Search NASA⌕ Search

SEARCH · Search NASA

Results for “waveform analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A molecular beam/quadrupole mass spectrometer system with synchronized beam modulation and digital waveform analysis

A performance evaluation is conducted for a molecular beam/mass spectrometer (MB/MS) system, as applied to a 1-30 torr microwave-discharge flow reactor (MWFR) used in the formation of the methylperoxy radical and a study of its subsequent destruction in the presence or absence of NO(x). The modulated MB/MS system is four-staged and differentially pumped. The results obtained by the MWFR study is illustrative of overall system performance, including digital waveform analysis; significant improvements over previous designs are noted in attainable S/N ratio, detection limit, and accuracy.

Pellett, G. L.↗

Waveform Analysis of AE in Composites

Advanced, waveform based acoustic emission (AE) techniques have been developed to evaluate damage mechanisms in the testing of composite materials. This approach, more recently referred to as Modal AE, provides an enhanced capability to discriminate and eliminate noise signals from those generated by damage mechanisms. Much more precise source location can also be obtained in comparison to conventional, threshold crossing arrival time determination techniques. Two successful examples of the application of Modal AE are presented in this work. In the first, the initiation of transverse matrix cracking in cross-ply, tensile coupons was monitored. In these tests, it was documented that the same source mechanism, matrix cracking, can produce widely different AE signal amplitudes dependent on laminate stacking sequence and thickness. These results, taken together with well known propagation effects of attenuation and dispersion of AE signals in composite laminates, cast further doubt on the validity of simple amplitude or amplitude distribution analysis for AE source determination. For the second example, delamination propagation in composite ring specimens was monitored. Pressurization of these composite rings is used to simulate the stresses in a composite rocket motor case. AE signals from delamination propagation were characterized by large amplitude flexural plate mode components which have long signal durations because of the large dispersion of this mode.

Prosser, William H.↗

Waveform analysis for Geosat day 96

A detailed model waveform function has been least-squares-fitted to 10-second averages of waveform sampler data from selected over-ocean portions of day 96 of the Geosat mission. The results confirm that the height corrections already applied in the routine Geosat data processing are generally good to well within 10 centimeters. Additional height corrections are provided that can refine height estimates to within the several-centimeter level.

Hayne, George S.↗

Wallops waveform analysis of SEASAT-1 radar altimeter data

Fitting a six parameter model waveform to over ocean experimental data from the waveform samplers in the SEASAT-1 radar altimeter is described. The fitted parameters include a waveform risetime, skewness, and track point; from these can be obtained estimates of the ocean surface significant waveheight, the surface skewness, and a correction to the altimeter's on board altitude measurement, respectively. Among the difficulties encountered are waveform sampler gains differing from calibration mode data, and incorporating the actual SEASAT-1 sampled point target response in the fitted wave form. There are problems in using the spacecraft derived attitude angle estimates, and a different attitude estimator is developed. Points raised in this report have consequences for the SEASAT-1 radar altimeter's ocean surface measurements are for the design and calibration of radar altimeters in future oceanographic satellites.

Hayne, G. S.↗

Full waveform analysis for high pressure ultrasonic measurement

In this paper we report a data analysis protocol for ultrasonic velocity measurements carried out in a synchrotron x-ray facility based multi-anvil high-pressure apparatus. Synthetic ultrasonic signals for the time period between echoes from the two ends of the sample assembly are created with a few simple parameters as the echo waveform is modeled by the first echo from the anvil-assembly boundary. Each echo is modeled as a delta function with an amplitude and arrival time and convolved with this waveform. The final waveform, fit to the data, enables analysis of signals with overlapped echoes as they are common in small cell assemblies and high pressure.

47 OTHER INSTRUMENTATION↗

computer land use mapping via TV waveform analysis of space photography

An instrumentation and computer system which offers the potential for analyzing photogeographic distributions is described. To satisfy the requirement for computer acceptance, a television and waveform system was developed to transpose pictorial or iconic photo forms to the analytic. A video conversion was accomplished, and each pattern visible on the original photography was represented by a certain range of percentages. With spatial occurrences in digital form, a computer program was developed that could identify, analyze, and map geographic inputs.

Source record↗

A new waveform analysis technique to extract good energy and position resolution from a dual-axis duo-lateral position-sensitive detector

The dual-axis duo-lateral position-sensitive silicon detector was developed to detect charged particles with high quality position and energy resolution. When these detectors were used with conventional signal processing electronics, an empirically determined correction was used to improve energy resolution. In this work, the waveforms from the detector after preamplification are studied in detail to investigate position information contained in the waveforms. A 7.22 MeV/nucleon alpha particle beam was impinged directly on a masked dual-axis duo-lateral detector. Data obtained using a 228 Th alpha particle source was also used. Here, by studying the waveform characteristics that give rise to the position-dependent distortions, a new summed trigger analysis method has been developed to significantly improve linearity in position reconstruction without sacrificing energy resolution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Waveform analysis of a large-area superconducting nanowire single photon detector

Superconducting nanowire single photon detectors (SNSPDs) are typically used as single-mode-fiber-coupled single-pixel detectors, but large area detectors are increasingly critical for applications ranging from microscopy to free-space quantum communications. However, the long meander-line length of such large-area SNSPDs results in a proportionately large kinetic inductance that affects the waveform generated by the device. Here, we explore changes in the rising edge of the readout pulse for a single-pixel large-area SNSPD as a function of the optical spot size on the detector and compare to the rising edge of the dark-count waveform. We observe a bimodal distribution of bright-count rise times and show that the probability of a slow rise time increases in the limit of large spot sizes, indicative of a position sensitive response. Additionally, in the limit of low bias currents, the dark-count readout pulse is most similar to the large spot-size bright-count readout pulse, which suggests that dark counts arise from locations spanning the device. Overall, these results are consistent with a simple model of traveling microwave modes excited by single photons incident at varying positions along the length of the nanowire.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Algorithm Theoretical Basis Document for the Derivation of Range and Range Distributions from Laser Pulse Waveform Analysis for Surface Elevations, Roughness, Slope, and Vegetation Heights

The primary purpose of the GLAS instrument is to detect ice elevation changes over time which are used to derive changes in ice volume. Other objectives include measuring sea ice freeboard, ocean and land surface elevation, surface roughness, and canopy heights over land. This Algorithm Theoretical Basis Document (ATBD) describes the theory and implementation behind the algorithms used to produce the level 1B products for waveform parameters and global elevation and the level 2 products that are specific to ice sheet, sea ice, land, and ocean elevations respectively. These output products, are defined in detail along with the associated quality, and the constraints, and assumptions used to derive them.

Brenner, Anita C.↗

Acoustic Emission Analysis of Damage Progression in Thermal Barrier Coatings Under Thermal Cyclic Conditions

Damage evolution of electron beam-physical vapor deposited (EBVD-PVD) ZrO2-7 wt.% Y2O3 thermal barrier coatings (TBCs) under thermal cyclic conditions was monitored using an acoustic emission (AE) technique. The coatings were heated using a laser heat flux technique that yields a high reproducibility in thermal loading. Along with AE, real-time thermal conductivity measurements were also taken using infrared thermography. Tests were performed on samples with induced stress concentrations, as well as calcium-magnesium-alumino-silicate (CMAS) exposure, for comparison of damage mechanisms and AE response to the baseline (as-produced) coating. Analysis of acoustic waveforms was used to investigate damage development by comparing when events occurred, AE event frequency, energy content and location. The test results have shown that AE accumulation correlates well with thermal conductivity changes and that AE waveform analysis could be a valuable tool for monitoring coating degradation and provide insight on specific damage mechanisms.

calcium-magnesium-alumino-silicate (CMAS)↗

Detection of hidden mineral deposits by airborne spectral analysis of forest canopies

Data from field surveys and biogeochemical tests conducted in Maine, Montana, and Washington strongly correlate with results obtained using high resolution airborne spectroradiometer which detects an anomalous spectral waveform that appears definitely associated with sulfide mineralization. The spectral region most affected by mineral stress is between 550 nm and 750 nm. Spectral variations observed in the field occur on the wings of the red chlorophyll band centered at about 690 nm. The metal-stress-induced variations on the absorption band wing are most successfully resolved in the high spectral resolution field data using a waveform analysis technique. The development of chlorophyll pigments was retarded in greenhouse plants doped with copper and zinc in the laboratory. The lowered chlorophyll production resulted in changes on the wings of the chlorophyll bands of reflectance spectra of the plants. The airborne spectroradiometer system and waveform analysis remains the most sensitive technique for biogeochemical surveys.

Collins, W.↗

Increasing the Upper Mass/Charge Limit of a Quadrupole Ion Trap for Ion/Ion Reaction Product Analysis via Waveform Switching

Quadrupole ion traps (QITs) are versatile platforms for performing experiments with gas-phase ions due to their abilities to store ions of both polarities and to conduct MS{sup n} experiments. The QIT is particularly useful as a reaction cell for ion/ion reactions. In the case of an ion/ion reaction experiment in a QIT, multiply charged reactant ions may initially be of relatively low m/z (e.g., m/z < 1000) whereas the product ions can be one or more orders of magnitude higher in m/z (e.g., m/z > 100,000). Several factors can limit the m/z range over which an ion/ion reaction experiment can be conducted. These include (1) the efficiency of the detector, (2) the m/z range over which oppositely charged ions can be mutually stored, and (3) the m/z range over which ions can be mass selectively ejected into an external detector. High-frequency waveforms provide larger m/z trapping ranges for mutual storage of oppositely charged ions whereas low-frequency waveforms provide better trapping for very high m/z product ions. Presented here is a method that switches from a high-frequency sine wave prior to and during an ion/ion reaction to a low-frequency square wave to eject low m/z reagent ions and improves confinement of the product ions before mass-selective ejection by scanning the frequency of the square wave. This approach addresses the third issue, which is the primary limiting factor with QITs operated at high RF (e.g., > 900 MHz). .

74 ATOMIC AND MOLECULAR PHYSICS↗

Radar Waveform Pulse Analysis Measurement System for High-Power GaN Amplifiers

This work presents a measurement system to characterize the pulsed response of high-power GaN amplifiers for use in space-based SAR platforms that require very strict amplitude and phase stability. The measurement system is able to record and analyze data on three different time scales: fast, slow, and long, which allows for greater detail of the mechanisms that impact amplitude and phase stability. The system is fully automated through MATLAB, which offers both instrument control capability and in-situ data processing. To validate this system, a high-power GaN HEMT amplifier operated in saturation was characterized. The fast time results show that variations to the amplitude and phase are correlated to DC supply transients, while long time characteristics are correlated to temperature changes.

high-power amplifier (HPA)↗