Search NASA⌕ Search

SEARCH · Search NASA

Results for “water vapor pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Distributions of eight meteorological variables at Cape Kennedy, Florida and Vandenberg Air Force Base, California

Extreme values, median values, and nine percentile values are tabulated for eight meteorological variables at Cape Kennedy, Florida and at Vandenberg Air Force Base, California. The variables are temperature, relative humidity, station pressure, water vapor pressure, water vapor mixing ratio, density, and enthalpy. For each month eight hours are tabulated, namely, 0100, 0400, 0700, 1000, 1300, 1600, 1900, and 2200 local time. These statistics are intended for general use for the space shuttle design trade-off analysis and are not to be used for specific design values.

Graves, M. E.↗

Improving the Estimation of the Atmospheric Water Vapor Pressure Using Interpretable Long Short-Term Memory Networks: Dataset, Python code, and trained models

Atmospheric water vapor pressure is an essential meteorological control on land surface and hydrologic processes. It is not as frequently observed as other meteorologic conditions, but often inferred through the August–Roche–Magnus formula by simply assuming dew point and daily minimum temperatures are equivalent or by empirically correlating the two temperatures using an aridity correction. The performance of both methods varies considerably across different regions and during different time periods; obtaining consistently accurate estimates across space and time remains a great challenge. We applied an interpretable Long Short-Term Memory (iLSTM) network conditioned on static, location specific attributes to estimate daily vapor pressure for 83 FLUXNET sites in the United States and Canada. This data package includes all raw data of the 83 FLUXNET sites, input data for model training/validation/test, trained models and results, and python codes for the manuscript "Improving the Estimation of the Atmospheric Water Vapor Pressure Using an Interpretable Long Short-term Memory Network". Specifically, it consists of five parts. - First, "1_Daymet_data_83sites.zip" includes raw data downloaded from Daymet for the 83 sites used in the paper according to their longitude and latitude, in which vapor pressure is used. It also includes a pre-processed CSV data file combining all data from the 83 sites which is specifically used for the paper. - Second, "2_Fluxnet2015_data_83sites.zip" includes raw half hourly data of the 83 sites downloaded from FLUXNET2015 data portal, pre-processed daily data of the 83 sites, a CSV file including combined pre-processed daily data of the 83 sites, and a CSV file including the information (site ID, site name, latitude, longitude, data available period) of the 83 sites. - Third, "3_MODIS_LAI_data_83sites_raw.zip" includes raw leaf area index (LAI) data downloaded from the AppEEARs data portal. - Fourth, "4_Scripts.zip" includes all scripts related to model training and post-processing of a trained model, and a jupyter notebook showing an example for model post-processing. Two typo errors in files titled "run2get_args.py" and "postprocess.py" were corrected on March 27, 2024 to avoid confusions. - Finally, "Trained_models_and_results.zip" includes three folders and three files with suffix ".npy", and each folder corresponds to one file with suffix ".npy" with the same title. Each of the three folders include all trained models associated with one iLSTM model configuration (35 models for each configuration, details are described in the paper). Each file with suffix ".npy" includes the post-processed results of the corresponding 35 models under one iLSTM model configuration.

54 ENVIRONMENTAL SCIENCES↗

The Oxidation Rate of SiC in High Pressure Water Vapor Environments

CVD SiC and sintered alpha-SiC samples were exposed at 1316 C in a high pressure burner rig at total pressures of 5.7, 15, and 25 atm for times up to 100h. Variations in sample emittance for the first nine hours of exposure were used to determine the thickness of the silica scale as a function of time. After accounting for volatility of silica in water vapor, the parabolic rate constants for Sic in water vapor pressures of 0.7, 1.8 and 3.1 atm were determined. The dependence of the parabolic rate constant on the water vapor pressure yielded a power law exponent of one. Silica growth on Sic is therefore limited by transport of molecular water vapor through the silica scale.

Opila, Elizabeth J.↗

Water-vapor pressure control in a volume

The variation with time of the partial pressure of water in a volume that has openings to the outside environment and includes vapor sources was evaluated as a function of the purging flow and its vapor content. Experimental tests to estimate the diffusion of ambient humidity through openings and to validate calculated results were included. The purging flows required to produce and maintain a certain humidity in shipping containers, storage rooms, and clean rooms can be estimated with the relationship developed here. These purging flows are necessary to prevent the contamination, degradation, and other effects of water vapor on the systems inside these volumes.

Scialdone, J. J.↗

Determination of Spectral Line Parameters in Selected Portions of the Infrared Spectrum of Water Vapor

Pressure broadening and pressure-induced shift coefficients due to water and nitrogen have been determined for water vapor transitions in the CO2 region of interest to Project HALOE. The temperature dependences of the widths and shifts have also been determined for selected transitions in this region. Results have been compared with values available in the literature. The line parameters have been obtained from the analysis of room temperature recordings of the spectrum of pure water and recordings of the spectra of heated water/nitrogen mixtures. The recordings of the water vapor spectrum were obtained with Fourier Transform Spectrometers at Kitt Peak and at the Justus-Liebig-Universitat Giessen. Up to eighteen spectra have been fitted simultaneously with a multispectrum nonlinear least-squares fitting technique developed by Dr. D. Chris Benner and colleagues.

Albert, Karen Keppler↗

Effects of Water Vapor on the Reactivity of Aluminosilicates in Vapor-Phase Propanal Aldol Condensation

Aluminosilicate materials have been extensively studied as efficient aldol catalysts for C-C coupling reactions due to their acidic nature, high surface area, thermal stability, and porous structure. This work investigated the impact of water vapor pressure on the catalytic reactivity of aluminosilicates for the aldol condensation of propanal to 2-methyl-2-pentenal (MP). The catalytic performance of amorphous SiO2-Al2O3 (A-Si-Al) and aluminated MCM-41 (Al-MCM-41) for the vapor-phase aldol condensation of propanal was evaluated at 200 degrees C as a function of vapor-phase water content at atmospheric pressure. Our findings demonstrate that co-feeding low water vapor pressures (1-18 kPa) with propanal enhances the rates of MP production at 200 degrees C on A-Si-Al. Conversely, water vapor pressures of 25 kPa result in a decrease in aldol dimer formation rates. The rate of MP production evaluated on Al-MCM-41 also increased in the presence of 5 kPa water compared to anhydrous conditions. Propylamine temperature-programmed desorption analyses revealed an increase in Bronsted acid site density when both catalysts were exposed to water, which likely accounts for the observed enhancement in aldol condensation reactivity under hydrous conditions. Reversibility testing of the water vapor effect under reaction conditions, combined with X-ray diffraction analysis of fresh, spent, and regenerated catalysts, revealed no structural changes in either aluminosilicate upon exposure to water or reaction conditions. The rates of aldol condensation and the impact of water vapor were highly consistent across both materials, suggesting that zeolite crystallinity has minimal influence on the catalytic performance.

acid catalysts↗

Estimation of Aerosol Optical Depth, Pressure Elevation, Water Vapor and Calculation of Apparent Surface Reflectance from Radiance Measured by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) Using a Radiative Transfer Code

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is an imaging spectrometer that measures spatial images of the total up welling spectral radiance from 400 to 2500 nm at 10 nm spectral intervals. Quantitiative research and application objectives for surface investigations require conversion of the measured radiance to surface reflectance or surface leaving radiance. In this paper we describe a set of algorithms to estimate aerosol optical depth, atmospheric water vapor, and surface pressure height from the AVIRIS measured radiance.

infrared↗

Oxidation of chemically-vapor-deposited silicon nitride and single-crystal silicon

The present 1000 C and 1300 C oxidation tests on 111-oriented single-crystal Si and dense CVD Si3N4 notes the oxidation rates of the latter in wet O2, dry O2, wet inert gas, and steam atmosphere conditions to be several orders of magnitude lower than the rates for the former in identical atmospheric conditions. Although the parabolic rate constant for Si increased linearly as the water vapor pressure increased, the parabolic rate constant for Si3N4 exhibited a nonlinear dependency on water vapor pressure in the presence of O2. NO and NH3 formation at the reaction interface of Si3N4, and the counterpermeation of these reaction products, are noted to dominate reaction kinetics.

Choi, Doo J.↗

A radiative transfer model for surface radiation budget studies

A high resolution spectral radiative transfer model of the troposphere for computing downwelling radiance and flux density at the surface in the 5-200 micron region has been developed. The model is fast and accurate and takes into consideration all major and minor constituents active in this region, namely, water vapor, carbon dioxide, ozone, nitrous oxide, and methane. It uses the quasi-random band model of absorption for computing atmospheric transmittances due to various bands. Continuum absorption by water vapor in the 8-14 micron region has also been taken into account. The model has been used to examine the sensitivity of downwelling flux to variations of surface water vapor pressure (or surface relative humidity), water vapor scale-height and concentrations of other gaseous constituents of the atmosphere. In addition, sensitivity to changes in a number of cloud parameters, namely, fractional cloud cover, cloud height, and high-cloud emissivity, has also been examined. Results obtained with the present model compare well with those from the empirical and semi-empirical correlations. The present work demonstrates, for the first time, the feasibility of using a high-resolution narrow-band model for computing this flux for a meteorological application.

Gupta, S. K.↗

Evaluation of Mechanical and Thermomechanical Water Vapor Compression Techniques for Enabling High Temperature Lift Hydration-Based Chemical Heat Pumps

Achieving high temperature lifts (>200 K) via a chemical heat pump based on salt hydration/dehydration reactions requires the transport of water vapor from low to high pressure. Alternative compression approaches require condensing of low-pressure water vapor, pumping of liquid water, and subsequent evaporation when the low-side pressure corresponds to sub-ambient water saturation temperatures. Thus, this study compares four steam compression methods for use within a chemical heat pump system based on a reversible calcium oxide hydration/dehydration reaction with a temperature lift from 350 °C heat to >600 °C. Purely mechanical and thermochemical/mechanical compression technologies are considered. A parametric study of maximum allowable temperature, the isentropic efficiency of mechanical compressors, the effectiveness of heat exchangers, and the assumed allowable heat exchanger pressure drop is conducted to determine the mechanical and thermal energy consumed per kilogram of compressed steam. The system complexity in terms of the number of main system components, maximum pressure ratio, and maximum allowable temperature is estimated. Model results show an absorption-based steam compressor has the highest exergetic efficiency for the required chemical heat pump required conditions. As a result, this system configuration was then experimentally demonstrated to illustrate the impact of system performance on component effectiveness.

Advanced reactors↗

Cape Canaveral, Florida range reference atmosphere 0-70 km altitude

The RRA contains tabulations for monthly and annual means, standard deviations, skewness coefficients for wind speed, pressure temperature, density, water vapor pressure, virtual temperature, dew-point temperature, and the means and standard deviations for the zonal and meridional wind components and the linear (product moment) correlation coefficient between the wind components. These statistical parameters are tabulated at the station elevation and at 1 km intervals from sea level to 30 km and at 2 km intervals from 30 to 90 km altitude. The wind statistics are given at approximately 10 m above the station elevations and at altitudes with respect to mean sea level thereafter. For those range sites without rocketsonde measurements, the RRAs terminate at 30 km altitude or they are extended, if required, when rocketsonde data from a nearby launch site are available. There are four sets of tables for each of the 12 monthly reference periods and the annual reference period.

Tingle, A.↗

Influence of Proton Activity Gaps between Electrodes on Open-Circuit Potential of H 2 /H 2 and H 2 /Air Cells

Polymer -electrolyte-fuel-cell open-circuit voltages (OCVs) are exactly defined by equation (1), where cathode and anode proton activities [(aH+)cathode and (aH+)anode, respectively] usually are identical, so the third term in the right-hand side of equation (2) is ignored. OCV=E0+RT/2F*ln(a1/2 O2*(a2 H+)cathode/aH2O)-RT/2F*ln((a2 H+)anode/aH2) (1) =E0+RT/2F*ln(a1/2 O2*aH2/aH2O)+RT/2F*ln((a2 H+)cathode/(a2 H+)anode) (2) Water vapor pressure is a colligative property that fundamentally correlates to electrolyte concentrations in aqueous solutions. Proton activity is a function of acid concentration, such as pH, when electrolytes are acids. In polymer-electrolyte membranes, water vapor pressure and acid concentration are understood as relative humidity (RH) and water uptake (λ), respectively, where λ represents number of water molecules per sulfonic acid molecule. Several investigations have reported the relationship between RH and λ, meaning that proton activities and associated water uptakes are intimately related to RH. In actual fuel cell operation, cathode RH is determined by ambient-atmosphere and/or humidifier RH(s), and anode RH depends on hydrogen-circulator RH. Therefore, RH is not always identical at both electrodes, and the difference between electrode RHs is considerable during dry operation of polymer electrolyte fuel cells. Therefore, the third term in the right-hand side of equation (2) may be significant for dry operation. We measured OCVs when hydrogen was supplied to both electrodes at 80°C. One electrode (A) was fixed at 30% RH, while RH at the other electrode (B) was varied (0, 5, 10, 20, and 30%). Measured OCVs varied from 0 to 75 mV. For fuel cell tests, electrode A was supplied with hydrogen at 30% RH; electrode B, oxygen at 0, 5, 10, 20, and 30% RH. OCVs deviated from that measured when RH at electrode B was 30%, increasing from 0 to 60 mV with decreasing RH at electrode B. Results are also shown in Figure 1. Proton activities of both electrodes were thermodynamically calculated. The Gibbs–Duhem relation was applied to obtain molar Gibbs free energies of water and sulfonic acid, and proton activity coefficient was calculated using the Gibbs free energy of sulfonic acid and the relationship between RH and λ1–4, assuming that protons and sulfonic anions show identical ionic-activity coefficients. OCVs were estimated using the third term in the right-hand side of equation (2). Results are shown in Figure 1. Fuel-cell current–voltage performance was poor when RHs at the anode and cathode were 30 and 20%, respectively. To determine kinetic current, we measured the oxygen-reduction reaction (ORR) using a rotating-disk electrode (RDE) in concentrated-acid aqueous solutions, which modeled catalyst-layer ionomers. Kinetic currents decreased with acid concentrations. References T. A. Zawodzinski, Jr., C. Derouin, S. Radzinski, R. J. Sherman, V. T. Smith, T. E. Springer and S. Gottesfeld , J. Electrochem. Soc., 140,1041 (1993) P. K. Das and A. Z. Weber, Proceedings of the ASME 2013 11th Fuel Cell Science, Engineering and Technology Conference, Fuel Cell 18010 (2013) V. A. Sethuraman, J. W. Weidner, A. T. Haug, S. Motupally,b and L. V. Protsailo, J. Electrochem. Soc., 155, B50 (2008) A. Kusoglu and A. Z. Weber, Chem. Rev., 117, 987 (2017) Figure 1

Yoshida, Toshihiko↗

Chemical reaction between water vapor and stressed glass

The crack velocity in soda-lime silicate glass was determined at room temperature at water-vapor pressures of 10 to 0.04 torr using the double torsion technique. A precracked glass specimen (70 x 16 x 1.6 mm) was placed in a vacuum chamber containing a four-point bending test apparatus. The plotted experimental results show that the crack propagation curve in water agrees fairly well with that of Wiederhorn (1967). Attention is given to the effect of water vapor pressure on crack velocity at K(I) = 550,000 N/m to the 3/2 power, with (Wiederhorn's data) or without N2 present. The plotted results reveal that the present crack velocity is about two orders of magnitude higher than that of Wiederhorn at high water-vapor conditions, but the difference decreases as the water-vapor concentration diminishes or the crack velocity slows down.

Soga, N.↗

Respiratory weight losses during exercise.

Evaporative water loss from the respiratory tract was determined over a wide range of exercise. The absolute humidity of the expired air was the same at all levels of exercise and equal to that measured at rest. The rate of respiratory water loss during exercise was found to be 0.019 of the oxygen uptake times (44 minus water vapor pressure). The rate of weight loss during exercise due to CO2-O2 exchange was calculated. For exercise at oxygen consumption rates exceeding 1.5 L/min in a dry environment with a water vapor pressure of 10 mm Hg, the total rate of weight loss via the respiratory tract is on the order of 2-5 g/min.

Mitchell, J. W.↗