Search NASA⌕ Search

SEARCH · Search NASA

Results for “wearable sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Potential of Wearable Sensor Technology for EVA Glove Ergonomic Evaluation

Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). Many of these injuries refer to the gloves worn during EVA as the root cause. While pressurized, the bladder and outer material of these gloves restrict movement and create pressure points while performing tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally a more severe injury, onycholysis (fingernail delamination). The most common injury causes are glove contact (pressure point/rubbing), ill-fitting gloves, and/or performing EVA tasks in pressurized gloves. A brief review of the Lifetime Surveillance of Astronaut Health's injury database reveals over 57% of the total injuries to the upper extremities during EVA training occurred either to the metacarpophalangeal (MCP) joint, fingernail, or the fingertip. Twenty-five of these injuries resulted in a diagnosis of onycholysis.

Reid, Christopher R.↗

The Potential of Wearable Sensor Technology for EVA Glove Ergonomic Evaluation

Injuries to the hands are common among astronauts who train for extravehicular activity (EVA). Many of these injuries refer to the gloves worn during EVA as the root cause. While pressurized, the bladder and outer material of these gloves restrict movement and create pressure points while performing tasks, sometimes resulting in pain, muscle fatigue, abrasions, and occasionally a more severe injury, onycholysis (fingernail delamination). The most common injury causes are glove contact (pressure point/rubbing), ill-fitting gloves, and/or performing EVA tasks in pressurized gloves. A brief review of the Lifetime Surveillance of Astronaut Health's injury database reveals over 57% of the total injuries to the upper extremities during EVA training occurred either to the metacarpophalangeal (MCP) joint, fingernail, or the fingertip. Twenty-five of these injuries resulted in a diagnosis of onycholysis

Reid, Christopher R.↗

Additively Printed Flexible Temperature Sensor for Wearable Applications

The flexible sensor has the capability to be mounted on any curved surfaces of applications and be used for portable devices. Additively printed sensors have received attention owing to their compact design and ability of application to non-planar surfaces. Wearable applications require capability of integration into a variety of surfaces with ability to flex, fold, twist and stretch under the stresses of daily motion. There is scarcity of data on the interaction of the process parameters with the realized performance. In addition, there is need for data focused on sensor accuracy, repeatability, and reliability. In this study, experimental analysis on function of the fabricated sensing board is conducted. The temperature sensors are made by direct write printing method with nScrypt printer. A calibration of the sensors has been conducted to confirm that resistance is well related to actual temperature and find TCR (temperature coefficient to resistance). The evolution of resistance has been correlated with the environmental temperature. The sensor hysteresis has been quantified using upswing and downswing of the environmental temperature. In addition, the effect of humidity on the temperature sensor accuracy and performance has been quantified. The effect of a polymide coat on the sensor to prevent humidity effects has also been quantified.

Pradeep Lall↗

Lunar Health Monitor (LHM)

Orbital Research, Inc., has developed a low-profile, wearable sensor suite for monitoring astronaut health in both intravehicular and extravehicular activities. The Lunar Health Monitor measures respiration, body temperature, electrocardiogram (EKG) heart rate, and other cardiac functions. Orbital Research's dry recording electrode is central to the innovation and can be incorporated into garments, eliminating the need for conductive pastes, adhesives, or gels. The patented dry recording electrode has been approved by the U.S. Food and Drug Administration. The LHM is easily worn under flight gear or with civilian clothing, making the system completely versatile for applications where continuous physiological monitoring is needed. During Phase II, Orbital Research developed a second-generation LHM that allows sensor customization for specific monitoring applications and anatomical constraints. Evaluations included graded exercise tests, lunar mission task simulations, functional battery tests, and resting measures. The LHM represents the successful integration of sensors into a wearable platform to capture long-duration and ambulatory physiological markers.

Lisy, Frederick J.↗

Human Research Program Advanced Exercise Concepts (AEC) Overview

Exercise countermeasures provide benefits that are crucial for successful human spaceflight, to mitigate the spaceflight physiological deconditioning which occurs during exposure to microgravity. The NASA Human Research Program (HRP) within the Human Exploration and Operations Mission Directorate (HEOMD) is managing next generation Advanced Exercise Concepts (AEC) requirements development and candidate technology maturation to Technology Readiness Level (TRL) 7 (ground prototyping and flight demonstration) for all exploration mission profiles from Multi Purpose Crew Vehicle (MPCV) Exploration Missions (up to 21 day duration) to Mars Transit (up to 1000 day duration) missions. These validated and optimized exercise countermeasures systems will be provided to the ISS Program and MPCV Program for subsequent flight development and operations. The International Space Station (ISS) currently has three major pieces of operational exercise countermeasures hardware: the Advanced Resistive Exercise Device (ARED), the second-generation (T2) treadmill, and the cycle ergometer with vibration isolation system (CEVIS). This suite of exercise countermeasures hardware serves as a benchmark and is a vast improvement over previous generations of countermeasures hardware, providing both aerobic and resistive exercise for the crew. However, vehicle and resource constraints for future exploration missions beyond low Earth orbit will require that the exercise countermeasures hardware mass, volume, and power be minimized, while preserving the current ISS capabilities or even enhancing these exercise capabilities directed at mission specific physiological functional performance and medical standards requirements. Further, mission-specific considerations such as preservation of sensorimotor function, autonomous and adaptable operation, integration with medical data systems, rehabilitation, and in-flight monitoring and feedback are being developed for integration with the exercise countermeasures systems. Numerous technologies have been considered and evaluated against HRP-approved functional device requirements for these extreme mission profiles, and include wearable sensors, exoskeletons, flywheel, pneumatic, and closed-loop microprocessor controlled motor driven systems. Each technology has unique advantages and disadvantages. The Advanced Exercise Concepts project oversees development of candidate next generation exercise countermeasures hardware, performs trade studies of current and state of the art exercise technologies, manages and supports candidate systems physiological evaluations with human test subjects on the ground, in flight analogs and flight. The near term goal is evaluation of candidate systems in flight, culminating in an integrated candidate next generation exercise countermeasures suite on the ISS which coalesces research findings from HRP disciplines in the areas of exercise performance for muscle, bone, cardiovascular, sensorimotor, behavioral health, and nutrition for optimal benefit to the crew.

Countermeasures↗

Scientific Physical and Operations Characterization (SPOC): Studying Scientists in the Wild to Inform Human Planetary Exploration Operations

The objective of the Scientific Physical and Operational Characterization (SPOC) project is to build an evidence-based description of terrestrial field science to inform the operational, physical, and tool requirements for planetary exploration extravehicular activities (xEVAs). EVAs of the future, including Artemis 2024 and beyond, intend to promote scientific productivity (e.g., LEAG science goals)[1]; however, no clear, objective pathway currently exists to enable this goal, particularly with respect to the desired increase in autonomy imparted to future astronauts. The SPOC project applies expertise in the fields of cognitive systems engineering [2-5], biomechanics, wearable sensors [6-8] and hardware/software to more targetly address these issues. In doing so, a terrestrial fieldwork ground-truth can be established that will benefit human and robotic exploration of other planetary surfaces.

M J Miller↗

Intelligent Devices/Equipment/Instruments (IDEI) for Enabling Crew Health and Performance on Mars

The Moon to Mars eXploration Systems and Habitation (M2M X-Hab) 2024 Academic Innovation Challenge features a project titled “Intelligent Devices/Equipment/Instruments (IDEI) for Enabling Crew Health and Performance on Mars”. The project calls for the development of prototype IDEIs “that could be used for implementing integrated system health management for Crew Health and Performance (CHP) required for crew living on Mars for extended periods of time”. Thus, the deliverable for the project is not only a prototype exercise device, but also an ontology that provides insight into the best ways to exercise on Mars. To that end, we on the BLiSS team, supported by advisors from industry and academia, set out to ideate an exercise ontology and demonstrate its effectiveness through a functional prototype. To achieve the stakeholders’ requests, the device must operate semi-autonomously, must be an analog for an extant exercise device on Earth, and must provide quantitative information about the exercise and the device’s own state of health. Here, we define “semi-autonomous” as referring to the fact that while the system should be as autonomous as possible, there are some processes that the system cannot fulfill on its own. These include, but are not limited to, user identification, physical exercise reconfiguration, and wearable sensor placement.

llyana Smith↗

Summary of Technical Interchange Meetings (TIMs) Designed to Enable Earth Independent Medical Operations (EIMO)

The Exploration Medical Capability Element (ExMC) in NASA’s Human Research Program hosted a series of TIMs in 2023-2024 designed to stimulate discussion around specific topics with the goal of enabling EIMO. In context of the thematic constituent elements of EIMO, namely pre-mission planning, acute/emergent/prolonged medical decision making, supply/resource management and task load management, subject matter experts from industry, academia and government (NASA and other Agencies) provided valuable and actionable guidance and recommendations. Earth-based medical experts will remain indispensable for pre-mission planning, however, management of acute/emergent medical contingencies will require a gradual transition of medical care and decision making from terrestrial to space-based assets to enable support of astronaut health and performance and reduce overall mission risk. Key to achieving these enhancements is providing an integrated data system platform capable of utilizing multiple data streams in concert with a variety of on-board databases and passive monitoring of video and wearable sensors to enable a multi-modal, agentic AI-based clinical decision support system (CDSS) to support crew medical officer (CMO) medical decision-making. The EIMO series of TIMs (I-V) have proven to be instructive and portend a significant paradigm shift will be necessary to maintain crew health and performance on exploration class missions. Importantly, since the expected paradigm shift will be significantly different from the methods of operation that have been employed for the majority of missions from the inception of human spaceflight to date, any proposed methods must be deployed in the setting of ongoing operations early and be “tested, reviewed and practiced” while reliable back-up is available to facilitate an Enterprise-wide level of comfort and acceptance. Serious constraints on data transmission coupled with a large and expanding universe of on-board medical informatics data streams will necessitate implementation of a CDSS to supplant the current reliance on support provided by ground-based SMEs. Establishment of trust in the system by CMO/crew and the ground-based medical support team will be essential. Co-development of a CDSS with industry partners will assure that state of the art tools can be employed, and industry efficiencies can be leveraged. Training regimens, materials and tools must evolve to be responsive (just-in-time training) and facilitate autonomous execution of procedures. Proficiency metrics should be established and be based on validated competencies or milestones as opposed to a prescribed number of training hours. Training should be prioritized for broad, translatable skills that have universal application across a variety of medical conditions. Repetition was deemed to be the key to achieving proficiency and emphasis should lie in procedural training which is known to extinguish more rapidly than diagnostic skills. Advanced tools, e.g., extended reality, can provide more realistic and effective training. Use of advanced probabilistic risk assessment tools will be essential to optimize the medical system capability while carefully balancing risk relative to mass/power/volume limitations. Importance of factoring use-life of medical supplies and maintaining awareness of redundancy and opportunity to re-purpose under off nominal situations was emphasized. Consideration of adopting optimized performance standards vs. “good-enough” performance thresholds is warranted. The use of legacy systems as opposed to creating new systems may be preferable. Managing task load and associated cognitive load will be essential to maintain operational safety and behavioral health. ExMC aspires to create a shared EIMO paradigm and strategic vision for advancing medical system design through novel technologies, training, protocols, and support capabilities, built upon the spirit of successful strategies and innovations over the past six decades of space medicine operations.

Jay Lemery↗

Earth-Independent Medical Operations (EIMO) Concept of Operations

In contrast to the current crew health paradigm for low-Earth orbit and Lunar missions, which depends on real-time communication with Mission Control, deep-space exploration missions will require a significant shift in medical operations. This shift is driven by the constraints of operating at a considerable distance from Earth, such as resource limitations—lack of resupply, restricted mass, power, volume, and data—as well as communication delays and the inability to evacuate back to Earth during emergencies. To move toward a more self-reliant medical model, a strategy is needed to gradually increase space-based crew autonomy and reduce risks to mission success in the challenging environment of deep space. This transformative change, known as "Earth-Independent Medical Operations" (EIMO), explores the gradual transfer of medical care and decision-making from Earth-based support to space-based systems. The goal of this transition is to enhance astronaut health and performance while minimizing mission risks. EIMO requires the development of a medical system that integrates seamlessly with mission planning, vehicle and spacesuit design, and data architecture. This integration is crucial for building a robust medical infrastructure that not only safeguards astronaut well-being but also ensures overall mission success. The Human Research Program (HRP) Exploration Medical Capability (ExMC) Element has revised the EIMO model-based Concept of Operations (ConOps) which outlines an initial vision for EIMO. The ConOps, which is built on the stakeholders’ need, system goals, and objectives (NGOs), presents an array of in-mission scenarios that span a wide range of medical conditions demonstrating the system’s capabilities from basic to complex events. Developed by a multidisciplinary team of systems engineers, scientists, and clinicians within ExMC, the ConOps revision includes two new scenarios(Barotrauma and Self-Medical Management and Behavioral Health and Chronic Medical Care), and implementation of findings from EIMO technical interchange meetings that focused on data and training. The envisioned EIMO Medical System (MS) operates as a system of systems, gathering data from various sources such as reference databases, real-time wearable sensors, point-of-care diagnostics, and environmental controls. The MS also incorporates advanced training tools to support autonomous medical care, assisting the Crew Medical Officer (CMO) during medical events where Ground Support is either unavailable or communication-delayed beyond practicality. Furthermore, MS functions and capabilities were decomposed from the scenarios to establish foundational requirements for EIMO and traced to the NASA Spaceflight Human-System Standard(NASA-STD-3001, Volumes 1 and 2). These traces were performed to gain insights on the alignment of EIMO requirements with the NASA standard. This work serves as an initial recommendation to increase crew autonomy gradually and safely for Mars missions and future deep-space exploration.

medical system↗

Predicting Team Functioning in Long Term Space Missions Using Acoustic and Linguistic Measures

Maintaining optimal team functioning is critical for long-duration space exploration missions, yet traditional monitoring methods, such as self-reports and wearable sensors, often impose operational burdens or suffer from bias. This paper investigates a non-intrusive speech-based artificial intelligence (AI) framework to predict degradations in team functioning using data from the Human Exploration Research Analog (HERA) of the U.S. National Aeronautics and Space Administration (NASA). Using acoustic features, linguistic descriptors, and semantic embeddings, we evaluate static non-linear and temporal machine learning models to predict both objective (task accuracy) and subjective (self-reported efficacy and cohesion) team functioning outcomes. Results indicate that temporal models outperform static approaches, with prediction of objective task accuracy in Team Interaction Battery (TIB) improving from near chance to 71%. Self-reported outcomes, including team efficacy and cohesion, are predicted more reliably than task performance, achieving balanced accuracies of up to 85.56% and 78.12%, respectively, and are found to be most strongly associated with acoustic features. In a second interdependent task, the MMSEV–EVA, accuracies of up to 78% are achieved using temporal models with acoustic features. Furthermore, incorporating just 1–2 days of team-specific historical data systematically improved performance, and acoustic markers from informal pre-task interactions provided modest predictive gains. Finally, while automated preprocessing yielded viable accuracy, humancorrected data provided moderate performance gains, though transcription error rates did not significantly correlate with model performance. These findings highlight the potential of speech as a passive, high-fidelity monitoring tool for autonomous habitats.

Temporal modeling↗

Lightweight, Wearable, Metal Rubber Sensor

For autonomous health monitoring. NanoSonic, Inc., has developed comfortable garments with multiple integrated sensors designed to monitor astronaut health throughout long-duration space missions. The combined high electrical conductivity, low mechanical modulus, and environmental robustness of the sensors make them an effective, lightweight, and comfortable alternative to conventional use of metal wiring and cabling.

Hill, Andrea↗

Sub-micron surface plasmon resonance sensor systems

Wearable or implantable devices combining microfluidic control of sample and reagent flow and micro-cavity surface plasmon resonance sensors functionalized with surface treatments or coatings capable of specifically binding to target analytes, ligands, or molecules in a bodily fluid are provided. The devices can be used to determine the presence and concentration of target analytes in the bodily fluids and thereby help diagnose, monitor or detect changes in disease conditions.

Glazier, James A.↗

AIAA Ascend 2021 Conference On Demand Manufacturing of Electronics Panel Abstract

1. Session Proposal o Session Title NASA’s In Space Manufacturing and the On Demand Manufacturing of Electronics o Session Topic Primary -- Space Logistics, Autonomy, and Robotics; Secondary – Transformative Research and Technologies o Session Format: Panel Discussion. o Requested Session Duration: 60 minutes o Short Session Description: The goal of NASA’s On Demand Manufacturing of Electronics project is to develop and demonstrate the feasibility of a low-gravity, on-demand manufacturing system for flexible hybrid electronic devices on the International Space Station. This panel will feature several key collaborators and team members from the commercial sector, academia, and internal to NASA, each of which are contributing an unique and vital role to the design and implementation of this new technology system. o Extended Session Description (Please describe in detail the activity proposed, including how you intend to use the requested session duration. This session description will be provided to the reviewers for consideration and will not be displayed in the online agenda.): The session will be moderated by Curtis Hill, the Project Lead for the On Demand Manufacturing of Electronics (ODME), and he will start by giving a brief introduction to the ODME project which is working to produce a demo system for the manufacturing of electronic devices on the International Space Station. Panelists consisting of collaborators and team members to the ODME project will then give a brief (~5 min) introduction highlighting their contributions to the project, followed by time for Q&A from the audience. The panel will consist of: 1. Kenneth Church, nScrypt. nScrypt is a leader in multi-material printing with a modular system that incorporates a direct write thick film print head, a polymer fused filament fabrication print head, a laser sintering attachment, a drill head attachment for milling, and a pick and place. The system can print a layer and scan for accuracy of prints. The combination of multiple print heads and scanning allows for the on-demand production of intricate electronic components. 2. Andy Kurk, TechShot, Inc. Techshot, Inc. has collaborated extensively with NASA on the in space manufacturing of both printed electronics and fused metal materials. They are currently working to develop and integrate a test system for printed electronics, and a flight demonstration on the International Space Station is anticipated in 2024. 3. Ed Hendricks, NextFlex. NextFlex has the goal of advancing the manufacture of flexible hybrid electronics in the U.S. They are working with ODME on the development of AstroSense, an additively manufactured, wireless, flexible, and wearable health sensor. 4. Dr. Pradeep Lall, Auburn University. Professor Lall is the MacFarlane Endowed Distinguished Professor in the Department of Mechanical Engineering with a Courtesy Joint Appointment in the Department of Electrical and Computer Engineering and a Courtesy Joint Appointment in the Department of Finance. He is collaborating with NASA’s ODME project to develop multilayer printable devices and to develop techniques to test the quality of a printed electronic device. 5. Dr. Wei Gao, California Institute of Technology. Professor Gao is an Assistant Professor of Medical Engineering. His group is developing fully printed, flexible, and wearable biosensors for crew health monitoring in collaboration with NASA’s ODME project. In addition, they are working on using sweat to power biofuel cells for wearable, self-powered electronic devices. 6. Beth Paquette, NASA Goddard. The ODME branch at NASA Goddard is spearheading a sounding rocket flight demo to prove the capability of a printed electronic device with multiple sensors. In addition, they focus on thin film and flexible energy storage evaluations. o Session Goal(s)/Outcome(s): Please list the learning objectives and/or tangible outcomes (technical paper or other publication). The goal of this session is to highlight the internal and collaborative efforts of NASA’s On Demand Manufacturing of Electronics project to develop a system for printing electronics that will be tested on the International Space Station in 2024. In addition, the session with facilitate discussion with the community on the state of the art of printable electronics, current challenges, and new avenues for collaboration.

Jennifer McInnis Jones↗

Exosuit Prototypic Knee: EPK

Resistive/aerobic exercises are invaluable countermeasures to musculoskeletal/sensorimotor/cognitive deconditioning resulting from spaceflight (i.e., microgravity). In preparation for human exploration to the moon and beyond, exercise countermeasures face new mass/volume constraints, rendering current on-orbit systems infeasible. Further, effective exercise systems are critical for maintaining crew performance/health levels necessary for Lunar extravehicular activities (EVAs) and transit. Exosuits are the pinnacle of wearable and adaptable technology set to provide a lightweight, compact, innovative solution to exploration-constrained exercise. However, reliable wearable kinematic sensors integrated with softgoods have not been demonstrated in (operational) spaceflight applications. To address this gap, the project team developed a prototype exosuit knee-joint, replete with relevant sensors for determination of joint angles, and corresponding laboratory testing bench to validate the exosuit sensing performance. This technology advancement is a pre-cursor to a more expansive multi-purpose exosuit concept that provides metrology, exercise, rehabilitation, and/or augmentation.

Fiber optics↗

Application of Bioengineering in Space Exploration - Sleep Study System

Bioengineering has spread roots far and wide among the needs of space exploration. The field creates many of paths to generate information from a variety of sources. One such source is the astronauts on the International Space Station (ISS). As of now the investigation is focused on the quality of sleep of crew members during a long duration flight. Our team is investing time into a piece of hardware’s comfort, waste, and operability. The hardware was not originally designed for space; therefore, the device must be modified to function at a optimal level in space. The design not made for space has generated some ailments, such as discomfort and decreased mobility. A function of the internship was to produce designs that would manage the wires to increase mobility and comfort. The wires excess slack was reduced by the part that was designed. The piece was adjustable, so the patient may adjust the system to their comfort and space compatible material was used. This product will help control the direction and length of the wires, thereby aiding in comforting the patient. This multifaceted design may be used in future for all other wire management for wearable biomedical sensor on orbit.

Biomedical↗

User-Wearable Devices that Monitor Exposure to Blue Light and Recommend Adjustments Thereto

Described herein are user-wearable devices that include an optical sensor, and methods for use therewith. In certain embodiments, an optical sensor of a user-wearable device (e.g., a wrist-worn device) is used to detect blue light that is incident on the optical sensor and to produce a blue light detection signal indicative thereof, and thus, indicative of the response of the user's intrinsically photosensitive Retinal Ganglion Cells (ipRGCs). In dependence on the blue light detection signal, there is a determination of a metric indicative of an amount of blue light detected by the optical sensor. The metric is compared to a corresponding threshold, and a user notification is triggered in dependence on results of the comparing, wherein the user notification informs a person wearing the user-wearable device to adjust their exposure to light.

Lee, Yong Jin↗

Wearable Wireless Telemetry System for Implantable Bio-MEMS Sensors

In this paper, a telemetry and contact-less powering system consisting of an implantable bio-MEMS sensor with a miniature printed square spiral chip antenna and an external wearable garment with printed loop antenna is investigated. The wearable garment pick-up antenna and the implantable chip antenna are in close proximity to each other and hence couple inductively through their near-fields and behave as the primary and the secondary circuits of a transformer, respectively. The numerical and experimental results are graphically presented, and include the design parameter values as a function of the geometry, the relative RF magnetic near-field intensity as a function of the distance and angle, and the current density on the strip conductors, for the implantable chip antenna.

Simons, Rainee N.↗