ResStock Measure Documentation: Advanced Air Sealing, Attic Floor Insulation, Duct Sealing and Insulation, and Drill-and-Fill Wall Insulation

This report is part of a series describing different ResStock measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Advanced Air Sealing, Attic Floor Insulation, Duct Sealing and Insulation, and Drill-and-Fill Wall Insulation" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

ResStock Measure Documentation: Advanced Air Sealing With Drill-and-Fill Wall Insulation

This report is part of a series describing different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Air Sealing With Drill-and-Fill Wall Insulation" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation and New Windows

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Window Replacement, Exterior Wall Insulation, and Roof Insulation, which we will refer to collectively as the "High Efficiency Envelope" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Numerical investigation of two-dimensional buoyancy-driven eddies in liquid metal magnetohydrodynamic flows in breeding blankets *

Abstract Lead–lithium flows are key features in the design of tokamak breeding blanket concepts such as the dual-coolant lead–lithium (DCLL). Since they flow under magnetic fields, they are affected by magnetohydrodynamic (MHD) effects. The neutron flux originating in the tokamak plasma heats the breeding blanket channels in a non-uniform manner, inducing buoyancy forces in the liquid metal. Buoyancy may become a source of quasi-two-dimensional (Q2D) turbulence, and the appearance of eddies may affect the transport of heat and tritium across the blanket. Blankets characterized by high-speed liquid metal flows (such as DCLL) will need ceramic insulating walls to reduce the MHD-related pressure drop in the channels. In our simulations, we have used the Q2D model proposed by Sommeria and Moreau (SM82) which is especially suitable for modeling electrically insulating channel flows. On top of that, we have modelled buoyancy forces in the momentum equation using the Oberbeck–Boussinesq approximation. In this work, we include a validation of the implemented Q2D model in buoyancy-driven cases and identify a thermohydraulic configuration that promotes the generation of eddies and the accumulation of tritium. We also show the results provided by our post-processing tool based on the bi-dimensional fast Fourier transform for eddy detection and characterization. We complete our investigation by performing an initial assessment of how eddies can accumulate tritium in the breeding blanket. We conclude by discussing the relevance of preventing accumulation of tritium within the blanket and suggest a possible solution.

Suarez, Daniel (ORCID:0000000251740100)

Measuring Impact: Evaluating Thermal Zoning Simplification on Energy Efficiency Measures Analysis

Building Energy Modeling (BEM) is a versatile tool for designing, retrofitting, ensuring code compliance, obtaining certifications, qualifying for incentives, and enabling real-time building control. However, capturing all the details of building geometry for thermal zoning can be time-consuming, costly, and sometimes computationally challenging. As a result, modelers have been applying zoning simplification based on factors such as space functions and internal loads, as well as relying on their experience and judgment while adhering to zoning rules outlined in industry standards. Despite the prevalence of this common practice, a notable gap exists in the literature regarding studies quantifying the influence of simplified thermal zoning on the evaluation of Energy Efficiency Measures (EEMs). Recognizing this gap, this paper seeks to contribute to the field by enhancing the understanding of how the simplification of thermal zoning influences the evaluation of EEMs against a baseline design. The study utilized a medium office prototype model with a detailed floor plan featuring over 20 zones per floor covering diverse functional spaces with varying internal loads and occupancy schedules. A standard thermal zoning strategy outlined in ASHRAE Standard 90.1 Appendix G was employed as the simplified zoning method. This strategy condenses the zoning into a core zone and four perimeter zones per floor. It was compared with the detailed zoning approach, which involves one zone per space. Common Energy EEMs, such as enhanced envelope, high-efficiency appliances and equipment, and HVAC controls, were individually implemented and evaluated. The results indicate that the performance comparison between the two zoning methods varies depending on the type of measures considered. Basic measures, such as adding wall insulation, demonstrate similar energy impacts, while advanced HVAC control measures, such as static pressure reset, exhibit a more substantial difference that cannot be overlooked.

Xie, Jiarong

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation, New Windows, LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility enduse load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. “Measures” refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

First ARM Mobile Facility (AMF1) Aerosol Observing System (AOS01) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility Mobile Aerosol Observing System – Aerosols (MAOS-A), designated AOS01, entered service in March of 2012 at the Los Alamos National Laboratory for the Pajarito Aerosol Coupling to Ecosystems (PACE) field campaign. The Aerosol Observing System is meant to be a standalone, completely autonomous, aerosol sampling system. It requires only power, 208VAC 1φ or 440 VAC 1φ, and an internet connection to be operational. The physical structure is a standard-sized shipping container, 20 feet long by 8 feet wide. Inside, the walls, ceiling, and floor are insulated using >3.5” of spray polyurethane foam with an R-value of 6.2/inch of insulation. The interior walls, floor and ceiling are lined with ¾” plywood for durability and have integrated unistrut for mounting equipment.

54 ENVIRONMENTAL SCIENCES

Next generation retrofit wall panels with integrated vacuum insulation panels

Approximately two-thirds of residential buildings in the United States were constructed before the Department of Energy established energy conservation measures. These buildings present major opportunities for improving energy efficiency, though retrofitting them remains technically and economically challenging. This study presents the development and the durability evaluation of an innovative retrofit panel system that integrates vacuum insulation panels (VIP) with a nail-base panel (called a retrofit insulated panel) to enhance thermal performance with minimal disruption to occupants and without altering standard nail-based panel installation practices. Hygrothermal simulations were conducted to assess the moisture behavior of wall assemblies before and after retrofit installation under varying water vapor control strategies and climate conditions. Results indicate that, with appropriate moisture control strategy, the retrofit system effectively prevents moisture accumulation, keeping mold index values and relative humidity levels below critical thresholds. Additionally, Guarded Hot Box testing was performed to compute the effective R-value of the panel under different coverage areas that demonstrates its effectiveness in enhancing both thermal and moisture performance in existing residential buildings.

Iffa, Emishaw [ORNL]

Energy Efficiency Field Study: Influence of Key Measures in Home Rules States

The goal of the Energy Efficiency Field Study: Influence of Key Measures in Home Rule States project is to empower and support the states of Utah and Arizona in the successful implementation of their building energy codes. Employing the Department of Energy (DOE) Residential Building Energy Code Field Study Data Collection & Methodology, the research team evaluated real-world implementation status against a baseline, with a particular focus on the unique challenges presented by the dry, hot climates of Utah and Arizona.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Mesoporous optically clear heat insulators for sustainable building envelopes

Mesoporous materials exhibit highly controlled nanoscale structures, often templated by liquid crystalline assemblies of surfactants, with emergent and often designable physical properties. However, scaling their fabrication to be suitable for uses like envelopes of buildings is challenging. Here we describe fabrication of flexible square-meter-sized films and multi-centimeter-thick slabs made of three-dimensional spatial graphs of mesopore tubes having all structural features under 50 nanometers. Solution-based kinetic fabrication process templates growing networks of cylindrical surfactant micelles with thin tubes of polysiloxane forming gel networks and, upon replacing surfactants and solvents with air, yields lightweight materials with >99% visible-range optical transparency and ~10 mW K-1m-1 thermal conductivity. Such predesigned metamaterials enable transparent thermal barriers for wall-grade insulated glass units, square-meter window retrofits and unconcentrated solar thermal energy harnessing.

14 SOLAR ENERGY

Ion diffusion retarded by diverging chemical susceptibility

Abstract For first-order phase transitions, the second derivatives of Gibbs free energy (specific heat and compressibility) diverge at the transition point, resulting in an effect known as super-elasticity along the pressure axis, or super-thermicity along the temperature axis. Here we report a chemical analogy of these singularity effects along the atomic doping axis, where the second derivative of Gibbs free energy (chemical susceptibility) diverges at the transition point, leading to an anomalously high energy barrier for dopant diffusion in co-existing phases, an effect we coin as super-susceptibility. The effect is realized in hydrogen diffusion in vanadium dioxide (VO 2 ) with a metal-insulator transition (MIT). We show that hydrogen faces three times higher energy barrier and over one order of magnitude lower diffusivity when it diffuses across a metal-insulator domain wall in VO 2 . The additional energy barrier is attributed to a volumetric energy penalty that the diffusers need to pay for the reduction of latent heat. The super-susceptibility and resultant retarded atomic diffusion are expected to exist universally in all phase transformations where the transformation temperature is coupled to chemical composition, and inspires new ways to engineer dopant diffusion in phase-coexisting material systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Electrical signaling in fungi: past and present challenges

Abstract Electrical signaling is a fundamental mechanism for integrating environmental stimuli and coordinating responses in living organisms. While extensively studied in animals and plants, the role of electrical signaling in fungi remains a largely underexplored field. Early studies suggested that filamentous fungi generate action potential-like signals and electrical currents at hyphal tips, yet their function in intracellular communication remained unclear. Renewed interest in fungal electrical activity has fueled developments such as the hypothesis that mycorrhizal networks facilitate electrical communication between plants and the emerging field of fungal-based electronic materials. Given their continuous plasma membrane, specialized septal pores, and insulating cell wall structures, filamentous fungi possess architectural features that could support electrical signaling over long distances. However, studying electrical phenomena in fungal networks presents unique challenges due to the microscopic dimensions of hyphae, the structural complexity of highly modular mycelial networks, and the limitations of traditional electrophysiological methods. This review synthesizes current evidence for electrical signaling in filamentous fungi, evaluates methodological approaches, and highlights experimental challenges. By addressing these challenges and identifying best practices, we aim to advance research in this field and provide a foundation for future studies exploring the role of electrical signaling in fungal biology.

Buffi, Matteo

Néel domain walls with bistable chirality in a perpendicularly magnetized ferrimagnetic insulator

Field-free spin-orbit torque-driven domain wall motion in magnetic thin films with perpendicular magnetic anisotropy (PMA) requires the domain walls to have Néel character. Conventionally, Néel domain walls are stabilized by the Dzyaloshinskii-Moriya interaction (DMI) in ultrathin films. Here, in a europium iron garnet thin film with PMA and an additional uniaxial in-plane anisotropy, we demonstrate two bistable Néel domain wall states in the absence of DMI, and the capability to toggle the wall states with an in-plane field pulse and consequently their directions of motion under a current pulse. We present a phase diagram for the bistable Néel domain wall states as a function of in-plane field pulse width and amplitude. By fitting the experimental data to an analytical model of Néel wall reversal through the nucleation and propagation of Bloch lines, we extract the length of the initial reversed domain wall segment and Bloch line nucleation energy barrier. Current-driven motion of in-plane anisotropy stabilized Néel walls is qualitatively different from that of DMI-stabilized ones owing to the different symmetry of the effective fields that stabilize the Néel configuration. Furthermore, we present a proof of principle demonstration for 2-bit random number generation based on the stochastic reversal of domain wall chirality. These results provide critical insight into the topological energy barrier of Bloch lines and identify paths towards domain wall-based memory and computing devices.

36 MATERIALS SCIENCE

Hydronic Shell: An Affordable Solution for Multifamily Deep Energy Retrofit

Approximately 42% of multi-family buildings in the United States have do not have insulation as required by the building codes. Envelope retrofits of these buildings are needed to improve their thermal performance, provide thermal resilience, and enable a pathway to electrification of space heating systems. Hydronic shell (HS) is a retrofit technique where a stud wall layer is added to a masonry wall along with a convective coil and a fan coil unit fitted in the façade cavity which can provide both heating and cooling to the space. The HS system serves a dual purpose of 1) retrofitting the building envelope and 2) retrofitting the HVAC system and enabling electrification of space heating. The electrification of space heating is possible from the installation of a combination of hydronic system/fan coil unit system which uses a central heat pump as a source of heating water in the cavity between the existing wall and retrofit insulation layer. This study evaluates the performance of the HS system at varying outdoor conditions mimicked by a climate chamber and hot water supply temperature from a water bath. During the ramp-up period, the indoor chamber temperature could be increased from 66 ºF to 69.5 ºF within an hour using heating water at 120 ºF when the outdoor chamber temperature was at 0 ºF. When the indoor chamber temperature was maintained within a deadband, variation in cavity air temperature was mostly influenced by the duration when water was flowing through the cavity convector. It was seen from the testing that the hydronic system alone without use of fan in the system is able to maintain the space temperature at coldest outdoor condition used in the experiment (0 ºF) even at lowest hot water supply temperature chosen (90 ºF). During the ramp-down period, the fastest decline in temperature took 6.4 hours from temperature to drop from 69.6 ºF to 66 ºF which shows tremendous potential of thermal resilience and peak load shifting.