Search NASA⌕ Search

SEARCH · Search NASA

Results for “wave front sensing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

High-speed Focal Plane Wave Front Sensing with an Optical Chopper

Focal plane wave front sensing and control is a critical approach to reducing noncommon path errors between a conventional astronomical adaptive optics (AO) wave front sensor (WFS) detector and a science camera. However, in addition to mitigating noncommon path errors, recent focal plane wave front sensing techniques have been developed to operate at speeds fast enough to enable "multi-WFS" AO, where residual atmospheric errors are further corrected by a focal plane WFS. Although a number of such techniques have been recently developed for coronagraphic imaging, here we present one designed for noncoronagraphic imaging. Utilizing conventional AO system components, this concept additionally requires (1) a detector imaging the focal plane of the WFS light source and (2) a pupil plane optical chopper device that is the noncommon path to the first WFS and is synchronized to the focal plane imager readout. These minimal hardware requirements enable the temporal amplitude modulation to resolve the sine ambiguity of even wave-front modes for low, mid, and high wave front spatial frequencies. Similar capabilities have been demonstrated with classical phase diversity by defocusing the detector, but such techniques are incompatible with simultaneous science observations. This optical chopping technique, however, enables science imaging at up to 50% duty cycle. In conclusion, we present both simulations and laboratory validation of this concept on SEAL, the Santa Cruz Extreme AO Laboratory testbed.

79 ASTRONOMY AND ASTROPHYSICS↗

Early High-contrast Imaging Results with Keck/NIRC2-PWFS: The SR 21 Disk

High-contrast imaging of exoplanets and protoplanetary disks depends on wave front sensing and correction made by adaptive optics instruments. Classically, wave front sensing has been conducted at optical wavelengths, which made high-contrast imaging of red targets such as M-type stars or extincted T Tauri stars challenging. Keck/NIRC2 has combined near-infrared (NIR) detector technology with the pyramid wave front sensor (PWFS). With this new module we observed SR 21, a young star that is brighter at NIR wavelengths than at optical wavelengths. Compared with the archival data of SR 21 taken with the optical wave front sensing we achieved ~20% better Strehl ratio in similar natural seeing conditions. Further post-processing utilizing angular differential imaging and reference-star differential imaging confirmed the spiral feature reported by the Very Large Telescope/Spectro-Polarimetric High-contrast Exoplanet REsearch instrument polarimetric observation, which is the first detection of the SR 21 spiral in total intensity at L' band. We also compared the contrast limit of our result (10 -4 at 0.'4 and 2 × 10 -5 at 1.'0) with the archival data that were taken with optical wave front sensing and confirmed the improvement, particularly at ≤0.'5. Our observation demonstrates that the NIR PWFS improves AO performance and will provide more opportunities for red targets in the future.

79 ASTRONOMY AND ASTROPHYSICS↗

Steerable terahertz beams using surface waves on an active metasurface

The development of dynamic components for controlling wave fronts in the sub-terahertz region of the electromagnetic spectrum has emerged as a frontier research topic for many applications in sensing and communications. One approach which has attracted much attention involves the use of active metasurfaces, tiled arrays of sub-wavelength elements with properties that can be reconfigured via external actuation. In nearly all cases, these metasurfaces are employed as either transmissive or reflective elements, taking advantage of their strong and tunable interaction with free-space electromagnetic waves. These interactions can be significantly enhanced through the use of surface waves propagating parallel to the metasurface array, although very few studies have exploited this option. Here, we integrate a metasurface into the interior of a parallel-plate waveguide in a configuration explicitly designed to exploit this surface-wave geometry. We show that varying the electrical properties of the active metasurface changes the wave vector of the guided mode, and thereby alters the emission angle of radiation out-coupled through a leaky-wave slot aperture. These results, which are consistent with numerical simulations, represent a new approach to broadband beam steering suitable for the sub-terahertz spectral range.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Stability of expanding accretion shocks for an arbitrary equation of state

We present a theoretical stability analysis for an expanding accretion shock that does not involve a rarefaction wave behind it. The dispersion equation that determines the eigenvalues of the problem and the explicit formulae for the corresponding eigenfunction profiles are presented for an arbitrary equation of state and finite-strength shocks. For spherically and cylindrically expanding steady shock waves, we demonstrate the possibility of instability in a literal sense, a power-law growth of shock-front perturbations with time, in the range of $h_c< h<1+2 {\mathcal {M}}_2$ , where $h$ is the D'yakov-Kontorovich parameter, $h_c$ is its critical value corresponding to the onset of the instability and ${\mathcal {M}}_2$ is the downstream Mach number. Shock divergence is a stabilizing factor and, therefore, instability is found for high angular mode numbers. As the parameter $h$ increases from $h_c$ to $1+2 {\mathcal {M}}_2$ , the instability power index grows from zero to infinity. This result contrasts with the classic theory applicable to planar isolated shocks, which predicts spontaneous acoustic emission associated with constant-amplitude oscillations of the perturbed shock in the range $h_c< h<1+2 {\mathcal {M}}_2$ . Examples are given for three different equations of state: ideal gas, van der Waals gas and three-terms constitutive equation for simple metals.

Huete, César (ORCID:0000000232278520)↗

Oceanic fronts shape hemispheric contrasts in polar stratospheric extremes

Sudden Stratospheric Warmings (SSWs) and Polar Stratospheric Clouds (PSCs) exhibit striking inter-hemispheric asymmetries: SSWs are frequent in the Arctic but rare in the Antarctic, while PSCs are more persistent in the Antarctic. Although land–sea thermal contrast and orography (LSCO) have been traditionally invoked to explain these asymmetries, here we show using semi-idealized model experiments that even though LSCO strongly impacts the mean state of SSWs and PSCs, it alone cannot fully account for the observed differences. Using model experiments, we reveal that midlatitude oceanic sea surface temperature (SST) fronts represent a crucial supporting additional driver of the hemispheric stratospheric differences. Like LSCO, SST fronts enhance stratospheric convergence of resolved waves, strengthening the Brewer–Dobson Circulation and inducing high-latitude adiabatic warming. This warming significantly enhances Arctic SSW frequency and strongly suppresses PSC formation. Sub-grid-scale non–resolved wave forcing modulates the stratospheric resolved waves effect. The oceanic impact is dominated by North Pacific SST fronts. Our results highlight the indispensable role of SST fronts in shaping Arctic–Antarctic asymmetries in stratospheric dynamics and associated extremes.

Omrani, Nour-Eddine [Univ. of Bergen (Norway)] (OR↗

Technical Performance and Cost Optimization of Unobtrusive Multi-static Serial LiDAR Imager (UMSLI) for Wide-area Surveillance and Identification of Marine Life at Marine Energy Installations

Florida Atlantic University developed an underwater optical monitoring system prototype - Unobtrusive Multi-static Serial LiDAR Imager (UMSLI) - suitable for marine energy full project lifecycle observation (baseline, commissioning, and decommissioning), with an automated real-time classification of marine animals. With precursor 2014 DOE funding (award DE-EE0006787), a prototype UMSLI was demonstrated in a controlled laboratory environment and achieved a TRL 6. This EERE DE-EE0007828 award aimed to both increase the TRL of the UMSLI by improving the technology performance (e.g., increase distance of marine animal target detection capability, add additional species classification capabilities, improve the system performance during the day, etc.) and reduce the cost. The UMSLI presents a novel application of underwater distributed Light Detection And Ranging (LiDAR), an advanced remote sensing method that uses light in the form of laser pulses for an application, this paired with an algorithm provides 360 degrees underwater detection, imaging, and classification of marine life. This solution for underwater monitoring of biota preserves the advantages of traditional optical and acoustic solutions while overcoming many associated disadvantages for marine energy site environmental monitoring, such as difficulties in species detection and classification in low light or night and turbid environments. This new approach is a purposefully designed, reconfigurable adaptation of an existing class 3B laser technology into one UMSLI instrument that can be easily mounted on or around different classes of marine energy equipment, such as devices to capture ocean current energy or wave energy. The system uses relatively low average power, utilizes far-red (> 635nm) laser illumination to be invisible and eye-safe to marine animals, is compact, and cost-effective. The equipment is designed for long-term, maintenance-free operations (i.e., current design is targeting more than 7 days continuous operation), to inherently generate a sparse primary dataset that only includes detected anomalies, and to allow robust real-time automated animal classification and identification with a low data bandwidth requirement. The technology’s overarching goal for application, is a system that can be deployed to collect pre-installation baseline species observations at a proposed marine energy deployment site with minimal post-processing overhead. The envisioned system will also produce high-resolution imagery of marine animals through a wide range of conditions and support automated tracking and notification of the presence of managed animals within established perimeters of marine energy equipment to satisfy deployed marine energy projects’ endangered and threatened species monitoring requirements. Through the current project, we demonstrated the UMSLI prototype in an operational environment and increased the UMSLI’s Technology Readiness Level from 6 to 7. The project resulted in many novel technologies, including: 1) an eye-safe red laser based, low-cost LiDAR system that can detect targets up to 10 meters distance; 2) the GAN-based machine learning underwater LiDAR image enhancement technique (this is the first known application of GAN technique in underwater LiDAR); 3) LiDAR-based real-time automated detection capabilities; and 4) a template matching based automated classification tool. These technologies build a solid foundation for future efforts to develop an extended range electro-optical monitoring system suitable for marine energy deployments. In addition to technology development, a key lesson learned is that addressing regulatory and safety requirements must be front and center in any marine energy monitoring applications.

16 TIDAL AND WAVE POWER↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗