Search NASA⌕ Search

SEARCH · Search NASA

Results for “wave tank test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Theoretical monochromatic-wave-induced currents in intermediate water with viscosity and nonzero mass transport

Wave-induced mass-transport current theories with both zero and nonzero net mass (or volume) transport of the water column are reviewed. A relationship based on the Longuet-Higgens theory is derived for wave-induced, nonzero mass-transport currents in intermediate water depths for a viscous fluid. The relationship is in a form useful for experimental applications; therefore, some design criteria for experimental wave-tank tests are also presented. Sample parametric cases for typical wave-tank conditions and a typical ocean swell were assessed by using the relation in conjunction with an equation developed by Unluata and Mei for the maximum wave-induced volume transport. Calculations indicate that substantial changes in the wave-induced mass-transport current profiles may exist dependent upon the assumed net volume transport. A maximum volume transport, corresponding to an infinite channel or idealized ocean condition, produces the largest wave-induced mass-transport currents. These calculations suggest that wave-induced mass-transport currents may have considerable effects on pollution and suspended-sediments transport as well as buoy drift, the surface and midlayer water-column currents caused by waves increasing with increasing net volume transports. Some of these effects are discussed.

Talay, T. A.↗

Laser probe for measuring 2-D wave slope spectra of ocean capillary waves

A laser-optical instrument for use in determining the two-dimensional wave-slope spectrum of ocean capillary waves is described. The instrument measures up to a 35-deg tip angle of the surface normal by measuring the position of a refracted laser beam directed vertically upward through a water surface. A telescope, a continuous two-dimensional Schottky barrier photodiode, and a pair of analog dividers render the signals independent of water height and insensitive to laser-beam intensity fluctuations. Calibration is performed entirely in the laboratory before field use. Sample records and wave-slope spectra are shown for one-dimensional wave-tank tests and for two-dimensional ocean tests. These are presented along with comparison spectra for calm and choppy water conditions. A mechanical wave follower was used to adjust the instrument position in the presence of large ocean swell and tides.

Palm, C. S.↗

Inspection of the Space Shuttle External Tank SOFI Using Near-Field and Focused Millimeter Wave Nondestructive Testing Techniques

The Space Shuttle Columbia's catastrophic failure has been attributed to a piece of external tank SOFI (Spray On Foam Insulation) striking the left wing of the orbiter causing significant damage to some of the reinforced carbon/carbon leading edge wing panels. Subsequently, several nondestructive testing (NDT) techniques have been considered for inspecting the external tank. One such method involves using millimeter waves which have been shown to easily penetrate through the foam and provide high resolution images of its interior structures. This paper presents the results of inspecting three different SOFI covered panels by reflectometers at millimeter wave frequencies, specifically at 100 GHz. Each panel was fitted with various embedded anomalies/inserts representing voids and unbonds of diferent shapes, sizes and locations within each panel. In conjunction with these reJqectome&rs, radiators including a focused lens antenna and a small horn antenna were used. The focused lens antenna provided for a footprint diameter of approximately 1.25 cm (0.5") at 25.4 cm (10") away from the lens surface. The horn antenna was primarily operated in its near-field for obtaining relatively high resolution images. These images were produced using 2 0 scanning mechanisms. Discussions of the difference between the capabilities of these two types of antennas (radiators) for the purpose of inspecting the SOFI as it relates to the produced images are also presented.

Kharkovsky, S.↗

The Harp probe - An in situ Bragg scattering sensor

A wave sensor, consisting of parallel, evenly spaced capacitance wires, whose output is the sum of the water surface deflections at the wires, has been built and tested in a wave tank. The probe output simulates Bragg scattering of electromagnetic waves from a water surface with waves; it can be used to simulate electromagnetic probing of the sea surface by radar. The study establishes that the wave probe, called the 'Harp' for short, will simulate Bragg scattering and that it can also be used to study nonlinear wave processes.

Mollo-Christensen, E.↗

Millimeter Wave Detection of Localized Anomalies in the Space Shuttle External Fuel Tank Insulating Foam

The Space Shuttle Columbia's catastrophic accident emphasizes the growing need for developing and applying effective, robust and life-cycle oriented nondestructive testing (NDT) methods for inspecting the shuttle external fuel tank spray on foam insulation (SOFI). Millimeter wave NDT techniques were one of the methods chosen for evaluating their potential for inspecting these structures. Several panels with embedded anomalies (mainly voids) were produced and tested for this purpose. Near-field and far-field millimeter wave NDT methods were used for producing images of the anomalies in these panels. This paper presents the results of an investigation for the purpose of detecting localized anomalies in several SOFI panels. To this end, reflectometers at a relatively wide range of frequencies (Ka-band (26.5 - 40 GHz) to W-band (75 - 110 GHz)) and utilizing different types of radiators were employed. The resulting raw images revealed a significant amount of information about the interior of these panels. However, using simple image processing techniques the results were improved in particular as it relate s to detecting the smaller anomalies. This paper presents the results of this investigation and a discussion of these results.

Kharkovsky, S.↗

Microwave and Millimeter Wave Testing for the Inspection of the Space Shuttle Spray on Foam Insulations (SOFI) and the Acreage Heat Tiles

The utility of microwave and millimeter wave nondestructive testing and evaluation (NDT&E) methods, for testing the Space Shuttle's external he1 tank spray on foam insulation (SOFI) and the acreage heat tiles has been investigated during the past two years. Millimeter wave NDE techniques are capable of producing internal images of SOFI. This paper presents the results of testing several diverse panels with embedded voids and debonds at millimeter wave frequencies. Additionally, the results of testing a set of heat tiles are also presented. Finally, the attributes of these methods as well as the advantageous features associated with these systems are also provided.

Zoughi, R.↗

Millimeter Wave Detection of Localized Anomalies in the Space Shuttle External Fuel Tank Insulating Foam and Acreage Heat Tiles

The Space Shuttle Columbia's catastrophic accident emphasizes the growing need for developing and applying effective, robust and life-cycle oriented nondestructive testing (NDT) methods for inspecting the shuttle external fuel tank spray on foam insulation (SOFI) and its protective acreage heat tiles. Millimeter wave NDT techniques were one of the methods chosen for evaluating their potential for inspecting these structures. Several panels with embedded anomalies (mainly voids) were produced and tested for this purpose. Near-field and far-field millimeter wave NDT methods were used for producing millimeter wave images of the anomalies in SOFI panel and heat tiles. This paper presents the results of an investigation for the purpose of detecting localized anomalies in two SOFI panels and a set of heat tiles. To this end, reflectometers at a relatively wide range of frequencies (Ka-band (26.5 - 40 GHz) to W-band (75 - 110 GHz)) and utilizing different types of radiators were employed. The results clearly illustrate the utility of these methods for this purpose.

Kharkovsky, S.↗

Overview of Microwave and Millimeter Wave Testing Activities for the Inspection of the Space Shuttle SOH and Heat Tiles

Microwave and millimeter wave nondestructive testing and evaluation methods, have shown great potential for inspecting the Space Shuttle s external tank spray on foam insulation (SOFI) and acreage heat tiles. These methods are capable of producing high-resolution images of et interior of these structures. To this end, several different microwave and millimeter wave nondestructive testing methods have been investigated for this purpose. These methods have included near-field as well as focused approaches ranging in frequency from 10 GHz to beyond 100 GHz. Additionally, synthetic aperture focusing methods have also been developed in this regime for obtaining high-resolution images of the interior of these critical structures. These methods possess the potential for producing 3D images of these structures in a relatively short amount of time. This paper presents a summary of these activities in addition to providing examples of images produced using these diverse methods.

Zoughi, R.↗

Acceleration Measurements During Landings of a 1/5.5-Size Dynamic Model of the Columbia XJL-1 Amphibian in Smooth Water and in Waves: Langley Tank Model 208M, TED No. NACA 2336

A 1/5.5-size powered dynamic model of the Columbia XJL-1 amphibian was landed in Langley tank no. 1 in smooth water and in oncoming waves of heights from 2.1 feet to 6.4 feet (full-size) and lengths from 50 feet to 264 feet (full-size). The motions and the vertical accelerations of the model were continuously recorded. The greatest vertical acceleration measured during the smooth-water landings was 3.1g. During landings in rough water the greatest vertical acceleration measured was 15.4g, for a landing in 6.4-foot by 165-foot waves. The impact accelerations increased with increase in wave height and, in general, decreased with increase in wave length. During the landings in waves the model bounced into the air at stalled attitudes at speeds below flying speed. The model trimmed up to the mechanical trim stop (20 deg) during landings in waves of heights greater than 2.0 feet. Solid water came over the bow and damaged the propeller during one landing in 6.4-foot waves. The vertical acceleration coefficients at first impact from the tank tests of a 1/5.5-size model were in fair agreement with data obtained at the Langley impact basin during tests of a 1/2-size model of the hull.

Clement, Eugene P.↗

Ice/frost detection using millimeter wave radiometry

A series of ice detection tests was performed on the shuttle external tank (ET) and on ET target samples using a 35/95 GHz instrumentation radiometer. Ice was formed using liquid nitrogen and water spray inside a test enclosure containing ET spray on foam insulation samples. During cryogenic fueling operations prior to the shuttle orbiter engine firing tests, ice was formed with freon and water over a one meter square section of the ET LOX tank. Data analysis was performed on the ice signatures, collected by the radiometer, using Georgia Tech computing facilities. Data analysis technique developed include: ice signature images of scanned ET target; pixel temperature contour plots; time correlation of target data with ice present versus no ice formation; and ice signature radiometric temperature statistical data, i.e., mean, variance, and standard deviation.

Gagliano, J. A.↗

Investigation of space shuttle launch vehicle external tank nose configuration effects (model 67-OTS) in the Rockwell International 7 by 7 foot trisonic wind tunnel (IA69)

Wind tunnel aerodynamic investigations were conducted on an 0.015-scale representation of the space shuttle launch configuration. The primary test objectives were to investigate shock wave formation and record the aerodynamic stability and control effects generated by a new external tank nose configuration (MCR 467) at a Mach number of 1.2. Schlieren photographs were taken at angles of attack of -4 deg, 0 deg, and 4 deg, beta = 0 deg with force and pressure data recorded over the alpha range of -4 deg equal to or less than alpha equal to or less than 4 deg at beta = + or - 4 deg. The launch configuration model, consisting of the VL70-00014OA/B Orbiter, the VL78-000041B ET, and the VL77-000036A SRBs, was sting mounted on a 2.5-inch Task type internal balance entering through the ET base region. Wing, body, and base pressure lines for all orifices were routed internally through the model to the sting support system. Parametric variation consisted only of altering the ET nose configuration.

Mennell, R.↗

Rough-water Landings of a 0.1-Size Powered Dynamic Model of the XP5Y-1 Flying Boat with Two Types of Afterbody - Langley Tank Model 228 (TED No. NACA DE309)

A 0.1-size powered dynamic model of a large, high-speed flying boat was landed in Langley tank no. 1 into oncoming waves 4 feet high (full size). The model was tested with two afterbodies of differing lengths (4.12 and 6.63 beams). The short afterbody had a constant angle of dead rise of 22.5deg and a keel angle of 6.5deg. The long afterbody had warped dead rise and a keel angle of 8.5deg. The vertical accelerations were slightly greater and the maximum angular accelerations and maxim= trims were slightly less for the model with the long afterbody than for the model with -the short afterbody. A wave length of 210 feet (full size) imposed the highest accelerations on the model with either the long or the short afterbody.

Garrison, Charlie C.↗

Millimeter Wave Synthetic Aperture Imaging System with a Unique Rotary Scanning System

In recent years, millimeter wave imaging techniques, using synthetic aperture focusing and holographical approaches, have shown tremendous potential for nondestructive testing applications, involving materials and structures used in space vehicles, including the space shuttle external fuel tank spray on foam insulation and its acreage heat tiles. The ability of signals at millimeter wave frequencies (30 - 300 GHz) to easily penetrate inside of low loss dielectric materials, their relatively small wavelengths, and the possibility of detecting coherent (magnitude and phase) reflections make them suitable for high resolution synthetic aperture focused imaging the interior of such materials and structures. To accommodate imaging requirements, commonly a scanning system is employed that provides for a raster scan of the desired structure. However, most such scanners, although simple in design and construction, are inherently slow primarily due to the need to stop and start at the beginning and end of each scan line. To this end, a millimeter wave synthetic aperture focusing system including a custom-designed transceiver operating at 35 - 45 GHz (Q-band) and unique and complex rotary scanner was designed and developed. The rotary scanner is capable of scanning an area with approximately 80 cm in diameter in less than 10 minutes at step sizes of 3 mm and smaller. The transceiver is capable of producing accurate magnitude and phase of reflected signal from the structure under test. Finally, a synthetic aperture focusing algorithm was developed that translates this rotary-obtained magnitude and phase into a synthetic aperture focusing image of inspected structures. This paper presents the design of the transceiver and the rotary scanning system along with showing several images obtained with this system from various complicated structures.

Ghasr, M. T.↗

Development and Short-Range Testing of a 100 kW Side-Illuminated Millimeter-Wave Thermal Rocket

The objective of the phase described here of the Millimeter-Wave Thermal Launch System (MTLS) Project was to launch a small thermal rocket into the air using millimeter waves. The preliminary results of the first MTLS flight vehicle launches are presented in this work. The design and construction of a small thermal rocket with a planar ceramic heat exchanger mounted along the axis of the rocket is described. The heat exchanger was illuminated from the side by a millimeter-wave beam and fed propellant from above via a small tank containing high pressure argon or nitrogen. Short-range tests where the rocket was launched, tracked, and heated with the beam are described. The rockets were approximately 1.5 meters in length and 65 millimeters in diameter, with a liftoff mass of 1.8 kilograms. The rocket airframes were coated in aluminum and had a parachute recovery system activated via a timer and Pyrodex. At the rocket heat exchanger, the beam distance was 40 meters with a peak power intensity of 77 watts per square centimeter. and a total power of 32 kilowatts in a 30 centimeter diameter circle. An altitude of approximately 10 meters was achieved. Recommendations for improvements are discussed.

Bruccoleri, Alexander↗

STS-114: Discovery Return to Flight Imagery Briefing

George Diller, from NASA Public Affairs, introduces Bob Page who is the chairman of the NASA Intercenter Photo Working Group. Page discusses the purpose of the group which is to perform an analysis of all imagery captured of spacecraft launches. He presents charts to discuss return to flight optics. The charts consist of: 1) Overall Shuttle Imagery Plan; 2) Baseline Configuration Imagery; 3) Upgraded Operational Television (OTV) Cameras; 4) Mobile Launch Platform Cameras; 5) Fixed Service Structure Cameras; 6) Kimeto Tracking Mount (KMT); 7) MOTS (Mobile Optical Tracking System); 8) Intermediate Focal Length Optical Tracker (IFLOT); 9) Distant Object Attitude Measurement System (DOAMS); 10) Advanced Transportable Optical Tracking System (ATOTS); 11) STS-114 Pad Fixed Tracker Camera Configuration; 12) STS-114 Camera Medium and Long Range Tracker Configuration; 13) WB-57 Ascent Visualization Experiment (WAVE); 14) WAVE Profile, Plan View, CAD Flight Training, and Test Flight; 15) Minimum STS-114 Flight Cameras Configuration; 16) External Tank (ET) Separation Cameras; 17) ET Imagery; Umbilical and Handheld; 18) On-Orbit Imagery; and 19) Imagery Data Distribution Plan. The presentation ends with a brief question and answer period.

Source record↗

Nonlinear Slosh Damping Testing and Analysis for Launch Vehicle Propellant Tanks

Propellant tank slosh damping models for launch vehicle ascent analysis typically employ linear models for bare-wall damping, or assume a single, low-amplitude wave height for baffled configurations. A higher fidelity damping model would incorporate nonlinear effects to increase damping as slosh wave amplitude increases. This paper provides an overview of a technical assessment performed by the NASA Engineering and Safety Center (NESC) to evaluate lateral slosh damping as a function of lateral force (or wave) amplitude for multiple tank configurations. The increased fidelity of nonlinear slosh damping models, if leveraged, has the potential to reduce over-conservatism associated with the use of linear slosh damping models. This can provide design flexibility to enhance launch vehicle flight control performance, reduce baffle design requirements and/or increase robustness in targeted areas such as control-structure interaction during ascent.

Tannen S VanZwieten↗

High-Resolution Inspection of the Space Shuttle External Tank Spray-on-Foam Insulation (SOFI) using Focused Millimeter Waves at D-Band (150 GHz)

Space Shuttle Columbia's catastrophic failure has been attributed to a piece of spray-on-foam insulation (SOFI) that was dislodged from the external tank and struck the leading edge of the left wing. A piece of SOFI was also dislodged in the recent Space Shuttle Discovery's flight. Clearly, there is a great and urgent need to inspect the external tank SOFI and other similar insulating structures (including the acreage heat tile) in a reliable and robust fashion. In the past two years, millimeter wave nondestructive testing methods, using both real and synthetic focusing techniques, have shown great potential for this purpose. Recently obtained real-focused images from several different and complex SOFI panels have demonstrated the utility of these methods as being viable, robust, repeatable, simple, portable and effective. D-band frequency range which covers a frequency spectrum of 110- 170 GHz is well-suited for this purpose given the nature of the foam which causes significant scattering at much higher frequencies. This paper presents the results of using continuous-wave (CW) reflectometry conducted on several typical and complex SOFI panes at 150 GHz.

Kharkovsky, S.↗