Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Simulated Waste for Leaching and Filtration Studies--Laboratory Preparation Procedure

This report discusses the simulant preparation procedure for producing multi-component simulants for leaching and filtration studies, including development and comparison activities in accordance with the test plan( ) prepared and approved in response to the Test Specification 24590-WTP-TSP-RT-06-006, Rev 0 (Smith 2006). A fundamental premise is that this approach would allow blending of the different components to simulate a wide variety of feeds to be treated in the Hanford Tank Waste Treatment and Immobilization Plant (WTP). For example, a given feed from the planned feed vector could be selected, and the appropriate components would then be blended to achieve a representation of that particular feed. Using the blending of component simulants allows the representation of a much broader spectrum of potential feeds to the Pretreatment Engineering Platform (PEP).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of an S-Saltcake Simulant Using Crossflow Filtration as a Validation Technique

In the past several years, cross-flow filtration has been studied extensively in a bench-scale system at Pacific Northwest National Laboratory (PNNL) using both actual tank waste from the Hanford site and waste simulants. One challenge when creating a waste simulant is duplicating the filtration behaviour of real waste, in particular when the waste composition is not known with certainty. Using a systematic approach to filtration testing, it has been found that the solid components that dominate the filtration behaviour can be identified. This approach was used to develop a waste simulant for S-Saltcake tank waste. The analysis of filtration data assists in screening solid components when the chemical composition and structure of a metal is not known. This is well-illustrated in this study during the search for the appropriate chromium phase. After the likely components were identified, the solids were combined with a supernate that is representative of the real waste and the filtration performance was verified against real waste data. A secondary benefit of this approach is the construction of a database of filtration performance for various solid species that can be used to quickly develop waste simulants in the future.

waste simulant, crossflow filtration, S-Saltcake↗

Filtration Performance of Simulated 200 West Area Waste Feeds

This report describes the scaled experimental system and approach used to examine dead-end filtration performance of representative 200W waste feeds. The scaled system, which was originally designed and assembled to test Tank Side Cesium Removal (TSCR) system performance with higher-than-expected solid loadings in 2021 (Schonewill et al. 2021), was repurposed to conduct the current experiments at ~1/145 of full scale (based on throughput). Six experimental runs were conducted with five different 200W waste feed simulants: three using a DEF module scaled for TSCR and three using a DEF module scaled for the 200W process modules (based on the current design for the Advanced Modular Pretreatment System). Each experiment was run continuously for multiple days with an operating approach prototypic of the full-scale system. Staff performing the experimental runs monitored performance, obtained data from calibrated process instruments, and collected samples for observation and analysis. The measured data are presented with a focus on assessing DEF performance – specifically, the filters’ differential pressure response to the five waste simulants, frequency and efficacy of backwashing, and baseline recovery between experimental runs; data related to ion exchange column performance are also discussed in cases where the opportunity arose. The experimental campaign demonstrated that the DEFs satisfied their primary function of protecting the ion exchange column from solid intrusion for all the representative simulants used. The filters readily handled solids loadings of =500 ppm (and even greater), especially the modules scaled to the 200W process modules. Adjustments to the processing flow rate and reductions in feed temperature were observed to affect the rate of differential pressure increase on the filters, but neither adversely affected the ability of the DEFs to perform their primary function. Backflushing reliably recovered filter performance in all runs, although it did not prevent irreversible fouling for one simulant. The run that exhibited irreversible fouling established that both the quantity and the nature of the solids being filtered need to be considered when projecting filter performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrated pore blockage-cake filtration model for crossflow filtration

Crossflow filtration is to be a key process in the treatment and disposal of approximately 60,000 metric tons of high-level radioactive waste stored at the Hanford Site in Richland, Washington. Pacific Northwest National Laboratory is assessing filter performance with waste simulant materials that mimic the chemical and physical properties of Hanford tank waste. Prior simulant studies indicated that waste filtration performance may be limited by pore and cake fouling. To limit the shutdown of waste treatment operations, the pre-treatment facility plans to recover filter flux losses from cake formation and filter fouling by frequently backpulsing the filter elements. The objective of the current paper is to develop a simple model of flux decline resulting from cake and pore fouling and potential flux recovery through backpulsing of the filters for Hanford waste filtration operations. To this end, a model capable of characterizing the decline in waste-simulant filter flux as a function of both irreversible pore blockage and reversible cake formation is proposed. This model is used to characterize the filtration behavior of Hanford waste simulants in both continuous and backpulsed operations. The model is then used to infer the optimal backpulse frequency under specific operating conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of dilution-induced precipitates on the filtration of Hanford liquid tank wastes

To facilitate its vitrification, a portion of the radioactive wastes currently stored at the Hanford Site will be staged and treated using tank-side operations to render their chemistry compliant with the requirements of Hanford’s low-activity waste vitrification facility. Initial sampling of staged feeds indicates that process-water dilution, used to reduce waste feed sodium content to levels acceptable for vitrification (5–6 M Na), may cause precipitation of fine, difficult to settle solids that could affect downstream tank-side filtration and ion-exchange. However, dilution-induced precipitation has not been demonstrated under controlled, rigorous laboratory conditions. This paper presents a set of qualitative and quantitative assessments of dilution-induced precipitation using a nonradioactive, Hanford Tank AP-105 simulated waste. Further, these studies found that dilution of AP-farm waste simulants induced precipitation of up to 150 ppm solids, regardless of whether dilution was done with process water (which contains, among other analytes, naturally occurring Ca and Mg) or deionized water. Naturally occurring process-water analytes appeared to accelerate the rate (and possibly extent) of precipitation. Filtration of diluted waste simulants also found that the precipitated solids challenged prototypic tank-side filter operations; however, the impact to filtration performance was readily managed through waste staging settle/decant operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Crossflow Filtration of LAWPS Simulants

The Low-Activity Waste Pretreatment System (LAWPS) will employ crossflow filtration (CFF) to separate solids from radioactive wastes. Design verification of CFF unit operations will involve engineering-scale demonstrations of the efficacy of liquid-solid separations with low-activity waste (LAW) simulants. Before execution of integrated engineering-scale verification tests, the LAW simulants developed to support design verification activities are to be evaluated in a laboratory-scale CFF apparatus to demonstrate simulant suitability, to help refine engineering-scale filtration and filter cleaning strategies prior to implementation, and to identify any anomalous filtration behaviors that could impact the conduct-of-operations at the engineering-scale test facility. This report provides the bench-scale test results for the four LAWPS simulants developed to support integrated testing and of the eight fouling simulants selected to evaluate the sustainability of LAWPS filtration and the effectiveness of LAWPS flux recovery technologies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Filtration Scale-Up Performance

The scale-up performance of sintered stainless steel crossflow filter elements planned for use at the Pretreatment Engineering Platform (PEP) and at the Waste Treatment and Immobilization Plant (WTP) were characterized in partial fulfillment (see Table S.1) of the requirements of Test Plan TP RPP WTP 509. This test report details the results of experimental activities related only to filter scale-up characterization. These tests were performed under the Simulant Testing Program supporting Phase 1 of the demonstration of the pretreatment leaching processes at PEP. Pacific Northwest National Laboratory (PNNL) conducted the tests discussed herein for Bechtel National, Inc. (BNI) to address the data needs of Test Specification 24590-WTP-TSP-RT-07-004. Scale-up characterization tests employ high-level waste (HLW) simulants developed under the Test Plan TP-RPP-WTP-469. The experimental activities outlined in TP-RPP-WTP-509 examined specific processes from two broad areas of simulant behavior: 1) leaching performance of the boehmite simulant as a function of suspending phase chemistry and 2) filtration performance of the blended simulant with respect to filter scale-up and fouling. With regard to leaching behavior, the effect of anions on the kinetics of boehmite leaching was examined. Two experiments were conducted: 1) one examined the effect of the aluminate anion on the rate of boehmite dissolution and 2) another determined the effect of secondary anions typical of Hanford tank wastes on the rate of boehmite dissolution. Both experiments provide insight into how compositional variations in the suspending phase impact the effectiveness of the leaching processes. In addition, the aluminate anion studies provide information on the consequences of gibbsite in waste. The latter derives from the expected fast dissolution of gibbsite relative to boehmite. This test report concerns only results of the filtration performance with respect to scale-up. Test results for boehmite dissolution kinetics and filter fouling are reported elsewhere (see Table S.1). The primary goal of scale-up testing was to examine how filter length influenced permeate flux rates. To accomplish this, the existing cells unit filter system, which employs a 2-ft-long, 0.5-in. (inner) diameter sintered stainless steel filter element, was redesigned to accommodate an 8-ft. sintered stainless steel filter element of the same diameter. Testing was then performed to evaluate the filtration performance of waste simulant slurries. Scale-up testing consisted of two separate series of filtration tests: 1) scale-up axial velocity (AV)/transmembrane pressure (TMP) matrix tests and 2) scale-up temperature tests. The AV/TMP matrix tests examined filtration performance of two different waste simulant slurries in the 8-ft. cells unit filter system. Waste simulant slurry formulations for the 8-ft. scale-up test was selected to match simulant slurries for which filtration performance had been characterized on the 2-ft CUF. For the scale-up temperature tests, the filtration performance at three test temperatures (i.e., 25°C, 40°C, and 60°C) was determined to evaluate if filter flux versus temperature correlations developed using the 2-ft filters were also valid for the 8-ft filters.

36 MATERIALS SCIENCE↗

Complex Microfiltration Behavior of Metal Hydroxide Slurries

Crossflow filtration is to be a key process in the treatment and disposal of approximately 60,000 metric tons of high-level waste stored at the Hanford Site in Richland, Washington. Pacific Northwest National Laboratory is assessing filter performance against waste simulant materials that mimic the chemical and physical properties of Hanford tank waste. Prior simulant studies indicate that waste filtration performance may be limited by pore and cake fouling. To limit the shutdown of waste treatment operations, the pre-treatment facility plans to recover filter flux loses from cake formation and filter fouling by frequently backpulsing the filter elements. The objective of the current research is to develop an understanding of the roles of cake and pore fouling and potential flux recovery through backpulsing of the filters for Hanford waste filtration operations. Metal hydroxide wastes were tested to examine the role of particle-filter interaction on filter performance.

Hanford Site↗

Filtration and Leach Testing for PUREX Cladding Sludge and REDOX Cladding Sludge Actual Waste Sample Composites

A testing program evaluating actual tank waste was developed in response to Task 4 from the M-12 External Flowsheet Review Team (EFRT) issue response plan (Barnes and Voke 2006). The test program was subdivided into logical increments. The bulk water-insoluble solid wastes that are anticipated to be delivered to the Hanford Waste Treatment and Immobilization Plant (WTP) were identified according to type such that the actual waste testing could be targeted to the relevant categories. Under test plan TP RPP WTP 467 (Fiskum et al. 2007), eight broad waste groupings were defined. Samples available from the 222S archive were identified and obtained for testing. Under this test plan, a waste testing program was implemented that included: • Homogenizing the archive samples by group as defined in the test plan. • Characterizing the homogenized sample groups. • Performing parametric leaching testing on each group for compounds of interest. • Performing bench-top filtration/leaching tests in the hot cell for each group to simulate filtration and leaching activities if they occurred in the UFP2 vessel of the WTP Pretreatment Facility. This report focuses on a filtration/leaching test performed using two of the eight waste composite samples. The sample groups examined in this report were the plutonium-uranium extraction (PUREX) cladding waste sludge (Group 3, or CWP) and reduction-oxidation (REDOX) cladding waste sludge (Group 4, or CWR). Both the Group 3 and 4 waste composites were anticipated to be high in gibbsite, thus requiring caustic leaching. WTP RPT 167 (Snow et al. 2008) describes the homogenization, characterization, and parametric leaching activities before benchtop filtration/leaching testing of these two waste groups. Characterization and initial parametric data in that report were used to plan a single filtration/leaching test using a blend of both wastes. The test focused on filtration testing of the waste and caustic leaching for aluminum, in the form of gibbsite, and its impact on filtration. The initial sample was diluted with a liquid simulant to simulate the receiving concentration of retrieved tank waste into the UFP2 vessel (< 10 wt% undissolved solids). Filtration testing was performed on the dilute waste sample and dewatered to a higher solids concentration. Filtration testing was then performed on the concentrated slurry. Afterwards, the slurry was caustic leached to remove aluminum present in the undissolved solid present in the waste. The leach was planned to simulate leaching conditions in the UFP2 vessel. During the leach, slurry supernate samples were collected to measure the dissolution rate of aluminum in the waste. After the slurry cooled down from the elevated leach temperature, the leach liquor was dewatered from the solids. The remaining slurry was rinsed and dewatered with caustic solutions to remove a majority of the dissolved aluminum from the leached slurry. The concentration of sodium hydroxide in the rinse solutions was high enough to maintain the solubility of the aluminum in the dewatered rinse solutions after dilution of the slurry supernate. Filtration tests were performed on the final slurry to compare to filtration performance before and after caustic leaching.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of gel concentration on filter fluxes in microfiltration of Hanford tank wastes and simulants

Abstract Treatment processes have been proposed that will utilize crossflow filtration to concentrate sludge waste streams at the Department of Energy's Hanford Site. Challenges associated with solid–liquid separation of the waste streams drive a necessary evaluation of available Hanford high level waste (HLW) filtration data. Limiting flux conditions during crossflow filtration are elucidated with the formation of a cake layer on the membrane surface. A mass transfer coefficient between the gel and bulk concentrations plays a critical role in determining filter flux. A correlation between the gel concentration and mass transfer coefficient is made to assist in determining filter performance of select HLW streams. As a process alternative to crossflow filtration, gravity settling of waste streams may be deployed as a solid–liquid separation technique. However, this results in a contrasting performance with the centrifuged solids concentration. A method was developed to estimate expected filtration and settling performance based on physical characterization data for Hanford tank waste samples. By assessing the estimated processing performance of HLW, technical support can be provided during flowsheet planning.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EVALUATION OF ALTERNATIVE FILTER MEDIA FOR THE ROTARY MICROFILTER

SRS is currently developing and testing several processes to treat high level radioactive liquid waste. These processes include the Integrated Salt Disposition Process (ISDP), the Salt Waste Processing Facility (SWPF), and the Small Column Ion Exchange Process (SCIX). Each of these processes has a solid-liquid separation process that limits its throughput. SRNL researchers identified and tested the rotary microfilter as a technology to increase solid-liquid separation throughput. The testing showed significant improvement in filter flux with the rotary microfilter over the baseline crossflow filter (i.e., 2.5-6.5X during scoping tests, as much as 10X in actual waste tests, and approximately 3X in pilot-scale tests). SRNL received funding from DOE EM-21, and subsequently DOE EM-31 to develop the rotary microfilter for high level radioactive service. The work has included upgrading the rotary microfilter for radioactive service, testing with simulated SRS waste streams, and testing it with simulated Hanford waste streams. While the filtration rate is better than that obtained during testing of crossflow filters, the authors believe the rotary microfilter throughput can be improved by using a better filter membrane. The rotary microfilter membrane is made of stainless steel (Pall PMM050). Previous testing, funded by DOE EM-21, showed that asymmetric filters composed of a ceramic membrane on top of a stainless steel support produced higher filter flux than 100% stainless steel symmetric filters in crossflow filter tests. In that testing, the Pall Accusep and Graver filters produced 13-21% larger filter flux than the baseline 0.1 {micro}m Mott filter. While the improvement in flux is not as dramatic as the improvement of the rotary filter over a crossflow filter, a 13-21% increase could reduce the lifetime of a 30 year process by 4-6 years, with significant cost savings. Subsequent rotary filter testing showed the Pall PMM050 stainless steel filter membrane produced higher flux than the Mott filter media in bench-scale and pilot-scale testing. The Accusep and Graver filter media were not evaluated in that testing, because they are not available as flat sheets. The Accusep filter was developed at ORNL and licensed to Pall Corporation. This filter has a stainless steel support structure with a zirconium oxide ceramic membrane. The pore size is 0.1 {micro}m absolute. The Graver filter has a stainless steel support structure with a titanium dioxide ceramic membrane. The pore size is 0.07 {micro}m absolute. SRNL and ORNL are working together to develop filter media similar to the Accusep and Graver media, and to test them in a bench-scale filtration apparatus to attempt to improve the throughput of the rotary microfilter. This report describes the effort.

36 MATERIALS SCIENCE↗

Chemical cleaning of porous stainless steel cross-flow filter elements for nuclear waste applications

The Waste Treatment and Immobilization Plant (WTP) currently under construction for treatment of High-Level Waste (HLW) at the Hanford Site will rely on cross-flow ultrafiltration to provide solids-liquid separation as a core part of the treatment process. To optimize process throughput, periodic chemical cleaning of the porous stainless steel filter elements has been incorporated into the design of the plant. It is currently specified that chemical cleaning with nitric acid will occur after significant irreversible membrane fouling is observed. Irreversible fouling is defined as fouling that cannot be removed by backpulsing the filter. PNNL has investigated chemical cleaning processes as part of integrated tests with HLW simulants and with actual Hanford tank wastes. To quantify the effectiveness of chemical cleaning, the residual membrane resistance after cleaning was compared against the initial membrane resistance for each test in a series of long-term fouling tests. The impact of the small amount of residual resistance in these tests could not be separated from other parameters and the historical benchmark of >1 GPM/ft2 for clean water flux was determined to be an adequate metric for chemical cleaning. Using the results from these tests, a process optimization strategy is presented suggesting that for the simulant material under test, the value of chemical cleaning may be suspect. The period of enhanced filtration may not be enough to offset the down time required for chemical cleaning, without respect to the other associated costs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Solids Performance Testing in a Scaled TSCR System

The Tank Side Cesium Removal (TSCR) project is a technology demonstration that will pretreat Hanford tank waste supernatant in support of the Direct Feed Low-Activity Waste (DFLAW) mission. The TSCR system employs two key separation technologies: dead-end filtration (DEF) and ion exchange (IX) using crystalline silicotitanate (CST) media. DEF will be used to remove undissolved solids from tank waste to protect the functionality of the IX columns and the IX system will remove Cs-137 from tank waste. The separation technologies (DEF and IX) used in TSCR are technically mature and have also been successfully deployed at the Savannah River site in a similar facility known as the Tank Closure Cesium Removal (TCCR) system. While testing with simulants and real waste has been successfully performed under conditions expected during the initial operation of TSCR, test data is absent for assessing off normal high solids loading that may be in the TSCR waste feed. Normal TSCR treatment operations are expected to handle wastes with solids content on the order of 200 ppm, and off normal solids loading could be much larger than the nominal level. The testing program described in this report was conducted to understand the consequence of operating the TSCR system at elevated solids loadings up to the high-solids limit of 15,000 ppm [i.e., 1.5-wt%] identified in the TSCR design basis. Although the system is not required to make throughput above the nominal solids loading, the testing was intended to provide important information related to potential off normal operations. At off normal levels near the high-solids limit, there are potential implications for TSCR performance in the areas of throughput, DEF pressure drop, filter backflush frequency, and IX column pressure drop. In addition, intrusion of solids into the IX column was postulated to impact the Cs-137 loading behavior by promoting channeling or flow maldistribution in the column; since the magnitude of the postulated effect was unknown, assessing it was also of interest. The testing was performed using representative waste simulants and a prototypic, integrated TSCR system designed and assembled specifically to conduct the high solids performance assessment. Overall, the scaled TSCR testing demonstrated that full-scale unit operations can succeed in fulfilling their processing objectives in the presence of solids up to 3,000 ppm, but there are potential performance challenges to filtration operations at solids loadings as low as ~500 ppm. The severity of the challenge is likely to be dependent on the type and size distribution of solids, of which the current testing only examined a single type and size distribution. To provide some flexibility for future full-scale operations, the results of the testing suggest two possible risk reduction strategies that can be implemented without any changes in TSCR design or configuration. One option would be to enact an administrative limit on the solids loading to protect TSCR from feeds that are likely to require a high DEF swap frequency. Another option is to permit operation of the DEFs at differential pressures greater than 2 psid before swapping filters. The selection of a higher differential pressure target is not anticipated to adversely impact DEF backflushing efficacy and would reduce both swap frequency and the amount of waste sent to AP-108.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CROSSFLOW FILTRATION: EM-31, WP-2.3.6

In the interest of accelerating waste treatment processing, the DOE has funded studies to better understand filtration with the goal of improving filter fluxes in existing crossflow equipment. The Savannah River National Laboratory (SRNL) performed some of those studies, with a focus on start-up techniques, filter cake development, the application of filter aids (cake forming solid precoats), and body feeds (flux enhancing polymers). This paper discusses the progress of those filter studies. Crossflow filtration is a key process step in many operating and planned waste treatment facilities to separate undissolved solids from supernate solutions. This separation technology generally has the advantage of self-cleaning through the action of wall shear stress created by the flow of waste slurry through the filter tubes. However, the ability of filter wall self-cleaning depends on the slurry being filtered. Many of the alkaline radioactive wastes are extremely challenging to filtration, e.g., those containing compounds of aluminum and iron, which have particles whose size and morphology reduce permeability. Unfortunately, low filter flux can be a bottleneck in waste processing facilities such as the Savannah River Integrated Salt Disposition Process and the Hanford Waste Treatment Plant. Any improvement to the filtration rate would lead directly to increased throughput of the entire process. To date increased rates are generally realized by either increasing the crossflow filter feed flow rate, limited by pump capacity, or by increasing filter surface area, limited by space and increasing the required pump load. SRNL set up both dead-end and crossflow filter tests to better understand filter performance based on filter media structure, flow conditions, filter cleaning, and several different types of filter aids and body feeds. Using non-radioactive simulated wastes, both chemically and physically similar to the actual radioactive wastes, the authors performed several tests to evaluate methods to improve filter performance. With the proper use of filter flow conditions and filter enhancers, filter flow rates can be increased over rates currently realized today. Experiments that use non-radioactive simulants for actual waste always carry the inherent risk of not eliciting prototypic results; however, they will assist in focusing the scope needed to minimize radioactive testing and thus maximize safety. To that end this investigation has determined: (1) Waste simulant SB6 was found to be more challenging to filtration than a SRS Tank 8F simulant; (2) Higher solids concentration presents a greater challenge to filtration; (3) Filter cake is something that should be properly developed in initial filter operation; (4) Backpulsing is not necessary to maintain a good filter flux with salt wastes; (5) Scouring a filter without cleaning will lead to improved filter performance; (6) The presence of a filter cake can improve the solids separation by an order of magnitude as determined by turbidity; (7) A well developed cake with periodic scouring may allow a good filter flux to be maintained for long periods of time; and (8) Filtrate flux decline is reversible when the concentration of the filtering slurry drops and the filter is scoured.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Validation of Ultrafilter Performance Model Based on Systematic Simulant Evaluation

Because of limited availability of test data with actual Hanford tank waste samples, a method was developed to estimate expected filtration performance based on physical characterization data for the Hanford Tank Waste Treatment and Immobilization Plant. A test with simulated waste was analyzed to demonstrate that filtration of this class of waste is consistent with a concentration polarization model. Subsequently, filtration data from actual waste samples were analyzed to demonstrate that centrifuged solids concentrations provide a reasonable estimate of the limiting concentration for filtration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and Demonstration of Ultrafiltration Simulants

According to Bechtel National, Inc. (BNI) Test Specification 24590-PTF-TSP-RT-06-006, Rev 0, Simulant Development to Support the Development and Demonstration of Leaching and Ultrafiltration Pretreatment Processes,” simulants for boehmite, gibbsite, and filtration are to be developed that can be used in subsequent bench and integrated testing of the leaching/filtration processes for the waste treatment plant (WTP). These simulants will then be used to demonstrate the leaching process and to help refine processing conditions which may impact safety basis considerations (Smith 2006). This report documents the results of the filtration simulant development.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The DISTINCTIVE University Consortium: Legacy Ponds and Silo Wastes - 18135

The UK Engineering and Physical Sciences Research Council (EPSRC) sponsored DISTINCTIVE consortium (Decommissioning, Immobilisation and Storage Solutions for Nuclear Waste Inventories) is undertaking 22 science and engineering projects across 11 universities related to the decommissioning of the Legacy Ponds and Silos at Sellafield. These are grouped into three work packages that focus on wasteform durability, effluent treatment and pond and silo sludges. Specific challenges include understanding the durability of intermediate level waste (ILW) glass-ceramic waste forms, studying thermally treated Pu-containing materials, producing and testing new inorganic ion exchange materials including derivatized magnetic nanoparticles for Cs, Sr and U removal from effluent, developing micro- and ultra-filtration methods, providing improved modelling and simulation of sludge disturbance, mobilisation and transport, developing a better understanding of gas hold-up in sludges, exploring methods for sludge characterisation including the use of acoustic backscatter and quartz crystal microbalance techniques and Raman spectroscopy and computer modelling of the interaction of cations with brucite surfaces. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗