At least 19 records

Development of a precision, wide-dynamic-range actuator for use in active optical systems

The design, operation, and performance of a wide-dynamic-range optical-quality actuator are discussed. The actuator uses a closed-loop control system to maintain accurate positioning and has an rms noise performance of 20 nm. A unique force offloading mechanism allows the actuator coil to dissipate less than 3 mW under quiescent conditions. The operation of an experimental segmented optical system that uses 18 of the actuators is examined to show how they are integrated into an actual system.

Lorell, K. R.↗

Low Power, Wide Dynamic Range Carbon Nanotube Vacuum Gauges

This slide presentation presents carbon nanotube vacuum pressure sensor gauges that operate at low power and exhibit a wide-dynamic range based on microelectromechanical systems (MEMS) technology. The fabrication facility, and the formation process are shown. Pressure sensitivity was found to increase rapidly as the bias power was increased. In addition, by etching part of the thermal SiO2 beneath the tubes and minimizing heat conduction through the substrate, pressure sensitivity was extended toward lower pressures. Results are compared to a conventional thin film meander resistor, which was fabricated and whose pressure response was also measured for comparative purposes.

JEOL E-beam aligner↗

High Precision Sunphotometer using Wide Dynamic Range (WDR) Camera Tracking

The NASA Ames Sun-photometer-Satellite Group, DOE, PNNL Atmospheric Sciences and Global Change Division, and NASA Goddards AERONET (AErosol RObotic NETwork) team recently collaborated on the development of a new airborne sunphotometry instrument that provides information on gases and aerosols extending far beyond what can be derived from discrete-channel direct-beam measurements, while preserving or enhancing many of the desirable AATS features (e.g., compactness, versatility, automation, reliability). The enhanced instrument combines the sun-tracking ability of the current 14-Channel NASA Ames AATS-14 with the sky-scanning ability of the ground-based AERONET Sunsky photometers, while extending both AATS-14 and AERONET capabilities by providing full spectral information from the UV (350 nm) to the SWIR (1,700 nm). Strengths of this measurement approach include many more wavelengths (isolated from gas absorption features) that may be used to characterize aerosols and detailed (oversampled) measurements of the absorption features of specific gas constituents. The Sky Scanning Sun Tracking Airborne Radiometer (3STAR) replicates the radiometer functionality of the AATS14 instrument but incorporates modern COTS technologies for all instruments subsystems. A 19-channel radiometer bundle design is borrowed from a commercial water column radiance instrument manufactured by Biospherical Instruments of San Diego California (ref, Morrow and Hooker)) and developed using NASA funds under the Small Business Innovative Research (SBIR) program. The 3STAR design also incorporates the latest in robotic motor technology embodied in Rotary actuators from Oriental motor Corp. having better than 15 arc seconds of positioning accuracy. Control system was designed, tested and simulated using a Hybrid-Dynamical modeling methodology. The design also replaces the classic quadrant detector tracking sensor with a wide dynamic range camera that provides a high precision solar position tracking signal as well as an image of the sky in the 45 field of view around the solar axis, which can be of great assistance in flagging data for cloud effects or other factors that might impact data quality.

aerosols↗

Carbon nanotube vacuum gauges with wide-dynamic range and processes thereof

A miniature thermal conductivity gauge employs a carbon single-walled-nanotube. The gauge operates on the principle of thermal exchange between the voltage-biased nanotube and the surrounding gas at low levels of power and low temperatures to measure vacuum across a wide dynamic range. The gauge includes two terminals, a source of constant voltage to the terminals, a single-walled carbon nanotube between the terminals, a calibration of measured conductance of the nanotube to magnitudes of surrounding vacuum and a current meter in electrical communication with the source of constant voltage. Employment of the nanotube for measuring vacuum includes calibrating the electrical conductance of the nanotube to magnitudes of vacuum, exposing the nanotube to a vacuum, applying a constant voltage across the nanotube, measuring the electrical conductance of the nanotube in the vacuum with the constant voltage applied and converting the measured electrical conductance to the corresponding calibrated magnitude of vacuum using the calibration. The nanotube may be suspended to minimize heat dissipation through the substrate, increasing sensitivity at even tower pressures.

Manohara, Harish↗

Logarithmic circuit with wide dynamic range

A circuit deriving an output voltage that is proportional to the logarithm of a dc input voltage susceptible to wide variations in amplitude includes a constant current source which forward biases a diode so that the diode operates in the exponential portion of its voltage versus current characteristic, above its saturation current. The constant current source includes first and second, cascaded feedback, dc operational amplifiers connected in negative feedback circuit. An input terminal of the first amplifier is responsive to the input voltage. A circuit shunting the first amplifier output terminal includes a resistor in series with the diode. The voltage across the resistor is sensed at the input of the second dc operational feedback amplifier. The current flowing through the resistor is proportional to the input voltage over the wide range of variations in amplitude of the input voltage.

Wiley, P. H.↗

Log amplifier instrument measures physiological biopotentials over wide dynamic range

To record biopotentials with extreme dynamic ranges, biopotential inputs are capacitatively coupled to a miniature, low power, solid-state signal conditioner consisting of a two-stage differential preamplifier that has a low noise figure. The ouput of the preamplifier uses diodes to provide an overall gain which is nearly logarithmic.

Kado, R. T.↗

Wide-range dynamic pressure sensor

Transducer measures pressure by sensing the damping of a vibrating diaphragm immersed in the atmosphere to be measured. Improved sensor can be included in rugged, lightweight package for use aboard aircraft, meteorological vehicles, and space probes.

Dimeff, J.↗

Evaluation of some wide dynamic range readout systems for photoelectric integrating spectrometers

Five types of electronic circuits commonly used for readout of currents from photomultiplier tubes were evaluated. This evaluation was conducted to define the experimental limits of achieving the widest possible dynamic range of light detection and concentration measurements in spectrochemical analysis. The circuits evaluated included the photon-counting technique and four dc circuits. These circuits displayed a dynamic range from 3 to about 4.5 decades within a repeatability criterion of 1 percent, or better. The maximum dynamic range allowed by the photomultiplier tube in this application was estimated to be about 6 decades.

Franklin, M. L.↗

Testing the linearity of response of gated photomultipliers in wide dynamic range laser radar systems

Laser radar data acquisition systems have been utilized in conjunction with a light emitting diode to evaluate photomultipliers for laser radar use. Light pulses with an exponential decay rate of approximately one decade per sixty microseconds, as well as other pulse shapes, were used to drive the tubes. Properties studied in the analog mode include nonlinearity at high output currents, transient behavior upon gating, gate holdoff, dynamic range limitations because of light-induced noise, and the effect of dynode gating on tubes without a focus grid. Some of these properties were also studied in the photon counting mode, along with single photoelectron pulse shape and afterpulsing. A brief description of the laser radar technique of atmospheric measurements is included.

Hunt, W. H.↗

Wide-dynamic-range detector

Circuit drives diode detector with amplifier having high and constant output impedance. Basic circuit could be used in high-performance AM radios, tape players, and phonographs.

Matheson, R. J.↗

(abstract) Wide Dynamic Range Porous Plug and Vent Line for SIRTF

The most recent approach to the Space Infrared Telescope Facility (SIRTF) uses a new design concept in which the telescope is launched warm and subsequently cooled to operating temperture on orbit. At launch the cryostat is at 2 K and the telescope is at room temperature. Cooldown of the telescope will be accomplished initially through radiation to space. Final cooldown to the 5.5 K operating temperature is done with helium vapor. Initially the helium flow on orbit will be 10 to 20 times larger than required for steady-state operation. The vent line and the liquid-vapor phase separator (porous plug) therefore must accomodate a large dynamic operational range. For ground testing of IR instruments, the required temperature is 1.5 K. The helium tank temperature for both ground testing and space operations thus needs to be 1.4 K. We will present a discussion of the requirements, a conceptual design, and initial laboratory test results with candidate porous plugs and associated instrumentation. A discussion of possible connections to the design of Gravity Probe-B cryostat will also be presented.

infrared space helium cryostat↗

Wide Dynamic Range Porous Plug for SIRTF

The most recent approach to the Space Infrared Telescope Facility (SIRTF) uses a new design concept in which the telescope is launched warm and subsequently cooled to operating temperature on orbit. At launch, the cryostat is at 2 K and the telescope is at room temperature. Cooldown of the telescope will be accomplished initially through radiation to space. Final cooldown to the 5.5 K operating temperature is done with helium vapor. Initially, the helium flow on orbit will be 20 to 30 times larger than required for steady-state operation. The vent line and the liquid/vapor phase separator (porous plug) therefore must accommodate a large dynamic operational range.For ground testing of IR instruments, the required temperature is 1.5 K. The helium tank temperature for both ground testing and space operations thus needs to be at 1.4 K. We present a discussion of the requirements, a conceptual design, and initial laboratory test results with candidate porous plugs and associated instrumentation. A discussion of possible connections to the design of the Gravity Probe-B cryostat will be presented also.

SIRTF, Liquid/Vapor Phase, Separator, Porous Plug↗

Conductance measurement circuit with wide dynamic range

A conductance measurement circuit to measure conductance of a solution under test with an output voltage proportional to conductance over a 5-decade range, i.e., 0.01 uS to 1000 uS or from 0.1 uS to 10,000 uS. An increase in conductance indicates growth, or multiplication, of the bacteria in the test solution. Two circuits are used each for an alternate half-cycle time periods of an alternate squarewave in order to cause alternate and opposite currents to be applied to the test solution. The output of one of the two circuits may be scaled for a different range optimum switching frequency dependent upon the solution conductance and to enable uninterrupted measurement over the complete 5-decade range. This circuitry provides two overlapping ranges of conductance which can be read simultaneously without discontinuity thereby eliminating range switching within the basic circuitry. A VCO is used to automatically change the operating frequency according to the particular value of the conductance being measured, and comparators indicate which range is valid and also facilitate computer-controlled data acquisition. A multiplexer may be used to monitor any number of solutions under test continuously.

Mount, Bruce E.↗

A 100,000 pulse height analyzer for use in High Energy Cosmic Ray Experiments (HECRE) on high altitude balloon flights

A description is given of a wide dynamic range pulse height analyzer system developed for use on High Energy Cosmic Ray Experiment (HECRE) Balloon Flights. A wide dynamic range of 100,000 is obtained by extending the range of a basic 1024 channel analyzer through the use of multiple ranges and range selection. The system described here contains four 100,000 pulse height analyzers. Each 100,000 pulse height analyzer consists of a group of cordwood welded modules mounted and interconnected on a printed circuit card. Four of these card assemblies, the required clock drive circuitry (discrete components mounted and interconnected on a separate card) and three input-output connectors are interconnected and mounted on the system board.

Cancro, C. A.↗

Fiber-Optic/Photoelastic Flow Sensors

Simple, rugged, lightweight transducers detect periodic vortices. Fiber-optic-coupled transducers developed to measure flows over wide dynamic ranges and over wide temperature ranges in severe environments. Used to measure flows of fuel in advanced aircraft engines. Feasibility of sensors demonstrated in tests of prototype sensor in water flowing at various temperatures and speeds. Particularly attractive for aircraft applications because optical fibers compact and make possible transmission of sensor signals at high rates with immunity from electromagnetic interference at suboptical frequencies. Sensors utilize optical-to-optical conversion via photoelastic effect.