Search NASA⌕ Search

SEARCH · Search NASA

Results for “wedge sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation of a wedge gas-sampling probe

The performances of a wedge-type gas-sampling probe and pitot probes are compared in applications to flowfield profile studies. The flow structure data obtained by these techniques are found to agree well in flow regions with and without significant gradients. The wedge-type probe showed a good service life and allowed a substantial reduction of the sampling time. The wedge probe design is discussed.

Beach, H. L., Jr.↗

New Technologies Advancing Thermophysics

Researchers at NASA Ames in California have built a new facility that uses multiple 50-kW continuous wave lasers to add the capability for simulating radiative heating on thermal protection materials. The new facility, the Laser Enhanced Arc-jet Facility (LEAF-Lite), was added to NASA Ames’s Interaction Heating Facility arc-jet and now allows for test articles to be heated by both convective and radiative heat flux, making the facility more like flight. Using this new system, researchers can now simulate radiant heating with the laser and convective heating with the arc-jet simultaneously on a single test article. During its initial test in October 2017, the lasers radiatively heated a 6” x 6” Avcoat wedge sample to 405 W/sq.cm while the arc-jet simultaneously provided 160 W/sq.cm of convective heat, resulting in a total heat flux of 565 W/sq.cm. Radiative heating is more prevalent in missions with higher atmospheric entry speeds like the Orion space capsule or interplanetary scientific probes. Later this year, scientists will expand the spot size to cover 17” x 17” to test an Orion TPS panel.

Brandis, Aaron↗

Permittivity of water at millimeter wave-lengths

Work performed on the permittivity of seawater and ice at 100 GHz was described. Measurements on water covered the temperature range from 0 to 50 C, while the measurements on ice were taken near - 10 C. In addition, a small number of measurements were made on the reflectivity of absorber materials used in a previous program on research in millimeter wave techniques. Normal incidence reflectivity was measured, and the result was used to obtain the index of refraction. For the case of normal incidence, reflectivity at a fixed temperature was reproducible to 1% for values near 40%. For reflectivity measurements on ice, the lack of attenuation leads to reflection from the back surface of the sample; this complication was circumvented by using a wedge shaped sample and freezing the water in a container lined with absorber material.

Blue, M. D.↗

Laser measurement of extinction coefficients of highly absorbing liquids

A coaxial dual-channel laser system has been developed for the measurement of extinction coefficients of highly absorbing liquids. An empty wedge-shaped sample cell is first translated laterally through a He-Ne laser beam to measure the differential thickness using interference fringes in reflection. The wedge cell is carefully filled with the oil sample and translated through the coaxially positioned dye laser beam for the differential attenuation or extinction measurement. Optional use of the instrumentation as a single-channel extinction measurement system and also as a refractometer is detailed. The system and calibration techniques were applied to the measurement of two crude oils whose extinction values were required to complete the analysis of airborne laser data gathered over four controlled spills.

Hoge, F. E.↗

Hot corrosion of low cobalt alloys

The hot corrosion attack susceptibility of various alloys as a function of strategic materials content are investigated. Preliminary results were obtained for two commercial alloys, UDIMET 700 and Mar-M 247, that were modified by varying the cobalt content. For both alloys the cobalt content was reduced in steps to zero. Nickel content was increased accordingly to make up for the reduced cobalt but all other constituents were held constant. Wedge bar test samples were produced by casting. The hot corrosion test consisted of cyclically exposing samples to the high velocity flow of combustion products from an air-fuel burner fueled with jet A-1 and seeded with a sodium chloride aqueous solution. The flow velocity was Mach 0.5 and the sodium level was maintained at 0.5 ppm in terms of fuel plus air. The test cycle consisted of holding the test samples at 900 C for 1 hour followed by 3 minutes in which the sample could cool to room temperature in an ambient temperature air stream.

Stearns, C. A.↗

Deployable Aeroshell Flexible Thermal Protection System Testing

Deployable aeroshells offer the promise of achieving larger aeroshell surface areas for entry vehicles than otherwise attainable without deployment. With the larger surface area comes the ability to decelerate high-mass entry vehicles at relatively low ballistic coefficients. However, for an aeroshell to perform even at the low ballistic coefficients attainable with deployable aeroshells, a flexible thermal protection system (TPS) is required that is capable of surviving reasonably high heat flux and durable enough to survive the rigors of construction handling, high density packing, deployment, aerodynamic loading and aerothermal heating. The Program for the Advancement of Inflatable Decelerators for Atmospheric Entry (PAIDAE) is tasked with developing the technologies required to increase the technology readiness level (TRL) of inflatable deployable aeroshells, and one of several of the technologies PAIDAE is developing for use on inflatable aeroshells is flexible TPS. Several flexible TPS layups were designed, based on commercially available materials, and tested in NASA Langley Research Center's 8 Foot High Temperature Tunnel (8ft HTT). The TPS layups were designed for, and tested at three different conditions that are representative of conditions seen in entry simulation analyses of inflatable aeroshell concepts. Two conditions were produced in a single run with a sting-mounted dual wedge test fixture. The dual wedge test fixture had one row of sample mounting locations (forward) at about half the running length of the top surface of the wedge. At about two thirds of the running length of the wedge, a second test surface drafted up at five degrees relative to the first test surface established the remaining running length of the wedge test fixture. A second row of sample mounting locations (aft) was positioned in the middle of the running length of the second test surface. Once the desired flow conditions were established in the test section the dual wedge test fixture, oriented at 5 degrees angle of attack down, was injected into the flow. In this configuration the aft sample mounting location was subjected to roughly twice the heat flux and surface pressure of the forward mounting location. The tunnel was run at two different conditions for the test series: 1) 'Low Pressure', and 2) 'High Pressure'. At 'Low Pressure' conditions the TPS layups were tested at 6W/cm2 and 11W/cm2 while at 'High Pressure' conditions the TPS layups were tested at 11W/cm2 and 20W/cm2. This paper details the test configuration of the TPS samples in the 8Ft HTT, the sample holder assembly, TPS sample layup construction, sample instrumentation, results from this testing, as well as lessons learned.

Hughes, Stephen J.↗

Measurement of birefringence of optical materials using a wedged plate interferometer

A nondestructive technique for measuring the birefringence of optical materials such as calcite using wedged plate interferometer is presented. The sample needed for measuring the refractive index must be polished in the form of a parallel plate. The method is based on the measurement of the longitudinal displacement of the focus when the parallel plate is inserted in a converging beam of light. The displacement of the focus is a measure of the refractive index of the optical material. In the case of a uniaxial crystal, the displacement of the focus for the extraordinary ray is different from the displacement of the focus for the ordinary ray. Hence the birefringence of the crystal is determined by measuring the difference between the two focii. It is possible to obtain an accuracy up to 0.0002 in the measurement of birefringence depending on the sample thickness. The method should find its application for the characterization of new crystals in various material research and crystal growth laboratories.

Shukla, R. P.↗

Stream pattern analysis using optical processing of ERTS imagery of Kansas

A spatial frequency analysis was carried out to obtain large-scale geologic and other ground pattern spatial frequency and orientational data from an optical data processing system using Earth Resources Technology Satellite-1 (ERTS-1) imagery of Kansas as input. The Diffraction Pattern Sampling Unit (DPSU) of the optical data processing system consists of a photodiode array containing 32 wedge-shaped photodiodes and 32 annular ring diodes. The curve obtained from the intensity distribution of the frequency spectrum yielded by the ring diodes gives the spatial frequency contributions due to ground features on the image. The curve obtained from the wedge-shaped diodes indicates the orientation of features in the sample area. Ten sample sites were used for each of eight geologic-physiographic regions. Comparison of ERTS-1 images with their respective spatial frequency and orientational curves reveals that preferred orientations of drainage produce recognizable peaks.

Mccauley, J.↗

Multispectral Scanner (MSS) Instrument Description

The MSS sensor image processing and resolution capabilities as well as a general system description are presented in chart form. Emphasis is placed on absolute radiometric calibration, video and wedge level timing sequence, focal plane dimensions, sampling sequence, and a description of the mirror coordinate systems.

Barker, J. L.↗

Magneto-optic superlattice thin films: Fabrication, structural and magnetic characterization

During this quarter studies were extended to determine the electronic contribution to the perpendicular interface anisotropy in Co-based multilayers. Using in situ Kerr effect measurements, the influences of different transition metals (TM = Ag, Au, Cu, and Pd) on the magnetic properties of single-crystal Co films grown on Pd (111) and Au (111) surfaces are investigated. Last quarter the discovery of a large peak in the perpendicular anisotropy when approximately one monolayer of Cu or Ag is deposited on the Co surface was reported. We now have added a computer-controlled stepper-motor drive to our MBE sample transfer mechanism. The motor allows us to move the sample at a constant velocity from behind a shutter during deposition. The film, therefore, is deposited as a wedge with a linear variation of thickness across the substrate. In this way, a continuous range of coverage on a single sample is studied. The stepper motor also provides the necessary control for precisely positioning the sample in the laser beam for Kerr effect measurements at the different coverages.

Falco, C. M.↗

Monitoring physical and chemical parameters of Delaware Bay waters with an ERTS-1 data collection platform

The author has identified the following significant results. Results of the analysis of data collected during the summer of 1974 demonstrate that the ERTS Data Collection Platform (DCP) is quite responsive to changing water parameters and that this information can be successfully transmitted under all weather conditions. The monitoring of on-site probe outputs reveals a rapid response to changing water temperature, salinity, and turbidity conditions on incoming tides as the tidal salt wedge passes the probe location. The changes in water properties were corroborated by simultaneously sampling the water for subsequent laboratory analysis. Fluctuations observed in the values of salinity, conductivity, temperature and water depth over short time intervals were extremely small. Due to the nature of the probe, 10% to 20% fluctuations were observed in the turbidity values. The use of the average of the values observed during an overpass provided acceptable results. Good quality data was obtained from the satellite on each overpass regardless of weather conditions. Continued use of the DCP will help provide an indication of the accuracy of the probes and transmission system during long term use.

Klemas, V.↗

Nomenclature for the OSIRIS-REx Returned Sample Collection to be Curated at NASA Johnson Space Center

The Origins, Spectral Interpretation, Resource Identification, and Security–Regolith Explorer (OSIRIS-REx) space-craft collected material from the asteroid Bennu on October 20, 2020. The OSIRIS-REx Sample Return Capsule (SRC) is planned to return to Earth on September 24, 2023. The OSIRIS-REx returned sample collection to be curated at NASA Johnson Space Center (JSC) will include both the asteroid material and the flight hardware. We expect most of the asteroid material to be inside the head of the Touch-and-Go Sample Acquisition Mechanism (TAGSAM), and that this material will include a broad range of particles sizes from as large as a few centimeters to less than a micrometer across in their longest dimension. In addition, asteroid material may have been returned along with the flight hardware: intentionally by the contact pads or screens on the witness plates, or serendipitously wedged into or adhering to hardware items. The nomenclature for this new astromaterials collection must accommodate the different types of samples it comprises.

asteroid↗

Electromagnetic scattering from microwave absorbers - Laboratory verification of the coupled wave theory

W-band measurements of the bistatic scattering function of some common microwave absorbing structures, including periodic wedge-type and pyramid-type iron-epoxy calibration loads and flat carbon-foam 'Echosorb' samples, were made using a network analyzer interface to a focused-lens scattering range. Swept frequency measurements over the 75-100 GHz band revealed specular and Bragg reflection characteristics in the measured data.

Gasiewski, A. J.↗

Acquisition and Retaining Granular Samples via a Rotating Coring Bit

This device takes advantage of the centrifugal forces that are generated when a coring bit is rotated, and a granular sample is entered into the bit while it is spinning, making it adhere to the internal wall of the bit, where it compacts itself into the wall of the bit. The bit can be specially designed to increase the effectiveness of regolith capturing while turning and penetrating the subsurface. The bit teeth can be oriented such that they direct the regolith toward the bit axis during the rotation of the bit. The bit can be designed with an internal flute that directs the regolith upward inside the bit. The use of both the teeth and flute can be implemented in the same bit. The bit can also be designed with an internal spiral into which the various particles wedge. In another implementation, the bit can be designed to collect regolith primarily from a specific depth. For that implementation, the bit can be designed such that when turning one way, the teeth guide the regolith outward of the bit and when turning in the opposite direction, the teeth will guide the regolith inward into the bit internal section. This mechanism can be implemented with or without an internal flute. The device is based on the use of a spinning coring bit (hollow interior) as a means of retaining granular sample, and the acquisition is done by inserting the bit into the subsurface of a regolith, soil, or powder. To demonstrate the concept, a commercial drill and a coring bit were used. The bit was turned and inserted into the soil that was contained in a bucket. While spinning the bit (at speeds of 600 to 700 RPM), the drill was lifted and the soil was retained inside the bit. To prove this point, the drill was turned horizontally, and the acquired soil was still inside the bit. The basic theory behind the process of retaining unconsolidated mass that can be acquired by the centrifugal forces of the bit is determined by noting that in order to stay inside the interior of the bit, the frictional force must be greater than the weight of the sample. The bit can be designed with an internal sleeve to serve as a container for granular samples. This tube-shaped component can be extracted upon completion of the sampling, and the bottom can be capped by placing the bit onto a corklike component. Then, upon removal of the internal tube, the top section can be sealed. The novel features of this device are: center dot A mechanism of acquiring and retaining granular samples using a coring bit without a closed door. center dot An acquisition bit that has internal structure such as a waffle pattern for compartmentalizing or helical internal flute to propel the sample inside the bit and help in acquiring and retaining granular samples. center dot A bit with an internal spiral into which the various particles wedge. center dot A design that provides a method of testing frictional properties of the granular samples and potentially segregating particles based on size and density. A controlled acceleration or deceleration may be used to drop the least-frictional particles or to eventually shear the unconsolidated material near the bit center.

Bar-Cohen, Yoseph↗

The JWST/NIRCam Coronagraph: Mask Design and Fabrication

The NIRCam instrument on the James Webb Space Telescope will provide coronagraphic imaging from lambda =1-5 microns of high contrast sources such as extrasolar planets and circumstellar disks. A Lyot coronagraph with a variety of circular and wedge-shaped occulting masks and matching Lyot pupil stops will be implemented. The occulters approximate grayscale transmission profiles using halftone binary patterns comprising wavelength-sized metal dots on anti-reflection coated sapphire substrates. The mask patterns are being created in the Micro Devices Laboratory at the Jet Propulsion Laboratory using electron beam lithography. Samples of these occulters have been successfully evaluated in a coronagraphic testbed. In a separate process, the complex apertures that form the Lyot stops will be deposited onto optical wedges. The NIRCam coronagraph flight components are expected to be completed this year.

Coronagraph↗

Hypersonic, nonequilibrium flow over a cylindrically blunted 6 deg wedge

The numerical simulation of hypersonic flow in chemical nonequilibrium over cylindrically blunted 6 degree wedge is described. The simulation was executed on a Cray C-90 with Program LAURA 92-vl. Code setup procedures and sample results, including grid refinement studies and variations of species number are discussed. This simulation relates to a study of wing leading edge heating on transatmospheric vehicles.

Gnoffo, Peter A.↗

An interdisciplinary study of the estaurine and coastal oceanography of Block Island Sound and adjacent New York coastal waters

ERTS-1 photographic data products have been analyzed using additive color viewing and electronic image analysis techniques. Satellite data were compared to water sample data collected simultaneously with the data of ERTS-1 coverage in New York Bight. Prediction of the absolute value of total suspended particles can be made using composites of positives of MSS bands 5 and 6 which have been precisely made using the step wedge supplied on the imagery. Predictions of the relative value of the extinction coefficient can be made using bands 4 and 5. Thematic charts of total suspended particles (particles per litre) and extinction coefficient provide scientists conducting state and federal water sampling programs in New York Bight with data which improves the performance of these programs.

Yost, E.↗

Materials International Space Station Experiment-6 (MISSE-6) Atomic Oxygen Fluence Monitor Experiment

An atomic oxygen fluence monitor was flown as part of the Materials International Space Station Experiment-6 (MISSE-6). The monitor was designed to measure the accumulation of atomic oxygen fluence with time as it impinged upon the ram surface of the MISSE 6B Passive Experiment Container (PEC). This was an active experiment for which data was to be stored on a battery-powered data logger for post-flight retrieval and analysis. The atomic oxygen fluence measurement was accomplished by allowing atomic oxygen to erode two opposing wedges of pyrolytic graphite that partially covered a photodiode. As the wedges of pyrolytic graphite erode, the area of the photodiode that is illuminated by the Sun increases. The short circuit current, which is proportional to the area of illumination, was to be measured and recorded as a function of time. The short circuit current from a different photodiode, which was oriented in the same direction and had an unobstructed view of the Sun, was also to be recorded as a reference current. The ratio of the two separate recorded currents should bear a linear relationship with the accumulated atomic oxygen fluence and be independent of the intensity of solar illumination. Ground hyperthermal atomic oxygen exposure facilities were used to evaluate the linearity of the ratio of short circuit current to the atomic oxygen fluence. In flight, the current measurement circuitry failed to operate properly, thus the overall atomic oxygen mission fluence could only be estimated based on the physical erosion of the pyrolytic graphite wedges. The atomic oxygen fluence was calculated based on the knowledge of the space atomic oxygen erosion yield of pyrolytic graphite measured from samples on the MISSE 2. The atomic oxygen fluence monitor, the expected result and comparison of mission atomic oxygen fluence based on the erosion of the pyrolytic graphite and Kapton H atomic oxygen fluence witness samples are presented in this paper.

Banks, Bruce A.↗