Search NASA⌕ Search

SEARCH · Search NASA

Results for “waste water”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Sequestration of CO{sub 2} in Mixtures of Caustic Byproduct and Saline Waste Water

A series of tests were conducted to investigate a novel reaction concept designed to achieve neutralization of mixtures of acidic oil field produced brine and caustic industrial byproducts while sequestering substantial quantities of anthropogenic carbon dioxide (CO{sub 2}) in a mixed-flow reactor. Experiments were conducted to determine the CO{sub 2}-bearing capacity of reactive mixtures of brine from the Oriskany Sandstone Formation with three caustic industrial byproducts: flue gas desulfurization (FGD) spray dryer ash, Class C fly ash subbituminous coal combustion byproduct, and bauxite residue slurry from the alumina production process. Reactions were conducted in a closed, well-mixed (1,500 rpm) reactor with gas composed of 29.46% vol./vol. CO{sub 2} balanced by nitrogen gas fed at a rate of 300 mL/min. Reactions were carried out at ambient conditions. Results show linear relationships between caustic byproduct addition and CO{sub 2}-bearing capacity, with relatively small impact of brine addition as compared to deionized water addition. FGD spray dryer ash/brine mixtures exhibited higher CO{sub 2} reactivity than those using Class C fly ash (0.759 moles CO{sub 2}, at 23.6% solids by weight and 0.036 moles CO{sub 2} at 23.3% solids by weight, respectively). Bauxite residue exhibited moderate capacities in mixtures with higher percent solids (0.335 moles CO{sub 2} in 40% solids bauxite residue slurry). Carbonation capacity of caustic byproduct/acidic brine mixtures was shown to increase linearly with respect to percent caustic byproduct addition, but enhanced mineral carbonate precipitation resulting from synergistic reaction of brine cations with increased dissolved carbonate species was not observed in the short term.

01 COAL, LIGNITE, AND PEAT↗

Lessons Learned for Construction and Waste Water Management at Radioactive Waste Closure Site

Environmental remediation of three different radioactive waste closure sites each required exhaustive characterization and evaluation of sampling and analytical information in resolving regulatory and technical issues that impact cleanup activities. One of the many regulatory and technical issues shared by all three and impacting the cleanup activities is the compliant management and discharge of waste waters generated and resulting from the remediation activities. Multiple options were available for each closure site in resolving waste water management challenges depending upon the base regulatory framework defined for the cleanup or closure of the site. These options are typically regulated by the federal Clean Water Act (CWA), with exemptions available under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) and the Superfund Amendments and Reauthorization Act of 1986 (SARA) or Memorandum of Understanding (MOU) between regulatory agencies. In general, all parties must demonstrate equivalent compliance when concerns related to the protection of the general public and the environment. As such, all options for management of waste water resulting from closure activities must demonstrate compliance to or equivalent actions under the CWA. The CWA provides for the National Pollution Discharge Elimination System (NPDES) that is typically maintained by individual states through permitting process to generators, public utilities, and more recently, construction sites. Of the three sites, different compliance strategies were employed for each. The approach for the Columbus Closure Project (CCP) was to initiate full scale compliance to the Ohio EPA General Construction Permit No. OHC000002. The CCP provided Notice of Intent (NOI) to the Ohio EPA to discharge under the general permit according to the regulator approved Storm Water Pollution Prevention Plan. For the second site, the Li Tungsten Superfund Site in Glen Cove, New York, the option was to manage and discharge waste water under a due diligence process to New York State General Permit No. GP-02-01. For the third site, the Middlesex Sampling Plant in Middlesex, New Jersey, the options was to manage and discharge waste water to the Publicly Owned Treatment Works (POTW). Each option has resulted in a safe, cost-effective, and compliant approach to managing discharging waste waters from the site closure activities. (authors)

54 ENVIRONMENTAL SCIENCES↗

Remaining Sites Verification Package for the 100-F-26:15 Miscellaneous Pipelines Associated with the 132-F-6, 1608-F Waste Water Pumping Station, Waste Site Reclassification Form 2007-031

The 100-F-26:15 waste site consisted of the remnant portions of underground process effluent and floor drain pipelines that originated at the 105-F Reactor. In accordance with this evaluation, the verification sampling results support a reclassification of this site to Interim Closed Out. The results of verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

100-F-26:15 Miscellaneous Pipelines↗

Removal of Radionuclides from Waste Water at Fukushima Daiichi Nuclear Power Plant: Desalination and Adsorption Methods - 13126

Waste water containing high levels of radionuclides due to the Fukushima Daiichi Nuclear Power Plant accident, has been treated by the adsorption removal and reverse-osmosis (RO) desalination to allow water re-use for cooling the reactors. Radionuclides in the waste water are collected in the adsorbent medium and the RO concentrate (RO brine) in the water treatment system currently operated at the Fukushima Daiichi site. In this paper, we have studied the behavior of radionuclides in the presently applied RO desalination system and the removal of radionuclides in possible additional adsorption systems for the Fukushima Daiichi waste water treatment. Regarding the RO desalination system, decontamination factors (DFs) of the elements present in the waste water were obtained by lab-scale testing using an RO unit and simulated waste water with non-radioactive elements. The results of the lab-scale testing using representative elements showed that the DF for each element depended on its hydrated ionic radius: the larger the hydrated ionic radius of the element, the higher its DF is. Thus, the DF of each element in the waste water could be estimated based on its hydrated ionic radius. For the adsorption system to remove radionuclides more effectively, we studied adsorption behavior of typical elements, such as radioactive cesium and strontium, by various kinds of adsorbents using batch and column testing. We used batch testing to measure distribution coefficients (K{sub d}s) for cesium and strontium onto adsorbents under different brine concentrations that simulated waste water conditions at the Fukushima Daiichi site. For cesium adsorbents, K{sub d}s with different dependency on the brine concentration were observed based on the mechanism of cesium adsorption. As for strontium, K{sub d}s decreased as the brine concentration increased for any adsorbents which adsorbed strontium by intercalation and by ion exchange. The adsorbent titanium oxide had higher K{sub d}s and it was used for the column testing to obtain breakthrough curves under various conditions of pH and brine concentration. The breakthrough point had a dependency on pH and the brine concentration. We found that when the pH was higher or the brine concentration was lower, the longer it took to reach the breakthrough point. The inhibition of strontium adsorption by alkali earth metals would be diminished for conditions of higher pH and lower brine concentration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of the Ability to Measure Traces of Water in Dehydrated Residues of Waste Water by IR Diffuse Reflectance Spectra

Rapid measurement of the moisture content of dehydrated residues is a critical problem, the solution of which will increase the efficiency of treatment facilities and optimize the process of applying flocculants. The ability to determine the moisture content of dehydrated residues using a meter operating on the IR reflectance principle was confirmed experimentally. The most suitable interference filters were selected based on an analysis of the obtained diffuse reflectance spectrum of the dehydrated residue in the range 1.0–2.7 μm. Calibration curves were constructed and compared for each filter set. A measuring filter with a transmittance maximum at 1.19 μm and a reference filter with a maximum at 1.3 μm gave the best agreement with the laboratory measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Treatment of Radioactive Sludge From Waste Water Treatment for Weight and Volume Reduction with FreezeTec-Technique - 17010

At the Studsvik site in Sweden, Studsvik Nuclear AB operates a water treatment facility that treat all the waste water from the nuclear facilities at the site. The facility contains several pools for waste water treatment. The standard procedure for treating the water consist of adding FeCl{sub 3} to precipitate any particulates. Historically this waste has been mixed with concrete and grouted into barrels which will increase the volume needed for disposal in final repository. The sludge that is generated from the water treatment facility has been subject to treatment with the Freeze-Tec method where the sludge is freeze dewatered and after thawing generating a solid phase with high dry substance and a clear water phase. The radioactive particles/nuclides tend to stay in the solid phase while the water phase has very low concentration of radioactive particles. 99.9% of the Co-60 and Cs-137 activity end up in the solids and a dry solid with smaller volume and weight is obtained after treatment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hygroscopic cooling tower for waste water disposal

In various embodiments, the present invention relates to heat dissipation systems including a hygroscopic working fluid integrating waste water as makeup water. The present invention also relates to methods of using the same. The present invention also relates to hygroscopic cooling systems adapted to dispose of waste water by combining the waste water with a hygroscopic working fluid, precipitating impurities and evaporating the remaining water.

Martin, Christopher Lee↗

Hygroscopic cooling tower for waste water disposal

In various embodiments, the present invention relates to heat dissipation systems including a hygroscopic working fluid integrating waste water as makeup water. The present invention also relates to methods of using the same. The present invention also relates to hygroscopic cooling systems adapted to dispose of waste water by combining the waste water with a hygroscopic working fluid, precipitating impurities and evaporating the remaining water.

Martin, Christopher Lee↗

Decontamination of Nuclear Liquid Wastes Status of CEA and AREVA R and D: Application to Fukushima Waste Waters - 12312

Liquid wastes decontamination processes are mainly based on two techniques: Bulk processes and the so called Cartridges processes. The first technique has been developed for the French nuclear fuel reprocessing industry since the 60's in Marcoule and La Hague. It is a proven and mature technology which has been successfully and quickly implemented by AREVA at Fukushima site for the processing of contaminated waters. The second technique, involving cartridges processes, offers new opportunities for the use of innovative adsorbents. The AREVA process developed for Fukushima and some results obtained on site will be presented as well as laboratory scale results obtained in CEA laboratories. Examples of new adsorbents development for liquid wastes decontamination are also given. A chemical process unit based on co-precipitation technique has been successfully and quickly implemented by AREVA at Fukushima site for the processing of contaminated waters. The asset of this technique is its ability to process large volumes in a continuous mode. Several chemical products can be used to address specific radioelements such as: Cs, Sr, Ru. Its drawback is the production of sludge (about 1% in volume of initial liquid volume). CEA developed strategies to model the co-precipitation phenomena in order to firstly minimize the quantity of added chemical reactants and secondly, minimize the size of co-precipitation units. We are on the way to design compact units that could be mobilized very quickly and efficiently in case of an accidental situation. Addressing the problem of sludge conditioning, cementation appears to be a very attractive solution. Fukushima accident has focused attention on optimizations that should be taken into account in future studies: - To better take account for non-typical aqueous matrixes like seawater; - To enlarge the spectrum of radioelements that can be efficiently processed and especially short lives radioelements that are usually less present in standard effluents resulting from nuclear activities; - To develop reversible solid adsorbents for cartridge-type applications in order to minimize wastes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Subdrain Water Treatment Facility for Reduction of Waste Water Amount at the Fukushima NPS Site - 19318

At the Fukushima Daiichi Nuclear Power Station site, a water treatment facility dedicated to the subdrain and groundwater drain has been constructed by Tokyo Electric Power Company Holdings, Inc. and Hitachi-GE Nuclear Energy, Ltd. The facility consists of three kinds of equipment for collecting, purifying and transferring contaminated water. The purification equipment removes low concentration radionuclides, such as Cs-137 and Sr-90, contained in the pumped groundwater using adsorption vessels filled with Cs-Sr adsorbent. It is important to lower the operational cost of the facility. We have been developing a cost reduction technique to prolong the operating lifetime of the Cs-Sr adsorption vessels by improving the adsorption performance of the Cs-Sr simultaneous adsorbent. Therefore, pH adjustment for the groundwater by using granular MgO as a pH adjustment agent was investigated. The experimental and the simulation results showed that the distribution coefficient Kd with pH adjustment by MgO was evaluated as approximately 1.8 times higher than Kd without pH adjustment and the replacement timing of the Cs-Sr adsorption vessels with pH adjustment was 2 times longer than the timing without pH adjustment. From these results, we decided to include pH adjustment using MgO as the pH adjustment agent in the purification equipment in order to reduce the amount of Cs-Sr simultaneous adsorbent used and the operational cost of the facility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sub-drain Water Treatment Facility for Reduction of Accumulated Waste Water Amount at the Fukushima NPS Site - 17572

At the Fukushima Daiichi Nuclear Power Station site, water treatment facility special for sub-drain and groundwater drain has been constructed by Tokyo Electric Power Company Holdings, Inc. and Hitachi-GE Nuclear Energy, Ltd., and it has been operated to remove radionuclides from the pumped groundwater. The facility consists of three kinds of equipment for collecting, purifying and transferring. The purification equipment removes radionuclides contained in the pumped groundwater. The purification equipment consists of filters for removal of solids and colloidal particles, and adsorbents for removal of ionic radionuclides. Five adsorption vessels are installed into the equipment; three vessels have adsorbent to remove Cs and Sr simultaneously, the fourth vessel has adsorbent to remove Sb and for the last has adsorbent to remove heavy metals. The vessels for Cs and Sr are operating as a so-called 'merry-go-round'. For the rational operation of the equipment, a simulation code has been developed to calculate the Sr concentration of outlet water which determines the replacement timings of the Cs-Sr adsorption vessels. The simulation code has been applied to planning of vessel replacement during the water treatment facility operation. The facility started operation in September 2015, and treated the pumped groundwater since then. As of October 2016, about 211,000 m{sup 3} of groundwater had been treated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Forward Osmosis-based System for Treatment of Waste Water Generated During Energy Production Using Waste Carbon Dioxide and Waste Heat

For this project, we performed initial studies investigating the feasibility of a system that would capture carbon dioxide from post-combustion flue gas and use the CO 2 to drive the treatment of wastewater. Our system can remove carbon dioxide for storage (as pure CO 2 ) using low-grade waste heat from the power plant to power the process. As an additional benefit, our system can provide clean water for reuse in the plant where the purification process is driven by carbon dioxide. The COHO (CO 2 -H 2 O) system uses a breakthrough forward osmosis membrane developed by Porifera in combination with a recyclable draw solvent developed by Idaho National Laboratory to efficiently treat wastewater and consume carbon dioxide. With this research, we determined that COHO is able to capture up to 75% of a power plant’s CO 2 emissions if supplying and treating the boiler water feed. The installation of COHO at a power plant will (1) reduce wastewater volumes, (2) reduce the energy costs to treat wastewater, (3) expand the capabilities of water treatment all while (4) reducing the cost of carbon capture from flue gas.

20 FOSSIL-FUELED POWER PLANTS↗

Forward Osmosis-based System for Treatment of Waste Water Generated During Energy Production Using Waste Carbon Dioxide and Waste Heat. Final Report

The installation of COHO at a power plant will reduce the volume of wastewater, reduce the energy costs to treat wastewater, expand the capabilities of water treatment all while reducing the cost of carbon capture from flue gas. In Phase IIB studies, Porifera explored the use of a next-generation COHO system to synergistically capture carbon dioxide from flue gas and treat wastewater at power plants. We found that the next generation system benefits from improved operational efficiency and safety. In addition, we performed a technoeconomic analysis of the system and found it to save significant cost compared to conventional technologies.

20 FOSSIL-FUELED POWER PLANTS↗

Synthesis of β-Cyclodextrin Immobilized Starch and Its Application for the Removal of Dyestuff from Waste-Water

A natural polymeric adsorbent, β-cyclodextrin immobilized starch (CS-βCD) was prepared by introducing host functional molecule β-cyclodextrin (β-CD) onto starch in presence of citric acid. The immobilization conditions were optimized to: m CA:m CS = 1:2, reaction time of 2 h and reaction temperature at 120 °C, by varying the input levels of the reactant, CS-βCD with a series of immobilization ratio (IR) and carboxyl content (CC) could be obtained. The FT-IR and {sup 13}C-NMR analysis indicated the β-CD molecules have been immobilized onto starch via the formation of ester linkages. The XRD and SEM analysis showed CS-βCD had more looser structure and more irregular surface compared with native starch. The GPC analysis showed CS-βCD had a reduced molecular weight but a more complicated molecular configuration. The adsorbing capacities of CS-βCD to three cationic dyes (methylene blue, methyl purple and basic fuchsin) were significantly improved compared with native starch, diatomite and zeolite. The adsorption behaviors of CS-βCD to the three dyes had high fitting degrees to both Langmuir and Freundlich models (R{sup 2} > 0.98). The decolourization ratio of CS-βCD to the mixed dyestuff waste-water had reached 88.75%, which was much higher than other absorbents. The results indicated the CS-βCD would become a high-efficiency dyestuff adsorbent, and would have a promising application in the industrial dyestuff waste-water treatment.

36 MATERIALS SCIENCE↗

A Novel Hyperbranched Polymeric Flocculant for Waste-Water Treatment

Cationic hyperbranched oligomer poly(N-acryloyl-1,2-diaminoethane hydrochloride) (HADE) was firstly synthesized by Michael addition reaction. And then, a series of cationic flocculants poly(acrylamide/N-acryloyl-1,2-diaminoethane hydrochlorides) (PAM-HADEs) with hyperbranched structure was prepared from HADE as macro-monomer and acrylamide (AM). The structures of PAM-HADEs were characterized by Fourier transform infrared spectrometry, {sup 1}H and {sup 13}C nuclear magnetic resonance spectroscopy, gel permeation chromatography (GPC) and matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF). And the properties were systematically evaluated by intrinsic viscosity, zeta potential and hydrodynamic radius. The mechanism of the cationic hyperbranched copolymer used in water treatment was extensively studied via a jar test in which the transmittance of the supernatant, settling time, and average floc size were used to evaluate the flocculability. Compared with the linear flocculant poly (acrylamide/liner-N-acryloyl-1,2-diaminoethane hydrochloride) (PAM-LADE), the novel hyperbranched polymeric flocculants exhibited outstanding flocculability which were reflected by shorter settlement time, high transmittance and large floc size. The primary cause that PAM-HADEs owned excellent flocculability is the more stretching configuration and less chains entanglement of PAM-HADEs in waste-water due to their hyperbranched structure compared with that of the linear PAM-LADE which exhibited curly coil configuration. On the other hand, abundant and exposed cationic terminal groups of PAM-HADEs originated from their hyperbranched structure also hint higher flocculation capacity. At optimum dosages of the polymer, the transmittance of the supernatant is less at low and high pH values, indicating that the natural pH (pH 7.29) of the suspension is the most appropriate pH for the flocculation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Removing Dissolved Silica from Waste Water with Catechol and Active Carbon

Fresh water scarcity is going to be a global great challenge in the near future because of the increasing population. Our water resources are limited and, hence, water treatment and recycling methods are the only alternatives for fresh water procurement in the upcoming decades. Water treatment and recycling methods serve to remove harmful or problematic constituents from ground, surface and waste waters prior to its consumption, industrial supply, or other uses. Scale formation in industrial and domestic installations is still an important problem during water treatment. In water treatment, silica scaling is a real and constant concern for plant operations. The focus of this study is on the viability of using a combination of catechol and active carbon to remove dissolved silica from concentrated cooling tower water (CCTW). Various analytical methods, such as ICP-MS and UV-vis, were used to understand the structure-property relationship between the material and the silica removal results. UV-Vis indicates that catechol can react with silica ions and form a silica-catecholate complex. The speciation calculation of catechol and silica shows that catechol and silica bind in the pH range of 8 – 10; there is no evidence of linkage between them in neutral and acidic pHs. The silica removal results indicate that using ~4g/L of catechol and 10g/L active carbon removes up to 50% of the dissolved silica from the CCTW.

54 ENVIRONMENTAL SCIENCES↗