Search NASA⌕ Search

SEARCH · Search NASA

Results for “wide dynamic range camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Characterization of a Fast-Framing X-Ray Camera With Wide Dynamic Range for High-Energy Imaging

We present first characterization results, with a focus on high-flux measurements, of a fast-framing, wide-dynamic-range x-ray camera intended for high-energy imaging. The MM-PAD-2.1 uses an integrating pixel front-end with a charge removal architecture and in-pixel counter to extend the pixel well depth while maintaining low read noise across the full dynamic range. The charge-removal mechanism is dead-time-less (i.e., incoming signal continues to be integrated by the front-end while charge removal is taking place). The purpose of the highflux characterization was to determine the maximum sustained incident flux that could be measured while still exhibiting linear behavior. To this end, a 16 x 16 pixel prototype was tested at the Advanced Photon Source at Argonne National Laboratory using 10 keV photons generated by an undulator source. The intensity of the incident beam was varied over 3 orders of magnitude using a series of attenuators, and the signal integrated by the MM-PAD-2.1 prototype was compared to that measured by a He-filled ion chamber directly upstream. Initial results indicate linear performance up to ca. 10(10) ph/s in a spot spanning approximately 2 x 1.5 pixels (FWHM). The onset of transient radiation damage was observed during these measurements, characterized primarily by failure of digital readout from the detector ASIC. These effects were observed to reverse after annealing at 30 degrees C for several hours, with full recovery of the detector readout.

Shanks, Katherine S.↗

Picosecond X-ray streak camera dynamic range measurement

Streak cameras are widely used to record the spatio-temporal evolution of laser-induced plasma. A prototype of picosecond X-ray streak camera has been developed and tested by Commissariat à l’Énergie Atomique et aux Énergies Alternatives to answer the Laser MegaJoule specific needs. The dynamic range of this instrument is measured with picosecond X-ray pulses generated by the interaction of a laser beam and a copper target. The required value of 100 is reached only in the configurations combining the slowest sweeping speed and optimization of the streak tube electron throughput by an appropriate choice of high voltages applied to its electrodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic granularity of imaging systems

Imaging systems that include a specific source, imaging concept, geometry, and detector have unique properties such as signal-to-noise ratio, dynamic range, spatial resolution, distortions, and contrast. Some of these properties are inherently connected, particularly dynamic range and spatial resolution. It must be emphasized that spatial resolution is not a single number but must be seen in the context of dynamic range and consequently is better described by a function or distribution. We introduce the “dynamic granularity” G dyn as a standardized, objective relation between a detector’s spatial resolution (granularity) and dynamic range for complex imaging systems in a given environment rather than the widely found characterization of detectors such as cameras or films by themselves. We found that this relation can partly be explained through consideration of the signal’s photon statistics, background noise, and detector sensitivity, but a comprehensive description including some unpredictable data such as dust, damages, or an unknown spectral distribution will ultimately have to be based on measurements. Measured dynamic granularities can be objectively used to assess the limits of an imaging system’s performance including all contributing noise sources and to qualify the influence of alternative components within an imaging system. Our article explains the construction criteria to formulate a dynamic granularity and compares measured dynamic granularities for different detectors used in the X-ray backlighting scheme employed at Sandia’s Z-Backlighter facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved site-selective imaging of predissociation and charge transfer dynamics: the CH 3 I B-band

The predissociation dynamics of the 6s (B 2 E) Rydberg state of gas-phase CH 3 I were investigated by time-resolved Coulomb-explosion imaging using extreme ultraviolet (XUV) free-electron laser pulses. Inner-shell ionization at the iodine 4d edge was utilized to provide a site-specific probe of the ensuing dynamics. The combination of a velocity-map imaging (VMI) spectrometer coupled with the pixel imaging mass spectrometry (PImMS) camera permitted three-dimensional ionic fragment momenta to be recorded simultaneously for a wide range of iodine charge states. In accord with previous studies, initial excitation at 201.2 nm results in internal conversion and subsequent dissociation on the lower-lying A-state surface on a picosecond time scale. Examination of the time-dependent yield of low kinetic energy iodine fragments yields mechanistic insights into the predissociation and subsequent charge transfer following multiple ionization of the iodine products. The effect of charge transfer was observed through differing delay-dependencies of the various iodine charge states, from which critical internuclear distances for charge transfer could be inferred and compared to a classical over-the-barrier model. Time-dependent photofragment angular anisotropy parameters were extracted from the central slice of the Newton sphere, without Abel inversion, and highlight the effect of rotation of the parent molecule before dissociation, as observed in previous works. Our results demonstrate the ability to perform three-dimensional ion imaging at high event rates and showcase the potential benefits of this approach, particularly in relation to further time-resolved studies at free-electron laser facilities.

74 ATOMIC AND MOLECULAR PHYSICS↗

Dictionary Learning with Accumulator Neurons

The Locally Competitive Algorithm (LCA) uses local competition between non-spiking leaky integrator neurons to infer sparse representations, allowing for potentially real-time execution on massively parallel neuromorphic architectures such as Intel's Loihi processor. Here, we focus on the problem of inferring sparse representations from streaming video using dictionaries of spatiotemporal features optimized in an unsupervised manner for sparse reconstruction. Non-spiking LCA has previously been used to achieve unsupervised learning of spatiotemporal dictionaries composed of convolutional kernels from raw, unlabeled video. We demonstrate how unsupervised dictionary learning with spiking LCA (\hbox{S-LCA}) can be efficiently implemented using accumulator neurons, which combine a conventional leaky-integrate-and-fire (\hbox{LIF}) spike generator with an additional state variable that is used to minimize the difference between the integrated input and the spiking output. We demonstrate dictionary learning across a wide range of dynamical regimes, from graded to intermittent spiking, for inferring sparse representations of both static images drawn from the CIFAR database as well as video frames captured from a DVS camera. On a classification task that requires identification of the suite from a deck of cards being rapidly flipped through as viewed by a DVS camera, we find essentially no degradation in performance as the LCA model used to infer sparse spatiotemporal representations migrates from graded to spiking. We conclude that accumulator neurons are likely to provide a powerful enabling component of future neuromorphic hardware for implementing online unsupervised learning of spatiotemporal dictionaries optimized for sparse reconstruction of streaming video from event based DVS cameras.

artificial intelligence↗

Instrumental Response Model and Detrending for the Dark Energy Camera

We describe the model for mapping from sky brightness to the digital output of the Dark Energy Camera (DECam) and the algorithms adopted by the Dark Energy Survey (DES) for inverting this model to obtain photometric measures of celestial objects from the raw camera output. This calibration aims for fluxes that are uniform across the camera field of view and across the full angular and temporal span of the DES observations, approaching the accuracy limits set by shot noise for the full dynamic range of DES observations. The DES pipeline incorporates several substantive advances over standard detrending techniques, including principal-components-based sky and fringe subtraction; correction of the "brighter-fatter" nonlinearity; use of internal consistency in on-sky observations to disentangle the influences of quantum efficiency, pixel-size variations, and scattered light in the dome flats; and pixel-by-pixel characterization of instrument spectral response, through combination of internal-consistency constraints with auxiliary calibration data. This article provides conceptual derivations of the detrending/calibration steps, and the procedures for obtaining the necessary calibration data. Other publications will describe the implementation of these concepts for the DES operational pipeline, the detailed methods, and the validation that the techniques can bring DECam photometry and astrometry within $\approx 2$ mmag and $\approx 3$ mas, respectively, of fundamental atmospheric and statistical limits. In conclusion, the DES techniques should be broadly applicable to wide-field imagers.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of Low-cost, Full HD, CMOS Cameras for Use in the Calcine Retrieval Project - 19530

This paper describes results from radiation testing conducted on low-cost, commercial off-the-shelf, full high-definition (HD) resolution (1920 x 1080 p), complementary metal-oxide-semiconductor (CMOS) camera sensors. The purpose of the testing was to evaluate the sensors' suitability for use in the Calcine Retrieval Project by determining their image quality and life expectancy while operating in an ionizing radiation field of 20.0 Gy/h. The two camera sensors tested were the Axis FA1105 and Axis FA1125. These commercial camera sensors were designed for retail security surveillance and have no radiation-hardened (rad-hard) components. In addition to radiation testing, the sensors' field-of-view, resolution, and low-light image quality were tested at several target distances to ensure they meet project requirements. Testing was divided into two phases. During Phase 1, four FA1105 sensors and four FA1125 sensors were tested simultaneously without any shielding in radiation fields of 25.5 Gy/h and 49.3 Gy/h. In Phase 2, three FA1105 and five FA1125 sensors were shielded by 22.2 mm of lead and tested simultaneously in radiation fields of 26.8 Gy/h, 52.3 Gy/h, 143.0 Gy/h, 200.7 Gy/h, 404.6 Gy/h, and 2,317.5 Gy/h. Dose rate values were established using film dosimetry readings. Apertures in the shielding allowed for a 40-degree field of view while shielding all parts of the sensor except for directly in front of the CMOS sensor array. All testing was conducted at the Idaho Accelerator Center in Pocatello, Idaho, using a 450 keV X-ray generator. Sensor images were automatically captured at regular intervals throughout the testing for qualitative evaluation by the test team. Film dosimetry was placed near the sensors to record actual dose totals. The 450 keV setting generates X-ray radiation with an energy level close to the primary gamma energy level produced by the Cesium-137 isotope in the calcine, which is 662 keV. Results from Phase 1 indicate the sensors failed at an average cumulative dose of 226.3 Gy. For a given 20.0 Gy/h field this results in a mean time to failure (MTTF) of 11.3 hours. Recorded images from all sensors showed minimal image degradation due to radiation-induced noise. When the sensors finally failed, the failure mode was an abrupt loss of video. The image went black suggesting some other component in the sensor head besides the CMOS sensor array was responsible for the failure. During a portion of Phase 1 testing, a commercial, rad-hard camera was irradiated in the 25.5 Gy/h field along with the eight Axis FA series sensors. Image quality from the FA series sensors significantly outperformed the image quality of the rad-hard camera in radiation-induced noise tolerance, image resolution, and dynamic range. During Phase 2 testing, all sensors produced excellent images in radiation fields as high as 404.6 Gy/h. One FA1125 sensor was tested at the highest dose rate of 2,317.5 Gy/h. At this dose rate, the image was color shifted towards red and contained a significant amount radiation-induced noise. The sensor did not fail and was producing usable imagery after one hour, at which time the test was ended due to allotted beam-time at the test facility. Eighteen hours after X-rays were shut off, the sensor image returned to normal color and all eight sensors continued to operate without any visible, permanent image degradation. For Phase 2 testing, it was not possible to establish a MTTF since none of the shielded sensors failed during the allotted test time. However, given the highest cumulative dose of 4,142.1 Gy received by a shielded FA1125 sensor, a minimum life expectancy of 207 hours (8.6 days) is predicted while operating in a 20.0 Gy/h field. Test results indicate the radiation tolerance of the FA series sensor's CMOS array, along with the small form factor, full HD image quality, wide dynamic range, and Ethernet standard makes it suitable for short-term use in monitoring and visually documenting waste remediation efforts for the Calcine Retrieval Project at the INL. The sensor's low-cost of about $140 US, compared to commercial rad-hard cameras costing between $5,000 and $7,000 US each, allow them to be used as an affordable, disposable resource for many short-duration, radioactive waste remediation efforts where decontamination of an expensive, commercial rad-hard camera is undesirable or not possible. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reliable and Repeatable Characterization of Optical Streak Cameras

Optical streak cameras are used as primary diagnostics for a wide range of physics and laser experiments at facilities such as the National Ignition Facility (NIF). To meet the strict accuracy requirements needed for these experiments, the systematic nonlinearities of the streak cameras (attributed to nonlinearities in the optical and electrical components that make up the streak camera system) must be characterized. In some cases the characterization information is used as a guide to help determine how experiment data should be taken. In other cases, the characterization data are applied to the raw data images to correct for the nonlinearities. In order to characterize an optical streak camera, a specific set of data is collected, where the response to defined inputs are recorded. A set of analysis software routines has been developed to extract information such as spatial resolution, dynamic range, and temporal resolution from this data set. The routines are highly automated, requiring very little user input and thus provide very reliable and repeatable results that are not subject to interpretation. An emphasis on quality control has been placed on these routines due to the high importance of the camera characterization information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Strain Rate Mechanical Characterization of Carbon Fiber Reinforced Polymer Composites Using Digital Image Correlations

We present that the introduction of carbon fiber reinforced polymer (CFRP) composites to structural components in lightweight automotive structures necessitates an assessment to evaluate that their crashworthiness dynamic response provides similar or higher levels of safety compared to conventional metallic structures. In order to develop, integrate and implement predictive computational models for CFRP composites that link the materials design, molding process and final performance requirements to enable optimal design and manufacturing vehicle systems for this study, the dynamic mechanical response of unidirectional (UD) and 2x2 twill weave CRFP composites was characterized at deformation rates applicable to crashworthiness performance. Non-standardized specimen geometries were tested on a standard uniaxial frame and an intermediate-to-high speed dynamic testing frame, equipped with high speed cameras for 3D digital image correlation (DIC). Specimen cross-sections, according to each fiber orientation tested, were consistent across strain rates to ensure results were comparable. Tensile strength and modulus were experimentally investigated over a wide range of strain rates (0.0001 to 200 s -1 ). DIC was used to estimate strain profiles on composites surfaces, and the modulus was calculated from those strain measurements. Experimental results demonstrated an increase in the tensile strength of UD CFRP composites in the longitudinal (0°) and transverse (90°) direction with increasing strain rates. In contrast, the tensile strength of 2x2 woven composites and the tensile modulus of the UD material were insensitive to increasing strain rates. Finally, comparison of failure modes provided insights on how loading rates influenced failure mechanisms.

36 MATERIALS SCIENCE↗

STELLAR KINEMATICS OF z {approx} 2 GALAXIES AND THE INSIDE-OUT GROWTH OF QUIESCENT GALAXIES {sup ,}

Using stellar kinematics measurements, we investigate the growth of massive, quiescent galaxies from z {approx} 2 to today. We present X-Shooter spectra from the UV to NIR and dynamical mass measurements of five quiescent massive (>10{sup 11} M{sub Sun }) galaxies at z {approx} 2. This triples the sample of z > 1.5 galaxies with well-constrained ({delta}{sigma} < 100 km s{sup -1}) velocity dispersion measurements. From spectral population synthesis modeling we find that these galaxies have stellar ages that range from 0.5 to 2 Gyr, with no signs of ongoing star formation. We measure velocity dispersions (290-450 km s{sup -1}) from stellar absorption lines and find that they are 1.6-2.1 times higher than those of galaxies in the Sloan Digital Sky Survey at the same mass. Sizes are measured using GALFIT from Hubble Space Telescope Wide Field Camera 3 H{sub 160} and UDS K-band images. The dynamical masses correspond well to the spectral energy distribution based stellar masses, with dynamical masses that are {approx}15% higher. We find that M{sub *}/M{sub dyn} may decrease slightly with time, which could reflect the increase of the dark matter fraction within an increasing effective radius. We combine different stellar kinematic studies from the literature and examine the structural evolution from z {approx} 2 to z {approx} 0: we confirm that at fixed dynamical mass, the effective radius increases by a factor of {approx}2.8, and the velocity dispersion decreases by a factor of {approx}1.7. The mass density within one effective radius decreases by a factor of {approx}20, while within a fixed physical radius (1 kpc) it decreases only mildly (factor of {approx}2). When we allow for an evolving mass limit by selecting a population of galaxies at fixed number density, a stronger size growth with time is found (factor of {approx}4), velocity dispersion decreases by a factor of {approx}1.4, and interestingly, the mass density within 1 kpc is consistent with no evolution. This finding suggests that massive quiescent galaxies at z {approx} 2 grow inside out, consistent with the expectations from minor mergers.

79 ASTRONOMY AND ASTROPHYSICS↗

Longitudinal bunch shaping of picosecond high-charge MeV electron beams

With ever increasing demands for intensities in modern accelerators, the understanding of space-charge effects becomes crucial. Herein are presented measurements of optically shaped picosecond-long electron beams in a superconducting L-band linac over a wide range of charges, from 0.2 nC to 3.4 nC. At low charges, the shape of the electron beam is preserved, while at higher charge densities, modulations on the beam convert to energy modulations. Here, energy profile measurements using a spectrometer and time profile measurements using a streak camera reveal the dynamics of longitudinal space-charge on MeV-scale electron beams.

43 PARTICLE ACCELERATORS↗

Multimodal sensor fusion for real-time standoff estimation in directed energy deposition

In Laser Powder-based Direct Energy Deposition (LP-DED) systems, achieving consistency, precision and quality of produced parts requires tight control over printing parameters. One of the critical parameters is the standoff distance. Maintaining an optimal standoff height is crucial for achieving correct laser power density and powder catchment efficiency, as both laser and powder streams are focused at this distance. Here, this study introduces a novel approach using multimodal sensor fusion to predict standoff height in real-time. The proposed system integrates two low-profile, cost-effective sensors: an RGB coaxial camera and a high frequency and high dynamic range microphone. By utilizing a simple fully connected neural network, trained on a limited dataset, data fusion of these sensors allowed for the real-time prediction of the standoff height. The results demonstrate high resolution and accuracy of the predictions across multiple geometries and a wide range of standoff heights. This approach offers a simple, and cost-effective solution for real-time standoff height monitoring and lays the groundwork for future integration into commercial LP-DED systems.

42 ENGINEERING↗

Coulomb explosion imaging of CH 3 I and CH 2 ClI photodissociation dynamics

The photodissociation dynamics of CH 3 I and CH 2 ClI at 272 nm were investigated by time-resolved Coulomb explosion imaging, with an intense non-resonant 815 nm probe pulse. Fragment ion momenta over a wide m/z range were recorded simultaneously by coupling a velocity map imaging spectrometer with a pixel imaging mass spectrometry camera. For both molecules, delay-dependent pump-probe features were assigned to ultraviolet-induced carbon-iodine bond cleavage followed by Coulomb explosion. Multi-mass imaging also allowed the sequential cleavage of both carbon-halogen bonds in CH 2 ClI to be investigated. Furthermore, delay-dependent relative fragment momenta of a pair of ions were directly determined using recoil-frame covariance analysis. These results are complementary to conventional velocity map imaging experiments and demonstrate the application of time-resolved Coulomb explosion imaging to photoinduced real-time molecular motion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative high dynamic range beam profiling for fluorescence microscopy

Modern developmental biology relies on optically sectioning fluorescence microscope techniques to produce non-destructive in vivo images of developing specimens at high resolution in three dimensions. As optimal performance of these techniques is reliant on the three-dimensional (3D) intensity profile of the illumination employed, the ability to directly record and analyze these profiles is of great use to the fluorescence microscopist or instrument builder. Though excitation beam profiles can be measured indirectly using a sample of fluorescent beads and recording the emission along the microscope detection path, we demonstrate an alternative approach where a miniature camera sensor is used directly within the illumination beam. Measurements taken using our approach are solely concerned with the illumination optics as the detection optics are not involved. We present a miniature beam profiling device and high dynamic range flux reconstruction algorithm that together are capable of accurately reproducing quantitative 3D flux maps over a large focal volume. Performance of this beam profiling system is verified within an optical test bench and demonstrated for fluorescence microscopy by profiling the low NA illumination beam of a single plane illumination microscope. The generality and success of this approach showcases a widely flexible beam amplitude diagnostic tool for use within the life sciences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-high speed burst-mode imager for multi-frame radiography

A 720 x 720 pixel hybrid-CMOS imager was fabricated by Rockwell Scientific (now Teledyne Imaging Sensors). Several cameras have been in operation for 5 years, in a variety of static and dynamic experiments, at the 800MeV proton radiography (pRAD) facility at the LANSCE accelerator. The cameras can operate with a per-pulse adjustable inter-frame time of 250ns to 2s, and with an exposure/integration-time as short as 150 ns. Given the 800 ms total readout time, the imager can be externally synchronized to 0.1-to-5Hz, 50-ns wide proton beam pulses, and record 1000-frame radiographic movies of 5-to-30 minute duration. The effectiveness and dependence of the global electronic shutter on the pixelated Si photo-sensor bias voltage is discussed. The spatial resolution dependence of the full imaging system on various monolithic and structured scintillators is presented. We also present features of a new-generation 10-frame, 1024 x 1024 pixel, 50-ns exposure, 12-bit dynamic range imager, which is now in the design phase.

47 OTHER INSTRUMENTATION↗

High Performances and Low Cost Front-End Electronics for the Cherenkov Telescope Array

The current Imaging Arrays of Cherenkov Telescopes (IACT) show that this technique is mature. Front-end electronics based on analogue pipelines become a popular readout solution. Slow noise and low power consumption ASICs were developed with improved dynamical range and linearity. A large bandwidth preserves the characteristics of the signal and fast readout reduces dead time. Next generation of IACT should reach an order of magnitude in sensitivity in a wide energy band, ranging from 10 GeV to more than 100 TeV. This goal can be reached with an array of 50-100 telescopes of various sizes at various spacings. With about 2 000 channels per camera a significant effort must be done to lower the overall cost and improve the performances of the electronics. Mass production will be determinant for lowering the overall cost. A gain in cost and performances can be obtained by maximising the integration of the front-end electronics in an ASIC. The amplifiers, analogue memories, digitization and first level buffering can be embedded in the same component. The first stage of the first level trigger should be also considered in this integration. Integrated electronics leads to a more compact camera and an easier maintenance on site.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a Microchannel Plate-Based Gated X-ray Imager for Imaging and Spectroscopy Experiments on Z

This poster describes a microchannelplate (MCP)–based, gated x-ray imager developed by National Security Technologies, LLC (NSTec), and Sandia National Laboratories(SNL) over the past several years. The camera consists of a 40 mm × 40 mm MCP, coated with eight 4 mm wide microstrips. The camera is gated by sending subnanosecond high-voltage pulses across the striplines. We have performed an extensive characterization of the camera, the results of which we present here. The camera has an optical gate profile width (time resolution) as narrow as 150 ps and detector uniformity of better than 30% along the length of a strip, far superior than what was achieved in previous designs. The spatial resolution is on the order of 40 microns for imaging applications and a dynamic range of between ~100 and ~1000. We also present results from a Monte Carlo simulation code developed by NSTec over the last several years. Agreement between the simulation results and the experimental measurements is very good.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a CMOS camera based film digitization platform for gated x-ray imaging diagnostics at the National Ignition Facility

Hardened gated x-ray detectors use photographic film as the data recording medium due to its low sensitivity to the high-yield neutron environments at the National Ignition Facility (NIF). The photographic film is digitized with a Photometric Data Systems (PDS) microdensitometer, which measures the film’s optical density. The PDS scanner is able to measure a dynamic range of 0–5 OD; however, raster scanning the film is time consuming and maintenance of the instrument is challenging due to legacy technology. Since film usage at NIF is expected to continue in the foreseeable future, a digitization platform that is faster and more maintainable would benefit the NIF’s current and future operations. Here, this work presents the characterization of the digital transitions (DT) atom, a CMOS camera-based digitization platform that records film data in a single image capture very quickly and has widely available user support. The preliminary results suggest that the DT atom is able to reconstruct exposures accurately enough to be a competitive alternative to the PDS Scanner.

47 OTHER INSTRUMENTATION↗