Search NASA⌕ Search

SEARCH · Search NASA

Results for “waveform analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Full waveform analysis for high pressure ultrasonic measurement

In this paper we report a data analysis protocol for ultrasonic velocity measurements carried out in a synchrotron x-ray facility based multi-anvil high-pressure apparatus. Synthetic ultrasonic signals for the time period between echoes from the two ends of the sample assembly are created with a few simple parameters as the echo waveform is modeled by the first echo from the anvil-assembly boundary. Each echo is modeled as a delta function with an amplitude and arrival time and convolved with this waveform. The final waveform, fit to the data, enables analysis of signals with overlapped echoes as they are common in small cell assemblies and high pressure.

47 OTHER INSTRUMENTATION↗

A new waveform analysis technique to extract good energy and position resolution from a dual-axis duo-lateral position-sensitive detector

The dual-axis duo-lateral position-sensitive silicon detector was developed to detect charged particles with high quality position and energy resolution. When these detectors were used with conventional signal processing electronics, an empirically determined correction was used to improve energy resolution. In this work, the waveforms from the detector after preamplification are studied in detail to investigate position information contained in the waveforms. A 7.22 MeV/nucleon alpha particle beam was impinged directly on a masked dual-axis duo-lateral detector. Data obtained using a 228 Th alpha particle source was also used. Here, by studying the waveform characteristics that give rise to the position-dependent distortions, a new summed trigger analysis method has been developed to significantly improve linearity in position reconstruction without sacrificing energy resolution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Waveform analysis of a large-area superconducting nanowire single photon detector

Superconducting nanowire single photon detectors (SNSPDs) are typically used as single-mode-fiber-coupled single-pixel detectors, but large area detectors are increasingly critical for applications ranging from microscopy to free-space quantum communications. However, the long meander-line length of such large-area SNSPDs results in a proportionately large kinetic inductance that affects the waveform generated by the device. Here, we explore changes in the rising edge of the readout pulse for a single-pixel large-area SNSPD as a function of the optical spot size on the detector and compare to the rising edge of the dark-count waveform. We observe a bimodal distribution of bright-count rise times and show that the probability of a slow rise time increases in the limit of large spot sizes, indicative of a position sensitive response. Additionally, in the limit of low bias currents, the dark-count readout pulse is most similar to the large spot-size bright-count readout pulse, which suggests that dark counts arise from locations spanning the device. Overall, these results are consistent with a simple model of traveling microwave modes excited by single photons incident at varying positions along the length of the nanowire.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Increasing the Upper Mass/Charge Limit of a Quadrupole Ion Trap for Ion/Ion Reaction Product Analysis via Waveform Switching

Quadrupole ion traps (QITs) are versatile platforms for performing experiments with gas-phase ions due to their abilities to store ions of both polarities and to conduct MS{sup n} experiments. The QIT is particularly useful as a reaction cell for ion/ion reactions. In the case of an ion/ion reaction experiment in a QIT, multiply charged reactant ions may initially be of relatively low m/z (e.g., m/z < 1000) whereas the product ions can be one or more orders of magnitude higher in m/z (e.g., m/z > 100,000). Several factors can limit the m/z range over which an ion/ion reaction experiment can be conducted. These include (1) the efficiency of the detector, (2) the m/z range over which oppositely charged ions can be mutually stored, and (3) the m/z range over which ions can be mass selectively ejected into an external detector. High-frequency waveforms provide larger m/z trapping ranges for mutual storage of oppositely charged ions whereas low-frequency waveforms provide better trapping for very high m/z product ions. Presented here is a method that switches from a high-frequency sine wave prior to and during an ion/ion reaction to a low-frequency square wave to eject low m/z reagent ions and improves confinement of the product ions before mass-selective ejection by scanning the frequency of the square wave. This approach addresses the third issue, which is the primary limiting factor with QITs operated at high RF (e.g., > 900 MHz). .

74 ATOMIC AND MOLECULAR PHYSICS↗

High event rate analysis technique for the dual-axis duo-lateral position-sensitive silicon detectors of FAUST

The dual-axis duo-lateral (DADL) position-sensitive silicon detector was developed to obtain precise position and energy information for detected charged particles. The Forward Array Using Silicon Technology (FAUST) is currently equipped with 68 DADL detectors backed by CsI(Tl) scintillators for the study of charged particle correlations in heavy-ion collisions where precise position and energy information is essential. When conventional signal processing electronics were used for the DADL detectors, a position dependence of the measured energy as well as distortions in the calculated particle positions were observed. In previous work, waveforms from the detector after preamplification were studied to better understand the features that give rise to these distortions; therein, a waveform analysis technique was developed to improve the energy resolution and linearity in position reconstruction. However, the reading and writing of waveforms for an entire detector array limits data collection rates and adds significant burden in data storage and analysis speed. In this work, the integrators of a Struck SIS3316 ADC were utilized to process 228 Th source data to develop and optimize a new analysis method that captures the benefits of the waveform analysis technique while circumventing the waveform writing requirement. This integrator method – capable of 59 keV (FWHM) energy resolution – was used in the collection of 35 MeV/nucleon 28 Si + 12 C collision data using FAUST to investigate exotic decays of highly excited highly deformed nuclei. In this data, a position resolution of 0.4 mm (FWHM) was obtained for 25 MeV α-particles; for α-particles near this energy that originate from 8 Be ground state decays, a 8 Be ground state width of 30 keV (FWHM) was obtained. The impact of the energy-dependent DADL position resolution emergent from electronic noise on the quality of excited state measurement was modeled and compared to the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model waveform accuracy standards for gravitational wave data analysis

Model waveforms are used in gravitational wave data analysis to detect and then to measure the properties of a source by matching the model waveforms to the signal from a detector. This paper derives accuracy standards for model waveforms which are sufficient to ensure that these data analysis applications are capable of extracting the full scientific content of the data, but without demanding excessive accuracy that would place undue burdens on the model waveform simulation community. These accuracy standards are intended primarily for broadband model waveforms produced by numerical simulations, but the standards are quite general and apply equally to such waveforms produced by analytical or hybrid analytical-numerical methods.

79 ASTRONOMY AND ASTROPHYSICS↗

Remote Instrumentation and Data Acquisition

This poster outlines the development and implementation of a remote data acquisition system for waveform analysis using a Rohde & Schwarz oscilloscope. The project involved capturing waveform data, and transferring it to a local machine for visualization and analysis. The core logic was developed in C++ with a focus on object oriented programming and the use of polymorphism so the main application can interact with any instrument without knowing its exact type, simplifying the overall logic and making it easier to add or swap out components without changing the rest of the codebase.. The system issues Standard Commands for Programmable Instruments (SCPI) via a socket connection and parses the oscilloscope s ASCII waveform data. The C++ application was containerized using Docker for ease of portability, and reproducibility. Emphasis was placed on secure networking practices, error handling, and effective data capture. The report describes the technical steps taken, challenges encountered, and future work, providing insight into the practical integration of hardware interfacing with remote computational environments.

Parikh, Jaymil [Illinois U., Urbana]↗

Remote Instrumentation and Data Acquisition: An Internship Research Report

This report outlines the development and implementation of a remote data acquisition system for waveform analysis using a Rohde & Schwarz oscilloscope. The project involved capturing waveform data, and transferring it to a local machine for visualization and analysis. The core logic was developed in C++ with a focus on object oriented programming and the use of polymorphism so the main application can interact with any instrument without knowing its exact type, simplifying the overall logic and making it easier to add or swap out components without changing the rest of the codebase.. The system issues Standard Commands for Programmable Instruments (SCPI) via a socket connection and parses the oscilloscope’s ASCII waveform data. The C++ application was containerized using Docker for ease of portability, and reproducibility. Emphasis was placed on secure networking practices, error handling, and effective data capture. The report describes the technical steps taken, challenges encountered, and lessons learned, providing insight into the practical integration of hardware interfacing with remote computational environments.

Parikh, Jaymil [Fermilab]↗

Geophysical Monitoring Program Core Seismic Libraries

The Geophysical Monitoring Program Core Seismic Libraries contain a broad array of seismic and waveform analysis libraries useful for a wide range of seismic analysis processes. These include signal processing, travel time calculation, waveform correlation, array processing, geometry and geodesy, and plotting libraries.

Barno, JustinG [Lawrence Livermore National Labora↗

A Traditional Look at SPE Phase 1 Surface Seismic Data: Far-Field Instruments, Measurements, and Analysis

We visually examined surface seismic data from the Source Physics Experiment (SPE) Phase-1 chemical explosions in preparation for waveform analysis and interpretation. Recording stations included far-field (near source) geophone lines, and both permanent network, reoccupied USArray, and temporary stations at local and regional distances. We found that near-source waveforms are dominated by broad band compressional (P), and band limited surface wave (Rg) (< 10 Hz) phases. Distinct, consistent shear (S) phases are difficult to observe visually even with a comprehensive bank of frequency bands. Secondary phases are indistinct at near-local distances, unlike for earthquake sources, especially at the high frequencies of interest for discrimination (e.g. 4-8 Hz), likely due to intense near surface scattering. S phases begin to emerge from the scattered background at and beyond 100 km. We identified regional Pn, Pg and Lg phases to 446 km for SPE-5. The data set is, unfortunately, plagued by poorly recorded instrument responses, or, possibly, time varying site amplification due to human interaction with sensors. Instrument response issues should be fixable, and this should be attempted to make this a truly, high-quality data set for use by the monitoring community.

58 GEOSCIENCES↗