Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Probabilistic Voltage Sensitivity based Preemptive Voltage Monitoring in Unbalanced Distribution Networks

With increasing penetration of renewable energy and active consumers, control and management of power distribution networks has become challenging. Renewable energy sources can cause random voltage fluctuations as their output power depends on weather conditions. Conventional voltage control schemes such as tap changers and capacitor banks lack the foresight required to quickly alleviate voltage violations. Thus, there is an urgent need for effective approaches for predicting and mitigating voltage violations as a result of random fluctuations in power injections. This work proposes a novel voltage monitoring approach based on low-complexity, data-driven probabilistic voltage sensitivity analysis. The usefulness of this work is not only in predicting voltage violations in unbalanced distribution grids, but also in opening up the door for optimal voltage control. Using system data and forecasts, the proposed approach predicts the distribution of system node voltages which is then used to to identify nodes that may violate the nominal operational limits with high probability. The method is tested on the IEEE 37 node distribution system considering integrated distributed solar energy sources. The method is validated against the classic load flow based method and offers over 95% accuracy in predicting voltage violations.

Abujubbeh, Mohammad↗

The Single Residue K12 Governs the Exceptional Voltage Sensitivity of Mitochondrial Voltage-Dependent Anion Channel Gating

The voltage-dependent anion channel (VDAC) is a β-barrel channel of the mitochondrial outer membrane (MOM) that passively transports ions, metabolites, polypeptides, and single-stranded DNA. VDAC responds to a transmembrane potential by “gating,” i.e. transitioning to one of a variety of low-conducting states of unknown structure. The gated state results in nearly complete suppression of multivalent mitochondrial metabolite (such as ATP and ADP) transport, while enhancing calcium transport. Voltage gating is a universal property of β-barrel channels, but VDAC gating is anomalously sensitive to transmembrane potential. Here, we show that a single residue in the pore interior, K12, is responsible for most of VDAC’s voltage sensitivity. Using the analysis of over 40 μs of atomistic molecular dynamics (MD) simulations, we explore correlations between motions of charged residues inside the VDAC pore and geometric deformations of the β-barrel. Residue K12 is bistable; its motions between two widely separated positions along the pore axis enhance the fluctuations of the β-barrel and augment the likelihood of gating. Single channel electrophysiology of various K12 mutants reveals a dramatic reduction of the voltage-induced gating transitions. The crystal structure of the K12E mutant at a resolution of 2.6 Å indicates a similar architecture of the K12E mutant to the wild type; however, 60 μs of atomistic MD simulations using the K12E mutant show restricted motion of residue 12, due to enhanced connectivity with neighboring residues, and diminished amplitude of barrel motions. We conclude that β-barrel fluctuations, governed particularly by residue K12, drive VDAC gating transitions.

59 BASIC BIOLOGICAL SCIENCES↗

Analytical Voltage Sensitivity Analysis for Unbalanced Power Distribution System

Large scale integration of distributed energy resources and electric vehicles in a transactive energy environment present new challenges in terms of voltage stability and fluctuations in a power distribution system. The impact of different level of DER/EV penetration on the voltages across the network is typically quantified through voltage sensitivity analyses. Existing methods of voltage sensitivity analysis are computationally expensive and prior efforts to develop analytical approximation lacks generality and have not been effectively validated. The objective of this work is to provide a new analytical method of voltage sensitivity analysis that has low computational cost and also allows for stochastic analysis of voltage change. This paper first derives an analytical approximation of change in voltage at a particular bus due to change in power consumption at other bus in a radial three phase unbalanced power distribution system. Then, the proposed method is shown to be valid for different load configurations, which demonstrates its generality. The results from our analytical approach is validated via classical load flow simulation of the test system based on IEEE 37 bus network. The proposed method is shown to have good accuracy, and computation complexity is of order O(1), compared to O(n3) in classical sensitivity analysis approaches.

Munikoti, Sai↗

Data-Driven Preemptive Voltage Monitoring and Control Using Probabilistic Voltage Sensitivities

Increased penetration levels of distributed variable renewable generation can cause random voltage fluctuations and violations at multiple nodes. Traditional methods of voltage control typically involve reactionary responses of capacitor banks, tap changers, and recently even smart inverters. But because of the lack of foresight in voltage violations, these controls are ineffective to completely mitigate the issue. Therefore, new methods of predicting voltage violations subject to random power injection changes in the distribution network are needed, which can be used to guide optimal and dynamic methods of voltage control. This work lays the foundation for such preemptive voltage monitoring and control by proposing an analytical and sensor data-driven voltage sensitivity analysis method. Driven by stochastic data and forecasts, the method can be used to develop probabilistic voltage sensitivities and consequently to predict system nodes with high likelihood of voltage limit violations. The effectiveness of this method is tested on IEEE 69-node distribution system integrated with distributed solar. The results demonstrate the proposed method's ability to successfully predict nodes with high probability of voltage violations for a specific time-series simulation. The results also demonstrate the ability to guide timely power injection control actions to mitigate future voltage violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Neumann Series Based Voltage Sensitivity Analysis for Three Phase Distribution System

In this letter, a simplified voltage sensitivity analysis technique that can provide accurate estimates of voltage change across the network for a given change in bus power injections in a three-phase unbalanced distribution network is proposed. This technique is derived from the first-order approximation of the Neumann series, which allows maintaining the accuracy of the solution while the computational effort is reduced. Here, the proposed technique is tested on a 559-bus unbalanced distribution system with multiple distributed generation resources. The results show that the average error in the voltage estimates with the proposed method is not more than 0.3% with the execution time of similar order relative to the state-of-the-art sensitivity analysis methods.

42 ENGINEERING↗

Probabilistic Voltage Sensitivity Analysis to Quantify Impact of High PV Penetration on Unbalanced Distribution System

From an operational and planning perspective, it is important to quantify the impact of increasing penetration of photovoltaics on the distribution system. Most existing impact assessment studies are scenario-based where derived results are scenario specific and not generalizable. Moreover, stochasticity in the temporal behavior of spatially distributed PVs requires a large number of scenarios that increase with the size of the network and the level of penetration. Therefore, we propose a new computationally efficient analytical framework of voltage sensitivity analysis that allows for stochastic analysis of voltage change due to random changes in PV generation. We first derive an analytical approximation for voltage change at any node of the network due to change in power at other nodes in an unbalanced distribution network. The quality of this approximation is reinforced via bounds on the approximation error. Then, we derive the probability distribution of voltage change at a certain node due to random changes in power injections/consumptions at multiple locations of the network. The accuracy of the proposed PVSA is illustrated using a modified version of the IEEE 37 bus test system. As a result, the proposed PVSA can serve as a powerful tool for proactive monitoring/control and ease the computational burden associated with perturbation based cybersecurity mechanisms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Composite metal-oxide device has voltage sensitive capacitance

Device with step function variation of the capacitance is useful for voltage-controlled oscillator circuits and as a voltage-sensitive switch. Simplicity of construction makes the device suitable for large-scale integration, microelectronic circuits.

Mattauch, R. J.↗

A novel framework for hosting capacity analysis with spatio-temporal probabilistic voltage sensitivity analysis

Smart grids are envisioned to accommodate high penetration of distributed photovoltaic (PV) generation, which may cause adverse grid impacts in terms of voltage violations. Therefore, PV Hosting capacity is being used as a planning tool to determine the maximum PV installation capacity that causes the first voltage violation and above which would require infrastructure upgrades. Additionally, traditional methods of Hosting capacity analysis are scenario based and computationally complex as they rely on iterative load flow algorithms that require investigating a large number of scenarios for accurate assessment of PV impacts. Therefore, this paper presents a computationally efficient analytical approach to compute the probability distribution of voltage change due to random behavior of randomly located multiple distributed PVs. The proposed approach is based on Spatio-temporal probabilistic voltage sensitivity analysis that exploits both spatial and temporal uncertainties associated with PV injections. Thereafter, the derived distribution is used to quantify voltage violations for various PV penetration levels and subsequently determine the hosting capacity of the system without the need to examine large number of scenarios. Results of the proposed framework are validated via conventional load flow based simulation approach on the IEEE 37 and IEEE 123 node test systems.

42 ENGINEERING↗

Local Power-Voltage Sensitivity and Thevenin Impedance Estimation from Phasor Measurements

This paper describes how to use voltage phasor measurements to produce a sensitivity matrix that describes how real and reactive power injections at a node on a distribution network affect the local voltage magnitude and angle. Rather than estimating the sensitivity directly, the voltage phasor measurements and power commands/measurements are used to estimate the unbalanced, three-phase Thevenin impedance. The Thevenin impedance estimation is conducted using recursive least squares on temporal difference measurements. The Thevenin impedance and voltage phasor measurement are then used to build the local power-voltage sensitivity matrix with the closed form expression for the Jacobian of the power flow manifold. Hardware-in-the-loop simulations with phasor measurement units providing real phasor measurements are used to evaluate the recursive temporal difference Thevenin impedance estimation and Thevenin-based power-voltage sensitivity methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Parathyroid hormone enhances fluid shear-induced [Ca2+]i signaling in osteoblastic cells through activation of mechanosensitive and voltage-sensitive Ca2+ channels

Osteoblasts respond to both fluid shear and parathyroid hormone (PTH) with a rapid increase in intracellular calcium concentration ([Ca2+]i). Because both stimuli modulate the kinetics of the mechanosensitive cation channel (MSCC), we postulated PTH would enhance the [Ca2+]i response to fluid shear by increasing the sensitivity of MSCCs. After a 3-minute preflow at 1 dyne/cm2, MC3T3-E1 cells were subjected to various levels of shear and changes in [Ca2+]i were assessed using Fura-2. Pretreatment with 50 nM bovine PTH(1-34) [bPTH(1-34)] significantly enhanced the shear magnitude-dependent increase in [Ca2+]i. Gadolinium (Gd3+), an MSCC blocker, significantly inhibited the mean peak [Ca2+]i response to shear and shear + bPTH(1-34). Nifedipine (Nif), an L-type voltage-sensitive Ca2+ channel (VSCC) blocker, also significantly reduced the [Ca2+]i response to shear + bPTH(1-34), but not to shear alone, suggesting VSCC activation plays an interactive role in the action of these stimuli together. Activation of either the protein kinase C (PKC) or protein kinase A (PKA) pathways with specific agonists indicated that PKC activation did not alter the Ca2+ response to shear, whereas PKA activation significantly increased the [Ca2+]i response to lower magnitudes of shear. bPTH(1-34), which activates both pathways, induced the greatest [Ca2+]i response at each level of shear, suggesting an interaction of these pathways in this response. These data indicate that PTH significantly enhances the [Ca2+]i response to shear primarily via PKA modulation of the MSCC and VSCC.

Non-NASA Center↗

Online Model-Free DER Dispatch Via Adaptive Voltage Sensitivity Estimation and Chance Constrained Programming

This paper proposes an online data-driven distributed energy resource management system (DERMS) for distribution system optimal DER dispatch as well as voltage regulation. Here, the key innovation is to leverage the Local Sensitivity Factor (LSF) for transforming the DER control into a computationally efficient linear programming (LP) problem. By taking real-time measurements, the estimation of LSF eliminates the need for an accurate distribution system model as well as full nodal load information, which is difficult to achieve in practice. A robust recursive least squares method is also developed to ensure the robust estimation of LSF, which is initialized using reasonable values from model-derived LSFs. This allows the system to adapt to changing operational conditions effectively. A scenario-based, chance-constrained framework is further employed to ensure voltage remains within acceptable limits in the presence of measurement and estimation uncertainties. Test results on a real-world, 759-node distribution network located in western Colorado, U.S., validate the effectiveness and robustness of the proposed control approach and demonstrate its superior performance as compared to alternative methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Role of Calcium in the Response of Osteoblasts to Mechanical Stimulation

A major biomedical concern in the exploration and development of space is the rapid loss of bone associated with extended periods of spaceflight. Mineral content, bone formation, matrix protein production and total body calcium are all reduced during long-term periods of weightlessness. These effects of weightlessness appears to be due to decreases in the anabolic function of osteoblasts and osteocytes rather than changes in the resorptive activity of osteoclasts. Conversely, subjecting the skeleton to exogenous mechanical loading increases matrix protein synthesis and bone formation rate, a process which also appears mediated through osteogenic cells. Osteoblasts have been shown to respond to a number of types of mechanical stimulation. However recently we have demonstrated that osteoblasts respond to fluid shear, but not physiologic levels of mechanical strain, with increases in expression of the matrix protein, osteopontin. We have also shown similar responses in other markers for the anabolic response in bone. The expression of the early response gene, c-fos, and the inducible-isoform of the prostaglandin synthetic enzyme, cyclooygenase-2 (COX-2), both increase rapidly in response to fluid shear, but not strain. How osteoblasts and osteocytes perceive mechanical stimuli and convert this stimulus into a biochemical event within the cell is still unknown. However, examination of the cellular events following mechanical stimulation indicate that two of the earliest responses are a rapid increase in intracellular calcium ([Ca(2+)](sub i)) and a reorganization of the actin cytoskeleton. The increase in [Ca(2+)](sub i) is dependent on the presence of extracellular Ca(2+), suggesting the activation of membrane Ca(2+) channel. We have previously characterized a mechanosensitive, cation-selective channel (MSCC) in osteoblast-like clonal cells, which we postulate is important in this early response to mechanical loading. Using an antisense oligodeoxynucleotide strategy, we have tentatively identified this channel as an isoform of the alc subunit of the dihydropyridine-sensitive, voltage sensitive Ca(2+) channel (VSCC). However, a major component in this mechanically induced rise in [Ca(2+)](sub i) is the release of Ca(2+) from intracellular stores. The actin cytoskeleton also rapidly responds to fluid shear with an increase in stress fiber formation and a realignment of the cell parallel to the direction of flow. To ascertain whether these two observations are related and how they effect shear-induced gene expression, we examined the role of Ca(2+) channels and intracellular Ca(2+) release on cytoskeletal reorganization and the resultant increases in the expression and production of c-fos and COX-2 in response to fluid shear.

Duncan, R. L.↗

DERMS Online: A New Voltage Sensitivity-Enabled Feedback Optimization Framework: Preprint

This paper proposes a distributed energy resource management system (DERMS) solution by developing a new voltage sensitivity enabled feedback optimization framework. The key idea is to adopt a measurement feedback scheme to reformulate the original nonlinear optimization into a linear programming (LP) problem via perturb and observe-based voltage sensitivity analysis. The proposed solution eliminates the dependence on load knowledge and can be implemented online thanks to an efficient open-source solver for LP problems. The proposed DERMS online platform is generalizable to deal with various types of distributed energy resources (DERs), including distributed photovoltaics (PVs), energy storage, electric vehicles, demand response, etc. Comparison results with other control methods on a realistic distribution feeder in Southern California highlight the feasibility as well as benefits for the proposed framework.

distributed energy resources management↗

DERMS Online: A New Voltage Sensitivity-Enabled Feedback Optimization Framework

This paper proposes a distributed energy resource management system (DERMS) solution by developing a new voltage sensitivity-enabled feedback optimization framework. The key idea is to adopt a measurement feedback scheme to reformulate the original nonlinear optimization into a linear programming (LP) problem via perturb-and-observe-based voltage sensitivity analysis. The proposed solution eliminates the dependence on load knowledge and can be implemented online thanks to an efficient open-source solver for LP problems. Comparison results with other control methods on a real distribution feeder in Southern California highlight the feasibility as well as benefits for the proposed framework.

distributed energy resource management↗

A red-emitting carborhodamine for monitoring and measuring membrane potential

Biological membrane potentials, or voltages, are a central facet of cellular life. Optical methods to visualize cellular membrane voltages with fluorescent indicators are an attractive complement to traditional electrode-based approaches, since imaging methods can be high throughput, less invasive, and provide more spatial resolution than electrodes. Recently developed fluorescent indicators for voltage largely report changes in membrane voltage by monitoring voltage-dependent fluctuations in fluorescence intensity. However, it would be useful to be able to not only monitor changes but also measure values of membrane potentials. This study discloses a fluorescent indicator which can address both. We describe the synthesis of a sulfonated tetramethyl carborhodamine fluorophore. When this carborhodamine is conjugated with an electron-rich, methoxy (-OMe) containing phenylenevinylene molecular wire, the resulting molecule, CRhOMe, is a voltage-sensitive fluorophore with red/far-red fluorescence. Using CRhOMe, changes in cellular membrane potential can be read out using fluorescence intensity or lifetime. In fluorescence intensity mode, CRhOMe tracks fast-spiking neuronal action potentials (APs) with greater signal-to-noise than state-of-the-art BeRST 1 (another voltage-sensitive fluorophore). CRhOMe can also measure values of membrane potential. The fluorescence lifetime of CRhOMe follows a single exponential decay, substantially improving the quantification of membrane potential values using fluorescence lifetime imaging microscopy (FLIM). The combination of red-shifted excitation and emission, mono-exponential decay, and high voltage sensitivity enable fast FLIM recording of APs in cardiomyocytes. The ability to both monitor and measure membrane potentials with red light using CRhOMe makes it an important approach for studying biological voltages.

59 BASIC BIOLOGICAL SCIENCES↗