Search NASA⌕ Search

SEARCH · Search NASA

Results for “wearable sensor data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Robustness of topological persistence in knowledge distillation for wearable sensor data

Topological data analysis (TDA) has shown great success in various applications involving wearable sensor data. However, there are difficulties in leveraging topological features in machine learning and wearable sensors because of the large time consumption and computational resources required to extract the features. To address this problem, knowledge distillation (KD) is utilized to generate a small model and accommodate topological features with persistence image (PI) representations from the raw time series data. Deploying topological knowledge in KD enables the student to achieve better performance compared to the one trained solely on raw time series data. However, it is not yet known if there are coherent characteristics for topological features in PI, which can aid in improving the performance during KD. In this paper, we investigate the suitability and challenges of utilizing topological features in KD for wearable sensor data, thereby contributing to the advancement of the field. Our study explores the impact of transferred topological features by comparing the Teacher-to-Student framework with Multiple Teachers-to-Student where teachers utilize both time series data and persistence images obtained by TDA as inputs. Additionally, we conduct a rigorous examination of topological knowledge effects by testing under various corruptions, knowledge types, and learning strategies in the context of human activity recognition tasks. Our analysis of topological features in KD presents the optimal strategy for incorporating these features. This study includes datasets of varying scales, window lengths, and activity classes, providing a comprehensive evaluation. Our results demonstrate that leveraging topological features in KD to enhance performance across databases.

97 MATHEMATICS AND COMPUTING↗

Functional Data Analysis in Wearable Body Sensor Networks

Improving response time of indirect room-size calorimeters is still an outstanding problem in metabolic research. Accurate estimates of instantaneous rates of gaseous exchange require numerical differentiation of measured gaseousgas concentrations. We propose a new method to estimate the instantaneous gaseousgas exchange rates in indirect calorimetry. In contrast to the previously developed techniques, the method addresses the problem of differentiation of gaseous concentrations as an ill-posed problem. By applying the method of regularization, the problem of differentiation is converted into a well-posed problem resulting in smooth and consistent gaseous exchange rates. The validity of the method is tested on a large dataset of calorimeter experiments which included 313 human experiments along with 231 alcohol combustion experiments. It is demonstrated that the method is able to reliably differentiate between the “unphysiological” process of alcohol combustion and physiological variations produced by human metabolism. The method also allowed unraveling the previously unreported relative kinetics of O2 consumption and Respiratory Quotient (RQ) in humans. It was found that the kinetics of oxidative fuel selection lags behind the energy expenditure in humans exhibiting some sort of oxidative inertia. The time lag varies from 2-3 min up to 30 min, depending on particular individual. No such lag was found in alcohol combustion experiments. In addition to the relative kinetics of substrate oxidation, two statistical indexes reflecting variability of minute-by-minute RQ were estimated. The indexes were the RQ’s standard deviation and RQ’s first-order derivative. Both indexes showed statistically significant difference between human experiments and alcohol combustion experiments. We conclude that the proposed method can consistently extract physiologically-relevant information from noisy calorimetry data and the aforesaid information can provide additional insights into the mechanism of metabolic fuel selection in humans.

54 ENVIRONMENTAL SCIENCES↗

Functional Data Analysis in Wearable Body Sensor Networks

Improving response time of indirect room-size calorimeters is still an outstanding problem in metabolic research. Accurate estimates of instantaneous rates of gaseous exchange require numerical differentiation of measured gaseousgas concentrations. We propose a new method to estimate the instantaneous gaseousgas exchange rates in indirect calorimetry. In contrast to the previously developed techniques, the method addresses the problem of differentiation of gaseous concentrations as an ill-posed problem. By applying the method of regularization, the problem of differentiation is converted into a well-posed problem resulting in smooth and consistent gaseous exchange rates. The validity of the method is tested on a large dataset of calorimeter experiments which included 313 human experiments along with 231 alcohol combustion experiments. It is demonstrated that the method is able to reliably differentiate between the “unphysiological” process of alcohol combustion and physiological variations produced by human metabolism. The method also allowed unraveling the previously unreported relative kinetics of O2 consumption and Respiratory Quotient (RQ) in humans. It was found that the kinetics of oxidative fuel selection lags behind the energy expenditure in humans exhibiting some sort of oxidative inertia. The time lag varies from 2-3 min up to 30 min, depending on particular individual. No such lag was found in alcohol combustion experiments. In addition to the relative kinetics of substrate oxidation, two statistical indexes reflecting variability of minute-by-minute RQ were estimated. The indexes were the RQ’s standard deviation and RQ’s first-order derivative. Both indexes showed statistically significant difference between human experiments and alcohol combustion experiments. We conclude that the proposed method can consistently extract physiologically-relevant information from noisy calorimetry data and the aforesaid information can provide additional insights into the mechanism of metabolic fuel selection in humans.

60 - APPLIED LIFE SCIENCES↗

Optimizing Individualized Treatment Planning for Parkinson’s Disease Using Deep Reinforcement Learning

More than one million people currently live with Parkinson's Disease (PD) in the U.S. alone. Medications, such as levodopa, can help manage PD symptoms. However, medication treatment planning is generally based on patient history and limited interaction between physicians and patients during office visits. This limits the extent of benefit that may be derived from the treatment as disease/patient characteristics are generally non-stationary. Wearable sensors that provide continuous monitoring of various symptoms, such as bradykinesia and dyskinesia, can enhance symptom management. However, using such data to overhaul the current static medication treatment planning approach and prescribe personalized medication timing and dosage that accounts for patient/care-giver/physician feedback/preferences remains an open question. We develop a model to prescribe timing and dosage of medications, given the motor fluctuation data collected using wearable sensors in real-time. We solve the resulting model using deep reinforcement learning (DRL). The prescribed policy determines the optimal treatment plan that minimizes patient's symptoms. Our results show that the model-prescribed policy outperforms the static a priori treatment plan in improving patients' symptoms, providing a proof-of-concept that DRL can augment medical decision making for treatment planning of chronic disease patients.

Watts, Jeremy↗

Efficient human activity recognition with spatio-temporal spiking neural networks

In this study, we explore Human Activity Recognition (HAR), a task that aims to predict individuals' daily activities utilizing time series data obtained from wearable sensors for health-related applications. Although recent research has predominantly employed end-to-end Artificial Neural Networks (ANNs) for feature extraction and classification in HAR, these approaches impose a substantial computational load on wearable devices and exhibit limitations in temporal feature extraction due to their activation functions. To address these challenges, we propose the application of Spiking Neural Networks (SNNs), an architecture inspired by the characteristics of biological neurons, to HAR tasks. SNNs accumulate input activation as presynaptic potential charges and generate a binary spike upon surpassing a predetermined threshold. This unique property facilitates spatio-temporal feature extraction and confers the advantage of low-power computation attributable to binary spikes. We conduct rigorous experiments on three distinct HAR datasets using SNNs, demonstrating that our approach attains competitive or superior performance relative to ANNs, while concurrently reducing energy consumption by up to 94%.

60 APPLIED LIFE SCIENCES↗

Optimizing Patient-Specific Medication Regimen Policies Using Wearable Sensors in Parkinson’s Disease

Effective treatment of Parkinson’s disease (PD) is a continual challenge for healthcare providers, and providers can benefit from leveraging emerging technologies to supplement traditional clinic care. We develop a data-driven reinforcement learning (RL) framework to optimize PD medication regimens through wearable sensors. We leverage a data set of n = 26 PD patients who wore wrist-mounted movement trackers for two separate six-day periods. Using these data, we first build and validate a simulation model of how individual patients’ movement symptoms respond to medication administration. We then pair this simulation model with an on-policy RL algorithm that recommends optimal medication types, timing, and dosages during the day while incorporating human-in-the-loop considerations on medication administration. The results show that the RL-prescribed medication regimens outperform physicians’ medication regimens, despite physicians having access to the same data as the RL agent. To validate our results, we assess our wearable-based RL medication regimens using n = 399 PD patients from the Parkinson’s Progression Markers Initiative data set. We show that the wearable-based RL medication regimens would lead to significant symptom improvement for these patients, even more so than training RL policies directly from this data set. In doing so, we show that RL models from even small data sets of wearable data can offer novel, generalizable clinical insights and medication strategies, which may outperform those derived from larger data sets without wearable data.

60 APPLIED LIFE SCIENCES↗

Improving Medication Regimen Recommendation for Parkinson’s Disease Using Sensor Technology

Parkinson’s disease medication treatment planning is generally based on subjective data obtained through clinical, physician-patient interactions. The Personal KinetiGraph™ (PKG) and similar wearable sensors have shown promise in enabling objective, continuous remote health monitoring for Parkinson’s patients. In this proof-of-concept study, we propose to use objective sensor data from the PKG and apply machine learning to cluster patients based on levodopa regimens and response. The resulting clusters are then used to enhance treatment planning by providing improved initial treatment estimates to supplement a physician’s initial assessment. We apply k-means clustering to a dataset of within-subject Parkinson’s medication changes—clinically assessed by the MDS-Unified Parkinson’s Disease Rating Scale-III (MDS-UPDRS-III) and the PKG sensor for movement staging. A random forest classification model was then used to predict patients’ cluster allocation based on their respective demographic information, MDS-UPDRS-III scores, and PKG time-series data. Clinically relevant clusters were partitioned by levodopa dose, medication administration frequency, and total levodopa equivalent daily dose—with the PKG providing similar symptomatic assessments to physician MDS-UPDRS-III scores. A random forest classifier trained on demographic information, MDS-UPDRS-III scores, and PKG time-series data was able to accurately classify subjects of the two most demographically similar clusters with an accuracy of 86.9%, an F1 score of 90.7%, and an AUC of 0.871. A model that relied solely on demographic information and PKG time-series data provided the next best performance with an accuracy of 83.8%, an F1 score of 88.5%, and an AUC of 0.831, hence further enabling fully remote assessments. These computational methods demonstrate the feasibility of using sensor-based data to cluster patients based on their medication responses with further potential to assist with medication recommendations.

59 BASIC BIOLOGICAL SCIENCES↗

Earth-Independent Medical Operations (EIMO) Concept of Operations

In contrast to the current crew health paradigm for low-Earth orbit and Lunar missions, which depends on real-time communication with Mission Control, deep-space exploration missions will require a significant shift in medical operations. This shift is driven by the constraints of operating at a considerable distance from Earth, such as resource limitations—lack of resupply, restricted mass, power, volume, and data—as well as communication delays and the inability to evacuate back to Earth during emergencies. To move toward a more self-reliant medical model, a strategy is needed to gradually increase space-based crew autonomy and reduce risks to mission success in the challenging environment of deep space. This transformative change, known as "Earth-Independent Medical Operations" (EIMO), explores the gradual transfer of medical care and decision-making from Earth-based support to space-based systems. The goal of this transition is to enhance astronaut health and performance while minimizing mission risks. EIMO requires the development of a medical system that integrates seamlessly with mission planning, vehicle and spacesuit design, and data architecture. This integration is crucial for building a robust medical infrastructure that not only safeguards astronaut well-being but also ensures overall mission success. The Human Research Program (HRP) Exploration Medical Capability (ExMC) Element has revised the EIMO model-based Concept of Operations (ConOps) which outlines an initial vision for EIMO. The ConOps, which is built on the stakeholders’ need, system goals, and objectives (NGOs), presents an array of in-mission scenarios that span a wide range of medical conditions demonstrating the system’s capabilities from basic to complex events. Developed by a multidisciplinary team of systems engineers, scientists, and clinicians within ExMC, the ConOps revision includes two new scenarios(Barotrauma and Self-Medical Management and Behavioral Health and Chronic Medical Care), and implementation of findings from EIMO technical interchange meetings that focused on data and training. The envisioned EIMO Medical System (MS) operates as a system of systems, gathering data from various sources such as reference databases, real-time wearable sensors, point-of-care diagnostics, and environmental controls. The MS also incorporates advanced training tools to support autonomous medical care, assisting the Crew Medical Officer (CMO) during medical events where Ground Support is either unavailable or communication-delayed beyond practicality. Furthermore, MS functions and capabilities were decomposed from the scenarios to establish foundational requirements for EIMO and traced to the NASA Spaceflight Human-System Standard(NASA-STD-3001, Volumes 1 and 2). These traces were performed to gain insights on the alignment of EIMO requirements with the NASA standard. This work serves as an initial recommendation to increase crew autonomy gradually and safely for Mars missions and future deep-space exploration.

medical system↗

2010-2012 California Household Travel Survey

The 2010-2012 California Household Travel Survey (CHTS) was administered by the California Department of Transportation, which collected demographic and travel behavior characteristics for residents across the entire state. At the time, it was the largest such regional or statewide survey ever conducted in the United States. Detailed travel behavior information was obtained from more than 42,500 households via multiple data-collection methods, including computer-assisted telephone interviewing, online and mail surveys, wearable (7,574 participants) and in-vehicle (2,910 vehicles) global positioning system devices, and on-board diagnostic sensors that gathered data directly from a vehicle's engine. Details of personal travel behavior were gathered within the region of residence, inter-regionally within the state, and in adjoining states and Mexico. The survey sampling plan was designed to ensure an accurate representation of the entire population of the state. The CHTS included additional features, such as vehicle-acquisition decisions, parking choices, work schedules and flexibility, use of toll lanes/priced facilities, and walk and bicycle trips, to support advanced model development.

1Hz data↗

Wearable Health Monitoring Systems

The shrinking size and weight of electronic circuitry has given rise to a new generation of smart clothing that enables biological data to be measured and transmitted. As the variation in the number and type of deployable devices and sensors increases, technology must allow their seamless integration so they can be electrically powered, operated, and recharged over a digital pathway. Nyx Illuminated Clothing Company has developed a lightweight health monitoring system that integrates medical sensors, electrodes, electrical connections, circuits, and a power supply into a single wearable assembly. The system is comfortable, bendable in three dimensions, durable, waterproof, and washable. The innovation will allow astronaut health monitoring in a variety of real-time scenarios, with data stored in digital memory for later use in a medical database. Potential commercial uses are numerous, as the technology enables medical personnel to noninvasively monitor patient vital signs in a multitude of health care settings and applications.

Bell, John↗

Summary of Technical Interchange Meetings (TIMs) Designed to Enable Earth Independent Medical Operations (EIMO)

The Exploration Medical Capability Element (ExMC) in NASA’s Human Research Program hosted a series of TIMs in 2023-2024 designed to stimulate discussion around specific topics with the goal of enabling EIMO. In context of the thematic constituent elements of EIMO, namely pre-mission planning, acute/emergent/prolonged medical decision making, supply/resource management and task load management, subject matter experts from industry, academia and government (NASA and other Agencies) provided valuable and actionable guidance and recommendations. Earth-based medical experts will remain indispensable for pre-mission planning, however, management of acute/emergent medical contingencies will require a gradual transition of medical care and decision making from terrestrial to space-based assets to enable support of astronaut health and performance and reduce overall mission risk. Key to achieving these enhancements is providing an integrated data system platform capable of utilizing multiple data streams in concert with a variety of on-board databases and passive monitoring of video and wearable sensors to enable a multi-modal, agentic AI-based clinical decision support system (CDSS) to support crew medical officer (CMO) medical decision-making. The EIMO series of TIMs (I-V) have proven to be instructive and portend a significant paradigm shift will be necessary to maintain crew health and performance on exploration class missions. Importantly, since the expected paradigm shift will be significantly different from the methods of operation that have been employed for the majority of missions from the inception of human spaceflight to date, any proposed methods must be deployed in the setting of ongoing operations early and be “tested, reviewed and practiced” while reliable back-up is available to facilitate an Enterprise-wide level of comfort and acceptance. Serious constraints on data transmission coupled with a large and expanding universe of on-board medical informatics data streams will necessitate implementation of a CDSS to supplant the current reliance on support provided by ground-based SMEs. Establishment of trust in the system by CMO/crew and the ground-based medical support team will be essential. Co-development of a CDSS with industry partners will assure that state of the art tools can be employed, and industry efficiencies can be leveraged. Training regimens, materials and tools must evolve to be responsive (just-in-time training) and facilitate autonomous execution of procedures. Proficiency metrics should be established and be based on validated competencies or milestones as opposed to a prescribed number of training hours. Training should be prioritized for broad, translatable skills that have universal application across a variety of medical conditions. Repetition was deemed to be the key to achieving proficiency and emphasis should lie in procedural training which is known to extinguish more rapidly than diagnostic skills. Advanced tools, e.g., extended reality, can provide more realistic and effective training. Use of advanced probabilistic risk assessment tools will be essential to optimize the medical system capability while carefully balancing risk relative to mass/power/volume limitations. Importance of factoring use-life of medical supplies and maintaining awareness of redundancy and opportunity to re-purpose under off nominal situations was emphasized. Consideration of adopting optimized performance standards vs. “good-enough” performance thresholds is warranted. The use of legacy systems as opposed to creating new systems may be preferable. Managing task load and associated cognitive load will be essential to maintain operational safety and behavioral health. ExMC aspires to create a shared EIMO paradigm and strategic vision for advancing medical system design through novel technologies, training, protocols, and support capabilities, built upon the spirit of successful strategies and innovations over the past six decades of space medicine operations.

Jay Lemery↗

Data Visualization: Augmented Reality

In recent years, there has been an increasing interest in developing new technologies for automated characterization and visualization of condition monitoring data. Augmented Reality (AR) is a technology that is being developed to improve such data visualization. Augmented reality has been defined as a technology that merges virtual and physical components in real-time, and in three dimensions. Wearable, commercially-available AR devices allow onsite engineers and technicians to perform inspection tasks with significantly more available information such as comparisons of past and present sensor and imager data, onsite data analysis and result displays, and various forms of metadata including technical drawings, previous inspection reports and maintenance histories, operation manuals, codes and standards, and holograms representing data analysis results superimposed onto the in situ monitored system.

42 ENGINEERING↗

Wearable Biosensor Monitor to Support Autonomous Crew Health and Readiness to Perform

For future human exploration missions, NASA needs a health monitoring system composed of hardware that is compact, fully interoperable with an integrated data management system, and requires minimal consumables. Such a system will be achieved through the integration of small, easy to use biomedical sensors that will have the ability to measure, store and transmit physiological parameters during operational and ambulatory activity. Since 2012, the Canadian Space Agency (CSA) has been active in funding the development of wearable biomonitoring sensors. The Astroskin is the first prototype and consists of a shirt-based garment and headband with embedded sensors, and associated software and technology that measure vital signs, sleep quality and activity level of the wearer. NASA and CSA have been collaborating since 2014 to test and validate this system in a lab environment at Ames Research Center and more recently in the Human Exploration Research Analog (HERA) located at Johnson Spaceflight Center. Specific objectives of the HERA study were: 1) to assess the performance of the Astroskin biosensor system for long-term health monitoring (24-hours) capabilities and during exercise as a measure of crew fitness; 2) to obtain crew feedback on comfort and usability of the Astroskin system; 3) to demonstrate performance of Bluetooth communication during real-time transmission and for verification of data in this environment; and 4) to obtain baseline data for further development of algorithms and tools that facilitate decision support for diagnosing and monitoring of a sick or injured crewmember. HERA Campaign 3 included four missions (each 30-days in duration) with four crewmembers assigned to each mission. A total of 9 men and 7 women participated in the Astroskin evaluation that included continuous physiological monitoring (24-hours) on mission days MD-11, MD1 (high workload), MD15 (low workload), MD19, MD29, and MD+7. Mission days 19 and 29 also included 30 minutes of sub-maximal exercise on a cycle ergometer. Following each 24-hour monitoring session crew physiological data were downloaded to laptops and each crewmember completed a 28 question survey on their experiences with the Astroskin hardware and software. This presentation will focus on lessons learned from the HERA missions. Specifically it will address Astroskin system performance in terms of data loss and data quality (no comparison to lab standard devices), wireless communication with the onboard mobile device, crew usability and comfort, and future development of a next generation biomonitoring system.

crew fitness↗

Integrated Ultra-Wideband Tracking and Carbon Dioxide Sensing System Design for International Space Station Applications

A three-dimensional (3D) Ultra-Wideband (UWB) Time-of-Arrival (TOA) tracking system has been studied at NASA Johnson Space Center (JSC) to provide the tracking capability inside the International Space Station (ISS) modules for various applications. One of applications is to locate and report the location where crew experienced possible high level of carbon-dioxide (CO2) and felt upset. Recent findings indicate that frequent, short-term crew exposure to elevated CO2 levels combined with other physiological impacts of microgravity may lead to a number of detrimental effects, including loss of vision. To evaluate the risks associated with transient elevated CO2 levels and design effective countermeasures, doctors must have access to frequent CO2 measurements in the immediate vicinity of individual crew members along with simultaneous measurements of their location in the space environment. To achieve this goal, a small, low-power, wearable system that integrates an accurate CO2 sensor with an ultra-wideband (UWB) radio capable of real-time location estimation and data communication is proposed. This system would be worn by crew members or mounted on a free-flyer and would automatically gather and transmit sampled sensor data tagged with real-time, high-resolution location information. Under the current proposed effort, a breadboard prototype of such a system has been developed. Although the initial effort is targeted to CO2 monitoring, the concept is applicable to other types of sensors. For the initial effort, a micro-controller is leveraged to integrate a low-power CO2 sensor with a commercially available UWB radio system with ranging capability. In order to accurately locate those places in a multipath intensive environment like ISS modules, it requires a robust real-time location system (RTLS) which can provide the required accuracy and update rate. A 3D UWB TOA tracking system with two-way ranging has been proposed and studied. The designed system will be tested in the Wireless Habitat Testbed which simulates the ISS module environment. This report describes the research and development effort for this prototype integrated UWB tracking and CO2 sensing system. The remainder of the report is organized as follows. In Section II, the TOA tracking methodology is introduced and the 3D tracking algorithm is derived. The simulation results are discussed in Section III. In Section VI, prototype system design and field tests are discussed. Some concluding remarks and future works are presented in Section V.

Ni, Jianjun (David)↗

Additively Printed Flexible Temperature Sensor for Wearable Applications

The flexible sensor has the capability to be mounted on any curved surfaces of applications and be used for portable devices. Additively printed sensors have received attention owing to their compact design and ability of application to non-planar surfaces. Wearable applications require capability of integration into a variety of surfaces with ability to flex, fold, twist and stretch under the stresses of daily motion. There is scarcity of data on the interaction of the process parameters with the realized performance. In addition, there is need for data focused on sensor accuracy, repeatability, and reliability. In this study, experimental analysis on function of the fabricated sensing board is conducted. The temperature sensors are made by direct write printing method with nScrypt printer. A calibration of the sensors has been conducted to confirm that resistance is well related to actual temperature and find TCR (temperature coefficient to resistance). The evolution of resistance has been correlated with the environmental temperature. The sensor hysteresis has been quantified using upswing and downswing of the environmental temperature. In addition, the effect of humidity on the temperature sensor accuracy and performance has been quantified. The effect of a polymide coat on the sensor to prevent humidity effects has also been quantified.

Pradeep Lall↗

Conducting polymer-based electrochemical sensors: Progress, challenges, and future perspectives

Conducting polymers are promising due to their unique properties, such as excellent electrical and optical properties, physical and chemical stability, high conductivity, and effective redox properties with high-temperature stability and biocompatibility. Due to these properties, conducting polymers are useful in diverse applications like sensors, batteries, oil industries, biosensors, biomedicines, catalysis, cancer treatment, etc. This review article aims to discuss the recent trends and analysis of conducting polymer-based electrochemical sensors in diverse areas with all required sensor characteristics, such as the derived limit of detection, utilized techniques for the sensing analysis and derived linear dynamic range with the stability of the sensors. Conducting polymers and their nanocomposites-based electrochemical sensors have demonstrated exceptional capabilities towards detecting various biomolecules, heavy metals, pesticides, and viruses like SARS-COV-2. Incorporation of redox mediators, use of conducting hydrogels, and molecular imprinting are promising strategies for better performance of the derived sensor. The article has demonstrated the existing challenges and limitations and provided solutions in the field. In the future, conducting polymers-based electrochemical sensors can be utilized in wearable sensors and integrated with IoT devices for better reach in real-time applications. They can also be made more accessible with precise control and data output by following specific methodologies. Utilizing green and sustainable conducting polymers can be crucial in advancing eco-friendly practices in the future. Conducting polymer-based electrochemical sensors has affectivity in neurochemical and pathogen sensing, which is essential for brain function and mental health.

42 ENGINEERING↗

Medical Signal-Conditioning and Data-Interface System

A general-purpose portable, wearable electronic signal-conditioning and data-interface system is being developed for medical applications. The system can acquire multiple physiological signals (e.g., electrocardiographic, electroencephalographic, and electromyographic signals) from sensors on the wearer s body, digitize those signals that are received in analog form, preprocess the resulting data, and transmit the data to one or more remote location(s) via a radiocommunication link and/or the Internet. The system includes a computer running data-object-oriented software that can be programmed to configure the system to accept almost any analog or digital input signals from medical devices. The computing hardware and software implement a general-purpose data-routing-and-encapsulation architecture that supports tagging of input data and routing the data in a standardized way through the Internet and other modern packet-switching networks to one or more computer(s) for review by physicians. The architecture supports multiple-site buffering of data for redundancy and reliability, and supports both real-time and slower-than-real-time collection, routing, and viewing of signal data. Routing and viewing stations support insertion of automated analysis routines to aid in encoding, analysis, viewing, and diagnosis.

Braun, Jeffrey↗

Predicting Team Functioning in Long Term Space Missions Using Acoustic and Linguistic Measures

Maintaining optimal team functioning is critical for long-duration space exploration missions, yet traditional monitoring methods, such as self-reports and wearable sensors, often impose operational burdens or suffer from bias. This paper investigates a non-intrusive speech-based artificial intelligence (AI) framework to predict degradations in team functioning using data from the Human Exploration Research Analog (HERA) of the U.S. National Aeronautics and Space Administration (NASA). Using acoustic features, linguistic descriptors, and semantic embeddings, we evaluate static non-linear and temporal machine learning models to predict both objective (task accuracy) and subjective (self-reported efficacy and cohesion) team functioning outcomes. Results indicate that temporal models outperform static approaches, with prediction of objective task accuracy in Team Interaction Battery (TIB) improving from near chance to 71%. Self-reported outcomes, including team efficacy and cohesion, are predicted more reliably than task performance, achieving balanced accuracies of up to 85.56% and 78.12%, respectively, and are found to be most strongly associated with acoustic features. In a second interdependent task, the MMSEV–EVA, accuracies of up to 78% are achieved using temporal models with acoustic features. Furthermore, incorporating just 1–2 days of team-specific historical data systematically improved performance, and acoustic markers from informal pre-task interactions provided modest predictive gains. Finally, while automated preprocessing yielded viable accuracy, humancorrected data provided moderate performance gains, though transcription error rates did not significantly correlate with model performance. These findings highlight the potential of speech as a passive, high-fidelity monitoring tool for autonomous habitats.

Temporal modeling↗