Isothermal method for volume determination
Isothermal volume measurements for weight computation on monkeys
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Isothermal volume measurements for weight computation on monkeys
Inflight urine volume determination using lithium or cesium salts as tracer materials and atomic absorption spectrophotometry for determining tracers
The feasibility, functionality, and overall accuracy of the use of lithium were investigated as a chemical tracer in urine for providing a means of indirect determination of total urine volume by the atomic absorption spectrophotometry method. Experiments were conducted to investigate the parameters of instrumentation, tracer concentration, mixing times, and methods for incorporating the tracer material in the urine collection bag, and to refine and optimize the urine tracer technique to comply with the Skylab scheme and operational parameters of + or - 2% of volume error and + or - 1% accuracy of amount of tracer added to each container. In addition, a back-up method for urine collection and sampling system was developed and evaluated. This back-up method incorporates the tracer technique for volume determination in event of failure of the primary urine collection and preservation system. One chemical preservative was selected and evaluated as a contingency chemical preservative for the storage of urine in event of failure of the urine cooling system.
Blood samples were obtained from forearm vein or artery with indwelling cannula (1) before, (2) during the last min, and (3) about 2 min after lower body negative pressure (LBNP) in 16 experiments to determine whether plasma volume (PV) estimates were affected by regional hemoconcentration in the lower body. Total hemoglobin (THb) was estimated with the CO method prior to LBNP. Hemoglobin (Hb) and hematocrit (Hct) values from (2) gave only a 3% (87 ml) loss in PV due to LBNP, assuming no change in THb. However, Hb and Hct values from (3) showed an 11% loss in PV (313 ml). This 72% underestimation of PV loss with (2) must have resulted from the sequestration of blood and subsequent hemoconcentration in the lower body during LBNP. The effects of LBNP on PV should be estimated 1-3 min after exposure, after mixing but before extravascular fluid returns to the circulation.
The development and testing of two techniques for determination of apparent and rim crest volumes of impact and explosion craters are described. The accuracy of the techniques, their relative costs, and the time required to complete the volume calculations are compared.
Explore the source record for details and available documents.
In this paper, the development of a fission-gas collecting and physical-analysis-enabling instrument was proposed for small-volume determination. Analysis specifications require a design capable of accurately and repeatably determining volumes in the range of 0.07–2.5 mL. This system relies on a series of gas expansions originating from a cylinder with known internal volume. The combined gas law is used to derive the unknown volumes from these expansions. Initial system designs included one of two known volumes, 11.85 ± 0.34 mL and 5.807 ± 0.078 mL, with a manifold volume of 32 mL. Results obtained from modeling this system’s operation showed that 0.07 mL can be determined with a relative expanded uncertainty greater than 300% (k = 2) for a single replicate, which was unacceptable for the proposed experimental design. Initial modeling showed that the volume connecting the known volume and rodlet, i.e., the manifold volume, and the sensitivity of the pressure sensor were key contributors to the expanded uncertainty of the measured rodlet volume. The system’s design limited the available options for pressure sensors, so emphasis was placed on the design of the manifold volume. The final system design reduced the manifold volume to 17 mL. These changes in design, combined with replicate analysis, were able to reduce the relative expanded uncertainty by ±12% (k = 2) for the 0.07 mL volume.
Volume fraction of a constituent or phase was estimated in six specimens of conventional and DS-eutectic superalloys, using ASTM E562-76, a new standard recommended practice for determining volume fraction by systematic manual point count. Volume fractions determined ranged from 0.086 to 0.36, and with one exception, the 95 percent relative confidence limits were approximately 10 percent of the determined volume fractions. Since the confidence-limit goal of 10 percent, which had been arbitrarily chosen previously, was achieved in all but one case, this application of the new practice was considered successful.
The pulse-contour method for determining stroke volume has been employed as a continuous rapid method of monitoring the cardiovascular status of patients. Twenty-one patients with ischemic heart disease and 21 patients with mitral valve disease were subjected to a variety of hemodynamic interventions. The pulse-contour estimations, using three different formulas derived by Warner, Kouchoukos, and Herd, were compared with indicator-dilution outputs. A comparison of the results of the two methods for determining stroke volume yielded correlation coefficients ranging from 0.59 to 0.84. The better performing Warner formula yielded a coefficient of variation of about 20%. The type of hemodynamic interventions employed did not significantly affect the results using the pulse-contour method. Although the correlation of the pulse-contour and indicator-dilution stroke volumes is high, the coefficient of variation is such that small changes in stroke volume cannot be accurately assessed by the pulse-contour method. However, the simplicity and rapidity of this method compared to determination of cardiac output by Fick or indicator-dilution methods makes it a potentially useful adjunct for monitoring critically ill patients.
A system and method are provided for determining the volume of a fluid in container. Sensors are positioned at distinct locations in a container of a fluid. Each sensor is sensitive to an interface defined by the top surface of the fluid. Interfaces associated with at least three of the sensors are determined and used to find the volume of the fluid in the container in a geometric process.
Previous experience during the Apollo postflight exercise testing indicated no major changes in pulmonary function. Although pulmonary function has been studied in detail following exposure to hypoxic and hyperoxic environments, few studies have dealt with normoxic environments at reduced total pressure as encountered during the Skylab missions. Forced vital capacity was measured during the preflight and postflight periods of the Skylab 2 mission. Initial in-flight measurements of vital capacity were obtained during the last two weeks of the second manned mission (Skylab 3). Comprehensive pulmonary function screening was accomplished during the Skylab 4 mission. The primary measurements made during Skylab 4 testing included residual volume determination, closing volume, vital capacity, and forced vital capacity and its derivatives. In addition, comprehensive in-flight vital capacity measurements were made during the Skylab 4 mission. Vital capacity was decreased slightly during flight in all Skylab 4 crewmen. No major preflight to postflight changes were observed in the other parameters.
Ultrasonic echography for ventricular size determination, calculating stroke volume and valvular regurgitation severity
The determination of the volume fraction of a second phase in a multiphase sample by X-ray diffraction becomes more difficult if the diffracting planes have a preferred orientation. Lopata and Kula have described a method of treating this problem using complete pole figures for each of the phases. With some samples, it is not always possible or convenient to obtain data over the full hemisphere. Equations and an example are given which require X-ray data over a limited range of approximately 0 to 75 deg. This can be obtained by reflection without a specially cut sample or transmission data. A series of Legendre polynomials are fitted to data collected while spinning the sample about its normal. An extrapolation is made possible by introducing two conditions on the end points which must be satisfied if the extrapolation functions are to be valid.
An instrument is described for the continuous volume measurement of small (3.7 ml) samples of liquids as a function of temperature. The sample is sealed in a stainless steel bellows chamber. Volume changes are measured with a linear variable differential transformer while temperature is measured by means of a thermistor and associated circuitry. Volume changes can be determined to better than .1 microliter ml over a temperature range of 10-60 C. The maximum sample volume change is 7%.
The volume of earth's oceans may be determined by a dynamic mechanism involving exchange of water between the crust and the mantle. Fast-spreading mid-ocean ridges are currently submerged to a depth at which the pressure is close to the critical pressure for seawater. This ensures optimal convective heat transport and, hence, maximal penetration of hydrothermal circulation along the ridge axes. The oceanic crust is hydrated to a depth of a kilometer or more and can therefore carry a substantial flux of water to the upper mantle when it is subducted. The current ingassing rate of water by this process is probably at least sufficient to balance the outgassing rate. If the oceans were shallower, as they may have been in the distant past, convective heat transport would be reduced and the depth of hydrothermal penetration and crustal hydration would decrease. Outgassing would exceed ingassing and ocean volume would increase. The system is self-stabilizing as long as the depth of the oceans does not exceed its present value. This mechanism could explain why continental freeboard has remained approximately constant since the Archean despite probable increases in continental area.
Subroutine descriptions and listing for FORTRAN 4 orbit determination program - A through F
Subroutine descriptions and listing for FORTRAN 4 orbit determination program - G through Z
The performance capability of each of two precision attitude determination systems (PADS), one using a strapdown star tracker, and the other using a single-axis gimbal star tracker was measured in the laboratory under simulated orbit conditions. The primary focus of the evaluation was on the contribution to the total system accuracy by the star trackers, and the effectiveness of the software algorithms in functioning with actual sensor signals. A brief description of PADS, the laboratory test configuration and the test facility, is given along with a discussion of the data handling and display, laboratory computer programs, PADS performance evaluation programs, and the strapdown and gimbal system tests. Results are presented and discussed.