Search NASA⌕ Search

SEARCH · Search NASA

Results for “wave energy converter testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

New Report Highlights LAMP's Role as a Robust and Reliable System for Wave Energy Converter Testing

Harnessing the power of waves requires more than just putting devices in the ocean - it takes tools that can refine and accelerate innovation before the first deployment. That's where NLR's largeamplitude motion platform, or LAMP, comes in. LAMP is a six-degree-of-freedom motion system designed to replicate the response of a wave energy converter (WEC) device in realistic ocean conditions. By letting researchers evaluate WEC performance in a safe, controlled lab environment before moving offshore, LAMP helps accelerate innovation while reducing risk. An NLR report, titled Initial Characterization of the NLR LargeAmplitude Motion Platform (https://www.nrel.gov/docs/fy26osti/93733.pdf), provides a deeper understanding of LAMP's capabilities and also lays the groundwork for future advancements in WEC testing methodologies. Researchers studied LAMP's amplitude and frequency limits across different payloads and collected data from 16 test profiles. Testing demonstrated that platform accuracy remained consistent across all payloads evaluated; researchers expect similar accuracy up to LAMP's 10,000-kilogram capacity limit. The measured position limits for single degrees of freedom experienced by WECs, including surge, sway, heave, roll, pitch, and yaw, also exceeded the original manufacturer specifications, providing new insight into the true boundaries of the system.

16 TIDAL AND WAVE POWER↗

Performance characterization and modeling of an oscillating surge wave energy converter

Abstract Testing wave energy converters in the ocean could be expensive and complex, which necessitates the use of numerical modeling. However, accurately modeling the response of wave energy converters with high-fidelity simulations can be computationally intensive in the design stage where different configurations must be considered. Reduced-order models based on simplified equations of motion can be very useful in the design, optimization, or control of wave energy converters. Given the complex dynamics of wave energy converters, accurate representation, and evaluation of relative contributions by different forces are required. This effort is concerned with a performance characterization of the hydrodynamic response of an oscillating surge wave energy converter that is based on a reduced-order model. A state-space model is used to represent the radiation damping term. Morison’s representation of unsteady forces is used to account for the nonlinear damping. Wave tank tests are performed to validate simulations. A free response simulation is used to determine the coefficients of the state-space model. Torque-forced simulations are used to identify the coefficients of the nonlinear damping term for different amplitudes and wave frequencies. The impact of varying these coefficients on the response is investigated. An assessment of the capability of the model in predicting the hydrodynamic response under irregular forcing is performed. The results show that the maximum error is 3% when compared with high-fidelity simulations. It is determined that the nonlinear damping is proportional to the torque amplitude and its effects are more pronounced as the amplitude of the flap oscillations increases.

16 TIDAL AND WAVE POWER↗

Dynamic Mooring Field Experiment and Design of a Wave Energy Converter Platform Test System

Abstract This study evaluated a multi-catenary spread mooring system design of a mobile ocean test berth for wave energy converters (WECs), the Ocean Sentinel (OS) instrumentation buoy, through dynamic simulation, numerical analysis, and comparison with measured field motion data of the OS off the OR coast. First, the accuracy of the numerical employed model based on a fully-coupled method of the OS and its mooring lines was validated by comparing predicted mooring tensions to the field measurements. Then, the anchor movability, fatigue damage, and extreme mooring tension of the OS mooring system were analyzed to assess survivability. Field test results show that the numerical model provided accurate predictions of mooring tensions even under environmental conditions of strong wind, current, and waves. Factors affecting the accuracy are discussed. One mooring anchor was shown to have moved significantly during the ocean field test. Mooring fatigue damage was calculated for different levels of sea states. Design strengths of the mooring lines were calculated and analyzed.

Engineering↗

A compact mechanical power take-off for wave energy converters: Design, analysis, and test verification

Power Take-off (PTO) is one of the most critical components in the ocean wave conversion. This paper introduces an innovative compact mechanical PTO using a ball screw mechanism and a Mechanical Motion Rectifier (MMR) to improve the energy conversion performance. The proposed MMR PTO converts bidirectional oscillatory motion of the ocean waves into unidirectional rotation. The detailed design and working principle of the MMR PTO are explicitly explained. Dynamic analysis is presented for the three most important factors that influence the performance, including the equivalent mass, the equivalent damping, and the excitation frequency. The analytical relationship between these factors and the disengaged freewheeling motion caused by the MMR mechanism is derived, and the analytical solution is verified through dry lab testing. Experimental results in bench tests show that compared with the traditional linear PTO which use the ball screw to drive the generator directly, the MMR PTO is more efficient because of the unique freewheeling motion, achieving a maximum 81.2% energy transfer efficiency. After integrating the prototype PTO with a single-body point absorber type of wave energy converter, testing in a water tank yields total PTO efficiency up to 62.4%, showing a very promising potential for real applications.

16 TIDAL AND WAVE POWER↗

Hardware-in-the-loop testing of a hydraulic wave energy power take-off system

This report describes testing conducted related to the development of a “hydrostatic power takeoff” (HPTO) system for a wave energy converter. Tests were conducted with an experimental electric motor rig to provide preliminary results and de-risk future testing. Efficiency mapping tests were conducted as well as hardware-in-the-loop (HIL) testing. The results of the efficiency mapping tests provide good insight into how to systematically perform efficiency mapping tests. The HIL testing indicates good overall performance of the system and provides a stepping stone towards more complete system tests in the future.

16 TIDAL AND WAVE POWER↗

Using Fiducial Markers for Pose Estimation of an OSWEC in a Wave Tank: Preprint

In this study, we consider a novel method of sensing the motion of a wave energy converter during testing in a wave flume under the influence of incoming waves. The wave energy converter considered in our research is an oscillating surge wave energy converter, which is a hinged paddle that responds to incoming waves. Motion sensing is normally done with inertial sensors, which can hinder the motion due to suspended cables that carry power and transmit signals. Our proposed method is contactless and can be implemented economically. A camera is used to record different marker patterns affixed to the moving paddle and the motion deduced by pose estimation algorithms. Fiducial markers are commonly used for robot localization and in augmented reality. There are many types of fiducial markers, including ArUco-type markers which are accurate, fast and robust. The system consists of markers attached to the paddle element and recorded using a machine vision camera. A pose estimation algorithm is then applied to the detected markers to estimate the tilt of the paddle. In this work, we examine the challenges of image acquisition and calibration for underwater targets, compare the motion obtained by this new system with a calibrated tilt sensor and identify areas where the new system may be superior.

computer vision↗

Performance analysis and tank test validation of a hybrid ocean wave-current energy converter with a single power takeoff

This paper introduces a hybrid ocean wave-current energy converter (HWCEC) that harvests energy from ocean waves and current simultaneously with a single power takeoff (PTO). Specifically, the wave energy is extracted through relative heaving motion between a floating buoy and a submerged second body, while the current energy is extracted using a marine current turbine (MCT). Energy from both sources are integrated by a hybrid PTO whose concept is based on a mechanical motion rectifier (MMR). The hybrid PTO with two one-way clutches converts bidirectional, up-and-down motion from the waves into unidirectional rotation of the generator. Meanwhile a third one-way clutch couples the MCT with the same generator. The wave and current can simultaneously or separately drive the same generator through different engagement and disengagement statuses of the one-way clutches. Time-domain simulation is conducted with hydrodynamic coefficients obtained from computational fluid dynamics analysis and boundary element method. Tank tests were conducted for a HWCEC under co-existing wave and current inputs. For comparison, separate baseline tests of a turbine and a two-body point absorber, each acting in isolation, are conducted. Experimental results validate the dynamic modeling and show that a HWCEC can increase the output power with a range between 29-87% over either current turbine and wave energy converter acting individually, and it can reduce by up to 70% the peak-to-average power ratio compared with the wave energy converter on the tested conditions.

16 TIDAL AND WAVE POWER↗

Biofouling Analysis for Wave Energy Piston Design: Post-Access Test Report

This report summarizes the purpose, procedures, results, and conclusions of prolonged seawater tank testing of a prototype wave energy converter apparatus. Test objectives included determination of the effectiveness of a biofouling mitigation element in one test assembly compared to a control, and system force over many cycles of actuation over months.

16 TIDAL AND WAVE POWER↗

Numerical wave modeling for operational and survival analyses of wave energy converters at the US Navy Wave Energy Test Site in Hawaii

The US Navy Wave Energy Test Site (WETS) is currently operating three grid-connected berths off Marine Corps Base Hawaii in support of technological development through scaled-model testing and pre-commercial prototyping. The location on the east shore of Oahu is open to year-round wind waves and seasonal north swells as well as severe seas from subtropical systems and hurricanes. We have assembled a spectral wave model system comprising WAVEWATCH III and SWAN on a hierarchy of global, regional, and nearshore computational grids. With wind forcing from global forecast and rean-alysis datasets as well as their regional downscaling, the system produces operational 7-day wave forecasts and a long-term hindcast. The daily forecasts, validated with real-time buoy measurements, facilitate safe deployment, operation, and retrieval of wave energy converters (WECs). The wave hindcast from 1979 to 2017 defines the intra- and inter-annual variations for statistical analysis of sea states and energy resources. Due to limited occurrences of hurricanes in Hawaii waters, their wind forcing is determined parametrically with simulated tracks from climate model downscaling. Finally, systematic analysis of the hindcast and simulation datasets provides significant wave heights from trade winds, swells, subtropical systems, and hurricanes with return periods up to 100 years for WECs survival analysis.

16 TIDAL AND WAVE POWER↗

FOSWEC dynamics and controls test report

This report describes the testing of a model scale wave energy converter. This device, which uses two aps that pivot about a central platform when excited by waves, has a natural frequency within the range of the waves by which it is excited. The primary goal of this test was to assess the degree to which previously developed modeling, experimentation, and control design methods could be applied to a broad range of wave energy converter designs. Testing was conducted to identify a dynamic model for the impedance and excitation behavior of the device. Using these models, a series of closed loop tests were conducted using a causal impedance matching controller. This report provides a brief description of the results, as well as a summary of the device and ex- perimental design. The results show that the methods applied to this experimental device perform well and should be broadly applicable.

16 TIDAL AND WAVE POWER↗

FOSWEC v2: System identification and control testing at Hinsdale Wave Research Laboratory

This report summarizes the design and execution of a wave tank test of the floating oscillating surge wave energy converter (FOSWEC) in the O.H. Hinsdale Wave Research Laboratory Directional Wave Basin at Oregon State University. This device, which uses two "flaps" that pivot about a central platform when excited by waves, has a natural frequency within the range of the waves by which it is excited. The FOSWEC was originally considered to be a 1:33 scale device, however, for the current tests, no fixed relative scale is used (i.e., the WEC is considered to be scaled for the basin’s wave environment in which it operates). The primary goal of this test was to assess the degree to which previously developed modeling, experimentation, and control design methods could be applied to a broad range of wave energy converter designs. Testing was conducted to identify a dynamic model for the impedance and excitation behavior of the device. Using these models, a series of closed loop tests were conducted using a causal impedance matching controller. This report provides a brief description of the results, as well as a summary of the device and experimental design. The results show that the methods applied to this experimental device perform well and should be broadly applicable. The data collected during testing is compressed into FOSWEC.zip. Please refer to Appendix C (pages 61-63) of the test report for descriptions of each test ID corresponding to the compressed files.

16 TIDAL AND WAVE POWER↗

Review of Wave Energy Converter Power Take-Off Systems, Testing Practices, and Evaluation Metrics: Preprint

While the field of wave energy has been the subject of numerical simulation, scale model testing, and precommercial project testing for decades, wave energy technologies remain in the early stages of development and must continuing proving themselves as a promising modern renewable energy field. One of the difficulties that wave energy systems have been struggling to overcome is the design of highly efficient energy conversion systems that can convert the mechanical power, derived from the oscillation of wave activated bodies, into another useful product. Often the power take-off (PTO) is defined as the single unit responsible for converting mechanical power into another usable form such as electricity, pressurized fluid, compressed air, and others. The PTO, and the entire power conversion chain (PCC), is of great importance as it affects not only how efficient wave power is converted into electricity, but also contributes to the mass, size, structural dynamics, and levelized cost of energy (LCOE) of the wave energy converter (WEC). Unlike wind and solar, there is no industrial standard device, or devices, for wave energy conversion and this diversity is transferred to the PTO system. The majority of current WEC PTO systems incorporate a mechanical or hydraulic drive train, power generator, and an electrical control system. The challenge of WEC PTO designs is designing a mechanical-to-electrical component that can efficiently convert irregular, bi-directional, low frequency and low alternating velocity wave motions. While gross average power levels can be predicted in advance, the variable wave elevation input has to be converted into smooth electrical output and hence usually necessitates some type of energy storage system, such as battery storage, accumulator super capacitors, etc., or other means of compensation such as an array of devices. One of the primary challenges for wave energy converter systems is the fluctuating nature of wave resources, which require WEC components to be designed to handle loads (i.e. torques, forces, and powers) that are many times greater than the average load. This approach requires a much greater PTO capacity than the average power output and indicates a higher cost. In addition, supporting mechanical coupling and or gearing can be added to the PCC to help alleviate the difficulties with transmission and control of fluctuating large loads with low frequencies (indicative of wave forcing) into smaller loads at higher frequencies (optimum for conventional electrical machine design) can quickly increase the complexity of the PCC which could result in a greater number of failure modes and increased maintenance costs. All of the previous points demonstrate how the PTO influences WEC dynamics, reliability, performance and cost which are critical design factors. This paper further explores these topics by providing a review of the state-of-the-art PTO systems currently under development, how these novel PTO systems are tested and derisked prior to precommercial deployment, and the evaluation metrics historically used to differentiate between PTO designs and how they can be improved to support control co-design focused development of wave energy systems.

laboratory testing↗

Initial Characterization of the NREL Large-Amplitude Motion Platform

The Large Amplitude Motion Platform (LAMP) at NREL represents a significant advancement in the controlled testing of Wave Energy Converters (WECs) under laboratory conditions. Originally designed by E2M as a six-degree-of-freedom (DOF) Stewart platform for flight simulation, LAMP has been adapted by NREL to facilitate the mounting and evaluation of WECs. This adaptation enables dry testing of WECs using motion profiles similar to the ocean, facilitating the iterative design, testing, and validation of WEC performance prior to ocean deployments. This report presents the initial work completed to characterize LAMP, with particular emphasis on its stability and operational capabilities across various single and multi-degree-of-freedom (DOF) motion profiles. The report includes planned comparisons at three distinct mass payloads, aimed at assessing the platform's positional accuracy, frequency response, and endurance over extended runtime periods. These experimental tests are critical for establishing the platform's limitations and ensuring that the data generated during WEC validation is both accurate and reproducible. The outcomes of this study not only contribute to a deeper understanding of LAMP's capabilities but also lay the groundwork for future advancements in WEC testing methodologies. By providing robust and reliable performance data within a controlled laboratory setting, the findings are expected to significantly enhance the development and commercialization of marine energy technologies. This report presents the initial findings of the LAMP Characterization work and proposed steps to further understand and characterize LAMP. Data collected during this work can be found on MHKDR at: https://mhkdr.openei.org/submissions/602 Note that this report shares the measured/found instantaneous maximum operating range of LAMP. For most applications the maximum operating range cannot be used for system health and longevity. The operating range and capabilities of LAMP will be evaluated on a case-by-case basis, single-DOF position, velocity, and acceleration values presented in Table 4a-c, and Table 5 should be taken as instantaneous absolute maximum values. Future use of LAMP will likely be limited to smaller values.

16 TIDAL AND WAVE POWER↗

Met-Ocean Characterization for the Atlantic Marine Energy Center’s (AMEC’s) Gulf of Maine Wave Test Sites

Comprehensive and consistent analysis, characterization, and classification of the wave climate at open-ocean wave energy converter (WEC) test sites guided by international standards enables commensurable evaluation and comparison of met-ocean characteristics, including wave energy resources and wave load conditions. Herein, we present results from a comprehensive feasibility-level met-ocean characterization for two Atlantic Marine Energy Center (AMEC) WEC test sites in the Gulf of Maine.

16 TIDAL AND WAVE POWER↗