Search NASA⌕ Search

SEARCH · Search NASA

Results for “water evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluating Water Reactivity at Silica Surfaces Using Reactive Potentials

Understanding the interactions between amorphous silica surfaces and water provides insight into material degradation of silicate glasses and minerals in aqueous environment. Molecular dynamics (MD) simulations of water and nanometer sized silica structures were used in this work to evaluate the reactivity of flat silica surface and surfaces with curvature. We compared two dissociable water/silica potentials, namely the Reactive Force Field (ReaxFF) and the Mahadevan–Garofalini water/silica force field (MGFF) that have been in development over the past decade, to study their performance in simulating bulk water as well as silica–water interactions. Significant differences in the properties of bulk water as well as surface interactions were observed between the two types of potentials, as well in the same potential type with two parametrizations for ReaxFF, suggesting a need for improvement of the existing water/silica ReaxFF potentials. Our simulation results show that a majority of the silanols were formed by reactions between water and strained siloxane bonds that mainly exist on the surface of amorphous silica, within a few nanoseconds of the simulation time scale, in agreement with previous studies. Effect of surface curvature on the reactivity with water was investigated. Our results indicate that defect concentration at the surface bears a strong correlation to the concentration of silanols (Si–OH) that eventually form. We observe undercoordinated Si’s at the surface that are attacked by water before the hydrolysis reaction of the siloxane bonds and demonstrate possible mechanisms of water reacting with these undercoordinated Si’s. Furthermore, we also find that the method of generating surfaces in simulation determines the defect concentration and hence influences the reactivity of the amorphous silica surface.

36 MATERIALS SCIENCE↗

Evaluating Water Assets Using Water Efficiency Framework for Infrastructure Intensive Agency

Water infrastructure-intensive organizations should incorporate sustainability principles when making decisions on infrastructure investments to ensure the long-term resilience of mission-critical equipment and components. A water efficiency evaluation framework to inform infrastructure investments is discussed and applied to three federal campuses. The methodology considered emphasizes the iterative process between data analysis and decision-making; evaluates cost-sharing solution alternatives when making final recommendations; considers both internal and external stakeholder perceptions of project outcomes and future planning; and makes explicit government and community preferences when evaluating projects. Case study findings underscore condition evaluations for infrastructure that are critical to setting a baseline for system performance and determining desired potential upgrades and sustainment strategies. Such a holistic approach has demonstrated effectiveness for understanding, classifying, and recommending innovative water asset solutions that are necessary for the public sector to consider in today’s complex, modern planning environment.

Asset Management, Alternative Water, evaluation, P↗

Handbook: Water Evaluation Tools

This document provides general instructions on performing a walk-through water survey to collect the required data for a comprehensive water evaluation and entering data into the online Water Balance Tool.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using Metered Data for Energy and Water Evaluations

This reference document explains the legislative basis for comprehensive energy and water evaluations, describes the steps of the typical evaluation process, and connects evaluation steps to graphical analysis techniques and common evaluation questions. The intended audience for this reference document is energy managers and others who are new to using metered data to support evaluations and have limited experience with metered data analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lessons Learned from Comprehensive Energy and Water Evaluations at U.S. Army Campus Installations

The U.S. Department of Energy’s Pacific Northwest National Laboratory has engaged in a multi-year collaboration with the U.S. Army to support comprehensive energy and water evaluations at large Army campus installations. Initiated to help the Army achieve compliance with facility evaluation requirements dictated by the Energy Independence and Security Act of 2007, this effort has resulted in the evaluation of 530 buildings at 14 installations across the U.S., and the identification of annual savings potential of over 212 billion Btu of energy and 29 million gallons of water. This paper highlights the nature of the evaluation process applied at these Army installations and discusses a number of key findings that can be considered for ongoing and future evaluations at Army and other federal agency facilities, particularly those buildings within campus settings.

Woodward, James C.↗

Perched-Water Evaluation for the Deep Vadose Zone Beneath the B, BX, and BY Tank Farms Area of the Hanford Site

Perched-water conditions have been observed in the vadose zone above a fine-grained zone that is located a few meters above the water table within the B, BX, and BY Tank Farms area. The perched water contains elevated concentrations of uranium and technetium-99. This perched-water zone is important to consider in evaluating the future flux of contaminated water into the groundwater. The study described in this report was conducted to examine the perched-water conditions and quantitatively evaluate 1) factors that control perching behavior, 2) contaminant flux toward groundwater, and 3) associated groundwater impact.

flux↗

Accounting for uncertainty in evaluating water quality impacts of urban development plan

The implementation of urban development plans causes land use change, which can have significant environmental impacts. In light of this, environmental concerns should be considered sufficiently at an early stage of the planning process. However, uncertainties existing in urban development plans hamper the application of strategic environmental assessment, which is applied to evaluate the environmental impacts of policies, plans and programs. This study develops an integrated assessment method based on accounting uncertainty of environmental impacts. And the proposed method consists of four main steps: (1) designing scenarios of economic scale and industrial structure, (2) sampling for possible land use layouts, (3) evaluating each sample's environmental impact, and (4) identifying environmentally sensitive industries. In doing so, uncertainties of environmental impacts can be accounted. Then environmental risk, overall environmental pressure and potential extreme environmental impact of urban development plans can be analyzed, and environmentally sensitive factors can be identified, especially under considerations of uncertainties. It can help decision-makers enhance environmental consideration and take measures in the early stage of decision-making.

54 ENVIRONMENTAL SCIENCES↗

An integrated approach for water scarcity evaluation—a case study of Yunnan, China

In this paper, an integrated approach based on multiple indicators and individual and combinational evaluation methods is proposed to evaluate water scarcity. Four evaluation methods are employed, and their results are joined through three combination methods in order to obtain a consistent evaluation. This iterative-correction approach has been applied to Yunnan Province in China for water scarcity evaluation. The results demonstrate the capability of the iterative-correction framework to provide insightful analyses of water scarcity. Diqing Tibetan Autonomous Prefecture (Diqing) and Nujiang Li Autonomous Prefecture (Nujiang) ranked 1st and 2nd, indicating the best situation for water scarcity evaluation, while Yuxi and Zhaotong ranked 15th and 16th, indicating the worst situation. Two types of major water scarcities were observed in Yunnan Province. One was a typical representative of lack of water quality in the central part of Yunnan, and the other was a typical engineering type in the western part of Yunnan. The water scarcity has been found to arise from non-judicious water use, rapid urbanization and lack of protective measures for water resources. Finally and therefore, it is necessary to conduct more water conservancy projects in future to alleviate the water scarcity issue.

54 ENVIRONMENTAL SCIENCES↗

Water Analysis of the Heat Melt Compactor

The Heat Melt Compactor (HMC) recovers water from trash at low temperatures and under vacuum conditions to obtain relatively cleaner water with less contaminants. The effluent water vapor is condensed and collected for analysis. The objectives of the analysis are to identify chemical components in the water sample, evaluate water quality, and assess the compatibility of the liquid effluent with the International Space Station (ISS) water systems. The evaluation of water quality includes total organic carbon (TOC) concentrations which provide a general indication of overall water quality, other defining characteristics such as pH and conductivity, and comparison with previous ISS water analytical data as a baseline for the evaluation.

trash↗

Multifamily Heat Pump Water Heater Evaluation

Although heat pump water heaters (HPWHs) have gained significant attention in recent years as a high efficiency electric water heating solution for single family homes, central HPWHs for commercial or multi-family applications are not as well documented in terms of measured performance and cost effectiveness. To evaluate this technology, the Alliance for Residential Building Innovation team monitored the performance of a 10.5 ton central HPWH installed on a student apartment building at the West Village Zero Net Energy Community in Davis, California. Monitoring data collected over a 16 month period were then used to validate a TRNSYS simulation model. The TRNSYS model was then used to project performance in different climates using local electric rates. Results of the study indicate that after some initial commissioning issues, the HPWH operated reliably with an annual average efficiency of 2.12 (Coefficient of Performance). The observed efficiency was lower than the unit's rated efficiency, primarily due to the fact that the system rarely operated under steady-state conditions. Changes in the system configuration, storage tank sizing, and control settings would likely improve the observed field efficiency. Modeling results suggest significant energy savings relative to electric storage water heating systems (typical annual efficiencies around 0.90) providing for typical simple paybacks of six to ten years without any incentives. The economics versus gas water heating are currently much more challenging given the current low natural gas prices in much of the country. Increased market size for this technology would benefit cost effectiveness and spur greater technology innovation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗