Search NASA⌕ Search

SEARCH · Search NASA

Results for “water diffusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Water diffusion in a basaltic melt

Measurements of water diffusivity in a basaltic liquid are reported. The concentration-dependent total water diffusivities in the basaltic melt at 1300-1500 C are 30-50 times as large as those in rhyolitic melts and are greater than the total CO2 diffusivity in basaltic melts, contrary to previous expectations. These results suggest that diffusive fractionation would increase the ratio of water to CO2 in growing bubbles relative to equilibrium partitioning and decrease the ratio in interface melts near an advancing anhydrous phenocryst.

Zhang, Youxue↗

Development of an improved membrane for a vapor diffusion water recovery process

Recovery of potable water from urine on manned space missions of extended duration was the objective of work aimed at the improvement of membrane performance for the vapor diffusion process (VDR). Kynar, Teflon, PVC, and polysulfone candidate membranes were evaluated from chemical, thermal, mechanical, and fabricating standpoints to determine their suitability for operation in the VDR pervaporation module. Pervaporation rates and other performance characteristics were determined in a breadboard pervaporator test rig. Kynar and Teflon membranes were demonstrated to be chemically stable at pervaporation temperatures in urine pretreated with chromic acid bactericide. The separation of the pervaporator and condenser modules, the use of a recirculating sweep gas to conduct pervaporate to the condenser, and the selection of a hollow fiber membrane configuration for pervaporator module design is recommended as a result of the investigation.

Rich, T. R.↗

Water diffusion membranes 3 (pervaporation and heat rejection through composite membranes)

The problem of waste management in space is discussed for manned space flight. It is shown that such waste can be accounted for in one of four ways: (1) the waste may be dumped into space; (2) it may be accumulated for return to earth; (3) the waste may be separated into two fractions, one fraction (water) to be dumped into space and the remaining portion to be returned to earth; or (4) the waste components may be beneficially reused.

Cabasso, I.↗

Diffusion of water in rhyolitic glasses

The process of water diffusion in 11 natural rhyolitic glasses was considered using the results of measurements by FTIR spectroscopy of concentration profiles of both H2O and OH at different temperatures. The diffusion coefficients of H2O and OH, D(H2O) and D(OH), respectively, were calculated from concentration profiles. Results indicate that, at 400-530 C, the value of D(OH) is negligible compared to that of D(H2O), and that OH does not contribute significantly to the diffusion of total water even at water concentrations as low as 0.2 percent, which is minute compared to that of OH. In the activation energy vs radius plot, the D(H2O) followed the same trend as that of noble gases.

Zhang, Youxue↗

Water vapor diffusion membranes

The program is reported, which was designed to define the membrane technology of the vapor diffusion water recovery process and to test this technology using commercially available or experimental membranes. One membrane was selected, on the basis of the defined technology, and was subjected to a 30-day demonstration trial.

Holland, F. F., Jr.↗

Water vapor diffusion membrane development

A total of 18 different membranes were procured, characterized, and tested in a modified bench-scale vapor diffusion water reclamation unit. Four membranes were selected for further studies involving membrane fouling. Emphasis was placed on the problem of flux decline due to membrane fouling. This is discussed in greater details under "Summary and Discussion on Membrane Fouling Studies" presented in pages 47-51. The system was also investigated for low temperature application on wash-water where the permeated water is not recovered but vented into space vacuum.

Tan, M. K.↗

Water vapor diffusion membrane development

An application of the water vapor diffusion technique is examined whereby the permeated water vapor is vented to space vacuum to alleviate on-board waste storage and provide supplemental cooling. The work reported herein deals primarily with the vapor diffusion-heat rejection (VD-HR) as it applies to the Space Shuttle. A stack configuration was selected, designed and fabricated. An asymmetric cellulose acetate membrane, used in reverse osmosis application was selected and a special spacer was designed to enhance mixing and promote mass transfer. A skid-mount unit was assembled from components used in the bench unit although no attempt was made to render it flight-suitable. The operating conditions of the VD-HR were examined and defined and a 60-day continuous test was carried out. The membranes performed very well throughout the test; no membrane rupture and no unusual flux decay was observed. In addition, a tentative design for a flight-suitable VD-HR unit was made.

Tan, M. K.↗

Water vapor diffusion membranes, 2

Transport mechanisms were investigated for the three different types of water vapor diffusion membranes. Membranes representing porous wetting and porous nonwetting structures as well as dense diffusive membrane structures were investigated for water permeation rate as a function of: (1) temperature, (2) solids composition in solution, and (3) such hydrodynamic parameters as sweep gas flow rate, solution flow rate and cell geometry. These properties were measured using nitrogen sweep gas to collect the effluent. In addition, the chemical stability to chromic acid-stabilized urine was measured for several of each type of membrane. A technology based on the mechanism of vapor transport was developed, whereby the vapor diffusion rates and relative susceptibility of membranes to fouling and failure could be projected for long-term vapor recovery trials using natural chromic acid-stabilized urine.

Holland, F. F.↗

Experimental dehydration of natural obsidian and estimation of DH2O at low water contents

Water diffusion experiments were carried out by dehydrating rhyolitic obsidian from Valles Caldera (New Mexico, USA) at 510-980 degrees C. The starting glass wafers contained approximately 0.114 wt% total water, lower than any glasses previously investigated for water diffusion. Weight loss due to dehydration was measured as a function of experiment duration, which permits determination of mean bulk water diffusivity, mean Dw. These diffusivities are in the range of 2.6 to 18 X 10(-14) m2/s and can be fit with the following Arrhenius equation: ln mean Dw (m2/s) = -(25.10 +/- 1.29) - (46,480 +/- 11,400) (J/mol) / RT, except for two replicate runs at 510 degrees C which give mean Dw values much lower than that defined by the above equation. When interpreted according to a model of water speciation in which molecular H2O is the diffusing species with concentration-independent diffusivity while OH units do not contribute to the transport but react to provide H2O, the data (except for the 510 degrees C data) are in agreement with extrapolation from previous results and hence extend the previous data base and provide a test of the applicability of the model to very low water contents. Mean bulk water diffusivities are about two orders of magnitude less than molecular H2O diffusivities because the fraction of molecular H2O out of total water is very small at 0.114 wt% total water and less. The 510 degrees C experimental results can be interpreted as due to slow kinetics of OH to H2O interconversion at low temperatures.

NASA Program Exobiology↗

Rapid formation of Jupiter by diffuse redistribution of water vapor in the solar nebula

In the present, water-vapor diffusive redistribution and condensation model of solid material abundance enhancement in the solar nebula's Jupiter-formation region, the assumed turbulent nebula temperatures decrease inversely with radial distance from the center, and time-scales are set by turbulent viscosities. The length scale for condensation of diffusively-transported water vapor is about 0.4 AU, and the surface density of ice in the Jupiter-formation zone undergoes enhancement by a factor of as much as 75; this surface density enhancement is enough to precipitate the rapid accretion of planetesimals into a solid core.

Stevenson, David J.↗

New explicit equations for the accurate calculation of the growth and evaporation of hydrometeors by the diffusion of water vapor

The traditional explicit growth equation has been widely used to calculate the growth and evaporation of hydrometeors by the diffusion of water vapor. This paper reexamines the assumptions underlying the traditional equation and shows that large errors (10-30 percent in some cases) result if it is used carelessly. More accurate explicit equations are derived by approximating the saturation vapor-density difference as a quadratic rather than a linear function of the temperature difference between the particle and ambient air. These new equations, which reduce the error to less than a few percent, merit inclusion in a broad range of atmospheric models.

Srivastava, R. C.↗

Water vapor diffusion membrane development

The phase separator component used as a membrane in the vapor diffusion process (VRD) for the recovery of potable water from urine on manned space missions of extended duration was investigated, with particular emphasis on cation-selective membranes because of their noted mechanical strength, superior resistance to acids, oxidants, and germicides, and their potential resistance to organic foulants. Two of the membranes were tested for 700 hours continuously, and were selected on the basis of criteria deemed important to an effective water reclamation system onboard spacecraft. The samples of urine were successfully processed by removing 93 percent of their water content in 70 hours using the selected membranes. Pretreatment with an acid-oxidant formulation improved product quality. Cation exchange membranes were shown to possess superior mechanical strength and chemical resistance, as compared to cellulosic membranes.

Tan, M. K.↗

A practical method of determining water current velocities and diffusion coefficients in coastal waters by remote sensing techniques

A simplified procedure is presented for determining water current velocities and diffusion coefficients. Dye drops which form dye patches in the receiving water are made from an aircraft. The changes in position and size of the patches are recorded from two flights over the area. The simplified data processing procedure requires only that the ground coordinates about the dye patches be determined at the time of each flight. With an automatic recording coordinatograph for measuring coordinates and a computer for processing the data, this technique provides a practical method of determining circulation patterns and mixing characteristics of large aquatic systems. This information is useful in assessing the environmental impact of waste water discharges and for industrial plant siting.

James, W. P.↗

Hydrogen Peroxide Concentrator

A relatively simple and economical process and apparatus for concentrating hydrogen peroxide from aqueous solution at the point of use have been invented. The heart of the apparatus is a vessel comprising an outer shell containing tubular membranes made of a polymer that is significantly more permeable by water than by hydrogen peroxide. The aqueous solution of hydrogen peroxide to be concentrated is fed through the interstitial spaces between the tubular membranes. An initially dry sweep gas is pumped through the interiors of the tubular membranes. Water diffuses through the membranes and is carried away as water vapor mixed into the sweep gas. Because of the removal of water, the hydrogen peroxide solution flowing from the vessel at the outlet end is more concentrated than that fed into the vessel at the inlet end. The sweep gas can be air, nitrogen, or any other gas that can be conveniently supplied in dry form and does not react chemically with hydrogen peroxide.

Parrish, Clyde F.↗

Designing a Decontamination Solution for the Low-Earth-Orbit, Cryogenic SPHEREx Mission

To address the scientific goals of NASA’s astrophysics division, the JPL and Caltech’s SPHEREx mission conducts the first near-infrared all-sky spectral survey in low-earth-orbit using a passively-cooled, cryogenic telescope. Several unique water contamination issues arise due to the combination of cryogenic operation temperatures and the limited temperature control authority of passive cooling. Because water molecules have adsorption bands within the wavelengths of interest for SPHEREx’s survey, it is imperative that water contamination be controlled and minimized. In this work, a model is developed for the SPHEREx mission to predict the transport and accumulation of outgassed water onto sensitive payload components. The model utilizes the time dependent thermal profiles of the individual payload components, initial water content, and spacecraft geometry to calculate the time dependent water diffusion, transport, and adsorption. This model is subsequently used to predict water contamination risks and design decontamination solutions for each risk. Two major water contamination risks were predicted, water accumulation during cooldown and on cryogenic surfaces during the mission. The first risk occurs during the cooldown of the payload to cryogenic temperatures, predicting water accumulation on optical surfaces in excess of the allowable levels. To mitigate this accumulation, the temperature of the optical surfaces is controlled during cooldown through a combination of heaters and spacecraft pointing. The second risk is that over the course of the mission, is unavoidable water accumulation onto the payload thermal system’s cryogenic surfaces, possibly jeopardizing thermal performance and temperature stability, both of which are required for science success. To decontaminate any water that had collected onto cryogenic thermal system surfaces, a decontamination maneuver was designed. In this decontamination maneuver, cryogenic surfaces of the thermal system are warmed to a temperature where water will desorb by spacecraft pointing while still meeting all avoidance constraints, and thereby avoiding undue risk to the observatory hardware. Through application of the developed analytical model and inclusion of the decontamination maneuver in the mission design, SPHEREx can confidently demonstrate that it is able to decontaminate, at the start of and during the mission as needed to meet its end of life science performance requirements.

Soares, Carolos E.↗