. A key mitigation strategy—floating unselected capacitors—is applied to both architectures, effectively decoupling the SM from the number of stacked capacitors and enabling tractable analysis across scaling regimes. Results show that 1T-nC suffers more from charge sharing with the bitline (BL), while 2T-nC benefits from transistor isolation and stronger low-voltage sensing at the cost of increased area. By systematically evaluating these behaviors across scaling directions, this work establishes the reliability trade-offs of 1T-nC and 2T-nC cells and provides design guidelines for high-density, vertically integrated FeRAM systems.

1T-nC↗

Water, Protons, and the Gating of Voltage-Gated Potassium Channels

Ion channels are ubiquitous throughout all forms of life. Potassium channels are even found in viruses. Every cell must communicate with its surroundings, so all cells have them, and excitable cells, in particular, especially nerve cells, depend on the behavior of these channels. Every channel must be open at the appropriate time, and only then, so that each channel opens in response to the stimulus that tells that channel to open. One set of channels, including those in nerve cells, responds to voltage. There is a standard model for the gating of these channels that has a section of the protein moving in response to the voltage. However, there is evidence that protons are moving, rather than protein. Water is critical as part of the gating process, although it is hard to see how this works in the standard model. Here, we review the extensive evidence of the importance of the role of water and protons in gating these channels. Our principal example, but by no means the only example, will be the Kv1.2 channel. Evidence comes from the effects of D2O, from mutations in the voltage sensing domain, as well as in the linker between that domain and the gate, and at the gate itself. There is additional evidence from computations, especially quantum calculations. Structural evidence comes from X-ray studies. The hydration of ions is critical in the transfer of ions in constricted spaces, such as the gate region and the pore of a channel; we will see how the structure of the hydrated ion fits with the structure of the channel. In addition, there is macroscopic evidence from osmotic experiments and streaming current measurements. The combined evidence is discussed in the context of a model that emphasizes the role of protons and water in gating these channels.

59 BASIC BIOLOGICAL SCIENCES↗

Point-localized, site-specific membrane potential optical recording by single fluorescent nanodiscs

Nanodisc technology was implemented as a platform for voltage nanosensors. A fluorescence (Förster) resonance energy transfer (FRET)-based voltage-sensing scheme employing fluorescent nanodiscs and the hydrophobic ion dipicrylamine was developed and utilized to optically record membrane potentials on the single-nanodisc level. Ensemble and single-nanosensor recordings were demonstrated for HEK293 cells and primary cortical neuron cells. Conjugation of nanodiscs to anti-GABA A antibodies allowed for site-specific membrane potential measurements from postsynaptic sites.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Smart dim fuse: electrical load flexibility controller using sub-circuit voltage modulation and load sensing

Improved control of electrical power consumption is provided with “Smart Dim Fuses” (SDF) which can alter their output voltage as provided to the load circuits they are connected to. SDF units can replace conventional circuit breakers in electrical panels. The voltage control capability provided by SDF units can lead to improved control of electrical power consumption, since many loads can smoothly operate at lower power consumption when the voltage they are driven with decreases. SDF units can comply with relevant safety requirements, such as uninterrupted neutral connections between electrical mains and load circuits. SDF units can also provide a current limiting function that can substitute for the protective action of conventional circuit breakers.

Goldin, Aaron↗

Self-Sensing, Stretchable, Active Circuit Arrays: Liquid Metal Paste as a Combination Interconnect and Strain Sensor

Stretchable electrical interconnects and substrate materials are increasingly used to create flexible and con-formable electronic systems for soft robotics, smart textiles, and wearable devices. Wires fabricated using composite or liquid conductive inks encapsulated in silicone enable high strain and are mechanically robust. The resistance of these inter-connects increases with strain, which can present challenges for power delivery and signaling among electronic components. However, this effect can be used directly to estimate strain within a stretchable circuit without the need for additional sensor components. In this work, we present an approach for fabricating fully-stretchable, multi-layer active circuit arrays in silicone using liquid metal paste interconnects, in which power and data wires are re-purposed as strain sensors to estimate substrate deformation. As a proof-of-principle, we demonstrate a 3×3 active circuit array that self-senses relative voltage supply at each node to estimate deformation and consumes less than 10 mA per node. Each node is digitally addressable and performs both analog measurement and digital conversion. All interconnects are fabricated using liquid metal paste, and power, data, and sensing are performed over a shared, four-wire interface in this multi-layer stretchable printed circuit board.

99 GENERAL AND MISCELLANEOUS↗

Graphene Electric Field Sensor Enables Single Shot Label-Free Imaging of Bioelectric Potentials

The measurement of electrical activity across systems of excitable cells underlies current progress in neuroscience, cardiac pharmacology, and neurotechnology. However, bioelectricity spans orders of magnitude in intensity, space, and time, posing substantial technological challenges. The development of methods permitting network-scale recordings with high spatial resolution remains key to studies of electrogenic cells, emergent networks, and bioelectric computation. Here, for this work, we demonstrate single-shot and label-free imaging of extracellular potentials with high resolution across a wide field-of-view. The critically coupled waveguide-amplified graphene electric field (CAGE) sensor leverages the field-sensitive optical transitions in graphene to convert electric potentials into the optical regime. As a proof-of-concept, we use the CAGE sensor to detect native electrical activity from cardiac action potentials with tens-of-microns resolution, simultaneously map the propagation of these potentials at tissue-scale, and monitor their modification by pharmacological agents. This platform is robust, scalable, and compatible with existing microscopy techniques for multimodal correlative imaging.

47 OTHER INSTRUMENTATION↗

Aureochromes maintain polyunsaturated fatty acid content in Nannochloropsis oceanica

Abstract Nannochloropsis oceanica, like other stramenopile microalgae, is rich in long-chain polyunsaturated fatty acids (LC-PUFAs) such as eicosapentaenoic acid (EPA). We observed that fatty acid desaturases (FADs) involved in LC-PUFA biosynthesis were among the strongest blue light-induced genes in N. oceanica CCMP1779. Blue light was also necessary for maintaining LC-PUFA levels in CCMP1779 cells, and growth under red light led to a reduction in EPA content. Aureochromes are stramenopile-specific proteins that contain a light–oxygen–voltage (LOV)-sensing domain that associates with a flavin mononucleotide and is able to sense blue light. These proteins also contain a basic leucine zipper DNA-binding motif and can act as blue light-regulated transcription factors by associating with an E-box like motif, which we found enriched in the promoters of blue light-induced genes. We demonstrated that, in vitro, two CCMP1779 aureochromes were able to absorb blue light. Moreover, the loss or reduction of the expression of any of the three aureochrome genes led to a decrease in the blue light-specific induction of several FADs in CCMP1779. EPA content was also significantly reduced in NoAUREO2 and NoAUREO4 mutants. Taken together, our results indicate that aureochromes mediate blue light-dependent regulation of LC-PUFA content in N. oceanica CCMP1779 cells.

Plant Sciences↗

DER Inverter Control Fault Ride Through Model in Accordance with IEEE 1547-2018 Std

Distributed Energy Resources (DER) with smart inverters are becoming more prevalent as the need for renewable energy and grid stability increases. An important challenge arises when considering that inverterbased generation methods contribute less current during faults, rendering traditional overcurrent protection unsatisfactory. DERs have fault ride-through requirements when operating in high or low voltage, outlined by IEEE Std. 1547-2018. Faults cause the voltage to reach abnormal steady state magnitudes, depending on the fault resistance and fault type. There are several high voltage and low voltage ride-through zones defined by IEEE Std. 1547-2018. Each zone’s ride through duration decreases as the applicable voltage measurement, i.e., the phase RMS voltage, deviates from its nominal value. This presentation demonstrates the implementation of IEEE Std. 1547-2018 high and low voltage ridethrough grid support functions using a preexisting RSCAD model, discussing the challenges presented during this process. The implemented controls monitor the filtered phase voltages to have a more accurate reading of the applicable voltages. The controls sense the duration that the applicable voltage remains in a specific zone. The breaker trips and ceases energization to the grid when the duration is exceeded. The standard allows the operator to adjust the ride-through times and voltage zones from the default settings. These ranges are implemented into the runtime, which acts as the operator’s SCADA. The results show the accuracy of the voltage measurements, which remain within the IEEE Std. 1547-2018 for all cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart controller with phantom inductor current sensing for switched mode power supplies

Voltage on the output terminal of an inductor is obtained as a first input signal to a control block (CB); the inductor has an input terminal connected to a power switch and driver block at a switching node. A sense input voltage is obtained on an output terminal of a sensing circuit that is not directly connected to the switching node, as a second input signal to the CB. A voltage is generated on a first output terminal of the CB and is selected such that the CB can use its first and second input signals to infer the current through the inductor. A pulse width modulation (PWM) signal is generated on a second output terminal of the CB, based on the inferred current through the inductor; the second output signal from the CB is provided to a PWM input terminal of the power switch and driver block.

Zhang, Xin↗

Evaluation of Neutron-Radiation Tolerance of Lithium Indium Diselenide Semiconductors

Herein we discuss lithium indium diselenide (LISe) as a semiconductor that holds promise for neutron imaging sensor technologies because of its high neutron absorption efficiency and its corresponding ability to discriminate between gamma rays and neutrons. However, being a semiconductor, LISe may not be sufficiently radiation hard for practical application in radiation hard environments. Therefore, a systematic evaluation of the changes in material and electronic properties of LISe after high neutron fluence exposures is investigated. Herein, the characterization methods are utilized which included UV–vis, X-ray diffraction, radioluminescence, Raman, fourier transform infrared spectroscopy (FTIR), current–voltage, and neutron sensing. Characteristics of LISe material that appeared in the literature are identified herein along with several that are expected to appear based on theoretical analyses. The results obtained show clear changes in the material properties of LISe after neutron exposure up to a fluence of 10 16 n cm -2 . However, LISe is still able to sense neutrons above the background at 10 16 n cm -2 , suggesting that LISe may be suitable for use in neutron imaging sensors at neutron imaging facilities.

36 MATERIALS SCIENCE↗

Rolling Root Mean Square Based Multimodal Anomaly Detection for Real Time Monitoring of Smart Grid

Reliable real-time monitoring is valuable for maintaining the operational integrity of modern electrical smart grids. Deployment of heterogeneous sensing technologies in substations has enabled high-resolution, multichannel waveform monitoring, but also introduces challenges for anomaly detection due to noise, baseline drift, and modality-dependent signal characteristics. In this work, we present a computationally efficient unsupervised method for multimodal event detection based on Rolling Root Mean Square based Event Detection (RRMSED). The method is developed using in-house, field deployed sensors collecting data at a utility substation. The sensing system comprises voltage and current sensors, triaxial accelerometers, and magnetometers, collectively capturing electrical, vibrational, and magnetic waveform measurements at high temporal resolution. RRMSED operates by extracting rolling RMS energy features and their first-order temporal differences from consecutive waveform segments for each channel and then applying channel-specific statistical thresholds learned from historical data. A persistence-based exceedance logic is employed to robustly identify transient events while suppressing impulsive noise, and to provide precise temporal localization with high resolution. The framework is designed for continuous server-side operation and can be deployed in real time without requiring complex models. Experiments on simulated waveform data with known ground truth demonstrate low false positive (FP) and false negative (FN) rates. Application to real substation data shows RRMSED to identify events that are not captured by conventional monitoring indicators including fast transient detection algorithm currently deployed in the system. These results indicate that rolling RMS based features provide an effective and practical basis for real-time multimodal event detection in smart-grid substations.

Mukherjee, Subrata [ORNL] (ORCID:0000000309930338)↗

Dimming LED circuit augmenting DC/DC controller integrated circuit

Embodiments include systems, methods, and apparatuses for providing a dimming function in a single stage AC input light emitting diode (LED) driver with a controller that contains an on-chip error amplifier and an on-chip fixed reference voltage source coupled to a first input of the error amplifier. The controller controls a duty cycle of a switching transistor to cause a feedback voltage, applied to a first package input terminal, to match the reference voltage. To achieve a dimming function, a voltage across a current sense resistor in series with the LEDs is applied to a first input of a high gain differential amplifier, and a variable dimming control voltage is applied to a second input of the differential amplifier. The output of the differential amplifier is coupled to the first package input terminal. The differential amplifier input signals will be matched at the target LED current level.

Song, Zhengrong↗

Voltage Estimation in Low-Voltage Distribution Grids with Distributed Energy Resources

Present distribution grids generally have limited sensing capabilities and are therefore characterized by low observability. Improved observability is a prerequisite for increasing the hosting capacity of distributed energy resources such as solar photovoltaics (PV) in distribution grids. In this context, this paper presents learning-aided low-voltage estimation using untapped but readily available and widely distributed sensors from cable television (CATV) networks. The cable broadband sensors offer timely local voltage magnitude sensing with 5-minute resolution and can provide an order of magnitude more data on the time-varying state of a secondary distribution system than currently deployed utility sensors. The proposed solution incorporates voltage readings from neighboring CATV sensors, taking into account spatio-temporal aspects of the observations, and estimates single-phase voltage magnitudes at all non-monitored low-voltage buses using random forests. The effectiveness of the proposed approach was demonstrated using a multi-phase 1572-bus feeder from the SMART-DS data set for two case studies passive distribution feeder (without PV) and active distribution feeder (with PV). The analysis was conducted on simulated data, and the results show voltage estimates with a high degree of accuracy, even at extremely low percentages of observable nodes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-time Condition Monitoring of Power Modules in Grid-tied Power Converter

This paper proposes and demonstrates a real-time condition monitoring method using gate driver integrated sensing circuits and sensor fusion algorithms. Power device on-state voltage (VDSon) measurement and junction temperature (Tj) sensing circuits with high noise immunity are built and integrated into an adaptive gate driver circuit for power modules. Considering the inherently noisy measurement environment of power converters, VDSon together with several other measurements are fused together to provide accurate descriptions of the stress and degradation of each power device. Furthermore, the gate driver circuit can actively control the turn-on gate voltage (VGSon) for each device based on the stress and degradation state. The proposed sensing circuits and power device condition assessment algorithms are implemented in a 75 KVA grid-tied power converter. This paper focuses on the sensing circuits hardware designs and testing in grid-tied power converter prototype and device stress index generation. More comprehensive results on the device state of health index generation will be presented in future work.

Fan, Junchong↗