Search NASA⌕ Search

SEARCH · Search NASA

Results for “wearable electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of Flexible Energy Storage Device for Wearable Electronics using All-organic Composites

As the demands and applications of wearable electronics increase, the need of power supply for wearable electronics becomes the critical issue. Both batteries and capacitors can be used as power supplier. In terms of energy storage device, capacitors have many advantages over the batteries, but have a lower energy storage density. To improve the energy density, composites, in which inorganic particles are embedded in a polymer matrix, have been identified as a promising approach to create the dielectrics with a higher energy storage density. The physics behind the composite approach is that the inorganics have a higher dielectric constant and polymers can stand with a higher electric field so that the composites can exhibit a relative dielectric constant and stand with a relative electric field. Therefore, the composites can exhibit a higher energy storage density. However, the embedment of inorganic particles into polymer severely reduces the flexibility of the polymer. To develop flexible energy storage ultracapacitors as an energy storage device for wearable electronics, an all-organic composite approach, in which a dielectric polymer is mixed with polar organic molecules, is introduced. It is experimentally found that by adding a small amount of polar organic molecules into dielectric polymers, the polymers exhibits a high dielectric constant and can stand with a higher electric field. More importantly, the flexibility of the all-organic composites is better than the polymer matrix. Therefore, the all-organic composites can be a strong and promising candidate for the development of flexible energy storage devices for the wearable electronics. In this study, three different dielectric polymers and three different polar molecules were studied. All the all-organic composite systems exhibit a significant improvement on the energy storage density. These new flexible energy storage devices are being developed to be fabricated with on-demandadditive electronics manufacturing processes, so that they can be fabricated when needed in space on the International Space Station and planned lunar habitat and other future missions. These flexible energy storage devices will provide the storage in concert with other printed power generation devices to allow crew health and structural health monitoring sensor devices and systems to be self-powered, not requiring any external power or batteries.

energy storage↗

Perspectives from the Wearable Electronics and Applications Research (WEAR) Lab, NASA Johnson Space Center

As NASA moves beyond exploring low earth orbit and into deep space exploration, increased communication delays between astronauts and earth drive a need for crew to become more autonomous (earth-independent). Currently crew on board the International Space Station (ISS) have limited insight into specific vehicle system performance because of the dependency on monitoring and real-time communication with Mission Control. Wearable technology provides a method to bridge the gap between the human (astronaut) and the system (spacecraft) by providing mutual monitoring between the two. For example, vehicle or environmental information can be delivered to astronauts through on-body devices and in return wearables provide data to the spacecraft regarding crew health, location, etc. The Wearable Electronics and Applications Research (WEAR) Lab at the NASA Johnson Space Center utilizes a collaborative approach between engineering and human factors to investigate the use of wearables for spaceflight. Zero and partial gravity environments present unique challenges to wearables that require collaborative, user-centered, and iterative approaches to the problems. Examples of the WEAR Lab's recent wearable projects for spaceflight will be discussed.

Moses, Haifa R.↗

Perspectives from the Wearable Electronics and Applications Research (WEAR) Lab, NASA, Johnson Space Center

As NASA moves beyond exploring low earth orbit and into deep space exploration, increased communication delays between astronauts and earth drive a need for crew to become more autonomous (earth-independent). Currently crew on board the International Space Station (ISS) have limited insight into specific vehicle system performance because of the dependency on monitoring and real-time communication with Mission Control. Wearable technology provides a method to bridge the gap between the human (astronaut) and the system (spacecraft) by providing mutual monitoring between the two. For example, vehicle or environmental information can be delivered to astronauts through on-body devices and in return wearables provide data to the spacecraft regarding crew health, location, etc. The Wearable Electronics and Applications Research (WEAR) Lab at the NASA Johnson Space Center utilizes a collaborative approach between engineering and human factors to investigate the use of wearables for spaceflight. Zero and partial gravity environments present unique challenges to wearables that require collaborative, user-centered, and iterative approaches to the problems. Examples of the WEAR Lab's recent wearable projects for spaceflight will be discussed.

Moses, Haifa R.↗

Multifunctional Silk Fibroin Hydrogels with Strong Adhesion for Tissue Sealing and Wearable Electronic Sensors

Multifunctional hydrogels with excellent adhesion, biodegradability, and conductivity are essential for overcoming the obstacles of postoperative secondary injury, flexible sensing instability, and so on. Herein, we develop a multifunctional silk fibroin (SF) hydrogel modified with poly(acrylic acid). Owing to the stable chemical cross-linking network and the abundant carboxylic acid groups of the SF network, the SF hydrogel exhibits a high tensile strength of 74.34 kPa due to sufficient cohesion and interfacial interactions. Additionally, the tensile strain reaches a maximum of 414.6%, the compressive strength is 0.9 MPa, and the shear adhesive strength for pig skin tissues is as high as 64 kPa. Compared with most hydrogels, our multifunctional SF hydrogel with a low swelling ratio provides excellent adhesion, biodegradation, and conductivity, which shows advantages in terms of invasive tissue sealing. Furthermore, the use of self-adhesive SF hydrogels as conductive hydrogels in flexible sensors also benefits the collection of physiological electricity and human motion signals in the field of wearable and implantable electronic devices.

adhesive↗

Stretchable and wearable polymeric heaters and strain sensors fabricated using liquid metals

Wearable electronic devices (WEDs) are receiving significant attention because of the increasing interest in soft robotics, electronic skin, and wearable sensors. Liquid metals (LMs) are compelling for WEDs owing to their metallic conductivity, fluidic nature, and low toxicity. For this study, we fabricated stretchable and soft WEDs using LM (eutectic gallium-indium alloy) wires (LMWs) patterned via force wetting through custom-made stencils on an elastic substrate. LMWs can generate thermal energy via Joule heating upon current application and deliver it to the substrate, resulting in wearable polymeric heaters. The LM mixed with carbonyl iron particles (CIPs) can also be patterned while preserving fluidic behavior. The degree of thermal energy generated through the LMWs can be manipulated as a function of the CIP concentration in the LM and geometrical factors of the electrode patterns, i.e., width and length. An elastic film patterned with LMWs attached to the human body exhibits changes in the effective electrical resistance depending on applied strain, demonstrating potential as a wearable strain sensor. This LM utilized WED that can generate thermal energy upon current application through the LMWs and detect the bodily motion has significant potential for application in wearable thermotherapy, electronic skin, and soft sensors.

47 OTHER INSTRUMENTATION↗

Elastomeric Sensing of Pressure with Liquid Metal and Wireless Inductive Coupling

This project describes resistance-based soft sensors filled with liquid metal, which permit measurements of large strains (0 percent to 110 percent), associated with small forces of less than 30 Newtons. This work also demonstrates a methodology for wireless transfer of these strain measurements without connected electrodes. These sensors allow intermittent detection of pressure on soft membranes with low force. Adapting these sensors for passive wireless pressure sensing will eliminate the need for embedded batteries, and will allow the sensors to transmit pressure data through non-conductive materials including glass and acrylic. The absence of batteries allows us to embed these sensors into materials for long-term use because the sensors only use passive analog circuit elements. We found the oxidation of the liquid metal (eutectic gallium indium) plays a role in the repeatability of the soft sensors. We investigated how the oxidation layer affected the behavior of the sensor by encapsulating materials (silicone, fluorosilicone, and PVC) with varied permeabilities to oxygen. We measured the effects of mechanical loading on the oxidation layer and the effects of wireless inductive coupling on the oxidation layer. We concluded our research by investigating the effects of embedding self-resonant circuits into polydimethylsiloxane (PDMS). Efforts to design engineered systems with soft materials are a growing field with progress in soft robotics, epidermal electronics, and wearable electronics. In the field of soft robotics, PDMS-based grippers are capable of picking up delicate objects because their form-fitting properties allow them to conform to the shape of objects more easily than conventional robotic grippers. Epidermal devices also use PDMS as a substrate to hold electronic components such as radios, sensors, and power supply circuits. Additionally, PDMS-based soft sensors can monitor human motion with liquid metal embedded within micro-channels. Passive wireless sensors have applications in structural health monitoring and medical health monitoring. Doctors can take wireless blood pressure measurements inside arteries to monitor the progression of heart disease. Glaucoma patients can use this technology to monitor the pressure in their eyes to track the progression of the disease.

Dick, Jacob↗

Mechanical, Morphological, and Charge Transport Properties of NDI Polymers with Variable Built‐in Π‐Conjugation Lengths Probed by Simulation and Experiment

Abstract Mechanically deformable polymeric semiconductors are a key material for fabricating flexible organic thin‐film transistors (FOTFTs)—the building block of electronic circuits and wearable electronic devices. However, for many π‐conjugated polymers achieving mechanical deformability and efficient charge transport remains challenging. Here the effects of polymer backbone bending stiffness and film microstructure on mechanical flexibility and charge transport are investigated via experimental and computational methods for a series of electron‐transporting naphthalene diimide (NDI) polymers having differing extents of π‐conjugation. The results show that replacing increasing amounts of the π‐conjugated comonomer dithienylvinylene (TVT) with the π‐nonconjugated comonomer dithienylethane (TET) in the backbone of the fully π‐conjugated polymeric semiconductor, PNDI‐TVT 100 (yielding polymeric series PNDI‐TVT x , 100 ≥x≥ 0), lowers backbone rigidity, degree of texturing, and π–π stacking interactions between NDI moieties. Importantly, this comonomer substitution increases the mechanical robustness of PNDI‐TVT x while retaining efficient charge transport. Thus, reducing the TVT content of PNDI‐TVT x suppresses film crack formation and dramatically stabilizes the field‐effect electron mobility upon bending (e.g., 2 mm over 2000 bending cycles). This work provides a route to tune π–π stacking in π‐conjugated polymers while simultaneously promoting mechanical flexibility and retaining good carrier mobility in FOTFTs.

Chemistry↗

A Perspective on Multi-Source Energy Harvesting Technology Using Piezoelectric and Thermoelectric Materials

Energy harvesting using various locally available energy sources such as vibration energy, heat, sound, or magnetic field have become attractive topics for supplying power to modular electronic devices making them run independently in extreme environments. In this paper, we will be discussing the perspectives on thermoelectric (TE) and piezoelectric materials and devices, and then the concept of multi-source energy harvester using piezoelectric and thermoelectric devices and integration of them into a reliable and independent power source. TE materials having low thermal conductivity and high figure-of-merit ( zT ) are developed to convert even a small temperature gradient efficiently into electrical energy with the state-of-the-art conversion efficiency of ~15% and output power of ~56 W from single device. The piezoelectric device architecture is configured using high performance piezoelectric ceramics (Cu-Mn-PIN-PMN-PT). These ceramics exhibit high piezoelectric coefficient with high mechanical quality factor and low dielectric loss factor. Using these piezoelectric materials, power density as high a 2 mW/cm 2 is demonstrated in 1-1.5 g vibration environments. The piezoelectric device is attached on the surface of TE module to capture both the vibration and thermal energy sources to realize dual mode energy harvester. The multi-energy transfer strategy opens opportunities for a future generation of wireless and modular electronic devices. These devices would be useful in powering wearable electronic devices, micro sensor chargers, etc. in extreme environmental conditions using body heat/thermal sources and induced motion/vibrations.

Piezoelectric↗

Ultra-Thin, Flexible Electronics

Thinned die can be used to realize ultra-thin flexible electronics for applications such as conformal and wearable electronics. Three techniques have been developed to achieve this goal using thinned die: die flip chip bonded onto flexible substrates, die laminated onto LCP films, and die embedded in polyimide. A key to achieving each of these techniques is the thinning of die to a thickness of 50 microns or thinner. Conventional CMP processing can be used to thin to 50 microns. At 50 microns, the active die become flexible and must be handled by temporarily bonding them to a holder die, for further processing. Once bonded face down to the holder die, the active die can be further thinned by DRIE etching the exposed backside. The thinned die can then been packaged in or on the flexible substrate.

electronics packaging↗

Dry electrodes with a printed cellulose–graphene ink for low-profile strain sensors in electromyography

Dihydrolevoglucosenone, commonly known as Cyrene, is a renewable and fully biodegradable cellulose-waste derived, environmentally friendly solvent, presenting a non-toxic alternative to N-methyl-2-pyrrolidone (NMP). Currently, solution-based processing of graphene and other similar van der Waals solids favor toxic solvents such as NMP, limiting their use for biosensing. However, with the use of Cyrene, bio-compatible printable devices are possible, and studies have already demonstrated its use in temperature and other biosensing methods through screen-printing. Screen-printing unfortunately often requires masks that constrain the minimum acquirable feature size to be above hundreds of centimeters and wastes material, adding to process complexity and cost. Conversely, inkjet-printing is an attractive alternative for the maskless patterning of hierarchically assembled structures, with micron length scales attainable. Graphene's high conductivity positions it ideally for long-wear sensors such as dry electrodes or respiration monitors. Here, we demonstrate the potential of Cyrene-based graphene inks through few-layer inkjet printing on flexible substrates for the first time, to produce non-toxic conductors toward a strain-mediated mechanism for biosensing, used to detect bodily motion for wearable electronics. The challenges overcome in this study include engineering ink chemistry and printing parameters such that Cyrene's relatively high viscosity compared to typical inkjet solvents, still allows for droplet ejection in a conventional material printer, yielding well-resolved clean line-edges in contrast to other solvents that exhibit diffuse line-edges possibly from stray droplets and ink-splashing. Temperature-dependent transport measurements on the inkjet-printed Cyrene-based graphene films showed the conductivity to be largely temperature-invariant but at lower temperatures below 100 K, conductivity decreased, likely as a result of increased inter-membrane separation arising from thermal contraction. Additionally, temperature-dependent Raman spectroscopy showed the red-shift in the G-band, 2D-band and D-band peaks, as temperature increased. As a result, by validating flexion motion detection of the proximal interphalangeal joint demonstrated in this study, our work is the first of its kind to successfully additively manufacture inkjet-printed Cyrene-based graphene strain sensors on flexible substrates for bio-sensing and wearables.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Charge Carrier Induced Structural Ordering And Disordering in Organic Mixed Ionic Electronic Conductors

Operational stability underpins the successful application of organic mixed ionic-electronic conductors (OMIECs) in a wide range of fields, including biosensing, neuromorphic computing, and wearable electronics. Here in this work, both the operation and stability of a p-type OMIEC material of various molecular weights are investigated. Electrochemical transistor measurements reveal that device operation is very stable for at least 300 charging/discharging cycles independent of molecular weight, provided the charge density is kept below the threshold where strong charge–charge interactions become likely. When electrochemically charged to higher charge densities, an increase in device hysteresis and a decrease in conductivity due to a drop in the hole mobility arising from long-range microstructural disruptions are observed. By employing operando X-ray scattering techniques, two regimes of polaron-induced structural changes are found: 1) polaron-induced structural ordering at low carrier densities, and 2) irreversible structural disordering that disrupts charge transport at high carrier densities, where charge–charge interactions are significant. These operando measurements also reveal that the transfer curve hysteresis at high carrier densities is accompanied by an analogous structural hysteresis, providing a microstructural basis for such instabilities. This work provides a mechanistic understanding of the structural dynamics and material instabilities of OMIEC materials during device operation.

36 MATERIALS SCIENCE↗

High Mobility, High Carrier Density SnSe 2 Field‐Effect Transistors with Ultralow Subthreshold Swing and Gate‐Controlled Photoconductance Switching

2D and layered semiconductors are considered as promising electronic materials, particularly for applications that require high carrier mobility and efficient field-effect switching combined with mechanical flexibility. To date, however, the highest mobility has been realized primarily at low carrier concentration. Here, it is shown that few-layer/multilayer SnSe 2 gated by a solution top gate combines very high room-temperature electron mobility (up to 800 cm 2 V −1 s −1 ), along with large on-off current ratios (>10 5 ) and a subthreshold swing below the thermodynamic limit (50 mV per decade) in field-effect devices, at exceptionally large sheet carrier concentrations of ≈10 13 cm −2 . Observed mobility enhancements upon partial depletion of the channel point to near-surface defects or impurities as the mobility-limiting scattering centers. Under illumination, the resulting gap states give rise to gate-controlled switching between positive and negative photoconductance. The results qualify SnSe 2 as a promising layered semiconductor for flexible and wearable electronics, as well as for the realization of advanced approaches to photodetection.

36 MATERIALS SCIENCE↗

Dielectric Engineering of ZnO@ZIF‐8 for High‐Performance Triboelectric Nanogenerators and Self‐Powered Humidity Sensors

Porous metal oxide–metal-organic framework (MO x @MOF) hybrids offer synergistic effects that enhance surface charge density, electronic structure, and textural properties, making them ideal for self-powered sensing applications. Here, uniform, and pinhole-free ternary porous ZnO–PTFE@ZIF-8 hybrid films are developed on room-temperature co-sputtered ZnO–polytetrafluoroethylene (PTFE) composite films, where ZnO serves as a self-sacrificial precursor to precisely regulate ZIF-8 (Zn-MeIm 2 ) growth through solvothermal methods. The resulting TENG achieves a high output power density of 0.67 mW cm −2 , attributed to the synergistic effects of fluorine-rich PTFE and methyl-functionalized ZIF-8, which enhance surface charge density and dielectric response. By tuning PTFE content in the ZnO–PTFE composite, the dielectric constant and triboelectric output is optimized. The ZP60@ZIF-8-based device also demonstrates excellent humidity sensing performance, with a wide detection range (20–99% RH) and ultrahigh sensitivity (R V % of 19 900%, R I % of 19 325% at 99% RH). These results position ZP@ZIF-8-based TENGs as promising platforms for next-generation self-powered sensors and smart wearable electronics.

42 ENGINEERING↗

Vertical organic electrochemical transistors for complementary circuits

Abstract Organic electrochemical transistors (OECTs) and OECT-based circuitry offer great potential in bioelectronics, wearable electronics and artificial neuromorphic electronics because of their exceptionally low driving voltages (<1 V), low power consumption (<1 µW), high transconductances (>10 mS) and biocompatibility 1–5 . However, the successful realization of critical complementary logic OECTs is currently limited by temporal and/or operational instability, slow redox processes and/or switching, incompatibility with high-density monolithic integration and inferior n-type OECT performance 6–8 . Here we demonstrate p- and n-type vertical OECTs with balanced and ultra-high performance by blending redox-active semiconducting polymers with a redox-inactive photocurable and/or photopatternable polymer to form an ion-permeable semiconducting channel, implemented in a simple, scalable vertical architecture that has a dense, impermeable top contact. Footprint current densities exceeding 1 kA cm −2 at less than ±0.7 V, transconductances of 0.2–0.4 S, short transient times of less than 1 ms and ultra-stable switching (>50,000 cycles) are achieved in, to our knowledge, the first vertically stacked complementary vertical OECT logic circuits. This architecture opens many possibilities for fundamental studies of organic semiconductor redox chemistry and physics in nanoscopically confined spaces, without macroscopic electrolyte contact, as well as wearable and implantable device applications.

Science & Technology - Other Topics↗